Divertor and Changeover Valves Type 06510 - Divertor Valve

Cryogenic Divertor Valves, bronze, PN50 for the installation of two safety valves, provided for bursting disc connections, "cleaned and degreased for oxygen service" Artikel-Nr. 06510.X.0120 Female thread connection (G) acc. to ISO 228/1 Artikel-Nr. 06510.X.6000 Female thread connection NPTF acc. to ANSI B 1.20.1

Available Options - on request only: Inlet with union type braze or butt weld fitting two extra test connections 1/4'' edgeways Outlet GA1 with installed locking sleeve for easy positioning of safety valves Combination of different outlet threads GA1 - GA2

Applications: Approved for air gases, vapours and cryogenic liquefied gases incl. LNG. Working temperature: -196C / -321F (77K) up to +120C / +248F (393K)
Materials 1 Body I 2 Body II 3 Ball 4 Seat rings 5 Bush 6 Spring plates 7 Spring clamp 8 Thread ring 10 Stem 11 Gland packing 12 Lever DIN EN ASTM CC491K B 62 UNS C83600 CC491K B 62 UNS C83600 1.4571 A 276 Grade 316Ti PCTFE CW614N B 283 UNS C38500 1.4571 A 276 Grade 316Ti CW614N B 283 UNS C38500 CW614N B 283 UNS C38500 1.4301 A 276 Grade 304 Graphit / PTFE CC491K B 62 UNS C83600

Standard marking acc. to Pressure Equipment Directive 97/23/EG (PED).


Type 06510 - Standard design Nominal size Dimension code Flow diameter Inlet Outlet Outlet Face-to-face dimension Length Height Length Length Length Thread depth Weight Kvs - Value, one side open Cv - Value, one side open
Dimensions in mm.
Edition 2013-07

Technical data DN 32 .X. 3210 d0 30 GW 1-1/2 GA1 1-1/4 GA2 1-1/4 FF 284 a 210 b 145 f 245 g 160 h 60 i 12.5 ca. kg 13.5 m3 /h 16.7 gal /min 19.4

32 3214 30 1-1/2 1-1/2 1-1/2 284 210 145 245 160 60 12.5 13.5 16.7 19.4

Important: The valves must be fixed at the provided threads M12.

HEROSE GMBH Phone +49 4531 509-0 Fax +49 4531 509 120 info@herose.com www.herose.com