air required inside the furnace. Given: Weight of combustion air Temperature of air Density of air at 86F 92,721 cu.ft/min 86F 0.0727 lb/cu.ft
= =
c.2) Required draft, Ps i) Furnace + (400 mm) + (30 mm) + (30 mm) + (460 mm) + (575 mm)
Vf x Ps / 102 (0.85)
where: Vf = 7.88 cu.m/sec Ps = required draft, 723 mm = 0.85 ( drive eff.) kWsf = 10.83 x 575 / 102 (0.85)
52.3 kW or 75 hp