COOLING SYSTEMS

L5790GSI, 7044GSI and L7042GSI AUXILIARY WATER PUMP PERFORMANCE SPECIAL FOR GAS COMPRESSOR SERVICE INTERCOOLER - OIL COOLER COMPRESSOR SERIES CIRCUIT WATER PUMP #169561-A; 10 INCH DRIVE PULLEY; 2.76:1 DRIVE RATIO OIL COOLER #211857

mbar

psi

5520

80.0
MAX. SYSTEM RESTRICTION MAX. FLOW

HEAD RESTRICTION (psi)

1200 ENGINE RPM

4140

60.0

1000 RPM

2760

40.0
800 RPM

1380

20.0

600 RPM ENGINE RESTRICTION

0.0
GPM l/min.

0 0

20 75

40 150

60

80

100 375

120 450

140 525

225 300 FLOW (gpm)

ENGINE RPM DESIGN FLOW GPM (l/min) MAX. SYSTEM RESTRICTION psi (mBAR) MAX. EXTERNAL RESTRICTION psi (mBAR) NOTES:

600 39 (148) 14.4 (993) 9.8 (676)

800 53 (201) 26.1 (1800) 18.5 (1276)

1000 66 (250) 40.6 (2799) 30.2 (2082)

1200 79 (299) 58.5 (4034) 44.2 (3048)

1. Pump flows are based on a positive suction pressure at the pump inlet. 2. PSI x 68.95 = mBar. PSI x 6.895 = kPa. 3. GPM x 3.785 = l/min. 4. Maximum auxiliary circuit flow = 127 GPM. 5. For use with accessory Code 4352B.

Page 1 of 1

AUXILIARY WATER PUMP PERFORMANCE SPECIAL FOR GAS COMPRESSOR SERVICE MODELS L5790GSI, 7044GSI AND L7042GSI

EN: 123784 DATE: 7/99

Ref.

S 6543-36