Blockbody Valves

You might also like

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 13

BlockBody Valves

TM
Extends Catalog Capabilities

EXCEEDS

CONFORMS
TO CODE
The Crosby BlockBody TM

Safety/Relief Valve Design

The Ultimate in
Safety and
Reliability
Available Designs:
• Conventional (JOS)
• Balanced Bellows (JBS)
• Balanced Piston (JBS-BP)

• Internals based on standard design


• Valve Superstructure (Body, Bonnet & Cap) manufactured
from solid forged blocks
• Fully rated outlets up to 2500 lb. available
• Set pressure upto 10000 psig (dependent on size)
• API-526 pressure limits can be greatly exceeded
• No welding used in construction
• Extensively flow tested and proven design
• Special dual outlet design available to counterbalance
reaction forces
• Available in D (0.110 IN2) to T2 (27.872 IN2) sizes
Design Details
• Full nozzle design for maximum tightness
• Geometric reduced main valve block for
additional weight saving
• Dissimilar materials used for guiding surfaces to
eliminate galling
• Interference fitted inlet studs provide greater
stability in service
• Wrought materials eliminate confines of cast
materials i.e. Weld & NDE
BlockBody
TM

PILOT
VALVES
Available Materials
• Carbon Steel This is a selection of only
what has been supplied
• Impact Tested Carbon Steel before. Any metal can be
• Stainless Steel considered.

• High Temperature Alloy Steel


• Monel, Hastelloy and Titanium
• 22% and 25% CR. Duplex Stainless Steel
(UNS S31803 UNSA S32550 UNS S32760) for
High Corrosive High Strength Duties
• 6 Mo Super Austenitic Stainless Steel
(UNS S31254) for very Harsh Seawater Duties
Features and Benefits
• One Single Crosby Block Body Installation
can handle the capacity of 12+ API-526
standard valves

• One Installation Means


– Fewer Potential Leak paths
– Less Down Time and Maintenance
– Few Spare Parts Required
– Less Total Weight in Offshore Use
– Major Cost Savings on Inlet and
Outlet Piping
Tips
• Multiple Valves on same Vessel
example: Customer Specification
2720 psi set at 450 F
4.5 sq. in. orifice area
Sizing = P orifice (6.38)
H orifice (.785) is first orifice to
meet pressure/temp requirement
• Special Materials
- Cast
- Wrought
• Special Flange Ratings
- i.e. 600 x 600
Typical Designs
• 6” x Q x 8” x 8” JBS-D-65 BLK-G-SPL (Dual Outlet
1500 lb x 300 lb set 2726 psig (API Max = 600 psig)
• 1 1/2” x D x 2 1/2” JLT-JBS-75-BLK-S-G
2500 lb x 2500 lb Fully Rated Inlet and Outlet
• 6” x Q x 8” JBS-45-BLK-S-G-SPL
600 lb x 300 lb in Duplex with Limit Switch
• 4” x P x 6” JBS-55-BLK-APPA with Actuator
• 6” x 4.645 x 10 JBS-55-BLK set at 2074 psi
Proven Performance..Satisfied Customers