CODE COURSE NAME DAYS
CONTENTS
Need for switchgear, LV switchgear terminologies, product standards, fault current calculation for LV system, Selection & application of low voltage switchgears - like contactors, thermal overload relays, motor starters, HRC fuses, SDF units, MCCBs, ACBs with microprocessor releases etc. along with their accessories, advanced motor protection with microprocessor based motor protection relays, MCBs/ELCBs/DBs, brief overview of soft starters, drives for motors, busbar trunking, timers, panel accessories, capacitor selection for P.F. improvement, brief overview of MV switchgear & building automation. Classroom sessions supported by workshop demonstrations. Safety & good maintenance practices, complete hands-on workshop sessions on testing, troubleshooting & maintenance of low voltage switchgear such as contactors, overload relays, motor starters, MCCBs, ACBs, etc., good termination practices to LV switchgear, fitting, setting & testing of various types of accessories / releases on circuit breakers, testing of capacitors.
FOR WHOM
Engineers / technical team members from consulting firms, panel builders, projects, OEMs, industries, contractors, end users etc., involved in selection of switchgear & automation products
LT01
12,500
LT02
BEST MAINTENANCE PRACTICES IN LV SWITCHGEAR BREAKER MAINTENANCE WORKSHOP C POWER ACB BREAKER MAINTENANCE WORKSHOP U POWER ACB
12,500
LT03
Thorough hands-on training on C-Power range of Air Circuit Breakers, testing, setting & programming of various types of ACB microprocessor based protection releases like SR-71/SR21i & accessories, manual & electrical ACB, overview of control circuit-closing & tripping with master trip relay, introduction to U-Power ACBs. Complete hands-on training on U-Power range of air circuit breakers including pole assembly replacement. fixing & testing of various accessories. Testing, setting & programming of various types of microprocessor based releases.
6,000
LT04
6,000
LT05
Introduction to various standards for LV switchboard assembly , types of panels, forms of seperation, fault current calculations as applicable to low voltage switchgear, bus bar selection & design, selection of current transformers, cable selection, sizing of control transformers, earthing as applicable to LV switchboards, ingress protection(IP), good termination practices. Type tests & routine tests as applicable to LV switchboards, classroom sessions with practical case studies. Design of electric power distribution systems for large buildings, selection of equipment such as transformers, low voltage switchgear, distribution boards, BBT, MCBs, ELCBs, wires, etc., fault current calculations, voltage drop calculations, earthing as applicable to building electrical installations, relevant IE rules, etc. Classroom sessions supported by workshop demonstrations.
Engineers / technical team members from consulting firms, panel builders, projects, OEMs, industries, contractors, end users etc., involved in electrical design of switchboards Engineers working on electrical systems in projects, residential buildings, commercial complexes, hotels, hospitals, etc. Engineers working on electrical/ automation systems in projects, premium residential buildings, commercial complexes, hotels, hospitals, etc. Electrical / electronic / instrumentation engineers handling motors & drives in industries & OEMs Electrical engineers working with consultants, panel builders, contractors, industries, commercial establishments, etc.
9,000
LT06
POWER DISTRIBUTION IN BUILDINGS INTELLIGENT BUILDING MANAGEMENT SYSTEMS SELECTION & APPLICATION OF MOTORS & DRIVES REACTIVE POWER & HARMONICS MITIGATION INTRODUCTION TO MEDIUM VOLTAGE SWITCHGEAR INDUSTRIAL PROTECTION WITH NUMERICAL RELAYS CONSERVATION & MANAGEMENT OF ELECTRICAL ENERGY REQUIREMENT OF SYSTEM & EQUIPMENT EARTHING
9,000
LT07
Introduction to BMS covering concepts of EMS, lighting control, access control, HVAC and control systems. Basics of fire alarm system. Concepts of IBMS. Classroom sessions supported by workshop demonstrations. Basics of LV motors, duty classes, IP codes, IC codes, mounting, service conditions, selection of motors, energy efficient motors, inverter duty motor, basics of LV AC VFDs, selection & application of AC VFDs, wiring diagram, parameter setting, salient features, energy conservation with AC VFDs, VFD vs soft starter. Classroom sessions supported by workshop demonstr ations. What is PF, types of LV capacitors, selection criteria, power factor improvement - concepts, methods & advantages, APFC panels, dynamic compensation, harmonics in power systems, source, types, harmful effects & mitigation of harmonics - overview of passive & active filters. Classroom sessions with practical case studies. Selection & application of vacuum circuit breaker, specification of vacuum circuit breaker, fault current calculation, vacuum vs SF6 as a medium of CB, MV metal clad panel, MV panel bus bar design, installation, testing and commissioning of MV panel & introduction to protection of MV switchgear. Classroom session supported by workshop demonstration. Introduction to protective relaying, terminologies, ANSI codes, CTs, PTs, fault current calculations, relay co-ordination, feeder protection, motor protection, transformer protection, generator protection. Classroom sessions supported by workshop demonstrations. Importance of energy conservation & management, fundamental concepts of ECM, terminologies, software, energy efficient technologies in electrical installations, Energy Conservation Act, ECBC, etc. Need & purpose of earthing, various types & methods of earthing, selection of earthing system, system & equipment earthing, sizing of earth conductors, generator earthing, transformer earthing, earthing of sensitive electronic equipment, earth electrodes, measurement of earth resistance, earthing design, earth mat design, relevant rules, standards & regulations, lightning protection, good earthing practices.
9,000
LT08
9,000
LT09
9,000
LT10
LT11
Electrical engineers working with consultants, panel builders, projects, contractors, operation & maintenance of electrical equipment, testing agencies, electrical utilities, etc.
6,000
15,000
LT12
Electrical engineers working in design, consultancy, projects, operation & maintenance, etc.
6,000
LT13
Electrical engineers working with consultants, panel builders, projects, contractors, operation & maintenance personnel, etc.
7,000
LT14
3,000
Training Calendar
April 2013 to March 2014
CODE COURSE NAME
PUNE
PUNE
DAYS
2013 2013 2013 2013 2013 2013 2013 2013 2013 2014 2014 2014
LT01
5-9
2-6
LT02
BEST MAINTENANCE PRACTICES IN LV SWITCHGEAR BREAKER MAINTENANCE WORKSHOP C POWER ACB BREAKER MAINTENANCE WORKSHOP U POWER ACB
15-19 6-10 10-14 8-12 19-23 23-27 21-25 25-29 16-20 27-31 17-21 24-28
LT03
27-29
1-3
26-28
28-30
2-4
3-5
LT04
15-17
22-24
11-13
11-13
27-29
24-26
LT05
22-24
20-22
LT06
POWER DISTRIBUTION IN BUILDINGS INTELLIGENT BUILDING MANAGEMENT SYSTEMS SELECTION & APPLICATION OF MOTORS & DRIVES REACTIVE POWER & HARMONICS MITIGATION INTRODUCTION TO MEDIUM VOLTAGE SWITCHGEAR INDUSTRIAL PROTECTION WITH NUMERICAL RELAYS CONSERVATION & MANAGEMENT OF ELECTRICAL ENERGY REQUIREMENT OF SYSTEM & EQUIPMENT EARTHING
5-7
10-12
6-8
20-22
LT07
8-10
19-21
7-9
20-22
LT08
6-8
5-7
2-4
24-26
LT09
24-26
12-14
25-27
3-5
LT10
29-30
17-18
LT11
29 Jul-2 Aug
10-14
LT12
5-6
23-24
LT13
10-11
20-21
LT14
6-8
2-4
1-3
24-26 19-21
Training Calendar
April 2013 to March 2014
CODE COURSE NAME DAYS
LUCKNOW
LUCKNOW
2013 2013 2013 2013 2013 2013 2013 2013 2013 2014 2014 2014
LT01
26-30
21-25
16-20
17-21
LT02
BEST MAINTENANCE PRACTICES IN LV SWITCHGEAR BREAKER MAINTENANCE WORKSHOP C POWER ACB BREAKER MAINTENANCE WORKSHOP U POWER ACB
9-13
18-22
13-17
10-14
LT03
3-5
2-4
11-13
3-5
LT04
12-14
7-9
2-4
17-19
LT05
16-18
27-29
LT06
POWER DISTRIBUTION IN BUILDINGS INTELLIGENT BUILDING MANAGEMENT SYSTEMS SELECTION & APPLICATION OF MOTORS & DRIVES REACTIVE POWER & HARMONICS MITIGATION INTRODUCTION TO MEDIUM VOLTAGE SWITCHGEAR INDUSTRIAL PROTECTION WITH NUMERICAL RELAYS CONSERVATION & MANAGEMENT OF ELECTRICAL ENERGY REQUIREMENT OF SYSTEM & EQUIPMENT EARTHING
3-5
10-12
LT07
1-3
6-8
LT08
20-22
9-11
18-20
10-12
LT09
13-15
24-26
LT10
17-18
20-21
LT11
19-23
3-7
LT12
LT13
26-27
27-28
LT14
28-30
7-9
2-4
5-7
Training Calendar
April 2013 to March 2014
CODE COURSE NAME DAYS
COONOOR
COONOOR
2013 2013 2013 2013 2013 2013 2013 2013 2013 2014 2014 2014
LT01
5-9
2-6
LT02
BEST MAINTENANCE PRACTICES IN LV SWITCHGEAR BREAKER MAINTENANCE WORKSHOP C POWER ACB BREAKER MAINTENANCE WORKSHOP U POWER ACB
22-26 6-10
2-6
3-7
17-21
LT03
17-19
5-7
19-21
21-23
16-18
10-12
LT04
15-17
8-10
11-13
18-20
6-8
5-7
LT05
6-8
20-22
LT06
POWER DISTRIBUTION IN BUILDINGS INTELLIGENT BUILDING MANAGEMENT SYSTEMS SELECTION & APPLICATION OF MOTORS & DRIVES REACTIVE POWER & HARMONICS MITIGATION INTRODUCTION TO MEDIUM VOLTAGE SWITCHGEAR INDUSTRIAL PROTECTION WITH NUMERICAL RELAYS CONSERVATION & MANAGEMENT OF ELECTRICAL ENERGY REQUIREMENT OF SYSTEM & EQUIPMENT EARTHING
22-24
3-5
7-9
29-31
LT07
12-14
11-13
18-20
3-5
LT08
13-15
12-14
25-27
10-12
LT09
15-17
10-12
16-18
6-8
LT10
9-10
28-29
LT11
1-5
21-25
LT12
10-11
6-7
LT13
8-9
9-10
LT14
3-5
22-24
3-5
29-31 12-14
4-6
28-30
6-8
16-18 20-22
5-7
24-26
Training Calendar
April 2013 to March 2014
CODE COURSE NAME
VADODARA
VADODARA
New
DAYS
2013 2013 2013 2013 2013 2013 2013 2013 2013 2014 2014 2014
LT01
3-7
19-23
25-29
17-21
LT02
BEST MAINTENANCE PRACTICES IN LV SWITCHGEAR BREAKER MAINTENANCE WORKSHOP C POWER ACB BREAKER MAINTENANCE WORKSHOP U POWER ACB
27-31
8-12
7-11
6-10
LT03
24-26
23-25
16-18
3-5
LT04
2-4
10-12
LT05
5-7
10-12
LT06
POWER DISTRIBUTION IN BUILDINGS INTELLIGENT BUILDING MANAGEMENT SYSTEMS SELECTION & APPLICATION OF MOTORS & DRIVES REACTIVE POWER & HARMONICS MITIGATION INTRODUCTION TO MEDIUM VOLTAGE SWITCHGEAR INDUSTRIAL PROTECTION WITH NUMERICAL RELAYS CONSERVATION & MANAGEMENT OF ELECTRICAL ENERGY REQUIREMENT OF SYSTEM & EQUIPMENT EARTHING
19-21
6-8
LT07
22-24
3-5
LT08
17-19
24-26
LT09
15-17
11-13
LT10
26-27
LT11
20-24
11-15
LT12
9-10
LT13
15-16
24-25
LT14
18-20
3-5
8-10
2-4
21-23
16-18 13-15
Registration
How to confirm your booking
1. Email or fax or courier the duly-filled Registration Form to the relevant Switchgear Training Centre. 2. Fees should be paid in advance by way of Demand Draft drawn in favour of 'LARSEN & TOUBRO LIMITED'. The draft should be payable at Pune, Delhi (for Lucknow Centre), Chennai (for Coonoor Centre) or Vadodara, depending on the Centre chosen. 3. Alternatively, fees can be paid in advance by way of NEFT / RTGS to our Bank a/c below: Beneficiary Account Name: Larsen & Toubro Limited Bank Name: State Bank of India Branch: IIT Powai, Mumbai 400076 IFSC code: SBIN0001109 Current Account No: 10725730100 SWIT Code: SBININBB519 4. Registration will be confirmed only after receipt of the course fees.
Please Note:
a) Participants will receive written confirmation of their registration, after which they should plan their journey to the Training Centre selected. b) In case seats are unavailable for the selected course, participants will be offered an opportunity to participate in the next training session for that program. c) All courses are conducted on a 'best effort' basis and are subject to cancellation or postponement due to unforeseen circumstances or lack of sufficient enrolment. L&T reserves all cancellation rights of the training courses and will not be responsible for any consequential losses. d) Please ensure that all registrations are accompanied by the requisite course fees. e) Participants are expected to make their own arrangements for lodging and boarding. f) Participants shall avail all the facilities provided during the training course duration, including travelling at their own risk. L&T will not be responsible for any injury, damage or loss during the course. g) The transfer of fees for a change of participant or course must be confirmed in writing by the Training Centre. h) Course Fees specified are valid until March 31, 2014 only. I) Fees are not refundable under any circumstances.
Exclusions:
Expenses such as travel - including local conveyance up to the fixed pick-up point in the city, lodging, boarding (dinner) and any other expense.
For more information about the Training Calendar and courses please contact the relevant Switchgear Training Centre or Customer Interaction Centre:
Customer Interaction Centre (CIC) BSNL/MTNL (Toll free): 1800 233 5858 Reliance (Toll free): 1800 200 5858 Tel: 022 6774 5858 Fax: 022 6774 5859 E-mail: cic@Lntebg.com
www.Lntebg.com