Motor Drain PumpFrom: Ulf Lindmark ES-STO [ulf.lindmark@intertek.

com] Sent: Friday, November 12, 2004 11:07 PM To: Loh Siak Chun (OYLR&D) Cc: Chun Siew Siew (OYLR&D) Subject: SV: Motor Drain Pump Dear All,

The drain pump used in your unit need not to be certified (for IEC) The drain pump is tested as a part of the appliance

You do heating test and measure the winding temperature during normal operation. This is usually continuously pumping of water. Then you do the locked rotor test and measure the winding temperature.

The rest will be checking of clearance and creepage distances etc.

Best regards

Ulf Lindmark

-------------------------------------------------------------------------------Fr n: Loh Siak Chun (OYLR&D) [mailto:lohsc@oyl.com.my] Skickat: den 8 november 2004 02:27 Till: Ulf Lindmark ES-STO Kopia: Chun Siew Siew (OYLR&D) mne: Motor Drain Pump Prioritet: H g

Dear Ulf, Do we need to get our motor drain pump tested & certified? If yes, kindly porpsoe what kind of test to be conducted. Thank you For your information, the drain pump is used in our CK units

Best Regards, Loh Siak Chun

R&D Engineer OYL Research & Development Centre Tel: 603-61570846 / 61570920 Fax: 603-61570869