DESIGN
CALCULATION SHEET
--Sheet No. of
Subject Building
Checked by _
SECTION PROPERTIES
TOTAL THICKNESS (t) BRIDTH (b) COMPRESSION STEEL COVER (d') TENSION STEEL COVER (c) TENSION STEEL DEPTH (d) = = = = = 15.00 100.00 0.00 3.50 11.50 Cm Cm Cm Cm Cm
STRAINING ACTION
ULTIMATE MOMENT (MU) REDISTRIBUTION RATIO (d) = = 3.5 0.85 m.t.
STEEL REINFORCEMENT
K YCT X = = = = = = = 0.076 10.653 2.036 0.779 0.000 8.96 0.00 Cm Cm % % Cm2 Cm2
r r'
TENSION STEEL AREA (AS) COMPRESSION STEEL AREA (AS') TENSION STEEL
COMPRESSION STEEL
8 10 12 16 18 20 22 25 30 32 5 4 3 3 2 2 2
f
n
8 10 12 16 18 20 22 25 30 32 0 0 0 0 0 0 0 0 0 0
n 18 12 8
EQUATIONS USED
K = MU/b/d2/FCU d ( 0.5 + SQR( 0.25 - 9.0 * K / 8.0)) ( d - YCT) / 0.45 1.15 * MU / FY / YCT 0.775 * d 0.5 * d 1.15 * ( K - 0.155 ) * FCU * b * d2 / FY / ( d - d' ) 0.17825 * FCU * b * d2 / FY / YCT + AS' =< 0.95 d
IF K > 0.155