Users Manual: Multimeter
Users Manual: Multimeter
Multimeter
Users Manual
1991-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies.
10 MULTIMETER
m m
Mk
SELECT
RANGE
OFF
VDC VAC
600V
COM
+
acz06f.eps
10 Users Manual
Contents
Page 2 3 4 5 6 6 7 8 10 10 12 14 14 15 1
Read First -- Safety Information.................................................................. Contacting Fluke for Service, Accessories, or Parts ................................... Standby Mode ............................................................................................ Operating Features..................................................................................... Using Accessories ...................................................................................... Symbols ...................................................................................................... Using the Autorange and Manual Range Modes ........................................ Measuring Voltage...................................................................................... Testing Continuity And Measuring Resistance ........................................... Turning the Beeper Off ............................................................................... Testing Diodes............................................................................................ Maintenance ............................................................................................... Replacing the Battery ................................................................................. Specifications..............................................................................................
10 Users Manual
10 Users Manual
Replace Battery
Digital Reading
m m
Manual Range
Mk
Measurement Units
Diode Test
Note: Before using, peel off plastic lens protector, starting at any corner.
acz01f.eps
Figure 1. Display
Standby Mode
In Standby mode, the display goes blank to preserve battery life. The meter beeps and enters Standby if it is LEFT ON BUT IS INACTIVE for more than 45 minutes. Press any button to resume operation. 4
Operating Features
Operating Features
Toggle Between Volts DC and AC, or Continuity and Ohms Ranging Operations 3-Position Slide-Switch Volts DC/AC Position Common (Return) Jack
OFF
SELECT
RANGE
VDC VAC
600V
COM
Input Jack
acz02f.eps
10 Users Manual
Using Accessories
When using accessories, put the slide-switch in the volts position. For ease of reading, manually select the 4000 mV range. In the 4000 mV range, 1 mV corresponds to 1 unit being measured by the accessory.
Symbols
W B F t N
Important Information; see manual AC (Alternating Current) DC (Direct Current) Underwriters Laboratories, Inc Battery. Low Battery on Display.
G J T # R
Diode Earth Ground Double Insulation VDE (Verband Deutscher Electroniker) Continuity Beeper
10 Users Manual
Measuring Voltage
1. 2. 3. Insert the test leads in the jacks. To select a voltage function, put the slide-switch in the middle position. (Figure 3.) Press the [ ] SELECT button to toggle between dc and ac. Touch the probes to the test points, and read the display. The meter beeps when OL (overload) is displayed.
Measuring Voltage
Volts DC
10 MULTIMETER
Volts AC 4
10 MULTIMETER
SELECT
SELECT
RANGE
2
OFF
RANGE
OFF
2
VDC VAC
600V
VDC VAC
600V
COM
COM
3
acz03f.eps
10 Users Manual
10
Resistance
10 MULTIMETER
Continuity Test 4
10 MULTIMETER 10 MULTIMETER
SELECT
SELECT
SELECT
2
OFF
RANGE
2
OFF
RANGE
RANGE
OFF
VDC VAC
600V
VDC VAC
600V
VDC VAC
600V
COM
COM
COM
3 Short
3 Open
acz04f.eps
11
10 Users Manual
Testing Diodes
1. 2. Insert the test leads in the jacks. Put the slide-switch in the continuity / ohms position. The meter selects either the continuity / diode ( R G ) or ohms (e) function. If ohms is selected, press [ ] SELECT to toggle to the continuity/diode function. To toggle the beeper on or off in continuity/diode test, press [Z} RANGE. When the beeper is enabled, R is displayed. 3. 4. Touch probes to the diode (Figure 5A). A forward-voltage drop of about 0.6 V (typical for a silicon diode) causes the meter to beep once. Reverse probes (Figure 5B). If the diode is good, OL is displayed. If the diode is shorted (Figure 5C), the beeper sounds continuously in at least one direction. If the diode is open, OL is displayed in both directions.
12
Testing Diodes
10 MULTIMETER
10 MULTIMETER
10 MULTIMETER
SELECT
SELECT
SELECT
2
OFF
RANGE
RANGE
RANGE
OFF
OFF
VDC VAC
600V
VDC VAC
600V
VDC VAC
600V
COM
COM
COM
3 A B
4 C
acz05f.eps
13
10 Users Manual
Maintenance
W Warning
To avoid electrical shock or damage to the meter, do not get water inside the case, and remove the test leads and any input signals before opening the case.
Wipe the case with a damp cloth and detergent. Do not use abrasives or solvents.
) appears to avoid
To replace the battery: 1. 2. 3. Turn the meter OFF and remove the test leads from the meter. Remove the four screws from the back of the meter and lift off the front. Remove the battery and replace it with a 9 V battery (NEDA 1604 or IEC 6F22).
14
Specifications
Specifications
This meter complies with Part 15 of FCC Rules. Operation is subject to the following conditions: 1. 2. This meter may not cause harmful interference. This meter must accept any interference received, including interference that may cause undesired operation.
Accuracy is specified for a period of one year after calibration, at 18 C to 28 C (64 F to 82 F) with relative humidity to 90 %. AC conversions are ac-coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy Specifications are given as: +/- ( [ % of reading ] + number of least significant digits ] )
15
10 Users Manual
Maximum Voltage Between any Terminal and Earth Ground Display Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Battery Type Battery Life Shock, Vibration Size (H x W x L) Weight Safety 600 V rms 3 3/4-digits, 4000 counts, updates 4/sec 10 C to 50 C 30 C to 60 C indefinitely (to 40 C for 100 hrs) 0.1 x (specified accuracy) / C (<18 C or >28 C) 0 % to 90 % (10 C to 35 C); 0 % to 70 % (35 C to 50 C) 9V, NEDA 1604 or IEC 6F22 Alkaline, 650 hrs continuous; Carbon-zinc, 450 hrs continuous 1 meter shock. Vibration per MIL-T-28800D for a Class 3 Instrument 1.35 x 2.75 x 5.55 inches; (3.46 x 7.05 x 14.23 cm) 10 oz (286 g) Complies with Protection Class II requirement of UL1244, ANSI/ISA-S82, CSA C22.2 No 231, and VDE 0411, and IEC 1010 overvoltage CAT III. CAT III instruments are designed to protect against transients in fixed-equipment installations at the distribution level. Complies with FCC Part 15, Class B, and VDE 0871B.
EMI Regulations
16
Specifications
Function Range 4000 mV * 4.000 V 40.00 V 400.0 V 600 V 4000 mV * 4.000 V 40.00 V 400.0 V 600 V 400.0 4.000 k 40.00 k 400.0 k 4.000 M 40.00 M 2.000 V Resolution 1 mV 0.001 V 0.01 V 0.1 V 1V 1 mV 0.001 V 0.01 V 0.1 V 1V 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M 0.001 V Accuracy (50 to 400 Hz) +/- (2.9 % + 3) +/- (2.9 % + 3) +/- (2.9 % + 3) +/- (2.9 % + 3) +/- (2.9 % + 3) +/- (1.5 % + 2) +/- (1.5 % + 2) +/- (1.5 % + 1) +/- (1.5 % + 1) +/- (1.5 % + 1) +/- (1.5 % + 2) +/- (1.5 % + 1) +/- (1.5 % + 1) +/- (1.5 % + 1) +/- (1.5 % + 1) +/- (1.9 % + 3) +/- (1.5 % + 2) **
VB
VF
RG
* The 4000 mV range can only be entered in manual range mode. Use the 4000 mV range with accessories. ** The beeper is guaranteed to come on at <25 and turn off at >250. The meter detects opens or shorts of 250 s or longer. 17
10 Users Manual
Input Impedance (Nominal) >10 MQ <100 pF 50 Hz or 60 Hz >5 MQ <100 pF (ac-coupled) Open Circuit Test Voltage 600 V rms < 1.5 V dc 2.4 to 3.0 V dc Common Mode Rejection Ration (1 kQ Unbalance) 100 dB @ dc @ 50 or 60 Hz >60 dB, dc, 60 Hz Full Scale Voltage To 4.0 M <450 mV dc 40 M <1.5 V dc <500 A 0.95 mA typical
Function
VF VB
600 V rms
2.400 V dc
* 3 x 106 V Hz Maximum
18