Download as pdf or txt
Download as pdf or txt
You are on page 1of 62

SMART

power design

ENATEL | 2010 PRODUCT CATALOGUE


We are specialists in the design and manufacture of a range of standby power solutions for the telecom, networking, wireless and industrial markets. Enatels smart power design offers intelligent solutions at an empowering price. In a market where only the fast survive, we respond quickly and cost-effectively so our customers can do the same.

Offering a range of solutions from small standalone systems for applications like access nodes to medium systems for radio base stations for mobile networks and larger systems for central ofce power applications. Our knowledge and experience of the global marketplace, along with our talented team, enable us to create power supply solutions that meet each customers unique specications no matter what volume they require.

We not only create our own suite of products, we also offer a comprehensive contract manufacturing service. Our highly exible environment allows us to specialize in small to medium volume as well as highly repetitive production.

AC-DC POWER SYSTEMS........................................................................... 4


1U MICRO COMPACT SYSTEM 0.8 - 2.4kW 48V DC........................................ 5 1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC........................................ 6 1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC........................................ 7 2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC........................................ 8 2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC........................................ 9 2U ULTRA COMPACT SYSTEM 1.0 - 8.0kW 48V DC...................................... 10 3U COMPACT SYSTEM 1.0 - 6.0kW 48V DC................................................... 11 3U COMPACT SYSTEM 1.0 - 6.0kW 48V DC................................................... 12 3U COMPACT SYSTEM 1.0 - 8.0kW 48V DC................................................... 13 5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC....................................... 14 5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC....................................... 15 5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC....................................... 16 6U MAXI COMPACT SYSTEM 1.0 - 22.0kW 48V DC....................................... 17 15U MEDIUM SYSTEM 3.0 - 27.0kW 48V DC.................................................. 18 2.0M MEDIUM SYSTEM 3.0 - 54.0kW 48V DC. ................................................ 19 2.2M INTEGRATED BASE TRANSCEIVER STATION SYSTEM 1.0 - 16.0kW 48V DC......................................................... 20 1.6M MEDIUM SYSTEM 3.0 - 27.0kW 48V DC. ................................................ 21 2.0M LARGE DATA CENTER SOLUTIONS....................................................... 22 WALL MOUNT SYSTEM 4.0kW 48V DC / 2.1kW 24V DC................................ 23

FLAT MOUNT RECTIFIERS........................................................................ 34


RF SERIES FLAT MOUNT RECTIFIERS. ........................................................... 35

WALL MOUNT RECTIFIERS....................................................................... 36


RW SERIES WALL MOUNT RECTIFIERS......................................................... 37

DC-AC POWER SYSTEMS......................................................................... 38 DC-AC INVERTERS...................................................................................... 39


IM SERIES MODULAR INVERTERS. ................................................................. 40 SBM SERIES STATIC BYPASS MODULE........................................................ 41

DC-DC CONVERTERS. ............................................................................... 42


CM SERIES 1.7kW MODULAR DC-DC CONVERTERS.................................... 43 CM SERIES 500W to 1.0kW MODULAR DC-DC CONVERTERS..................... 44

MONITORING................................................................................................ 45
SM36 SUPERVISORY MODULE....................................................................... 46 SM35 SUPERVISORY MODULE....................................................................... 47 SM32 SUPERVISORY MODULE....................................................................... 48 SM31 SUPERVISORY MODULE....................................................................... 49 SM11 SUPERVISORY MODULE....................................................................... 50 FAN CONTROLLER BOARD............................................................................. 50 BATTERY CONDITION MONITOR.................................................................... 51 AC MAINS MONITOR. ....................................................................................... 51

MODULAR RECTIFIERS.............................................................................. 24
RM3048 3.0kW 48V DC MODULAR RECTIFIER. .............................................. 25 RM3048/24 3.0kW 48V DC / 1.7kW 24V DC MODULAR RECTIFIER. .............. 26 RM3060/48 3.0kW 60/48V DC MODULAR RECTIFIER.................................... 27 RM2324 2.3kW 24V DC MODULAR RECTIFIER. .............................................. 28 RM2048XP 2.0KW 48V DC MODULAR RECTIFIER. ......................................... 29 RM2048/24 2.0kW 48V DC / 1.0kW 24V DC MODULAR RECTIFIER. .............. 30 RM1860/48 1.8kW 60/48V DC MODULAR RECTIFIER.................................... 31 RM1048 1.0kW 48V DC MODULAR RECTIFIER. .............................................. 32 RM848 800W 48V DC MODULAR RECTIFIER. ................................................. 33

FTTX POWER SOLUTIONS........................................................................ 52


nSURE 1U MICRO COMPACT SYSTEM 0.8 - 2.4KW 48V DC......................... 53 ............................................................................................. 54 nSURE NS300-12. ............................................................................................... 55 nSURE NS30-12.

INDUSTRIAL SOLUTIONS.......................................................................... 56
2U ULTRA COMPACT SYSTEM 3.0 - 6.0kW 110V DC.................................... 57 WALL MOUNT BATTERY CHARGER 3.0kW 110V DC..................................... 58 RM30110 3.0KW 110V DC MODULAR RECTIFIER.......................................... 59 SM34 SUPERVISORY MODULE....................................................................... 60 SM33 SUPERVISORY MODULE....................................................................... 61
ENATEL | 2010 PRODUCT CATALOGUE | 3

AC-DC POWER SYSTEMS


- World leading power density. - Fully featured telecom grade rectiers. - Network monitoring available. - Modular 19 design for ease of installation. - Includes AC surge protection. - More room for revenue creating equipment. to higher power. of maintenance. means less site visits and less cost. - Upgrade existing systems - High reliability means less cost - Full remote monitoring available - Cost competitive. - Suitable for more harsh environments. For details on a Enatel power system that meets your requirements contact us. They are the ideal solution for powering telecommunications and data networks requiring 24V, 48V or 60V DC. We offer a range of solutions for applications from small standalone systems for applications like access nodes to medium sized systems for radio base stations for mobile networks to larger systems for central ofce power applications. Systems are congured using Enatels state of the art high frequency switch mode rectier modules, intelligent network capable controllers, AC & DC distribution modules, and cabinets, and can be customized and congured to meet individual customer requirements. Our DC power systems are designed to meet the requirements of telecommunications applications requiring high reliability and optimum performance with easy expansion by way of hot pluggable modular rectiers.

 | ENATEL | 2010 PRODUCT CATALOGUE

1U MICRO COMPACT SYSTEM 0.8 - 2.4kW 48V DC


AC Input: AC Current: Frequency Range: Power Factor: Termination: Single phase. 170V AC, 15.0A max. 230V AC, 11.1A nominal. (refer to RM8xx, series brochures for full details) 45-66Hz >0.99 (full load) Single phase, 1.5m flying lead.

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: Load: Battery: 2x 10A, 2x 20A load circuit breakers. 2x 30A battery circuit breakers. Electronic fail detection on both load and battery breakers.
Supervisory Module

-48V 2400W max. (50A @ -48V; 44.4A @ -54.0V) Positive earth. (negative earth available to special order).

48 2.4
RM848 RM848 RM848

nominal output voltage.

maximum output power.

kW

SM36

Breaker Fail Detection: DC Terminals (Front Connected): Load: Battery:

6mm push-in spring cage. 55A power-pole plug-in connectors. 50A battery LVD (magnetically latching) fitted as standard.

Low Voltage Disconnect:

Mechanical Dimensions, W,H,D: Weight: 482.6mm (standard 19 module), also fits ETSI 515mm mounting cabinet, 44.45mm (1U, 1.75), 285mm (11.6) 5kg (excluding rectifier modules)

Shipping Dimensions, W,H,D: 540mm, 95mm, 400mm Weight: 6kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM35/36 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/ equalisation, 6x general purpose inputs and 6x voltage-free relay alarm outputs. For further details, refer to the SM35/36 series of brochures.

Accessories ACA-BC08P2: 2m, 8mm battery cable kit. (other lengths available to special order)

Part Numbers: PSX1606211F-000: PSX1606221F-000: PSX2404211F-000: PSX2404221F-000:

Actual part numbers will vary with configuration. Micro compact system, 2x 800W 48V rectifiers, 6x load 2x battery MCBs, front termination, SM35 supervisory module. Micro compact system, 2x 800W 48V rectifiers, 6x load 2x battery MCBs, front termination, SM36 supervisory module. Micro compact system, 3x 800W 48V rectifiers, 4x load 2x battery MCBs, front termination, SM35 supervisory module. Micro compact system, 3 x 800W 48V rectifiers, 4x load 2x battery MCBs, front termination, SM36 supervisory module.
ENATEL | 2010 PRODUCT CATALOGUE | 

1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC

48 4.0
nominal output voltage.

AC Input: Frequency Range: Power Factor: Termination:

Single phase. (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Single phase, 10mm L, N, E tunnel terminals.

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: Load: 1x 63A load circuit breaker. (1x 50A load circuit breaker. Low power option.) 1x 63A battery circuit breaker. (1x 50A battery circuit breaker. Low power option.) Electronic fail detection on both load and battery breakers. Tunnel terminals, 10mm. 80A battery LVD fitted as standard. (50A battery LVD fitted as standard. Low power option.) -48V (+24V available to special order) 4000W @ -48V (2000W @ -48V. Low power option.) Positive earth. (negative earth available to special order)

maximum output power.

kW


Supervisory Module

Battery:

SM32

Load

Battery

compact

ULTRA

Breaker Fail Detection: DC Terminals: Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 44.45mm (1U, 1), 350mm (13) 5kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 540mm, 95mm, 400mm Weight: 6kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSC04020110-000: PSC04020111-000: PSC04020120-000: PSC04020121-000: PSC02020110-000: PSC02020111-000: PSC02020120-000: PSC02020121-000:
 | ENATEL | 2010 PRODUCT CATALOGUE

Actual part numbers will vary with configuration. 1U Ultra Compact System including standard SM31 supervisory module. 1U Ultra Compact System including standard SM31 supervisory module and I/O expansion card. 1U Ultra Compact System including standard SM32 supervisory module. 1U Ultra Compact System including standard SM32 supervisory module and I/O expansion card. Low Power 1U Ultra Compact System including standard SM31 supervisory module. Low Power 1U Ultra Compact System including standard SM31 supervisory module and I/O expansion card. Low Power 1U Ultra Compact System including standard SM32 supervisory module. Low Power 1U Ultra Compact System including standard SM32 supervisory module and I/O expansion card.

1U ULTRA COMPACT SYSTEM 1.0 - 4.0kW 48V DC


AC Input: Frequency Range: Power Factor: Termination: Single phase. (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Single phase, 6mm L, N, E tunnel terminals.

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: Load: 3x 20A load circuit breakers. (3x 10A load circuit breakers. Low power option.) 2x 30A battery circuit breakers. (2x 20A battery circuit breakers. Low power option.) Electronic fail detection on both load and battery breakers.
Supervisory Module

-48V, -60V (+24V available to special order) 4000W @ -48V (2000W @ -48V. Low power option.) Positive earth. (negative earth available to special order)

Battery:

48 4.0
SM32

nominal output voltage.

maximum output power.

kW

Breaker Fail Detection: DC Terminals: Live: Common:

compact

ULTRA

Tunnel terminals, 6mm Tunnel terminals, 6mm 80A battery LVD fitted as standard. (50A battery LVD fitted as standard. Low power option.)

Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 44.45mm (1U, 1), 350mm (13) 5kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 540mm, 95mm, 400mm Weight: 6kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSC04020110-100: PSC04020111-100: PSC04020120-100: PSC04020121-100: PSC02020110-100: PSC02020111-100: PSC02020120-100: PSC02020121-100:

Actual part numbers will vary with congifuration. 1U Ultra Compact System including standard SM31 supervisory module. 1U Ultra Compact System including standard SM31 supervisory module and I/O expansion card. 1U Ultra Compact System including standard SM32 supervisory module. 1U Ultra Compact System including standard SM32 supervisory module and I/O expansion card. Low Power 1U Ultra Compact System including standard SM31 supervisory module. Low Power 1U Ultra Compact System including standard SM31 supervisory module and I/O expansion card. Low Power 1U Ultra Compact System including standard SM32 supervisory module. Low Power 1U Ultra Compact System including standard SM32 supervisory module and I/O expansion card.
ENATEL | 2010 PRODUCT CATALOGUE | 

2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC

48 6.0
nominal output voltage.

AC Input: Frequency Range: Power Factor: Termination: DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: Load: Battery:

Three phase or single phase. (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Three phase, 6mm L1, L2, L3, N, E tunnel terminals. (Single phase by linking L1, L2, L3 terminals)

-48V, -60V (+24V available to special order) 6000W @ -48V (3000W @ -48V. Low power option) Positive earth. (negative earth available to special order) 2x 10A, 2x 20A, 2x 32A load circuit breakers. (2x 6A, 2x 10A, 2x 20A load circuit breakers. Low power option.) 2x 63A battery circuit breakers. (2x 63A battery circuit breakers. Low power option.) Electronic fail detection on both load and battery breakers. Tunnel terminals, 16mm (rear connected) Tunnel terminals, 35mm (rear connected) 125A battery LVD fitted as standard. (magnetically latching contactor) (80A battery LVD fitted as standard. Low power option)

maximum output power.

kW


1 Load 2
Supervisory Module

3 Load 4
SM32

5 Load 6

1 Battery 2

compact

ULTRA

Breaker Fail Detection: DC Terminals: Load: Battery:

Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: Weight: Monitoring & Control: Part Numbers: PSC06030210-000: PSC06030211-000: PSC06030220-000: PSC06030221-000: PSC03030210-000: PSC03030211-000: PSC03030220-000: PSC03030221-000:
 | ENATEL | 2010 PRODUCT CATALOGUE

482.6mm (standard 19 module), 89mm (2U, 3), 350mm (13) (390mm with cable strain relief) 9kg (excluding rectifier modules) 10.5kg (excluding rectifier modules) Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures. Actual part numbers will vary with congifuration. 2U Ultra Compact System including standard SM31 supervisory module. 2U Ultra Compact System including standard SM31 supervisory module and I/O expansion card. 2U Ultra Compact System including standard SM32 supervisory module. 2U Ultra Compact System including standard SM32 supervisory module and I/O expansion card. Low Power 2U Ultra Compact System including standard SM31 supervisory module. Low Power 2U Ultra Compact System including standard SM31 supervisory module and I/O expansion card. Low Power 2U Ultra Compact System including standard SM32 supervisory module. Low Power 2U Ultra Compact System including standard SM32 supervisory module and I/O expansion card.

Shipping Dimensions, W, H, D: 540mm, 150mm, 435mm

2U ULTRA COMPACT SYSTEM 1.0 - 6.0kW 48V DC


AC Input: Frequency Range: Power Factor: Termination: DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: Load: Battery: 8x 10A, 4x 20A, 4x 30A load circuit breakers. (8x 6A, 4x 10A, 4x 20A load circuit breakers. Low power option.) 2x 100A battery circuit breakers. (2x 50A battery circuit breakers. Low power option.) Electronic fail detection on both load and battery. breakers
Supervisory Module

Three phase or single phase. (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Three phase, 6mm L1, L2, L3, N, E tunnel terminals. (Single phase by linking L1, L2, L3 terminals)

-48V, -60V (+24V available to special order) 6000W @ -48V (3000W @ -48V. Low power option.) Positive earth. (negative earth available to special order)

Breaker Fail Detection: DC Terminals (rear connected): Load:

48 6.0
1 Battery 2
SM32

nominal output voltage.

maximum output power.

kW

compact

ULTRA

10A, 6mm tunnel terminals. 20A & 30A, 10mm tunnel terminals. (6A & 10A, 6mm tunnel terminals. 20A, 10mm tunnel terminals. Low power option.) 100A, 35mm tunnel terminals. (50A, 16mm tunnel terminals. Low power option.) 125A battery LVD fitted as standard. (80A battery LVD fitted as standard. Low power option.)

Battery: Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: Weight: Monitoring & Control: Part Numbers: PSC06030210-100: PSC06030211-100: PSC06030220-100: PSC06030221-100: PSC03030210-100: PSC03030211-100: PSC03030220-100: PSC03030221-100: 482.6mm (standard 19 module), 89mm (2U, 3), 350mm (13) (390mm with cable strain relief) 9kg (excluding rectifier modules) 10.5kg (excluding rectifier modules) Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures. Actual part numbers will vary with congifuration. 2U Ultra Compact System including standard SM31 supervisory module. 2U Ultra Compact System including standard SM31 supervisory module and I/O expansion card. 2U Ultra Compact System including standard SM32 supervisory module. 2U Ultra Compact System including standard SM32 supervisory module and I/O expansion card. Low Power 2U Ultra Compact System including standard SM31 supervisory module. Low Power 2U Ultra Compact System including standard SM31 supervisory module and I/O expansion card. Low Power 2U Ultra Compact System including standard SM32 supervisory module. Low Power 2U Ultra Compact System including standard SM32 supervisory module and I/O expansion card.
ENATEL | 2010 PRODUCT CATALOGUE | 

Shipping Dimensions, W, H, D: 540mm, 150mm, 435mm

2U ULTRA COMPACT SYSTEM 1.0 - 8.0kW 48V DC

48 8.0
nominal output voltage.

AC Input: Frequency Range: Power Factor: Termination:

Three phase or single phase. (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Three phase, 10mm L1, L2, L3, N tunnel terminals, 16mm E tunnel terminal. (Single phase by linking L1, L2, L3 terminals)

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: -48V, -60V (+24V available to special order) 8000W @ -48V Positive earth. (negative earth available to special order)

maximum output power.

kW

Supervisory Module

SM32

1 Load 2

3 Load 4

1 Battery 2

compact

ULTRA

Load: Battery:

2x 20A, 2x 63A load circuit breakers. 2x 100A battery circuit breakers. Electronic fail detection for load breakers. Auxiliaries for battery MCB fail detection.

Breaker Fail Detection: DC Terminals: Load: Battery:

Tunnel terminals, 16mm (rear connected) Tunnel terminals, 35mm (rear connected) 150A battery LVD fitted as standard. (magnetically latching contactor)

Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 89mm (2U, 3), 350mm (13) (390mm with cable strain relief) 9kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 483mm, 88.9mm, 350mm Weight: 10.5kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSC08040210-000: PSC08040211-000: PSC08040220-000: PSC08040221-000:


10 | ENATEL | 2010 PRODUCT CATALOGUE

Actual part numbers will vary with congifuration. 2U Ultra Compact System including standard SM31 supervisory module. 2U Ultra Compact System including standard SM31 supervisory module and I/O expansion card. 2U Ultra Compact System including standard SM32 supervisory module. 2U Ultra Compact System including standard SM32 supervisory module and I/O expansion card.

3U COMPACT SYSTEM 1.0 - 6.0kW 48V DC


AC Input: Frequency Range: Power Factor: Termination: Three phase or single phase. (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Three phase L1, L2, L3, N, E 10mm terminal blocks. (Single phase by linking line terminals)

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: -48V, -60V (+24V available to special order) 6000W @ -48V Positive earth. (negative earth available to special order)

48 6.0
3U Compact System 1 2 3 5 6 7 8 9 10 11 12 1 Battery 2 Load Load 4
Supervisory Module

nominal output voltage.

maximum output power.

kW

Load: Battery:

4x 10A, 4x 20A, 4x 32A load circuit breakers. 2x 100A battery circuit breakers.
SM32

Breaker Fail Detection: DC Terminals (rear connected): Load: Battery:

Electronic fail detection on both load and battery breakers.

16mm tunnel terminals. 35mm tunnel terminals. 125A battery LVD fitted as standard.

Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 133.3mm (3U, 5), 350mm (13) (390mm with cable strain relief) 11kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 540mm, 200mm, 435mm Weight: 14kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSC06030310-000: PSC06030311-000: PSC06030320-000: PSC06030321-000:

Actual part numbers will vary with congifuration. 3U Compact System including standard SM31 supervisory module. 3U Compact System including standard SM31 supervisory module and I/O expansion card. 3U Compact System including standard SM32 supervisory module. 3U Compact System including standard SM32 supervisory module and I/O expansion card.
ENATEL | 2010 PRODUCT CATALOGUE | 11

3U COMPACT SYSTEM 1.0 - 6.0kW 48V DC

48 6.0
nominal output voltage.

AC Input: Frequency Range: Power Factor: Termination: Proctection:

Three phase or single phase. (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Three phase L1, L2, L3, N, E 6mm2 terminal blocks. (Single phase by linking line terminals) 20A circuit breaker provided per rectifier.

DC Output

maximum output power.

kW

Nominal Voltage: Rated System Output Power: Polarity: DC Distribution:

-48V, -60V (+24V available to special order) 6000W @ -48V Positive earth. (negative earth available to special order)

Rectifiers

1 2 3 1 2 3
Supervisory Module

4 5 6 7 Load

10 11 12 13 14 15 Load

3U Compact System

AC Input

Battery

Load: Battery:

5x 10A, 4x 20A, 4x 32A load circuit breakers. 2x 100A battery circuit breakers. Electronic fail detection on both load and battery breakers.

Load

8 9

SM32

Breaker Fail Detection: DC Terminals (rear connected): Load:

10A, 6mm tunnel terminals. 32A, 10mm tunnel terminals. 50A, 16mm tunnel terminals. 35mm tunnel terminals. 125A battery LVD fitted as standard.

Battery:

Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 133.3mm (3U, 5), 350mm (13) (390mm with cable strain relief) 11.5kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 540mm, 200mm, 435mm Weight: 14.5kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSC06030310-200: PSC06030311-200: PSC06030320-200: PSC06030321-200:


12 | ENATEL | 2010 PRODUCT CATALOGUE

Actual part numbers will vary with congifuration. 3U Compact System including standard SM31 supervisory module. 3U Compact System including standard SM31 supervisory module and I/O expansion card. 3U Compact System including standard SM32 supervisory module. 3U Compact System including standard SM32 supervisory module and I/O expansion card.

3U COMPACT SYSTEM 1.0 - 8.0kW 48V DC


AC Input: Frequency Range: Power Factor: Termination: Three phase or single phase. (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Single phase L, N, E 16mm terminal blocks Single phase surge protection. (40KA 8/20sec) (Three phase without surge protection available to special order)

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: Load: Battery: 2x 10A, 2x 20A, 4x 32A load circuit breakers. 2x 100A battery circuit breakers. Electronic fail detection on both load and battery breakers.
AC Input

-48V, -60V (+24V available to special order) 8000W @ -48V Positive earth. (negative earth available to special order)
Supervisory Module

48 8.0
SM32

nominal output voltage.

maximum output power.

kW

3U Compact System 1 2 SPD Input MCB 3 4 5 6 7 8 1 Battery 2

Load

Breaker Fail Detection: DC Terminals (rear connected): Load: Battery:

16mm tunnel terminals. 35mm tunnel terminals. 150A battery LVD fitted as standard.

Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 133.3mm (3U, 5), 350mm (13) (390mm with cable strain relief) 11kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 483mm, 133.35mm, 350mm Weight: 11.5kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSC08040310-000: PSC08040311-000: PSC08040320-000: PSC08040321-000:

Actual part numbers will vary with congifuration. 3U Compact System including standard SM31 supervisory module. 3U Compact System including standard SM31 supervisory module and I/O expansion card. 3U Compact System including standard SM32 supervisory module. 3U Compact System including standard SM32 supervisory module and I/O expansion card.
ENATEL | 2010 PRODUCT CATALOGUE | 13

5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC

48 14.0
nominal output voltage.

AC Input: Frequency Range: Power Factor: Termination:

Three phase (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Three phase L1, L2, L3, N, E 10mm terminal blocks. Surge protection. (40kA 8/20msec)

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: -48V, -60V (+24V available to special order) 14000W @ -48V DC Positive earth. (negative earth available to special order)

maximum output power.

kW

5U Compact System

AC Input

10

Battery


3 4

Load: Battery:

2x 10A, 6x 32A, 2x 50A load circuit breakers. 4x 100A battery circuit breakers. Electronic fail detection on both load and battery breakers.

Load

Supervisory Module

SM32

Breaker Fail Detection: DC Terminals (rear connected): Load: Battery:

16mm tunnel terminals. 35mm tunnel terminals. 300A battery LVD fitted as standard.

Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 222.2mm (5U, 8), 350mm (13) (390mm with cable strain relief) 14kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm Weight: 18kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage- free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSC12070510-000: PSC12070511-000: PSC12070520-000: PSC12070521-000:


14 | ENATEL | 2010 PRODUCT CATALOGUE

Actual part numbers will vary with congifuration. 5U Maxi Compact System including standard SM31 supervisory module. 5U Maxi Compact System including standard SM31 supervisory module and I/O expansion card. 5U Maxi Compact System including standard SM32 supervisory module. 5U Maxi Compact System including standard SM32 supervisory module and I/O expansion card.

5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC


AC Input: Frequency Range: Power Factor: Termination: Three phase. (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Three phase L1, L2, L3, N, E 16mm terminal blocks.

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: Load: Battery: 6x 10A, 4x 20A, 4x 32A, 4x 50A load circuit breakers. 4x 100A battery circuit breakers. Electronic fail detection on both load and battery breakers.
1

-48V, -60V (+24V available to special order) 14000W @ -48V Positive earth. (negative earth available to special order)

48 14.0
5U Compact System
Battery Load 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Supervisory Module

nominal output voltage.

maximum output power.

kW

Breaker Fail Detection: DC Terminals: Load: Battery:

SM32

16mm tunnel terminals. 35mm tunnel terminals. 300A battery LVD fitted as standard. (option 2x LVDs)

Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 222.2mm (5U, 8), 350mm (13) (390mm with cable strain relief) 14kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm Weight: 18kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSC12070510-001: PSC12070511-001: PSC12070520-001: PSC12070521-001:

Actual part numbers will vary with congifuration. 5U Maxi Compact System including standard SM31 supervisory module. 5U Maxi Compact System including standard SM31 supervisory module and I/O expansion card. 5U Maxi Compact System including standard SM32 supervisory module. 5U Maxi Compact System including standard SM32 supervisory module and I/O expansion card.
ENATEL | 2010 PRODUCT CATALOGUE | 15

5U MAXI COMPACT SYSTEM 1.0 - 14.0kW 48V DC

48 14.0
nominal output voltage.

AC Input: Frequency Range: Power Factor: Termination:

Three phase (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Three phase L1, L2, L3, N, E, 16mm terminal blocks

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: -48V, -60V (+24V available to special order) 14000W @ -48V Positive earth (negative earth available to special order)

maximum output power.

kW

5U Compact System


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Battery

Load: Battery:

6x 10A, 4x 20A, 6x 32A, 4x 50A load circuit breakers 4x 100A battery circuit breakers Electronic fail detection on both load and battery breakers

AC Input


3 4

Load

Breaker Fail Detection: DC Terminals: Load: Battery:

Supervisory Module

SM32

16mm tunnel terminals 35mm tunnel terminals 300A battery LVD fitted as standard

Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 222.2mm (5U, 8), 350mm (13) (390mm with cable strain relief) 15kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm Weight: 18kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSC12070510-200: PSC12070511-200: PSC12070520-200: PSC12070521-200:


16 | ENATEL | 2010 PRODUCT CATALOGUE

Actual part numbers will vary with congifuration. 5U Maxi Compact System including standard SM31 supervisory module. 5U Maxi Compact System including standard SM31 supervisory module and I/O expansion card. 5U Maxi Compact System including standard SM32 supervisory module. 5U Maxi Compact System including standard SM32 supervisory module and I/O expansion card.

6U MAXI COMPACT SYSTEM 1.0 - 22.0kW 48V DC


AC Input: Frequency Range: Power Factor: Termination: Three phase. (refer to RM series brochures for full details) 45-66Hz >0.99 (full load) Three phase L1, L2, L3, N, E 10mm terminal blocks. Surge protection. (40kA 8/20msec)

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: Load: Battery: 2x 20A, 4x 32A, 4x 63A load circuit breakers. 4x 100A battery circuit breakers. Electronic fail detection on both load and battery breakers. -48V, -60V (+24V available to special order) 22000W @ -48V DC Positive earth. (negative earth available to special order)

48 22.0
6U Compact System AC Input
1 2 3 4 5 6 7 8 9 10 Battery Load 1 2 3 4
Supervisory Module

nominal output voltage.

maximum output power.

kW

Breaker Fail Detection: DC Terminals (rear connected): Load: Battery:

20A, 32A, 63A, 16mm tunnel terminals. 35mm tunnel terminals. 500A battery LVD fitted as standard.
SM32

Low Voltage Disconnect:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 266.7mm (6U, 10), 350mm (13) (390mm with cable strain relief) 21kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 540mm, 350mm, 435mm Weight: 30kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSC22110610-000: PSC22110611-000: PSC22110620-000: PSC22110621-000: PSC22110610-F00: PSC22110611-F00: PSC22110620-F00: PSC22110621-F00:

Actual part numbers will vary with congifuration. 6U Maxi Compact System including standard SM31 supervisory module. 6U Maxi Compact System including standard SM31 supervisory module and I/O expansion card. 6U Maxi Compact System including standard SM32 supervisory module. 6U Maxi Compact System including standard SM32 supervisory module and I/O expansion card. 6U Front Terminal Maxi Compact System including standard SM31 supervisory module.* 6U Front Terminal Maxi Compact System including standard SM31 supervisory module and I/O expansion card.* 6U Front Terminal Maxi Compact System including standard SM32 supervisory module.* 6U Front Terminal Maxi Compact System including standard SM32 supervisory module and I/O expansion card.* *for front terminal systems a minimum of 3U height above the 6U system is recommended for load and battery cabling.
ENATEL | 2010 PRODUCT CATALOGUE | 17

15U MEDIUM SYSTEM 3.0 - 27.0kW 48V DC

48 27.0
nominal output voltage.

AC Input AC Input Range: Maximum Input Current: Frequency Range: Power Factor: Style: Surge Protection: In(8/20S): Imax(8/20S): 312-500V AC (full power output) 156-312V AC (reduced output power) 60A/ph (ph-N) 45-66Hz >0.99 (full power) 3-phase neutral and earth. MOV; 3x Ph-N, 1x N-Earth. 20kA 40kA

maximum output power.

kW

DC Output Nominal System Output Voltage: Maximum Power Output: Polarity: Load & Battery Distribution: Low Voltage Disconnect Options: LVD Current Rating: -48V 27000W Positive earth. (standard) 16x load positions for 18mm wide circuit breakers, plus 4x battery breakers up to 125A each. May be arranged in different configurations of load and battery breakers. Fuse options also available. (options) Single battery LVD fitted as standard. Up to 2x LVDs with independent control may be fitted on battery or load side. (option) 600A web based viewing & configuration. (option) Door mounted for improved system terminal access. Optional full battery monobloc monitoring. (bloc voltage & string current) 1x fixed alarm - Monitor failed Up to 9x user configurable, 2 of which are pre-programmed: - Non-urgent summary alarm - Urgent summary alarm 7x unassigned, may be assigned to any one of 37 alarm events, (e.g. rectifier fail, mains fail etc.) on an AND or OR basis Contacts rated for 1A at 60V DC

Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled for Supervisory Module Mounting: Battery Condition Monitoring: Alarms (voltage free contacts): Environmental Requirements Temperature: Humidity: Altitude: Mechanical Dimensions W, D, H: Weight: Shipping Size L, W, H Shipping weight: Compliances Safety: Part Numbers:
18 | ENATEL | 2010 PRODUCT CATALOGUE

-10C to +70C (max. power de-rated above 50C) 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

600mm (23 ) , 19 standard mounting rails 450mm (17 ), 800mm (31 ) providing 15U of rack space. 75kg (approx) 900mm x 700mm x 550mm 80kg (approx)

EN60950 Actual part numbers will vary with congifuration. Contact us for further details on a solution that suits your requirements.

1.6M MEDIUM SYSTEM 3.0 - 27.0kW 48V DC


AC Input AC Input Range: Maximum Input Current: Frequency Range: Power Factor: Style: Surge Protection: In(8/20S): Imax(8/20S): 312-500V AC (full power output) 156-312V AC (reduced output power) 54A/ph (ph-N) 45-66Hz >0.99 (full power) 3-phase neutral and earth. MOV; 3x Ph-N, 1x N-Earth. (spark gap) 20kA 40kA

DC Output Nominal System Output Voltage: Maximum Power Output: Polarity: Load Distribution: Priority: Non-Priority: 6x 18mm MCBs. 5x 18mm MCBs, 2x 100A DIN00 fuses, 2x 160A DIN00 fuses. 2x 400A DIN02 fuses. 2x LVDs with independent control on load side. 400A 200A web based viewing & configuration. (option) Door mounted for improved system terminal access. Optional full battery monobloc monitoring. (bloc voltage & string current) 1x fixed alarm Monitor failed Up to 9x user configurable, 2 of which are pre-programmed: - Non-urgent summary alarm - Urgent summary alarm 7x unassigned, may be assigned to any one of 37 alarm events, (e.g. rectifier fail, mains fail etc.) on an AND or OR basis. Contacts rated for 1A at 60V DC -48V 27000W Positive earth. (standard)

48 27.0

nominal output voltage.

maximum output power.

kW

Battery Distribution: LVD Options: LVD Rating: Priority: Non-Priority:

Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled for Supervisory Module Mounting: Battery Condition Monitoring: Alarms (voltage free contacts): Environmental Requirements Temperature: Humidity: Altitude: Mechanical Dimensions W, D, H: Weight: Shipping Size L, W, H Shipping weight: Compliances Safety: Part Numbers: EN60950 Actual part numbers will vary with congifuration. Contact us for further details on a solution that suits your requirements.
ENATEL | 2010 PRODUCT CATALOGUE | 19

-10C to +70C (max. power de-rated above 50C) 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

600mm (23.6), 600mm (23.6), 1600mm (63), providing 33U of rack space. 120kg (approx) 1700mm x 720mm x 830mm 130kg (approx)

2.0M MEDIUM SYSTEM 3.0 - 54.0kW 48V DC

48 54.0
nominal output voltage.

AC Input Voltage Range: Maximum Input Current: Frequency Range: Power Factor: Style: Surge Protection: In(8/20S): Imax(8/20S): 312-500V AC (full power output) 156-312V AC (reduced output power) 120A/ph (ph-N) 45-66Hz >0.99 (full power) 3-phase neutral and earth. MOV; 3x Ph-N, 1x N-Earth. 20kA 40kA

maximum output power.

kW

DC Output Nominal System Output Voltage: Maximum Power Output: Polarity: Load & Battery Distribution: Low Voltage Disconnect Options: LVD Current Rating: -48V 54000W Positive earth. (standard) 56x positions for 18mm wide DIN rail mount circuit breakers. May be arranged in many configurations of loads and batteries. Fuse options also available. (options) Single battery LVD fitted as standard. Up to 2x LVDs with independent control may be fitted on battery or load side. (option) 1200A for web based viewing & configuration. (option) Door mounted for improved system terminal access. Optional full battery monobloc monitoring. (bloc voltage & string current) 1x fixed alarm Monitor failed Up to 9x user configurable, 2 of which are pre-programmed: - Non-urgent summary alarm - Urgent summary alarm 7x unassigned, may be assigned to any one of 37 alarm events, (e.g. rectifier fail, mains fail etc.) on an AND or OR basis Contacts rated for 1A at 60V DC

Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled Supervisory Module Mounting: Battery Condition Monitoring: Alarms (voltage free contacts): Environmental Requirements Temperature: Humidity: Altitude: Mechanical Dimensions W, D, H: Weight: Shipping Size L, W, H Shipping weight: Compliances Safety: EN60950 600mm (23.6), 19 standard mounting rails, 600mm (23.6), 2000mm (78 ) 40U of rack space. 180kg (approx) 2100mm, 720mm, 830mm 195kg (approx) -10C to +70C (max. power de-rated above 50C) 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Part Numbers:
20 | ENATEL | 2010 PRODUCT CATALOGUE

Actual part numbers will vary with congifuration. Contact us for further details on a solution that suits your requirements.

2.2M INTEGRATED BASE TRANSCEIVER STATION SYSTEM 1.0 - 16.0kW 48V DC


AC Input AC Input Range: Maximum Input Current: Frequency Range: Power Factor: Style: Surge Protection: In(8/20S): Imax(8/20S): 312-500V AC (full power output) 156-312V AC (reduced output power) 36A/ph (ph-N) 45-66Hz >0.99 (full power) 3-phase neutral and earth. MOV; 3x Ph-N, 1x N-Earth. (spark gap) 20kA 40kA

DC Output Nominal System Output Voltage: Maximum Power Output: Polarity: Load & Battery Distribution: -48V 16000W Positive earth. (standard) 24x load positions for 18mm wide circuit breakers, plus 3x battery breakers up to 100A each. May be arranged in different configurations of load and battery breakers. (option) Single battery LVD fitted as standard. Up to 2x LVDs with independent control may be fitted on load side. (option) 400A

48 16.0

nominal output voltage.

maximum output power.

kW

Low Voltage Disconnect Options:

LVD Current Rating:

Supervisory & Monitoring Module: SM31 (standard) SM32 TCP/IP enabled for web based viewing & configuration. (option) Door mounted for improved system terminal access. RM2048, 48V 2.0kW module.

Supervisory Module Mounting: Rectifier Modules:

Environmental Requirements Temperature: Humidity: Altitude: -10C to +70C (max. power de-rated above 50C) 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Mechanical Dimensions W, D, H: Weight: Shipping Size L, W, H Shipping weight: 600mm (23.6), 600mm (23.6),2200mm (86.6) 1000kg when fitted with 4x strings of 180Ahr batteries. (approx) 2400mm x 720mm x 830mm 180kg (no batteries fitted, approx)

Battery Accommodation Battery Trays: Battery Monobloc Size W, D, H: Up to 4x 180Ahr monoblocs of up to 60kg each per tray. (max. of 250kg per tray) 110mm, 555mm, 288mm

Compliances Safety: EN60950

Part Numbers:

Actual part numbers will vary with congifuration. Contact us for further details on a solution that suits your requirements.
ENATEL | 2010 PRODUCT CATALOGUE | 21

2.0M LARGE DATA CENTER SOLUTIONS

48 54.0
nominal output voltage.

AC Input Voltage Range: Maximum Input Current: Frequency Range: Power Factor: Style: Surge Protection: In(8/20S): Imax(8/20S): 312-500V AC (full power output) 156-312V AC (reduced output power) 120A/ph (ph-N) 45-66Hz >0.99 (full power) 3-phase neutral and earth. MOV; 3x Ph-N, 1x N-Earth. 20kA 40kA

scalable output power.

kW

DC Output Nominal System Output Voltage: Maximum Power Output: Polarity: -48V From 54000W scalable to over 300kW. Positive earth. (standard) Load & Battery Distribution: LVD Options: LVD Current Rating: Monitoring: Environmental Requirements Temperature: Humidity: Altitude: Mechanical Dimensions W, D, H: Weight: Shipping Size L, W, H Shipping weight: Compliances Safety: EN60950 600mm (23.6), 19 standard mounting rails, 600mm (23.6), 2000mm (78 ) 40U of rack space. 180kg (approx) 2100mm, 720mm, 830mm 195kg (approx) -10C to +70C (max. power de-rated above 50C) 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level. 56x positions for 18mm wide DIN rail mount circuit breakers. May be arranged in many configurations of loads and batteries. Fuse options also available. (options) Single battery LVD. Up to 2x LVDs with independent control may be fitted on battery or load side. (option) 1200A SM31 (standard) SM32 TCP/IP enabled for web based viewing & configuration. (option) system terminal access. monitoring. (bloc voltage & string current)

Supervisory Module Mounting: Door mounted for improved Battery Condition Monitoring: Optional full battery monobloc

Part Numbers: Actual part numbers will vary with congifuration.


22 | ENATEL | 2010 PRODUCT CATALOGUE

Contact us for further details on a solution that suits your requirements.

WALL MOUNT SYSTEM 4.0kW 48V DC / 2.1kW 24V DC


AC Input: Single phase with surge protection and input 32A MCB (refer to rectifier brochure for full details) 45-66Hz >0.99 (full load) Single phase. Direct MCB termination for L. 10mm N, E tunnel

Frequency Range: Power Factor: Termination: terminals. DC Output Nominal Voltages: Max Rated System Output Power: Polarity: DC Distribution: Load: Battery:

-48V version. 4000W @ -48V DC, 83A max. Positive earth. 1x RM3048 3000W rectifier or 2x RM2048 2000W rectifiers.

+24V version. 2140W @ +24V DC, 80A max. Negative Earth. 1x RM2324 2140W rectifier or 2x RM1848/24 900W rectifiers.

Max 8x 18mm MCB load circuit breakers. Max 2x 18mm MCB load circuit breakers. Electronic fuse fail. (Auxiliaries optional) Live: Direct MCB connections. Common: 16mm tunnel terminals. Common: 35mm tunnel terminals. 80A battery LVD fitted as standard on -48V and 24V systems.

Breaker Fail Detection: DC Terminals: Load: Battery:

Low Voltage Disconnect:

Weight: Dimensions (L, H,W): Shipping Dimensions (L, H,W):

Approx. 10.5Kg 620mm x 375mm x 80mm 730mm x 470mm x 200mm

48 4.0 24 2.1

nominal output voltage.

maximum output power.

kW

nominal output voltage.

maximum output power.

kW

Monitoring and Control:

Various monitoring options via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. Options include extension remote I/O PCBs that give an extra 6x digital inputs, 6x analogue inputs and 8x voltage-free relay outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSW-4204810-000: PSW-4204820-000: PSW-3104810-000: PSW-3104820-000: PSW-2102410-000: PSW-2102420-000: PSW-2202410-000: PSW-2202420-000:

Actual part numbers will vary with congifuration. 48V, 2x 2000W rectifiers, SM31 supervisory module. 48V, 2x 2000W rectifiers, SM32 supervisory module. (Remote communication via SNMP) 48V, 1x 3000W rectifier, SM31 supervisory module. 48V, 1x 3000W rectifier, SM32 supervisory module. (Remote communication via SNMP) 24V, 1x 2140W rectifier, SM31 supervisory module. 24V, 1x 2140W rectifier, SM32 supervisory module. (Remote communications via SNMP) 24V, 2x 900W rectifiers, SM31 supervisory module. 24V, 2x 900W rectifiers, SM32 supervisory module. (Remote communication via SNMP)
ENATEL | 2010 PRODUCT CATALOGUE | 23

MODULAR RECTIFIERS
- Force cooled. - Microprocessor controlled. - Power factor corrected. - Thermally protected. - Input/output voltage and current protected. - Serial alarm and control interface. These rectiers are designed for integration into systems that require intelligent features and remote control. With efciencies in excess of 92% and power factors of greater than 0.98 these rectiers will save operating costs, and reduce heat dissipation. Suitable for powering a wide range of telecommunications and data networking applications including wireless, access networks and central ofce switching environments. If you are looking for modular, plug and play rectiers with some of the highest power densities in the market you have come to the right place.

24 | ENATEL | 2010 PRODUCT CATALOGUE

RM3048 3.0kW 48V DC MODULAR RECTIFIER


AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Inrush: Auto shutdown, auto restart when correct voltage restored. <2x maximum input current. 230V 90-300V (reduced power below 175V) 45-65 Hz >0.99 >92% (>45% output power) HRC fuses in phase and neutral. 19A

DC Output Output Ratings: Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Line: Load: Constant power output from 50V to 58V 48V 58V 43-60V 60A 0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop. Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <1mV rms unweighted <1mV rms psophometric <5mV rms unweighted <50mV peak to peak 4000V DC 3500V DC (VDR to chassis removed) 2100V DC

Regulation:

Hold-up Time: Start-up Time: Protection: Current Limit: Over Temperature: Polarity Reversal: Over voltage: Ripple <100Hz: Voice band 100Hz-5KHz: Wide band 5kHz-1MHz: Peak to Peak 0-20MHz: Input to Output: Input to Chassis: Output to Chassis:

48 3.0 60.0

nominal output voltage.

nominal output power.

kW

maximum output current.

Noise: (under nominal conditions)

Isolation:

Environmental Requirements Ambient Temperature: Nominal: Range: 25+/-5C -10C to +70C (maximum output power is derated above +50C) -20C to +70C 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Storage Temperature: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Other:

41mm, 220mm, 305mm overall. 2.7kg 52mm, 230mm, 340mm 2.85kg Forced cooled, using dual temperature controlled high reliability fans.

EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 CE & RoHS compliant.


ENATEL | 2010 PRODUCT CATALOGUE | 25

RM3048/24 3.0kW 48V DC / 1.7kW 24V DC MODULAR RECTIFIER

48 3.0 24 1.7 60.0


nominal output voltage.

AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Inrush: Auto shutdown, auto restart when correct voltage restored. <2x maximum input current. 48V Constant power output from 50V to 60V 48V 58V 43-60V 60A 0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop. Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <1mV rms unweighted <1mV rms psophometric <5mV rms unweighted <50mV peak to peak 4000V DC 3500V DC (VDR to chassis removed) 2100V DC 24V Current limited to 60A 24V 29V 21-30V 60A 230V 90-300V (reduced power below 175V) 45-65 Hz >0.99 >92% (>45% output power) HRC fuses in phase and neutral. 19A

nominal output power.

kW

DC Output - Software Switchable Output Ratings: Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Line: Load:

Regulation:

nominal output voltage.

Hold-up Time: Start-up Time: Protection: Current Limit: Over Temperature: Polarity Reversal: Over voltage: Ripple <100Hz: Voice band 100Hz-5KHz: Wide band 5kHz-1MHz: Peak to Peak 0-20MHz: Input to Output: Input to Chassis: Output to Chassis:

nominal output power.

kW

Noise: (under nominal conditions)

Isolation:

maximum output current.

Environmental Requirements Ambient Temperature: Nominal: Range: 25+/-5C -10C to +70C (maximum output power is derated above +50C) -20C to +70C 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Storage Temperature: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Other:
26 | ENATEL | 2010 PRODUCT CATALOGUE

41mm, 220mm, 305mm overall. 2.7kg 52mm, 230mm, 340mm 2.85kg Forced cooled, using dual temperature controlled high reliability fans.

EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 CE & RoHS compliant.

RM3060/48 3.0kW 60/48V DC MODULAR RECTIFIER


AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Inrush: Auto shutdown, auto restart when correct voltage restored. <2x maximum input current. 60V Constant power output from 60V to 74V 60V 68V 52-74V 50A 48V 48V 58V 43-60V 50A 230V 90-300V (reduced power below 175V) 45-65 Hz >0.99 >92% (>45% output power) HRC fuses in phase and neutral. 19A

DC Output - Software Switchable Output Ratings: Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current:

Current limited to 50A

Regulation: Line: Load: 0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop Start up delay 1 second. (varies with AC supply voltage)

Hold-up Time: Start-up Time: Protection: Current Limit: Over Temperature: Polarity Reversal: Over voltage: Ripple <100Hz: Voice band 100Hz-5KHz: Wide band 5kHz-1MHz: Peak to Peak 0-20MHz: Input to Output: Input to Chassis: Output to Chassis:

60/48 3.0 50.0

nominal output voltage.

nominal output power.

kW

maximum output current.

Walk-in delay 6 seconds at full output. (varies with DC output voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <1mV rms unweighted <1mV rms psophometric <5mV rms unweighted <50mV peak to peak 4000V DC 3500V DC (VDR to chassis removed) 2100V DC

Noise: (under nominal conditions)

Isolation:

Environmental Requirements Ambient Temperature: Nominal: Range: 25+/-5C -20C to +70C (maximum output power is derated above +50C) -20C to +70C 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Storage Temperature: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Other:

41mm, 220mm, 305mm overall. 2.8kg 52mm, 230mm, 340mm 2.95kg Forced cooled, using dual temperature controlled high reliability fans.

EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 CE & RoHS compliant.


ENATEL | 2010 PRODUCT CATALOGUE | 27

RM2324 2.3kW 24V DC MODULAR RECTIFIER

24 2.3 80.0
nominal output voltage.

AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Inrush: Auto shutdown, auto restart when correct voltage restored. <2x maximum input current. 230V 90-300V (reduced power below 150V) 45-65 Hz >0.99 >91% (>45% output power) HRC fuses in phase and neutral. 19A

nominal output power.

kW

DC Output Output Ratings: Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Line: 0.1% Load: 0.5% (no load to full load) >15ms for 20% output voltage drop. Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 7 seconds at full output. (varies with DC output voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <1mV rms unweighted <1mV rms psophometric <5mV rms unweighted <50mV peak to peak 4000V DC 3500V DC (VDR to chassis removed) 2100V DC Current limited to 80A 24V 29V 21-30V 80A

Regulation:

maximum output current.

Hold-up Time: Start-up Time: Protection: Current Limit: Over Temperature: Polarity Reversal: Over voltage: Ripple <100Hz: Voice band 100Hz-5KHz: Wide band 5kHz-1MHz: Peak to Peak 0-20MHz: Input to Output: Input to Chassis: Output to Chassis:

Noise: (under nominal conditions)

Isolation:

Environmental Requirements Ambient Temperature: Nominal: Range: 25+/-5C -10C to +70C (maximum output power is derated above +50C) -20C to +70C 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Storage Temperature: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Other:
28 | ENATEL | 2010 PRODUCT CATALOGUE

41mm, 220mm, 305mm overall. 2.7kg 52mm, 230mm, 340mm 2.75kg Forced cooled, using dual temperature controlled high reliability fans.

EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 CE & RoHS compliant.

RM2048XP 2.0KW 48V DC MODULAR RECTIFIER


AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Total Harmonic Distortion (THD): Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Inrush: Auto shutdown, auto restart when correct voltage restored. <12A rms 230V 90-300V (reduced power below 175V) 45-65 Hz >0.99 >92% (>50% output power) <5% (>30% output power) HRC fuses in phase and neutral. 12A

DC Output Output Ratings: Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Line: Load: Constant power output from 48V to 58V 48V 58V 43-60V 41.7A 0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop. Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <1mV rms unweighted <1mV rms psophometric <5mV rms unweighted <100mV peak to peak 4000V DC 3500V DC (VDR to chassis removed) 2100V DC

Regulation:

Hold-up Time: Start-up Time: Protection: Current Limit: Over Temperature: Polarity Reversal: Over voltage: Ripple <100Hz: Voice band 100Hz-5KHz: Wide band 5kHz-1MHz:

48 2.0 41.7

nominal output voltage.

nominal output power.

kW

maximum output current.

Noise: (under nominal conditions)

Peak to Peak 0-20MHz: Isolation: Input to Output: Input to Chassis: Output to Chassis:

Environmental Requirements Ambient Temperature: Nominal: Range: 25+/-5C -10C to +70C (maximum output power is derated above +50C) -20C to +70C 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Storage Temperature: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Other:

111.5mm , 44mm (1U), 282mm overall (rack depth 260mm) 1.5kg 120mm, 52mm, 325mm 1.6kg Forced cooled.

EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 CE & RoHS compliant.


ENATEL | 2010 PRODUCT CATALOGUE | 29

RM2048/24 2.0kW 48V DC / 1.0kW 24V DC MODULAR RECTIFIER

48 2.0 24 1.0 41.7


nominal output voltage.

AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Inrush: Auto shutdown, auto restart when correct voltage restored. <2x maximum input current. 48V Constant power output from 54V to 60V 48V 58V 43-60V 41.7A 0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop. Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <1mV rms unweighted <1mV rms psophometric <5mV rms unweighted <50mV peak to peak 4000V DC 3500V DC (VDR to chassis removed) 2100V DC 24V Current limited to 41.7A 24V 29V 21-30V 41.7A 230V 90-300V (reduced power below 175V) 45-65 Hz >0.99 >91% (>50% output power) HRC fuses in phase and neutral. 13A

nominal output power.

kW

DC Output - Software Switchable Output Ratings: Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Line: Load:

Regulation:

nominal output voltage.

Hold-up Time: Start-up Time: Protection: Current Limit: Over Temperature: Polarity Reversal: Over voltage: Ripple <100Hz: Voice band 100Hz-5KHz: Wide band 5kHz-1MHz: Peak to Peak 0-20MHz: Input to Output: Input to Chassis: Output to Chassis:

nominal output power.

kW

Noise: (under nominal conditions)

Isolation:

maximum output current.

Environmental Requirements Ambient Temperature: Nominal: Range: 25+/-5C -10C to +70C (maximum output power is derated above +50C) -20C to +70C 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Storage Temperature: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Other:
30 | ENATEL | 2010 PRODUCT CATALOGUE

111.5mm , 44mm (1U), 282mm overall (rack depth 260mm) 1.5kg 120mm, 52mm, 325mm 1.6kg Forced cooled.

EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 CE & RoHS compliant.

RM1860/48 1.8kW 60/48V DC MODULAR RECTIFIER


AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Inrush: Auto shutdown, auto restart when correct voltage restored. <2x maximum input current. 60V Constant power output from 60V to 74V 60V 68V 52-74V 30A 0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop Start up delay 1 second. (varies with AC supply voltage) 48V 48V 54V 43-60V 30A 230V 90-300V (reduced power below 175V) 45-65 Hz >0.99 >91% (>50% output power) HRC fuses in phase and neutral. 11A

DC Output - Software Switchable Output Ratings: Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Regulation: Line: Load:

Current limited to 30A

Hold-up Time: Start-up Time: Protection: Current Limit: Over Temperature: Polarity Reversal: Over voltage: Ripple <100Hz: Voice band 100Hz-5KHz: Wide band 5kHz-1MHz: Peak to Peak 0-20MHz: Input to Output: Input to Chassis: Output to Chassis:

60/48 1.8 30.0

nominal output voltage.

nominal output power.

kW

maximum output current.

Walk-in delay 6 seconds at full output. (varies with DC output voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <1mV rms unweighted <1mV rms psophometric <5mV rms unweighted <50mV peak to peak 4000V DC 3500V DC (VDR to chassis removed) 2100V DC

Noise: (under nominal conditions)

Isolation:

Environmental Requirements Ambient Temperature: Nominal: Range: 25+/-5C -10C to +70C (maximum output power is derated above +50C) -20C to +70C 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Storage Temperature: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Other:

111.5mm , 44mm (1U), 282mm overall (rack depth 260mm) 1.4kg 120mm, 52mm, 325mm 1.5kg Forced cooled.

EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 CE & RoHS compliant.


ENATEL | 2010 PRODUCT CATALOGUE | 31

RM1048 1.0kW 48V DC MODULAR RECTIFIER

48 1.0 21.0
nominal output voltage.

AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Protection: Input Voltage: Input Inrush: Auto shutdown, auto restart when correct voltage restored. <2x maximum input current. 7A 230V 90-300V (reduced power below 175V) 45-65 Hz >0.99 >90% (>50% output power) HRC fuses in phase and neutral.

Maximum Input Current: DC Output Output Ratings: Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Line: Load:

nominal output power.

kW

Constant power output from 48V to 58V 48V 58V 43-60V 21A 0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop. Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <1mV rms unweighted <1mV rms psophometric <5mV rms unweighted <50mV peak to peak 4000V DC 3500V DC (VDR to chassis removed) 2100V DC

Regulation:

maximum output current.

Hold-up Time: Start-up Time: Protection: Current Limit: Over Temperature: Polarity Reversal: Over voltage: Ripple <100Hz: Voice band 100Hz-5KHz: Wide band 5kHz-1MHz: Peak to Peak 0-20MHz: Input to Output: Input to Chassis: Output to Chassis:

Noise: (under nominal conditions)

Isolation:

Environmental Requirements Ambient Temperature: Nominal: Range: 25+/-5C -10C to +75C (maximum output power is derated above +50C) -20C to +75C 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Storage Temperature: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Other:
32 | ENATEL | 2010 PRODUCT CATALOGUE

111.5mm , 44mm (1U), 282mm overall (rack depth 260mm) 1.4kg 120mm, 52mm, 325mm 1.5kg Forced cooled

EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 CE & RoHS compliant.

RM848 800W 48V DC MODULAR RECTIFIER


AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Inrush: Auto shutdown, auto restart when correct voltage restored. <2x maximum input current. 230V 90-300V (reduced power below 175V) 45-65 Hz >0.99 >92% (>50% output power) HRC fuses in phase and neutral. 5.5A

DC Output Output Ratings: Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Line: Load: Constant power output from 54V to 58V 48V 58V 43-60V 16.6A 0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop. Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <1mV rms unweighted <2mV rms psophometric <5mV rms unweighted <50mV peak to peak 4000V DC 3500V DC (VDR to chassis removed) 2100V DC

Regulation:

Hold-up Time: Start-up Time: Protection: Current Limit: Over Temperature: Polarity Reversal: Over voltage: Ripple <100Hz: Voice band 100Hz-5KHz: Wide band 5kHz-1MHz: Peak to Peak 0-20MHz: Input to Output: Input to Chassis: Output to Chassis:

48 800 16.6

nominal output voltage.

nominal output power.

maximum output current.

Noise: (under nominal conditions)

Isolation:

Environmental Requirements Ambient Temperature: Nominal: Range: 25+/-5C -20C to +70C (maximum output power is derated above +50C) -20C to +70C 0-98% RH (non-condensing) <3000m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Storage Temperature: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Other:

55mm , 44mm (1U), 235mm overall (rack depth 260mm) 800g 100mm, 80mm, 300mm 1.0kg Forced cooled.

EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 CE & RoHS compliant.


ENATEL | 2010 PRODUCT CATALOGUE | 33

FLAT MOUNT RECTIFIERS


- Forced cooled. - Thermally protected. - Power factor corrected. - Input/output voltage and current protected. With power ratings of 300W up to 1.4kW and output voltages of 12, 24 and 48V DC these rectiers offer temperature compensation, and auto oat/boost switching as standard. They have options available for internal low voltage disconnect (LVD) and an alarm card, with relay outputs. These rectiers can provide the powering solution for most small and medium telecommunications, and data networking power applications. Efcient and reliable, these rack mounting rectiers allow for easy paralleling of modules to provide redundancy or higher power outputs. Internal options include low voltage disconnect (LVD) and an alarm card with relay outputs. The unique design allows for mounting two rectiers in a 1U x 19 rack space. Custom congurations can be specied and additional features can be added. Easy to install and compact, these robust, reliable rectiers are forced cooled by a speed controlled and monitored fan. - Temperature compensation. - Automatic oat/boost charge cycle. - Alarm and control interface including active load sharing. voltage disconnect. card with relay outputs. - Optional built-in low - Optional internal alarm Flat mount rectiers have been developed to allow provision of simple, and low cost solutions where only a limited amount of rack space is available. With all input and output connections available on the front panel of the rectier units they can be easily integrated in simple DC systems solutions.

34 | ENATEL | 2010 PRODUCT CATALOGUE

RF SERIES FLAT MOUNT RECTIFIERS


AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Maximum Input Current: Input Fuses: Protection: Input Voltage: Input Rush: DC Output Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Regulation: Line: Load: Hold-up Time: Start-up Time: Protection: Current Limit: Over Temp: Polarity Reversal: Over Voltage: Noise: (under nominal conditions) Ripple <100Hz: Voice Band 100Hz to 5KHz: Wide Band 5kHz to 1 MHz: Peak to Peak 0 to 20MHz: Isolation: Input to Output: Input to Chassis: Output to Chassis: Environmental Requirements Nominal Ambient Temperature: Range: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions, W, H, D: Shipping Weight: Cooling: Connections: Mains: Output to Load: Temperature Sensor: Monitor Connection: Internal Alarm Card: Standard Features Temperature Compensation: Auto Float/Boost: Alarm and Indicator Controls: Options Low Voltage Disconnect: Voltage Adjustment Range: Maximum Load Current: Internal Alarm Card: Maintenance LED Indicators: Internal Adjustments: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Ordering Information RFxxxx-10: RFxxxx-11: RFxxxx-20: RFxxxx-21:

RF1448 RF1124 220/240V, 50/60Hz 220/240V, 50/60Hz 180-275V AC 180-275V AC (full power output), (full power output), 150-180V AC 150-180V AC (reduced power output) (reduced power output) 45-66Hz >0.93 (full load) RF1448 RF1124 90% 92% 8.5A 8.5A HRC fuses in phase & neutral.

RF748U 110-220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output) RF748U 89% 8.5A

RF624U 110-220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output) RF624U 87% 8.5A

RF512U 110-220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output) RF512U 85% 8.5A

RF348U 110-220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output) RF348U 85% 8.5A

Automatic shutdown, restarts automatically when correct voltage restored. <2x maximum input current. RF1448 48V 58V 45-60V 25A RF1124 24V 29V 22-30V 40A RF748U 48V 58V 45-60V 12A RF624U 24V 29V 22-30V 22A RF512U 12V 14.5V 11.5-15V 40A RF348U 48V 58V 45-60V 6A

0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop. Walk-in delay 2 seconds. (depends on AC input voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. RF1124 RF748U RF1448 <10mV rms unweighted. <5mV rms unweighted. <10mV rms unweighted. <2mV rms psophometric. <1mV rms psophometric. <2mV rms psophometric. <10mV rms unweighted. <5mV rms unweighted. <10mV rms unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. 3000V AC 2500V AC (VDR to chassis removed) 1500V AC 25+/-5C -10 to +50C 5-95% RH (non-condensing.) <2500m de-rate maximum ambient temperature by +4 per 1000m above sea level. 227mm, 44mm (1U), 270mm, (293mm over handle) 1.5kg 377mm, 235mm, 122mm 2.4kg Forced cooled. IEC 320 universal connection. 4 way lumberg macromodule. 2 way lumberg macromodule. RJ45 Mini combicon. Output voltage slope adjustable 0.1 to 0.2%/C (standard) Rectifier enters boost mode at power up. When battery current reduces to float threshold limit (adjustable from 0.1A to 40% MRC), unit reverts to float voltage setting. When in boost but out of current limit, rectifier will automatically switch back to float after approximately four hours. If battery current exceeds the float threshold limit when the rectifier is in float mode it will automatically switch to boost mode. Positive V out, Load share signal (in/out), External shutdown, Open collector off normal alarm, (OSVD, over temp., current limit, fan fail), LVD synchronisation signal (in/out), Temperature compensation input signal, Open collector rectifier fail (via 4k7 resistor), Open collector mains fail, Negative V out. RF1448 RF1124 RF748U RF624U RF512U RF348U 38-48V 19-24V 38-48V 19-24V 9.5-12V 38-48V 25A 40A 12A 22A 40A 6A 4x N.O or N.C (selectable) relay contacts with single common for rectifier fail, off normal, float low, float high. 1x VF changeover relay contact for mains fail. Relay contacts rated at 100V DC 1A. Connections via mini combicon connector accepts 1.5mm dia wire. Green - Mains on. (primary converter operating) Green - Temperature probe connected and within normal limits. Red - Rectifier failed. Green - Rectifier in float mode. Yellow - Rectifier in boost mode. Yellow - Rectifier in current limit. Red - Rectifier off normal. (over temp., OVSD, low output volts) Float voltage. Boost voltage. Over voltage shut down. Current limit. Temperature compensation slope. Auto boost to float threshold limit. Load disconnect voltage. (if fitted) Load disconnect hysteresis voltage. (if fitted) EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 Standard Standard Standard Standard with with with with temperature temperature temperature temperature compensation, compensation, compensation, compensation, auto auto auto auto float float float float boost, boost, boost, boost, alarm alarm alarm alarm and and and and control control control control I/F. I/F, low volts disconnect. I/F, alarm card. I/F, low volts disconnect, alarm card.

RF624U <5mV rms unweighted. <1mV rms psophometric. <5mV rms unweighted. <50mV p-p unweighted.

RF512U RF348U <5mV rms unweighted. <5mV rms unweighted. <0.5mV rms psophometric. <0.5mV rms psophometric. <2.5mV rms unweighted. <2.5mV rms unweighted. <50mV p-p unweighted. <50mV p-p unweighted.

ENATEL | 2010 PRODUCT CATALOGUE | 35

WALL MOUNT RECTIFIERS


- Convection cooled. - Thermally protected. - Power factor corrected. - Input/output voltage and current protected. charge cycle. with active load sharing. - Automatic oat/boost - Alarm and control interface - Temperature compensation. - Output current indicator. - Optional built-in low voltage disconnect. card with relay outputs. Easy to install and compact, these robust, reliable rectiers are convection cooled and are available with temperature compensation, and options for internal low voltage disconnect (LVD) and alarm card with relay outputs. They can be used as standalone power sources or can be operated in parallel to provide redundancy or higher output ratings. Choose from a range of internal options including load disconnect, current indicators, alarm and control interface and auto oat/boost. Custom congurations can be specied and additional features can be added. - Optional internal alarm Easily paralleled to provide redundancy, or higher power outputs these rectiers are simple to install and can be bolted directly to a wall or at panel space. Providing outputs of 12, 24 and 48V from 300W up to 700W output these rectiers offer temperature compensation, and auto oat/boost switching as standard. They have options available for internal low voltage disconnect (LVD) and an alarm card, with relay outputs. These highly efcient rectiers offer a range of output voltages and power levels. The Enatel RW series of wall mount rectiers have been developed to provide fully integrated power solutions for small telecommunications, and data networking applications.

36 | ENATEL | 2010 PRODUCT CATALOGUE

RW SERIES WALL MOUNT RECTIFIERS


AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Maximum Input Current: Input Fuses: Protection: Input Voltage: Input Rush: DC Output Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Regulation: Line: Load: Hold-up Time: Start-up Time: Protection: Current Limit: Over Temp: Polarity Reversal: Over Voltage: Noise: (under nominal conditions) Ripple <100Hz: Voice Band 100Hz to 5KHz: Wide Band 5kHz to 1 MHz: Peak to Peak 0 to 20MHz: Isolation: Input to Output: Input to Chassis: Output to Chassis: Environmental Requirements Nominal Ambient Temperature: Range: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions, W, H, D: Shipping Weight: Cooling: Connections: Mains: Output to Load: Output to Batteries: Temperature Sensor: Monitor Connection: Internal Alarm Card: Standard Features Output Current Indicator: Temperature Compensation: Auto Float/Boost: Alarm and Indicator Controls: Options Low Voltage Disconnect: Voltage Adjustment Range: Maximum Load Current: Internal Alarm Card: Maintenance LED Indicators: Internal Adjustments: Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Ordering Information RWxxxx-10: RWxxxx-11: RWxxxx-20: RWxxxx-21:

110/220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output) 45-66Hz >0.99 (full load) RW748U RW624U RW512U 88% 87% 85% 8.5A 8.5A 8.5A HRC fuses in phase & neutral. Automatic shutdown, restarts automatically when correct voltage restored. <2x maximum input current. RW748U 48V 58V 45-60V 12A 700W RW624U 24V 29V 22-30V 22A 600W RW512U 12V 14.5V 11.5-15V 35A

RW348U 88% 8.5A

RW324U 87% 4A

RW312U 85% 4A

RW348U 48V 58V 45-60V 6A 300W

RW324U 24V 29V 22-30V 10A 300W

RW312U 12V 14.5V 11.5-15V 20A 300W

0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop. Walk-in delay 2 seconds (depends on AC input voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. RW748U RW624U RW512U RW348U <10mV rms unweighted. <5mV rms unweighted. <5mV rms unweighted. <10mV rms unweighted. <2mV rms psophometric. <1mV rms psophometric. <0.5mV rms psophometric. <2mV rms psophometric. <10mV rms unweighted. <5mV rms unweighted. <2.5mV rms unweighted. <10mV rms unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. <50mV p-p unweighted. 3000V AC. 2500V AC (VDR to chassis removed) 1500V AC 25+/-5C -10 to +50C 5-95% RH (non-condensing) <2500m de-rate maximum ambient temperature by +4 per 1000m above sea level. 311mm, 163mm, 62mm 1.5kg 377mm, 235mm, 122mm 2.4kg Convection cooled. IEC 320 universal connection. 4 way lumberg macromodule. 4 way lumberg macromodule. 2 way lumberg macromodule. RJ45. Mini combicon. Ten segment red LED dot display (standard) Output voltage slope adjustable 0.1 to 0.2%/C (standard) Rectifier enters boost mode at power up. When battery current reduces to float threshold limit (adjustable from 0.1A to 40% MRC), unit reverts to float voltage setting. When in boost but out of current limit, rectifier will automatically switch back to float after approximately four hours. If battery current exceeds the float threshold limit when the rectifier is in float mode it will automatically switch to boost mode. Positive V out, Load share signal (in/out), External shutdown, Open collector off normal alarm (OSVD, over temp. limit), LVD synchronisation signal (in/out) Temperature compensation input signal, Open collector rectifier fail (via 4k7 resistor), Open collector mains fail, Negative V out. RW748U RW624U RW512U RW348U RW324U RW312U 38-48V 19-24V 9.5-12V 38-48V 19-24V 9.5-12V 12A 22A 35A 6A 10A 20A 4x N.O or N.C (selectable) relay contacts with single common for rectifier fail, off normal, float low, float high. 1x VF changeover relay contact for mains fail. Relay contacts rated at 100V DC 1A. Connections via mini combicon connector accepts 1.5mm dia wire. Green - Mains on. (primary converter operating) Green - Temperature probe connected and within normal limits. Red - Rectifier failed. Green - Rectifier in float mode. Yellow - Rectifier in boost mode. Yellow - Rectifier in current limit. Red - Rectifier off normal. (over temp. OVSD, low output volts) Float voltage. Boost voltage. Over voltage shut down. Current limit. Temperature compensation slope. Auto boost to float threshold limit. Load disconnect voltage. (if fitted) Load disconnect hysteresis voltage. (if fitted) EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 Standard Standard Standard Standard with with with with temperature temperature temperature temperature compensation, compensation, compensation, compensation, auto auto auto auto float float float float boost, boost, boost, boost, alarm alarm alarm alarm and and and and control control control control I/F. I/F, low volts disconnect. I/F, alarm card. I/F, low volts disconnect, alarm card.

RW324U <5mV rms unweighted. <1mV rms psophometric. <5mV rms unweighted. <50mV p-p unweighted.

RW312U <5mV rms unweighted. <0.5mV rms psophometric. <2.5mV rms unweighted. <50mV p-p unweighted.

ENATEL | 2010 PRODUCT CATALOGUE | 37

DC-AC POWER SYSTEMS


- Integrated monitoring presents simplied systems management. with n+1 redundancy. revenue generating equipment. grade inverters. monitoring optional. less cost of maintenance. maintenance costs. For further information on Enatels range of inverter systems, contact us today. suit eachcustomers individual needs. One of the unique features offered by the Enatel system solution is the ability to integrate AC/DC rectiers, DC/DC converters and also DC/AC inverters into a system with a single controller, providing remote monitoring capabilities from a single point. The inverter modules are available in 1.5kVA with either 110/120 or 220/230V AC output, and are scalable up to 15kVA. The inverter system solutions also include 12kVA static switch and maintenance bypass modules. - Hot-swap/hot-plug modules - Small size means more room for - Fully featured telecom - TCP/IP and SNMP network - High reliability means - Full remote monitoring reduces - Easily customized and congured to Enatels ISM series inverter solutions offer a hot swappable modular inverter system for supplying critical AC loads in telecom, and data networking applications.

7U Inverter System

Supervisory Module

SM32

IM10230-48

IM10230-48

IM10230-48

IM10230-48

IM10230-48

IM10230-48

IM10230-48

IM10230-48

IM10230-48

38 | ENATEL | 2010 PRODUCT CATALOGUE

DC-AC INVERTERS
Efcient and reliable, these modular rack mount inverters allow for easy paralleling of modules to provide redundancy or higher power outputs. Designed for use in modern telecommunications networks these inverters offer unrivalled power densities. The unique design allows for mounting nine inverters in a 5U x 19 rack space or two inverters in a 1U x 19 rack space. Plug and Play installation allows quick and easy installation and system expansion. These robust, reliable inverters are forced cooled by two speed controlled and monitored high reliability fans. - Pure sine wave. - Hot swapable. - High efciency. - Smart fan speed control. - Wide operation temperature range. - DSP chip designed. - N+X redundancy system. - Lower audible noise. - High power density. - Enatel RCP bus. - 48V DC telecom system application. - CE & RoHS compliant.

ENATEL | 2010 PRODUCT CATALOGUE | 39

IM SERIES MODULAR INVERTERS


DC Input Operating Voltage Range: 40.5-58V DC

AC Output Nominal Output Voltage: Output Voltage Range: Output Voltage Tolerance: Output Voltage Frequency: Output Frequency Tolerance: Total Harmonic Distortion: Turn On Delay: Crest Factor: Efficiency: 110/230V AC (refer to part number table below for model numbers) 110/115/120V AC or 208/220/230/240V AC +/- 2% 50/60Hz selectable. +/- 0.5% <3% on linear loads. <5% for non linear loads. <3 seconds. 3:1 (nominal power) 90%

Output Power Nominal Value: Overload (5 Seconds): Permanent Overload: Admissible Load Power Factor: Isolation: Input/Output: Output/Earth: Input Earth:

(refer to part number table below for model numbers) 1000VA, 800W/ 1500VA, 1200W 2000VA 10% 0 inductive to 0 capacitive (100% load)

2500V AC 2500V AC 1500V AC -40C to +50C, derated to +70C <55dBa @ 1m 3x LEDs, fail, off normal, power on. Enatel SBI interface to SM3X supervisory module.

Operating Temperature Range: Acoustic Noise: Display: Serial Comms:

Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: 215mm, 43.8mm, 270mm overall. 2.5kg 52mm, 230mm, 340mm 2.65kg Forced cooled.

Compliances Immunity: Emissions: Safety: Other: CISPR24 CISPR22 Class B IEC60950 CE & RoHS compliant.

Part Numbers IM10230-48: IM10110-48: IM15230-48: IM15110-48:


40 | ENATEL | 2010 PRODUCT CATALOGUE

1U, 48V DC input, 230V AC output, 1.0kVA 800W 1U, 48V DC input, 120V AC output, 1.0kVA 800W 1U, 48V DC input, 230V AC output, 1.5kVA 1200W 1U, 48V DC input, 120V AC output, 1.5kVA 1200W

SBM SERIES STATIC BYPASS MODULE


The Enatel SBM series static bypass module increases system reliability by automatically switching between the inverter output and the utility supply. The SBM12000 can be programmed so that the system operates in a standby backup mode were the utility is the normal source of supply or alternatively the system can be the normal source of supply with automatic switchover to the utility in the event of system failure. - Universal input range. - Hot-swap replacement in shelf. - Back feed protection. - Redundant fan design. - Redundant power supply design. - Fast transfer time, typically
Input AC Voltage Range: 110/115/120V AC: 208/220/240V AC: From 89 to 138V AC. 176 to 276V AC.

less than cycle. range -20 to +70C.

- Wide operation temperature - Lower audible noise <55dBA. - Emergency power off function embedded. - No-cross connect. - Optional maintenance bypass
220 to 240V AC for 208V AC systems. 233 to 252V AC for 220V AC systems. 244 to 264V AC for 230V AC systems. 254 to 276V AC for 240V AC systems. 117 to127V AC for 110V AC systems. 122 to 132V AC for 115V AC systems. 127 to 138V AC for 120V AC systems.

Over Voltage Threshold: Adjustable Using Controller:

switch function with interlock. transfer side by setting in controller module.

- Operation priority setup of

Under Voltage Threshold: Adjustable Using Controller:

Redundant Power Supply Design:

176 to 198V AC for 208V AC systems. 176 to 209V AC for 220V AC systems. 185 to 218V AC for 230V AC systems. 193 to 228V AC for 240V AC systems. 89 to 105V AC for 110V AC systems. 93 to 110V AC for 115V AC systems. 100 to 114V AC for 120V AC systems. Startup power-on by priority source or alternative.

Output Waveform: Nominal Output Voltage: Permissible Frequency Area: Transfer Time: Rated Current: Operation Methods: Sinusoidal. Same as mains AC or the output of inverter modules. Max. 2.5% (Synchronize area of inverter). 1.5Hz for 60Hz inverter. 1.25Hz for 50Hz inverter. Typical cycle. 50A (All voltage settings). Inverter priority or utility priority (Programmable).

Part Number: SBM12000: 50A/12kVA static bypass module.


ENATEL | 2010 PRODUCT CATALOGUE | 41

DC-DC CONVERTERS
- Force cooled. - Thermally protected. - Input/output voltage and current protected. These units offer the same high levels of conversion efciency as other Enatel power products, and will provide the same benets to the customer of reduced operating costs and lower levels of heat dissipation. The converters include a relay contact to indicate converter failure, and have a load share input that ensures that all units connected in parallel carry an equal share of the load. - Wide input voltage range. - Serial alarm and control interface. - Microprocessor controlled. These converters offer plug and play operation, and can be easily paralleled to provide higher power outputs.

42 | ENATEL | 2010 PRODUCT CATALOGUE

CM SERIES 1.7kW MODULAR DC-DC CONVERTERS


DC Input Nominal Input Voltage: Input Voltage Range: Input Protection: Fuses: Input Voltage: Fuse in the positive input with crowbar diode. Converter shuts down when input voltage is out of range, Automatically restarts when correct voltage is restored. CM1760-48 60V 57-65V 27A 1700W 91% 0.1% 0.5% (no load to full load) Walk-in delay 2-8 seconds depending on load. Adjustable to 50-100% of maximum rated current. Auto current turndown, backup shutdown protection. Output fuse in positive with crowbar diode. Adjustable limit. <1mV rms unweighted <1mV rms psophometric <5mV rms unweighted <50mV peak to peak 4230V DC 2115V DC (VDR to chassis removed) 2115V DC CM1748-60 48V 46-52V 33A 1700W 91% CM1748-48 48V 46-52V 33A 1700W 91% CM1760-48 48V 40-60V CM1748-60 60V 52-74V CM1748-48 48V 40-60V

DC Output Nominal Output Voltage: Output Voltage Range: Maximum Output Current: Maximum Output Power: Efficiency: Regulation: Line: Load:

Start-up Time: Protection: Current Limit: Over Temperature: Polarity Reversal: Over Voltage: Ripple <100Hz: Voice Band 100Hz-5KHz: Wide Band 5kHz-1MHz: Peak to Peak 0-20MHz: Input to Output: Input to Chassis: Output to Chassis:

Noise: (under nominal conditions)

Isolation:

Environmental Requirements Ambient Temperature: Nominal: Range: +25 +/- 5C -10 to +70C (maximum output power is derated above +50C) -20 to +70C 5-95% RH (non condensing) <2500m, De-rate maximum ambient temperature by +4C per 1000m above sea level.

Storage Temperature: Humidity: Altitude: Mechanical Dimensions W, H, D: Weight: Shipping Dimensions W, H, D: Shipping Weight: Cooling: Compliances Safety: Electostatic Discharge: Radiated Radio Frequency:

111.5mm, 44mm (1U), 282 overall (rack depth 260mm) 1.1kg 170mm, 52mm, 325mm 1.6kg Forced cooled.

EN60950 CISPR24 CISPR22

Additional Accesories ACM-4T: Part Numbers CM1760-48: CM1748-60: CM1748-48: 1.7kW 48 to 60V DC modular DC-DC converter. 1.7kW 60 to 48V DC modular DC-DC converter. 1.7kW 48 to 48V DC modular DC-DC converter.
ENATEL | 2010 PRODUCT CATALOGUE | 43

1U 4 position DC-DC converter shelf, no cables.

CM SERIES 500W to 1.0kW MODULAR DC-DC CONVERTERS


DC Input Nominal Input Voltage: Input Voltage Range: Input Protection: Fuses: Input Voltage: CM1048-24 CM1024-48 CM648-24 24V 48V 24V 20-30V 40-60V 20-30V CM624-48 48V 40-60V CM612-48 48V 40-60

Fuse in the positive input with crowbar diode. Converter shuts down when input voltage is out of range, Automatically restarts when correct voltage is restored. CM612-48 12V 11-14V 40A 560W 89%

DC Output CM1048-24 CM1024-48 CM648-24 CM624-48 Nominal Output Voltage: 48V 24V 48V 24V Output Voltage Range: 46-52V 22-26V 46-52V 22-26V Maximum Output Current: 21.6A 43A 13.5A 25A Maximum Output Power: 1040W 1040W 650W 650W 91% 91% Efficiency: 91% 91% Regulation: 0.1% Line: Load: 0.5% (no load to full load) Start-up Time: Walk-in delay 2-8 seconds depending on load and output Protection: Adjustable to 50-100% of maximum rated current. Current Limit: Over Temperature: Auto current turndown, backup shutdown protection. Polarity Reversal: Output fuse in positive with crowbar diode. Over Voltage: Adjustable limit. Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted Voice Band 100Hz-5KHz: <1mV rms psophometric Wide Band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <50mV peak to peak Isolation: 4230V DC Input to Output: 2115V DC (VDR to chassis removed) Input to Chassis: Output to Chassis: 2115V DC Environmental Requirements Ambient Temperature: Nominal: Range: Storage Temperature: Humidity: Altitude:

voltage.

+25 +/- 5C -10 to +70C (maximum output power is derated above +50C) -20 to +70C 5-95% RH (non condensing) <2500m, De-rate maximum ambient temperature by +4C per 1000m above sea level.

Mechanical Dimensions W, H, D: 111.5mm, 44mm (1U), 282 overall (rack depth 260mm) Weight: 1.1kg Shipping Dimensions W, H, D: 170mm, 52mm, 325mm Shipping Weight: 1.6kg Cooling: Forced cooled. Compliances Safety: Electostatic Discharge: Radiated Radio Frequency: Other: Additional Accesories ACM-4T: Part Numbers CM1048-24: CM1024-48: CM648-24: CM624-48: CM612-48:
44 | ENATEL | 2010 PRODUCT CATALOGUE

EN60950 CISPR24 CISPR22 CE & RoHS compliant

1U 4 position DC-DC converter shelf, no cables.

1.0kW 24 to 48V DC modular DC-DC converter. 1.0kW 48 to 24V DC modular DC-DC converter. 650W 24 to 48V DC modular DC-DC converter. 650W 48 to 24V DC modular DC-DC converter. 560W 48 to 12V DC modular DC-DC converter.

MONITORING
Enatel offer a range of supervisory modules and monitoring options, which have been designed to work with our power products. Allowing for easy integration into our complete DC power systems solutions for telecommunications and data networking applications. - Temperature compensation. - LVD control. - Setup from front panel. - Boost control and timer. - LCD display of parameters.

ENATEL | 2010 PRODUCT CATALOGUE | 45

SM36 SUPERVISORY MODULE

LVD WEB USB


dual lvd control. web based configurator. usb port for local connection.

Input Voltage: Current: Interface Display: Communications: Serial: Relay: TCP/IP: LVD: Indicators: 3x LEDs: Audible: Controls: Signal Inputs: Alarms: Alarm Contacts: Default Alarm Map: Relay 1: Relay 2: Relay 3: Relay 4 - 6: Logging Capacity: Periodic Log: Event Log: Battery Mid-point Monitoring: Physical Dimensions, W, H, D: Weight: Connections: Operating Temperature: Storage Temperature: Compliances Radiated Emissions: RF Susceptibility: Optional Accessories ACA-TC3C: ACA-TC7C: ASM-AC3P: ASM-ABM-24: ASM-SM36IO: Voltage Range: Current: Connection: Alarms: Signal Inputs: Operating Temperature: Storage Temperature: Part Numbers SM36-00: SM36-00-1U: SM36-10-1U: SM36-00-PM: SM36-10-PM:

16-75V DC <150mA maximum.

4 line x 16 character multi-lingual alpha numeric display. 1x USB port on front panel for local PC interface. 1x RS232 port, rear mounted for remote serial/modem communications. 6x alarm and control relays, five of which can be mapped for customized alarm settings. (extra available with I/O expansion board) Ethernet interface for communication using SNMP protocol and internal web based configurator. 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors) Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. 90dBA buzzer mappable to user defined conditions. 3x push buttons for parameter setting or viewing on front panel. 2x serial buses for rectifier control and interface to peripheral modules. 10x general purpose inputs. (6x for customer connection, 4x reserved for internal system connection.) 4x battery MCB sensors. (reserved for internal system connection.) 3x current shunt inputs. (reserved for internal system connection.) 1x DC voltage inputs. (reserved for internal system connection.) 6x alarm relays. 0.3A 100V volts free changeover contacts. Monitor fail. (non programmable.) Non-urgent. (programmable.) Urgent. (programmable.) Unassigned. Typically 16000 records. (dependant on number of parameters logged.) Typically 16000 records. (dependant on number of parameters logged.) 3x strings with individual string currents. (more available with shared string currents.) 111.5mm , 44mm (1U), 265mm overall (rack depth 244mm) 365g Relay outputs, mini combicon to accept 1.5mm csa wire. Serial communications to rectifier shelf & peripheral devices - RJ45. USB port - USB mini B. -25 to +55C -50 to +85C EN55022 EN55024 3m temperature sensor and cable. 7m temperature sensor and cable. 3 phase AC voltage and current monitor. Battery condition monitor, 24 blocks. (maximum 4x BCM cards) Standard I/O expansion board (maximum of 4 per supervisory module.) 15-75V DC <150mA maximum Connects via rectifier serial bus, 2x RJ45. Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Up to 6x digital inputs. Up to 6x analogue inputs. -25 to +55C -50 to +85C Standard 1U modular controller, 6x relays, 6x digital inputs. Standard 1U x 19 mounting version controller, 6x relays, 6x digital inputs. Standard 1U x 19 mounting version controller, 6x relays, 6x digital inputs; with standard I/O expansion board. Standard panel mount version controller, 6x relays, 6x digital inputs. Standard panel mount version controller, 6x relays, 6x digital inputs; with standard I/O expansion board.

46 | ENATEL | 2010 PRODUCT CATALOGUE

SM35 SUPERVISORY MODULE


Input Voltage: Current: Interface Display: Communications: Serial: Relay: LVD: Indicators: 3x LEDs Audible: Controls: Signal Inputs: Alarms: Alarm Contacts: Default Alarm Map: Relay 1: Relay 2: Relay 3: Relay 4 - 6: Logging Capacity: Periodic Log: Event Log: Battery Mid-point Monitoring: Physical Dimensions, W, H, D: Weight: Connections: Operating Temperature: Storage Temperature: Compliances Radiated Emissions: RF Susceptibility: Optional Accessories ACA-TC3C: ACA-TC7C: ASM-AC3P: ASM-ABM-24: ASM-SM3XIO: Voltage Range: Current: Connection: Alarms: Signal Inputs: Operating Temperature: Storage Temperature: Part Numbers SM35-00: SM35-00-1U: SM35-10-1U: SM35-00-PM: SM35-10-PM:

16-75V DC <150mA maximum.

4 line x 16 character multi-lingual alpha numeric display. 1x USB port on front panel for local PC interface. 6x alarm and control relays, five of which can be mapped for customized alarm settings. 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors) Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. 90dBA buzzer mappable to user defined conditions. 3x push buttons for parameter setting or viewing on front panel. 2x serial buses for rectifier control and interface to peripheral modules. 10x general purpose inputs. (6x for customer connection, 4x reserved for internal system connection.) 4x battery MCB sensors. (reserved for internal system connection.) 3x current shunt inputs. (reserved for internal system connection.) 1x DC voltage inputs. (reserved for internal system connection.) 6x alarm relays. 0.3A 100V volts free changeover contacts. Monitor fail. (non programmable.) Non-urgent. (programmable.) Urgent. (programmable.) Unassigned. Typically 16000 records. (dependant on number of parameters logged.) Typically 16000 records. (dependant on number of parameters logged.) 3x strings with individual string currents. (more available with shared string currents.)

serial control for up to 126 rectifiers/ converters plus peripheral devices.

usb port for local connection.

126 LCD USB


lcd display.

111.5mm , 44mm (1U), 265mm overall (rack depth 244mm) 325g Relay outputs, mini combicon to accept 1.5mm csa wire. Serial communications to rectifier shelf & peripheral devices - RJ45. USB port - USB mini B. -25 to +55C -50 to +85C

EN55022 EN55024

3m temperature sensor and cable. 7m temperature sensor and cable. 3 phase AC voltage and current monitor. Battery condition monitor, 24 blocks. (maximum 4x BCM cards.) Standard I/O expansion board (maximum of 4 per supervisory module.) 15-75V DC <150mA maximum Connects via rectifier serial bus, 2x RJ45. Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Up to 6x digital inputs. Up to 6x analogue inputs. -25 to +55C -50 to +85C

Standard 1U modular controller, 6x relays, 6x digital inputs. Standard 1U x 19 mounting version controller, 6x relays, 6x digital inputs. Standard 1U x 19 mounting version controller, 6x relays, 6x digital inputs; with standard I/O expansion board. Standard panel mount version controller, 6x relays, 6x digital inputs. Standard panel mount version controller, 6x relays, 6x digital inputs; with standard I/O expansion board.
ENATEL | 2010 PRODUCT CATALOGUE | 47

SM32 SUPERVISORY MODULE

LVD WEB USB


dual lvd control. web based configurator. usb port for local connection.

Input Voltage: Current: Interface Display: Communications: Serial: Relay: TCP/IP: LVD: Indicators: 3x LEDs Audible: Controls: Signal Inputs: Alarms: Alarm Contacts: Default Alarm Map: Logging Capacity: Periodic Log: Event Log: Physical Dimensions, W, H, D: Weight: Connections: Operating Temperature: Storage Temperature: Compliances Radiated Emissions: RF Susceptibility: Optional Accessories ACA-TC3C: ACA-TC7C: ASM-AC3P: ASM-ABM-24: ASM-SM3XIO: Voltage Range: Current: Connection: Alarms: Signal Inputs: Operating Temperature: Storage Temperature: Part Numbers SM32-00: SM32-10: SM32-00-1U: SM32-10-1U: SM32-00-PM: SM32-10-PM:

16-75V DC <150mA maximum.

4 line x 16 character multi-lingual alpha numeric display. 1x USB port on front panel for local PC interface. 1x RS232 port, rear mounted for remote serial/modem communications. 3x alarm and control relays, two of which can be mapped for customized alarm settings. (extra available with I/O expansion board) Ethernet interface for communication using SNMP protocol and internal web based configurator. 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors) Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. 90dBA buzzer mappable to user defined conditions. 3x push buttons for parameter setting or viewing on front panel. Serial bus for rectifier control and interface to peripheral modules. Fuse fail. 5x spare digital inputs. 2x temperature sensors. 3x current shunts. 2x DC voltage inputs. 3x alarm relays. 0.3A 100V volts free changeover contacts. Urgent. Non-urgent. Monitor fail. 16384 records. (dependant on number of parameters logged.) 16384 records. (dependant on number of parameters logged.) 111.5mm , 44mm (1U), 282mm overall (rack depth 260mm) 1.5kg Relay outputs, mini combicon to accept 1.5mm csa wire. Serial communications to rectifier shelf & peripheral devices - RJ45. USB port - USB mini B. -25 to +55C -50 to +85C EN55022 EN55024 3m temperature sensor and cable. 7m temperature sensor and cable. 3 phase AC voltage and current monitor. Battery condition monitor, 24 blocks. (maximum 4x BCM cards.) Standard I/O expansion board (maximum of 4 per supervisory module.) 15-75V DC <150mA maximum Connects via rectifier serial bus, 2x RJ45. Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Up to 6x digital inputs. Up to 6x analogue inputs. -25 to +55C -50 to +85C Standard 1U modular controller, 3x relays, 6x digital inputs. Standard 1U modular controller, 3x relays, 6x digital inputs; with standard I/O expansion board mounted onto baseplate metalwork. Standard 1U x 19 mounting version controller, 3x relays, 6x digital inputs. Standard 1U x 19 mounting version controller, 3x relays, 6x digital inputs; with standard I/O expansion board. Standard panel mount version controller, 3x relays, 6x digital inputs. Standard panel mount version controller, 3x relays, 6x digital inputs; with standard I/O expansion board.

48 | ENATEL | 2010 PRODUCT CATALOGUE

SM31 SUPERVISORY MODULE


Input Voltage: Current: Interface Display: Communications: Serial: Relay: LVD: Indicators: 3x LEDs Audible: Controls: Signal Inputs: Alarms: Alarm Contacts: Default Alarm Map: Logging Capacity: Periodic Log: Event Log: Physical Dimensions, W, H, D: Weight: Connections: Operating Temperature: Storage Temperature: Compliances Radiated Emissions: RF Susceptibility: Optional Accessories ACA-TC3C: ACA-TC7C: ASM-AC3P: ASM-ABM-24: ASM-SM3XIO: Voltage Range: Current: Connection: Alarms: Signal Inputs: Operating Temperature: Storage Temperature: Part Numbers SM31-00: SM31-10: SM31-00-1U: SM31-10-1U: SM31-00-PM: SM31-10-PM:

16-75V DC <150mA maximum.

4 line x 16 character multi-lingual alpha numeric display. 1x USB port on front panel for local PC interface. 3x alarm and control relays, two of which can be mapped for customized alarm settings. 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors) Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. 90dBA buzzer mappable to user defined conditions. 3x push buttons for parameter setting or viewing on front panel. 2x serial buses for rectifier control and interface to peripheral modules. Fuse fail. 5x spare digital inputs. 2x temperature sensors. 3x current shunts. 2x DC voltage inputs. 3x alarm relays. 0.3A 100V volts free changeover contacts. Urgent. Non-urgent. Monitor fail. 16384 records. (dependant on number of parameters logged.) 16384 records. (dependant on number of parameters logged.)

serial control for up to 126 rectifiers/ converters plus peripheral devices.

usb port for local connection.

126 LCD USB


lcd display.

111.5mm , 44mm (1U), 282mm overall (rack depth 260mm) 1.5kg Relay outputs, mini combicon to accept 1.5mm csa wire. Serial communications to rectifier shelf & peripheral devices - RJ45. USB port - USB mini B. -25 to +55C -50 to +85C

EN55022 EN55024

3m temperature sensor and cable. 7m temperature sensor and cable. 3 phase AC voltage and current monitor. Battery condition monitor, 24 blocks. (maximum 4x BCM cards.) Standard I/O expansion board (maximum of 4 per supervisory module.) 15-75V DC <150mA maximum Connects via rectifier serial bus, 2x RJ45. Up to 8x alarm and control relays, able to be mapped for customized alarm settings. Up to 6x digital inputs. Up to 6x analogue inputs. -25 to +55C -50 to +85C

Standard 1U modular controller, 3x relays, 6x digital inputs. Standard 1U modular controller, 3x relays, 6x digital inputs; with standard I/O expansion board mounted onto baseplate metalwork. Standard 1U x 19 mounting version controller, 3x relays, 6x digital inputs. Standard 1U x 19 mounting version controller, 3x relays, 6x digital inputs; with standard I/O expansion board. Standard panel mount version controller, 3x relays, 6x digital inputs. Standard panel mount version controller, 3x relays, 6x digital inputs; with standard I/O expansion board.
ENATEL | 2010 PRODUCT CATALOGUE | 49

SM11 SUPERVISORY MODULE

TEMP LVD LCD


temperature compensation. lvd control. lcd display of parameters.

Input Voltage: Current: Interface Display: Communications: Serial: Relay: Indicators: Controls: Signal Inputs: Alarms: Alarm Contacts: Alarm List: Physical Dimensions W, H, D: Weight: Connections: Operating Temperature: Storage Temperature: Versions SM11-12: SM11-24: SM11-48: Accessories Temp Sensor: ACA-TC2U: ACA-TC7U: Rectifier Interface: ACA-Alarm0.5: Current Sensor: ACS-S150:

35-60V DC <85mA maximum. 6 character starburst. Interfaces with up to 6x RF series rectifiers. RS232 serial for downloading configuration files. 7x alarm and control relays. 8x LED. 3x push buttons for parameter setting on front panel. External shutdown. Fuse fail. Rectifier fail. Mains fail. Rectifier off normal. 2x voltmeter. 2x current meter. (100mV) 7x alarm relays. 1A 100V volts free changeover contacts. Off normal. Rectifier fail. Mains fail. Float high. Float low. LVD. (control line for external LVD contactor) 275mm, 44mm (1U), 104mm 0.55kg Mini combicon to accept 1.5mm csa wire. -25 to +55C -50 to +85C 12V 24V 48V

2 metre temp sensor and cable. 7 metre temp sensor and cable. 500mm RJ45 patch cable. 150 Amp 100mV shunt assembly.

FAN CONTROLLER BOARD


- Uses the SM3X temp sensor to control fan speed. congurable to prevent fan stall. and up to 2x modules per system. - Individual minimum fan speed Up to two fan controller modules can be connected in a system, giving a total of 8 controlled fans. Each module operates individually and has separate settings, so can have different temperature set points and operate at different speeds. The fans on one module all operate at the same speed.
Input Voltage Range: Fan Voltage: Maximum Fan Current: Number Of Fans Controlled: Number Of Modules On Bus: Temperature Control Range: Communications: Alarms: Dimensions, W, H, D: Weight: Part Number: Fan Controller Board:
50 | ENATEL | 2010 PRODUCT CATALOGUE

The optional fan controller module allows the smart control of four 24V or 48V fans with fan stall detection.

- 4x fans controlled per module

16-75V DC 12V, 24V, 48V & 60V DC 300mA maximum per fan connection. 4x per fan controller module. (8x per system) 2x per system. The range of the SM3X temp sensor. Enatel serial bus interface. Controlled via SM3X fan fail. 90mm, 67mm, 25mm 61g

ASM-FCM4

BATTERY CONDITION MONITOR


The Enatel BCM consists of peripheral circuit boards that can be added to an Enatel system utilizing the SM22, SM32 or SM36 supervisory module to monitor the performance of the installed stand-by battery system. The monitor is designed to be connected to a number of different battery congurations with minimal changes to its conguration. The BCM includes the capability to log battery parameters during discharge and on a periodic time basis.
Voltage Resolution: Voltage Accuracy: Current Resolution: Current Accuracy: Temperature: Standard Configurations: Communications: Alarms: Data Logging: SM22: SM32: Mechanical Dimensions, W, H, D: Weight: Part Number Battery Condition Monitor: 0.01V 0.02V 1A 2A 2C (standard sensor, upgraded sensor available for 1C) 4 8 1 1 8 strings, 4 voltage measurements per string. (requires 1x PCB) strings, 2 voltage measurements per string. (requires 1x PCB) string, 24 voltage measurements per string. (requires 1x PCB) string, 12 voltage measurements per string. (requires 1x PCB) string, 4 voltage measurements per string. (requires 2x PCBs)

- Compatible with SM22, SM32 or SM36 supervisory modules. - 26 voltage inputs. - 8 pairs of current inputs. - 4 temperature inputs. - Discharge logging. - Periodic logging. - Ease of installation. - Compact design.

Enatel serial bus interface. Controlled via SM22, SM32 or SM36. Voltage symmetry fault. (based on deviation from average string block measurement) Battery current imbalance. (based on deviation from average string current across all strings in system) Battery temperature high. Battery temperature low. Battery string open. (detects string voltage deviation from system DC bus to conclude battery is disconnected from system) Utilization of supervisory module memory: 15,500 data points. 196,000 data points. Actual number of discharge events stored depends on frequency of discharges, logging interval and parameters measured. 80mm , 145mm, 27mm 100g ASM-ABM-24

AC MAINS MONITOR
The AC mains monitor can be added to the SM range of supervisory modules if AC supply metering is required. - Compatible with SM range of supervisory modules. - Ease of installation. - Compact design.
Communications: Alarms: Mechanical Dimensions, W, H, D: Weight: Part Number AC Mains Mointor: Enatel serial bus interface. Controlled via SM21, SM22, SM31, SM32, SM35 or SM36. Voltage phase high, voltage phase low, voltage phase lost. (separate alarms for each phase). AC phase current high. (common alarm for all phases) Frequency high, frequency low. 145mm, 15mm, 85mm 61.5g ASM-AC3P
ENATEL | 2010 PRODUCT CATALOGUE | 51

FTTX POWER SOLUTIONS


EPON INFRASTRUCTURE
Enatel have recognised the need for DC Power Supplies specically sized for Fibre to the Home requirements and developed a range of standalone and modular rectiers and Micro Compact Power Shelves to suit every application within the FTTX environment. Be it Central Ofce or Customer Premise we have the power solution to t. Enatel have two solutions to suit these applications:

SOHO / RESIDENTIAL APPLICATIONS


The SOHO (Small Ofce/Home Ofce) and residential market is going to have the largest requirement for DC systems. If the customer premise is tted with alarms, nurse call or any other monitored device they will need a battery backed DC supply to ensure communication is available during an AC outage.

CENTRAL OFFICE APPLICATIONS


Experience shows that the majority of Central Ofce OLT units have a power consumption of up to 1600W. Enatels Micro Compact Power System is perfect for this application having 3 x 800W rectiers gives an N+1 redundancy solution, built in distribution and full congured Supervisory Module.

nSURE NS300-12
For the SOHO Client Enatels nSURE NS300-12 can provide long term backup for all their communications needs. SOHO (Small Ofce/Home Ofce) clients with security systems will need Enatels nSURE NS300-12 power supply. Couple into this the ONU, Security system, residential gateway and wireless router and it can be business as usual from a laptop during an AC outage. The NS300-12 is wall mountable and convection cooled making it ideal for ofce locations. - 12V, 300W output.

OFFICE / APARTMENT APPLICATIONS


These ONTs range in power consumption from 60W to 500W, typically have dual DC feeds and are 19 rack mountable. Enatels Micro Compact range with 200W and 400W modules are purpose built for this application, giving optimum power output with space for redundancy and standby battery recharge in the event of an AC failure.

- Mains fail alarm. - Convection cooled. - Wall mountable. - Automatic oat/boost charge cycle. - Power factor corrected. - Thermally protected. - Input/output voltage and current protected.

MICRO COMPACT POWER SYSTEM


Enatels new range of Micro Compact Power Systems utilize Enatels intelligent controllers and modular rectiers. With rectier output ratings of 200, 400 and 800W and Supervisory modules capable of Ethernet communication as standard these 1U power shelves are ideal for FTTX solutions. They offer output power in line with the OLT /ONU usage and have the capacity for N+1 redundancy. With various output distribution options they cater to all the requirements of this growing market. - Micro compact size means more room for revenue generating equipment.

nSURE NS30-12
To suit the residential needs Enatel offers the nSURE NS30-12 (with integrated battery) for basic autodialer backup functionality. For home owners with alarm auto dialers FTTH means their alarms will not be monitored in the event of an AC Outage. Enatels nSURE NS30-12 provides battery backed power to the ONU even when the lights go out. Security or Nurse call devices will operate as normal. - Telecom grade 12V DC (30W max.) output. - Up to 8 hours* of standby battery backup. - Flexibility of wall or desktop mount. - Easy user replaceable battery without power interruption. - Microprocessor based intelligent control. - Cold start capable. - Local audible and visual indicators with remote alarms. - Optional extended runtime.

- World leading power density. - Fully featured telecom grade rectiers. - Network monitoring available. - Modular 19/515mm ETSI design for ease of installation. - High reliability means less cost of maintenance. - Full remote monitoring available means less site visits and less cost. suit each customers individual needs. - Easily customized and congured to

AC POWER SOLUTIONS
As some FTTX equipment is AC powered Enatel can also offer integrated DC-AC Inverters, this allows for a telecommunications grade UPS (Long backup times) on the entire FTTX system. The Inverters are monitored and controlled through the same controller as the rest of the DC Power system. Enatel can supply the complete solution in a wall mount cabinet or ready to integrate into the OLT/ONU mounting system.
52 | ENATEL | 2010 PRODUCT CATALOGUE

nSURE 1U MICRO COMPACT SYSTEM 0.8 - 2.4KW 48V DC


AC Input: AC Current: Frequency Range: Power Factor: Termination: Single phase. 170V AC, 15.0A max. 230V AC, 11.1A nominal. (refer to RM8xx, series brochures for full details) 45-66Hz >0.99 (full load) Single phase, 1.5m flying lead.

DC Output Nominal Voltage: Rated System Output Power: Polarity: DC Distribution: Load: Battery: 2x 10A, 2x 20A load circuit breakers. 2x 30A battery circuit breakers.
Supervisory Module

-48V 2400W max. (50A @ -48V; 44.4A @ -54.0V) Positive earth. (negative earth available to special order).

48 2.4
SM36
RM848 RM848 RM848

nominal output voltage.

maximum output power.

kW

Breaker Fail Detection: DC Terminals (Front Connected): Load: Battery:

Electronic fail detection on both load and battery breakers.

6mm push-in spring cage. 55A power-pole plug-in connectors.. 50A battery LVD (magnetically latching) fitted as standard.

Low Voltage Disconnect:

Mechanical Dimensions, W,H,D: Weight: 482.6mm (standard 19 module), also fits ETSI 515mm mounting cabinet, 44.45mm (1U, 1.75), 285mm (11.6) 5kg (excluding rectifier modules)

Shipping Dimensions, W,H,D: 540mm, 95mm, 400mm Weight: 6kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM35/36 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/ equalisation, 6x general purpose inputs and 6x voltage-free relay alarm outputs. For further details, refer to the SM35/36 series of brochures.

Accessories ACA-BC08P2: 2m, 8mm battery cable kit. (other lengths available to special order)

Part Numbers: PSX1606211F-000: PSX1606221F-000: PSX2404211F-000: PSX2404221F-000:

Actual part numbers will vary with configuration. Micro compact system, 2x 800W 48V rectifiers, 6x load 2x battery MCBs, front termination, SM35 supervisory module. Micro compact system, 2x 800W 48V rectifiers, 6x load 2x battery MCBs, front termination, SM36 supervisory module. Micro compact system, 3x 800W 48V rectifiers, 4x load 2x battery MCBs, front termination, SM35 supervisory module. Micro compact system, 3 x 800W 48V rectifiers, 4x load 2x battery MCBs, front termination, SM36 supervisory module.
ENATEL | 2010 PRODUCT CATALOGUE | 53

nSURE NS300-12

12 300
nominal output voltage.

AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Rush: DC Output Nominal Voltage: Rated Voltage: Voltage Range: Maximum Current: Regulation: Line: Load: Hold-up Time: Start-up Time: Protection: Current Limit: Over Temp: Polarity Reversal: Over Voltage: Noise: (under nominal conditions) Ripple <100Hz: Voice Band 100Hz to 5KHz: Wide Band 5kHz to 1 MHz: Peak to Peak 0 to 20MHz: Isolation: Input to Output: Input to Chassis: Output to Chassis: Environmental Requirements Nominal Ambient Temperature: Range: Humidity: Altitude: Mechanical Dimensions, W, H, D: Weight: Shipping Dimensions, W, H, D: Shipping Weight: Cooling: Connections: Mains: Output to Load: Output to batteries: Standard Features Auto Float/Boost: Alarm and Indicator Controls: Compliances: Safety: EN60950 Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation:

110/220V, 50/60Hz 100-275V AC (full power output), 85-100V AC (reduced power output) 45-66Hz >0.99 (full load) 85% HRC Fuses in phase & neutral. 4A Automatic shutdown, restarts automatically when correct voltage restored. <2x maximum input current.

maximum output power.

12V 14.5V 11.5-15V 20A 0.1% 0.5% (no load to full load) >15ms for 20% output voltage drop. Walk-in delay 2 seconds (depends on AC input voltage) Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Output fuse with crowbar diode. Adjustable limit. <5mV rms unweighted. <0.5mV rms psophometric. <2.5mV rms unweighted. <50mV p-p unweighted. 3000V AC 2500V AC (VDR to chassis removed.) 1500V AC

25+/-5C -10 to +60C 5-95% RH (non-condensing) <2500m de-rate maximum ambient temperature by +4 per 1000m above sea level.

311mm, 163mm, 62mm 1.5kg 377mm, 235mm, 122mm 2.4kg Convection cooled. IEC 320 universal connection. 4 way lumberg macromodule. 4 way lumberg macromodule.

Rectifier enters boost mode at power up. When battery current reduces to float threshold limit (adjustable from 0.1A to 40% MRC), unit reverts to float voltage setting. When in boost but out of current limit, rectifier will automatically switch back to float after approximately four hours. If battery current exceeds the float threshold limit when the rectifier is in float mode it will automatically switch to boost mode. Open collector rectifier fail (via 4k7 resistor), Open collector mains fail.

CISPR24 CISPR22 EN61000-3-2 EN61000-3-3

54 | ENATEL | 2010 PRODUCT CATALOGUE

nSURE NS30-12
Input Nominal Input Voltage: Voltage Range: Frequency Range: Plug Type: IEC inlet. 120V AC/230V AC 80-260V AC 45Hz-65Hz

Output Output Power (Max): Normal Voltage: Output Voltage Range: Line Mode Efficiency: 30W/2.2A 12V DC 10.5-13.8V DC >80%

maximum output power.

12 30

nominal output voltage.

Plug Type: 7pin terminal strip. (2 * DC output, 5 * dry contact alarms)

Battery Type/Rating: Discharge Prevention: Rated Charging Voltage: Recharge Time (Internal Battery): Charge Current: Hot Swappable Battery: 12V/7Ah x 1pc (12V/9Ah option) 10.5V 0.5V 13.7V 0.25 4 hours to 90% without load after discharge. 2.5A maximum. Yes.

Indicators AC Mode: Backup Mode: Battery Low: Battery Replace: Battery Missing: Fault: Battery Self Test: Solid green LED. Solid yellow LED. Flashing yellow LED. Flashing red LED. Flashing red LED. Flashing red LED. Flashing green LED.

Audible Alarm Backup Mode: Battery Low: Battery Replace: Battery Missing: Fault: Mute Function: 5 seconds. 1 second. 2 seconds. Continuous. Continuous. Switch. (on/off)

Environment Operating Temperature: Operating Humidity: Operating Elevation: 0 to 40C 0 to 90% 0 to 3000m

Physical Dimensions, W, H, D: Weight: 212mm, 216mm, 87mm 4.0Kg


ENATEL | 2010 PRODUCT CATALOGUE | 55

INDUSTRIAL SOLUTIONS
- World leading power density. - Fully featured telecom grade rectiers. Systems are congured using Enatels state of the art high frequency switch mode rectier modules, intelligent network capable controllers, AC & DC distribution modules, and cabinets, and can be customized and congured to meet individual customer requirements. For details on a Enatel power system that meets your requirements contact us. - Network monitoring available. - Modular 19 design for ease of installation. - Includes AC surge protection. - More room for revenue creating equipment. to higher power. of maintenance. means less site visits and less cost. - Upgrade existing systems - High reliability means less cost - Full remote monitoring available - Cost competitive. - Suitable for more harsh environments. Based on our proven range of modular telecom power solutions, we have developed a range of solutions for use in 110V DC industrial applications.

56 | ENATEL | 2010 PRODUCT CATALOGUE

2U ULTRA COMPACT SYSTEM 3.0 - 6.0kW 110V DC


AC Input: AC Current: Frequency Range: Power Factor: Termination: Single phase 90 300V AC 38A max / Ph (Ph-N) (refer to RM30110 brochure for full details) 45-66Hz >0.99 (full load) Single phase, 16mm2 L, N, E tunnel terminals at rear. Single phase surge protection. (40kA, 8/20 sec)

DC Output Nominal Voltage: Rated Voltage: Rated System Output Power: Polarity: 121.5V 80-155V DC
Supervisory Module

110 6.0
SM34

nominal output voltage.

maximum output power.

kW

6.0kW max @ 121.5V DC (50A) +60V / -60V

AC Input

Load

Battery

compact

ULTRA

HV

DC Distribution: Load: 1x 63A 2 pole load MCB (breaks +ve & -ve) 35mm tunnel terminals at rear. 1x 63A 2 pole battery MCB (breaks +ve & -ve) 35mm tunnel terminals at rear. Auxiliaries on both load and battery breakers. Configurable via software, factory set at 25mA

Battery:

Breaker Fail Detection: Earth Leakage Detection:

Mechanical Dimensions, W, H, D: Weight: 482.6mm (standard 19 module), 89mm (1U, 3.5), 415mm (16.3) 7.5kg (excluding rectifier modules)

Shipping Dimensions, W, H, D: 530mm, 154mm, 430mm Weight: 9kg (excluding rectifier modules)

Monitoring & Control:

Various monitoring options are available via the Enatel SM33/34 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs.

Part Numbers: PSC06021130-000: PSC06021140-000:

Actual part numbers will vary with configuration. 2U HV Ultra Compact Power System including standard SM33 supervisory module. 2U HV Ultra Compact Power System including standard SM34 supervisory module.
ENATEL | 2010 PRODUCT CATALOGUE | 57

WALL MOUNT BATTERY CHARGER 3.0kW 110V DC

110 3.0
nominal output voltage. maximum output power.

AC Input:

Single phase with surge protection and input 32A MCB (refer to rectifier brochure for full details) 45-66Hz >0.99 (full load) Single phase. Direct MCB termination for L. 10mm N, E tunnel terminals.

Frequency Range: Power Factor: Termination: Max Rated System Output Power: Polarity:

kW

110V (80-155V DC) 3000W @ 120V DC, 27A max. Isolated output. 1x RM30110 3000W rectifier.

DC Distribution: Load: Battery: 1x 63A 2 pole MCB. 1x 63A 2 pole MCB. Auxiliaries. Live: Direct MCB connections.

Breaker Fail Detection: DC Terminals:

Weight: Dimensions, D, H, W:

Approx. 10.5Kg 620mm x 375mm x 80mm

Shipping Dimensions, D, H, W: 730mm x 470mm x 200mm

Monitoring and Control:

Various monitoring options via the Enatel SM30 series of control & supervisory modules. Standard features include full temperature compensation, automated and manual battery testing/equalisation and three voltage-free relay alarm outputs. For further details, refer to the SM30 series of brochures.

Part Numbers: PSW-3111030-000: PSW-3111040-000:


58 | ENATEL | 2010 PRODUCT CATALOGUE

Actual part numbers will vary with congifuration. Wall mount charger including standard SM33 supervisory module. Wall mount charger including standard SM34 supervisory module.

RM30110 3.0KW 110V DC MODULAR RECTIFIER


AC Input Nominal: Voltage Range: Frequency Range: Power Factor: Efficiency: Input Fuses: Maximum Input Current: Protection: Input Voltage: Input Inrush:

230V 90-300V (reduced power below 175V) 45-65 Hz >0.99 >92% (>45% output power) HRC fuses in phase and neutral. 19A Auto shutdown, auto restart when correct voltage restored. <2x maximum input current.

DC Output Output Ratings: Constant Current: 80-110V DC (27.3A) Constant Power: 110-155VD C (3.0kW) Nominal Voltage: 120V Rated Voltage: 145V Voltage Range: 80-155V Maximum Current: 27.3A Regulation: Line: 0.1% 0.5% (no load to full load) Load: Hold-up Time: >15ms for 20% output voltage drop. Start-up Time: Start up delay 1 second. (varies with AC supply voltage) Walk-in delay 6 seconds at full output. (varies with DC output voltage) Protection: Current Limit: Adjustable to 50-100% of maximum rated current. Automatic current turndown, backup shutdown protection. Over Temperature: Polarity Reversal: Output fuse with crowbar diode. Over voltage: Adjustable limit. Noise: (under nominal conditions) Ripple <100Hz: <1mV rms unweighted. Voice band 100Hz-5KHz: <2mV rms psophometric. Wide band 5kHz-1MHz: <5mV rms unweighted Peak to Peak 0-20MHz: <200mV peak to peak. Isolation: Input to Output: 4000V DC Input to Chassis: 3500V DC (VDR to chassis removed) Output to Chassis: 2100V DC Environmental Requirements Ambient Temperature: Nominal: Range: Storage Temperature: Humidity: Altitude:

110 3.0 27.3

nominal output voltage.

nominal output power.

kW

maximum output current.

25+/-5C -10C to +70C (maximum output power is derated above +50C) -20C to +70C 5-95% RH (non-condensing) <2500m, De-rate maximum ambient temperature by 4C per 1000m above sea level.

Mechanical Dimensions, W, H, D: 41mm, 220mm, 305mm overall. Weight: 2.8kg Shipping Dimensions W, H, D: 52mm, 230mm, 340mm Shipping Weight: 2.95kg Cooling: Forced cooled, using dual temperature controlled high reliability fans. Compliances Safety: Electrostatic Discharge: Radiated Radio Frequency: AC Harmonics: AC Flicker and Fluctuation: Other:

EN60950 CISPR24 CISPR22 EN61000-3-2 EN61000-3-3 CE & RoHS compliant.


ENATEL | 2010 PRODUCT CATALOGUE | 59

SM34 SUPERVISORY MODULE

LVD WEB USB


dual lvd control. web based configurator. usb port for local connection.

Input Voltage: Current: Interface Display: Communications: Serial: Relay: TCP/IP: LVD: 1x USB port on front panel for local PC interface. 1x RS232 port, rear mounted for remote serial/modem communications. 3x alarm and control relays, two of which can be mapped for customized alarm settings. Ethernet interface for communication using SNMP protocol and internal web based configurator. 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors) Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. 90dBA buzzer mappable to user defined conditions. 3x push buttons for parameter setting or viewing on front panel. Serial bus for rectifier control and interface to peripheral modules. Fuse fail. 5x spare digital inputs. 2x temperature sensors. 3x current shunts. 2x DC voltage inputs. 3x alarm relays. 0.3A 100V volts free changeover contacts or 0.15A 160V volts free changeover contacts. Urgent. Non-urgent. Monitor fail. 16384 records. (dependant on number of parameters logged.) 16384 records. (dependant on number of parameters logged.) 4 line x 16 character multi-lingual alpha numeric display. 80-160V DC <50mA maximum.

Indicators: 3x LEDs Audible: Controls: Signal Inputs: Alarms: Alarm Contacts: Default Alarm Map: Logging Capacity: Periodic Log: Event Log:

Physical Dimensions, W, H, D: Weight: Connections: Operating Temperature: Storage Temperature: Compliances Radiated Emissions: RF Susceptibility: Optional Accessories ACA-TC3C: ACA-TC3C: ASM-AC3P110: ASM-ABM-24: Part Numbers SM34-00: SM34-00-1U: SM34-00-PM:
60 | ENATEL | 2010 PRODUCT CATALOGUE

111.5mm , 44mm (1U), 282mm overall (rack depth 260mm) 1.5kg Relay outputs, mini combicon to accept 1.5mm csa wire. Serial communications to rectifier shelf & peripheral devices - RJ45. USB port - USB mini B. -25 to +55C -50 to +85C

EN55022 EN55024

3m temperature sensor and cable. 7m temperature sensor and cable. 3 phase AC voltage and current monitor. Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)

Standard 1U modular controller, 3x relays, 6x digital inputs. Standard 1U x 19 mounting version controller, 3x relays, 6x digital inputs. Standard panel mount version controller, 3x relays, 6x digital inputs.

SM33 SUPERVISORY MODULE


Input Voltage: Current: Interface Display: Communications: Serial: Relay: LVD: 1x USB port on front panel for local PC interface. 3x alarm and control relays, two of which can be mapped for customized alarm settings. 3x standard or 2x pulse control LVD contacts. (for magnetically latched LVD contactors) Green - power on/monitor OK. Yellow - non urgent alarm. Red - urgent alarm. 90dBA buzzer mappable to user defined conditions. 3x push buttons for parameter setting or viewing on front panel. 2x serial buses for rectifier control and interface to peripheral modules. Fuse fail. 5x spare digital inputs. 2x temperature sensors. 3x current shunts. 2x DC voltage inputs. 3x alarm relays. 0.3A 100V volts free changeover contacts or 0.15A 160V volts free changeover contacts. Urgent. Non-urgent. Monitor fail. 16384 records. (dependant on number of parameters logged.) 16384 records. (dependant on number of parameters logged.) 4 line x 16 character multi-lingual alpha numeric display. 80-160V DC <50mA maximum.

serial control for up to 126 rectifiers/ converters plus peripheral devices.

Indicators: 3x LEDs Audible: Controls: Signal Inputs: Alarms: Alarm Contacts: Default Alarm Map: Logging Capacity: Periodic Log: Event Log:

usb port for local connection.

126 LCD USB


lcd display.

Physical Dimensions, W, H, D: Weight: Connections: Operating Temperature: Storage Temperature: Compliances Radiated Emissions: RF Susceptibility: Optional Accessories ACA-TC3C: ACA-TC7C: ASM-AC3P110: ASM-ABM-24: Part Numbers SM33-00: SM33-00-1U: SM33-00-PM: Standard 1U modular controller, 3x relays, 6x digital inputs. Standard 1U x 19 mounting version controller, 3x relays, 6x digital inputs. Standard panel mount version controller, 3x relays, 6x digital inputs.
ENATEL | 2010 PRODUCT CATALOGUE | 61

111.5mm , 44mm (1U), 282mm overall (rack depth 260mm) 1.5kg Relay outputs, mini combicon to accept 1.5mm csa wire. Serial communications to rectifier shelf & peripheral devices - RJ45. USB port - USB mini B. -25 to +55C -50 to +85C

EN55022 EN55024

3m temperature sensor and cable. 7m temperature sensor and cable. 3 phase AC voltage and current monitor. Battery condition monitor, 24 blocks. (maximum 4x BCM cards.)

62 | ENATEL | 2010 PRODUCT CATALOGUE

Copyright Enatel Limited 2010. Due to product development specications are subject to change without prior notice. Pictures may be representative, actual products may differ.

321 Tuam Street PO Box 22-333 Christchurch New Zealand

Phone +64-3-366 4550 Fax +64-3-366 0884 Email sales@enatel.net www.enatel.net

You might also like