Upon completion of this course, you will be able to: Understand MSOFTX3000 system structure Master MSOFTX3000 board function Understand concatenation and cables.
Page 2
References
MSOFTX3000 Hardware Description Manual MSOFTX3000 Hardware Installation Manual MSOFTX3000 Technical Manual System Description
Page 3
Chapter 1 MSOFTX3000 Outline Chapter 2 Board Function Chapter 3 Concatenation and Cables
Page 4
Page 5
RANAP
Mc
Mc
BSSAP
Page 6
MSOFTX3000 Cabinet
MSOFTX3000 adopts N68-22 cabinet It includes integrated configuration and Expansion configuration cabinet 600 mm (width)* 800 mm (depth)* 2200 mm (height) Four frames per cabinet
Page 7
MSOFTX3000 Cabinet
Integrated Configuration Cabinet
Power distribution frame (2U)
Air deflector (2U) Blank panel (2U) Blank panel (2U) KVMS(1U) LANSwitch(1U) Cable through (1U) LANSwitch(1U) Cable through (1U) Hard disk array (3U) BAM (2U) IGWB(2U) IGWB(2U) Blank panel (2U)
Page 8
MSOFTX3000 Frame
The MSC SERVER UNIT frame is designed in conformity with the IEC297 standard and has the following features.
The frame is 19 inches wide and 8U high. The front boards and back boards are plugged into the backplane of the frame. All cables are led out of the frame from the back. The frame accommodates 21 slots. The power boards (UPWR) occupy four slots. The frame enables temperature detection and fan speed adjustment functions.
Page 9
MSOFTX3000 Frame
Classification
Basic frame
The basic frame is configured in the fixed position in the integrated configuration cabinet, providing clock interface, IP interface and E1 interface and implementing service processing.
0 Back boards 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
W B F I W C D B
1
W B F I W I F M
3
W B A I W A F M
4
W B A I W A F M
5
W S I U W S M U
6
W H S C
W S I U W S M U
M H S C
W B F I W I F M
W B F I W I F M W M G C
W C K I W M G C W C D B
W C K I W C D B W A L U
U P W R U P W R
U P W R U P W R
Backplane
W C Front D boards B
0
W I F M
2
9 10 11 12 13 14 15 16 17 18 19 20
Page 10
MSOFTX3000 Frame
Expansion frame The expansion frame is the service processing frame customized according to the subscriber capacity, and it coordinates with the basic frame to implement service processing.
0 Back E boards 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
W W E P P I I W C S U
1
W E P I W C S U
2
W E P I W C S U
3
W E P I W C S U
4
W E P I W C S U
5
W S I U W S M U
6
W H S C
W S I U W S M U
W H S C W C C U W C C U W V D B W V D B W B S G W B S G W A L U
U P W R U P W R
U P W R U P W R
Backplane
W C Front S boards U
0
9 10 11 12 13 14 15 16 17 18 19 20
Page 11
FE Standby iGWB
Frame 1#
GE
Active iGWB
BAM
Emergency WS
Hub
Page 12
Page 13
SLLPM
SPM
WCDB WVDB
OMM
ATM
WMGC WMGC
iGWB iGWB
BC
BITS
BAM
WHSC
NMS
WCCU WCCU
LANSwitch
WS WS
E1
WSIU/WSMU WSIU/WSMU
BUS SSM
Page 14
Chapter 1 MSOFTX3000 Outline Chapter 2 Board Function Chapter 3 Concatenation and Cables
Page 15
Page 16
SLLPM
SPM
WCDB WVDB
OMM
ATM
WMGC WMGC
iGWB iGWB
BC
BITS
BAM
WHSC
NMS
WCCU WCCU
LANSwitch
WS WS
E1
WSIU/WSMU WSIU/WSMU
BUS SSM
Page 17
WSMU
The System Management Unit (WSMU) is the main control board of the MSC SERVER UNIT
LINK ACT
WSMU
Managing all boards in the frame and get boards work status and report to the BAM.
RST
Controlling the indicators on the front panel of the WALU. Loading and managing system programs and data.
ALM RUN DOMA DOMB
Page 18
COM
HUAWEI
WSMU will manage all boards in same frame and help boards
(WIFM/WAFM/WBSG/WSGU/WCCU/WCSU/WCDB/WVDB to load relative data and application through Share resource BUS.
W S I U W H S C W S I U W H S C Share resource BUS
F R O N T SLOT NUMBER 0
F R O N T 1
F R O N T 2
F R O N T 3
F R O N T 4
F R O N T 5
W S M U 6 7
W S M U 8 9
F R O N T 10
F R O N T 11
F R O N T 12
F R O N T 13
F R O N T 14
F R O N T 15
Page 19
WSMUEthernet BUS
Signaling process unit and service process unit WCDB,WVDB,WCCU,WCSU,WIFM,WBSGwill use Ethernet BUS to transmit signaling and service information.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20
W S M U
W S M U
W A L U
The Serial port BUS controls those boards in the frame that are controlled by CPU but not connected to the shared resource bus, such as WCKI, WEPI and WALU.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21
WSIU
W S IU
HD
Providing Ethernet interface to the WSMU. It is configured correspondingly to the WSMU one by one. providing physical interfaces to two asynchronous serial ports. Implementing frame number identification through setting DIP switch.
10/100BT1
H UA W E I
Page 22
10/100BT2
COM3+
COM3
Page 23
WHSC
The Hot-Swap and Control unit (WHSC) is a back board in the MSC SERVER UNIT frame
WHSC
Bridging left and right shared resource buses, for the purpose of assuring that the WSMUs in slots 6 and 8 can respectively manage the front boards Controlling hot-swap of boards, Providing two pairs of heartbeat detection interfaces for the WSMU/WHSC Providing a 10M/100M compatible Ethernet connection between the active WSMU and the standby one Providing six FE ports externally.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24
HUAWEI
10/100BT1 10/100BT2
10/100BT3
10/100BT4
10/100BT5
intra cable
intra cable
WHSC 0
WHSC 1
LANSwitch 0
LANSwitch 1
WHSC 0 External cable External cable External cable WSIU 0 intra cable
W S M U 0
intra cable
intra cable
W S M U 1
intra cable
Page 25
Page 26
Interface Module
9# 0# IM
IP
SLLPM
SPM
WCDB WVDB
OMM
ATM
WMGC WMGC
iGWB iGWB
BC
BITS
BAM
WHSC
NMS
WCCU WCCU
LANSwitch
WS WS
E1
WSIU/WSMU WSIU/WSMU
BUS SSM
Page 27
WIFM/WBFI WIFM
The IP Forward Module (WIFM) is used to receive and transmit IP packets, process Media Access Control (MAC) layer messages and distribute IP messages.
WBFI
WIFM
WBFI
LINK ACT
10/100BT
The Back Insert FE Interface Unit (WBFI) is the back interface board of the WIFM. It is used to perform FE driving, and provide external physical interfaces for the WIFM. It is configured correspondingly to the WIFM one by one.
HUAWEI TECHNOLOGIES CO., LTD. The WBFI works in All rights reserved 1+1 backup mode. Page 28
HUAWEI ALM RUN RST
COM
HUAWEI
WAFM/WBAI
WAFM
WBAI
WAFM
TX
Along with the WBAI, provides ATM interface to perform ATM Adaptation Layer 5 (ATM AAL5) Segmentation And Reassembly (SAR) processing Distribute the packets to the proper WBSG according to the Permanent Virtual Connection (PVC) configurations. WBAI It is used to perform ATM driving and provide ATM STM-1 physical interfaces. The WBAI works in 1+1 backup mode.
LINK ACT
RX MM
HUAWEI
HUAWEI
Page 29
BITS
BITS
W C K I (M)
W C K I (S)
W W E E P P I I (M) (S)
Basic subrack
8k clock cable
8k clock cable
W W E E P P I I (M) (S)
W W E E P P I I (M) (S)
Expansion subrack
Page 30
WEPI
WEPI Providing narrowband signaling physical interfaces for the WCSU. It is configured correspondingly to the WCSU one by one. Processing MTP1 physical layer messages. Transferring system clock signals and providing clock synchronization in the frame. Working with the WCSU to implement active/standby switchover through H.110 bus.
Page 31
WEPIH.110 Bus
BB: Back board
B B B B B B B B B B B B W S I U W H S C W S I U W H S C B B B B B B B B B B B B
8E1
WEPI 0
H.110 bus
WEPI1
H.110 bus
WCSU0
WCSU1
Realize WCSU active/standby switchover Transferring system clock signals for other boards in the same frame
Page 32
Page 33
9# 0# IM
IP
SLLPM
SPM
WCDB WVDB
OMM
ATM
WMGC WMGC
iGWB iGWB
BC
BITS
BAM
WHSC
NMS
WCCU WCCU
LANSwitch
WS WS
E1
WSIU/WSMU WSIU/WSMU
BUS SSM
Page 34
WBSG Mainly used to process IP packets after the WIFM level 1 distribution
Implement coding/decoding for lower layer signaling transmission protocols (UDP, TCP, SIGTRAN, MTP3 and MTP3b) and H.248 bearer control protocol Perform level 2 message distribution to corresponding service processing units for transaction layer/service layer processing.
ATM Driver
WBAI
WAFM
WBSG
AAL5 SAR
SAAL
MTP3b MTP3
H.248
IP Driver
MAC /IP
M3UA
WBFI
WIFM
Page 35
Page 36
SLLPM
SPM
WCDB WVDB
OMM
ATM
WMGC WMGC
iGWB iGWB
BC
BITS
BAM
WHSC
NMS
WCCU WCCU
LANSwitch
WS WS
E1
WSIU/WSMU WSIU/WSMU
BUS SSM
Page 37
The Calling Control Unit/Calling Control and Signaling process Unit WCCU/WCSU (WCCU/WCSU) is responsible for call control and protocol processing of MTP3, MTP3b, M3UA, ISUP, BSSAP, MAP and CAP.
B S S A P +
I S U P
R A N A P
B S S A P
M A P
C A P
BICC
H.248
TCAP SCCP
WEPI
SAAL
WBSG
Page 38
WCDB
It provides UMG resource management, outgoing trunk selection, and WVDB distribution agent management (MSRN number allocation, WVDB maintenance command forwarding) functions. The WCDB contains global data which can be accessed by all WCCUs/WCSUs and WVDBs. Because the WCDB is an accessed center, its load is relatively large. In small-capacity configuration mode, its functions can be implemented by one pair of WCDBs. In a large-capacity configuration mode, different functions must be distributed to different WCDBs.
Page 39
WVDB
The VLR Database Board (WVDB) is a front board used to store the subscription data of mobile subscribers. In a large-capacity application, multiple pairs of WVDBs are required to store the subscription data. The subscription information of one subscriber is stored in the same pair of WVDBs. The principles for distributing subscriber data on different WVDBs have been described in the Section about WCDB (also named WVDB distribution agent function). Such distribution is transparent for the WCCU/WCSU service layer.
Page 40
WMGC
WMGC provides gateway registration, internal link status maintenance, gateway status and capability auditing, and gateway exception handling functions.
Page 41
Page 42
WALU&UPWR
The Alarm Unit (WALU) is a front board installed fixedly in slot 16 in each MSC SERVER UNIT frame. Its functions are as follows:
Acting as a slave node, communicating with the master node (WSMU) through serial port bus, and controlling indicator under the instructions of the WSMU.
UPWR
It is used to provide power supply to the boards in the MSC SERVER UNIT frames. The UPWR works in 2+2 backup mode.
Page 43
Page 44
W E P I
W E P I
W S I U
W H S C
W S I U
W H S C
W C S U
W C S U
W S M U
W S M U
W C C U
W C C U
FRAME A
Page 45
Service_change
W B F I
W B F I
W S I U
W H S C
W S I U
W H S C
Other Message
W I F M W I F M W B S G W B S G W S M U W S M U W M G C W M G C W C C U W C C U
Ethernet Bus
FRAME A
Page 46
Service_change
W B A I
W B A I
W S I U
W H S C
W S I U
W H S C
Other message
W A F M W A F M W B S G W B S G W S M U W S M U W M G C W M G C W C C U W C C U
Ethernet Bus
FRAME A
Page 47
Review
Page 48
B I T S 1
B I T S 0
E1
W C K I
W C K I
W E P I
W E P I
Basic frame
H.110 BUS
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 49
Basic frame
W C K I
W C K I
W E P I
W E P I
Expansion frame
W E P I
W E P I
W E P I
W E P I
H.110 BUS
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 50
Alarm Path
W B A I W B F I W S I U W H S C W S I U W H S C
Back Board Back Board Back Board Back Board Back Board Back Board
U P W R
U P W R
Back Board
Back Board
W A F M
W I F M
W S M U S
W S M U M
W A L U
U P W R
U P W R
BAM
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 51
Loading Path
BAM
LANSwitch
LANSwitch
W H S C
W H S C
W S M U
Page 52
Charging Path
L A N
iGWB
Page 53
Questions
How many boards are there in MSOFTX3000? Whats the function of each board?
Page 54
Chapter 1 MSOFTX3000 Outline Chapter 2 Board Function Chapter 3 Concatenation and Cables
Page 55
LAN Switch
LAN Switch
Page 56
Page 57
Server/Switcher Cables
Server/switcher cables include keyboard cable, mouse cable and display cable delivered along with the device. The connection relations are BAM-PC1, iGWB0-PC2 and iGWB1-PC3.
KVM/LCD switcher
PC4
PC3
PC2
PC1
BAM
iGWB1
iGWB0
Page 58
BITS
BITS
W C K I (M)
W C K I (S)
W E P I (M)
8k CLOCK CABLE
8k CLOCK CABLE
W W E E P P I I (M) (S)
W W E E P P I I (M) (S)
SERVICE FRAME HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 59
Page 60
WCKI
BITS 1 BITS 2 LINE 1 LINE 2
1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16
BITS1
BITS2
Page 61
Page 62
Page 63
Page 64
Summary
Review
Page 65
Thank You