DU-120 TRUSS CALCULATION

SECTION 17

Construccin

DU-120 TRUSS CALCULATION-SECTION 17

1. INTRODUCTION................................................................
................................................................................................
......................................................................
...................................... 3
2. APPLIED LOADS ................................................................
................................................................................................
......................................................................
...................................... 3
2.1. STRUCTURE SELFWEIGHT..................................................................................................... 3
2.2. FORMWORK WEIGHT (TIMBER BEAMS AND PLYWOOD) ............................................................. 4
2.3. CONCRETE LOAD............................................................................................................... 4
2.4. CONCRETE OVERLOAD........................................................................................................ 5
2.5. CONSTRUCTION OVERLOAD ................................................................................................. 5

3. RESULTS ................................................................
................................................................................................
................................................................................
................................................ 6
3.1. RESISTANCE ..................................................................................................................... 6
3.2. DEFLECTIONS ................................................................................................................... 6
3.3. REACTIONS ...................................................................................................................... 7

Construccin

2/ 7

DU-120 TRUSS CALCULATION-SECTION 17

1. INTRODUCTION
In this report the calculation of the truss drawn below is shown. A span between trusses of 0.6m has been
considered.

2. APPLIED LOADS
2.1. Structure selfweight

Construccin

3/ 7

DU-120 TRUSS CALCULATION-SECTION 17

2.2. Formwork weight (Timber beams and plywood)

2.3. Concrete load

Construccin

4/ 7

DU-120 TRUSS CALCULATION-SECTION 17

2.4. Concrete overload

2.5. Construction overload

Construccin

5/ 7

DU-120 TRUSS CALCULATION-SECTION 17

3. RESULTS
3.1. Resistance
Maximum 57.17%.

3.2. Deflections
Maximum 4mm.

Construccin

6/ 7

DU-120 TRUSS CALCULATION-SECTION 17

3.3. Reactions
RMax=76.07 kN.

Construccin

7/ 7