L5790GSI, 7044GSI and L7042GSI AUXILIARY WATER PUMP PERFORMANCE SPECIAL FOR GAS COMPRESSOR SERVICE INTERCOOLER - OIL COOLER COMPRESSOR SERIES CIRCUIT WATER PUMP #169561-A; 10 INCH DRIVE PULLEY; 2.76:1 DRIVE RATIO OIL COOLER #211857
mbar
psi
5520
80.0
MAX. SYSTEM RESTRICTION MAX. FLOW
4140
60.0
1000 RPM
2760
40.0
800 RPM
1380
20.0
0.0
GPM l/min.
0 0
20 75
40 150
60
80
100 375
120 450
140 525
ENGINE RPM DESIGN FLOW GPM (l/min) MAX. SYSTEM RESTRICTION psi (mBAR) MAX. EXTERNAL RESTRICTION psi (mBAR) NOTES:
1. Pump flows are based on a positive suction pressure at the pump inlet. 2. PSI x 68.95 = mBar. PSI x 6.895 = kPa. 3. GPM x 3.785 = l/min. 4. Maximum auxiliary circuit flow = 127 GPM. 5. For use with accessory Code 4352B.
Page 1 of 1
AUXILIARY WATER PUMP PERFORMANCE SPECIAL FOR GAS COMPRESSOR SERVICE MODELS L5790GSI, 7044GSI AND L7042GSI
Ref.
S 6543-36