MV Lubie: Wartsila Sulzer 6RTA48T-B ME Rotation: Anticlockwise Anticlockwise
MV Lubie: Wartsila Sulzer 6RTA48T-B ME Rotation: Anticlockwise Anticlockwise
16/09/2013 Montreal 17
CRANKSHAFT DEFLECTION
Unit for measuring and calculating: Jacket cooling water temperature:
Difference Good values Values still admissible Cyl No: B1 EXH TOP CAM B2 a 1 0 -4 2 15 -2 3.0 2 0 9 17 11 6 14.0 a = a T.D.C. - a B.D.C. a = 0 - 0,31 mm a = 0,31 - 0,62 mm 3 0 9 6 8 -3 7.5 4 0 1 -1 2 2 -2.0 5 0 4 -4 1 2 -5.0 6 0 7 9 7 -2 10.0
hrs m m m 1/100 mm o 82 C
PS
SB
Top
1 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 2
1 -2.5
6 7 2.5 -2.8 5
1/100mm