UpSwitch FACH 2 DCH

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Channel Switching Evaluation decides common->dedicated channel switch needed UL Upswitch Trigged by?

DL Upswitch

Decision to switch if DL or UL buffer load above a threshold

If targetUlRate <= 64 pmUlUpswitchAttemptLow + If targetUlRate = Eul pmUlUpswitchAttemptEul +

If targetDlRate <= 64 pmDlUpswitchAttemptLow + If targetDlRate = HS pmDlUpswitchAttemptHs + pmUpswitchFachHsAttempt +

Check MP Load Control Load ok? YES Admission Control NO End NO

NBAP/RNSAP: Radio Link Setup Request NBAP/RNSAP: Radio Link Setup Response RRC: Radio Bearer Reconfiguration RRC: Radio Bearer Reconfiguration Complete

Admission granted? YES Messages Received/Sent

FACH to DCH switch successful? YES

NO

pmLevelPsInteractive + pmLevelUesWith1Rls1RlInActSet + pmNoOfRlForNonDriftingUes + If targetUlRate <= 64 pmUlUpswitchSuccessLow + If targetUlRate = Eul pmUlUpswitchSuccessEul + If targetDlRate <= 64 pmDlUpswitchSuccessLow + If targetDlRate = HS pmDlUpswitchSuccessHs + pmUpswitchFachHsSuccess + End

Possible to revert to FACH? YES Release new resources Stay on common channel Send message End RRC Connection Release End NO RANAP: IuRelease Request

C 00 01128J