G. Hanswille Univ.-Prof. Dr.-Ing.

Institute for Steel and Composite Structures University of Wuppertal-Germany

Eurocodes
Background and Applications
Dissemination of information for training 18-20 February 2008, Brussels

Eurocode 4
Composite Columns

Univ. - Prof. Dr.-Ing. Gerhard Hanswille Institute for Steel and Composite Structures University of Wuppertal Germany
1

Contents

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Part 1: Introduction Part 2: General method of design Part 3: Plastic resistance of cross-sections and interaction curve Part 4: Simplified design method Part 5: Special aspects of columns with inner core profiles Part 6: Load introduction and longitudinal shear
2

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Part 1: Introduction

Composite columns

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

concrete encased sections

concrete filled hollow sections partially concrete encased sections


4

Concrete encased sections

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

advantages:

high bearing resistance high fire resistance economical solution with regard to material costs high costs for formwork difficult solutions for connections with beams difficulties in case of later strengthening of the column in special case edge protection is necessary
5

disadvantages:

Partially concrete encased sections

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

advantages:


high bearing resistance, especially in case of welded steel sections no formwork simple solution for joints and load introduction easy solution for later strengthening and additional later joints no edge protection lower fire resistance in comparison with concrete encased sections.

disadvantages:

Concrete filled hollow sections

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

advantages:

high resistance and slender columns advantages in case of biaxial bending no edge protection

disadvantages :

high material costs for profiles difficult casting additional reinforcement is needed for fire resistance

Concrete filled hollow sections with additional inner profiles

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

advantages:


extreme high bearing resistance in combination with slender columns constant cross section for all stories is possible in high rise buildings high fire resistance and no additional reinforcement no edge protection

disadvantages: high material costs difficult casting

Composite columns with hollow sections and additional inner core-profiles

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Commerzbank Frankfurt
9

Design of composite columns according to EN 1994-1-1


Verifications for composite columns Resistance of the member for structural stability General method Simplified method Resistance to local Buckling

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Introduction of loads

Longitudinal shear outside the areas of load introduction

10

Methods of verification in accordance with EN 1994-1-1


Methods of verification general method: any type of cross-section and any combination of materials

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

simplified method: double-symmetric cross-section uniform cross-section over the member length limited steel contribution factor related Slenderness smaller than 2,0 limited reinforcement ratio limitation of b/t-values
11

Resistance to lokal buckling


bc b

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

concrete encased cross-sections


Verification is not necessary where
40 mm cz b/6

cy

cy cz h cz hc

y
concrete filled hollow section t

z
d t d max = 52 t d

d max = 90 2 t
partially encased I sections

fyk,o fyk

d max = 44 t
b

fyk,o = 235 N/mm2

t
12

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Part 2: General design method

13

General method

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Design for structural stability shall take account of

geometrical imperfection
wo = L 1000

wo

second-order effects including residual stresses, geometrical imperfections, local instability, cracking of concrete, creep and shrinkage of concrete yielding of structural steel and of reinforcement.

E
+ residual stresses due to rolling or welding

The design shall ensure that instability does not occur for the most unfavourable combination of actions at the ultimate limit state and that the resistance of individual cross-sections subjected to bending, longitudinal force and shear is not exceeded. Second-order effects shall be considered in any direction in which failure might occur, if they affect the structural stability significantly. Internal forces shall be determined by elasto-plastic analysis. Plane sections may be assumed to remain plane. Full composite action up to failure may be assumed between the steel and concrete components of the member. The tensile strength of concrete shall be neglected. The influence of tension stiffening of concrete between cracks on the flexural stiffness may be taken into account.

14

General method of design

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

F e 0,4 fc

fcm concrete

Ecm fct

w
cracked concrete plastic zones in structural steel fy + stresses in structural steel section fs fc + stresses in concrete and reinforcement fu fy ftm fsm

c1

c1u

reinforcement Es -

s
Ev

- Ea

structural steel

a
15

Typical load-deformation behaviour of composite columns in tests


F [kN] 1600 e=100mm e F

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

A concrete encased section and


bending about the strong axis: Failure due to exceeding the ultimate strain in concrete, buckling of longitudinal reinforcement and spalling of concrete.

A
1200 e=160mm

w B B
F

800

concrete encased section and bending about the weak axis : Failure due to exceeding the ultimate strain in concrete.

400

e=130mm

20

40

60

80

100

Deflection w [mm]

concrete filled hollow section: cross-section with high ductility and rotation capacity. Fracture of the steel profile in the tension zone at high deformations and local buckling in the compression zone of the structural steel section.
16

General Method Safety concept based on DIN 18800-5 (2004) and German national Annex for EN 1994-1-1
c
0,4 fc fcm Ecm ftm fsm Es

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

concrete c1u c

fu fy

a
Ev Ea

fct

c1

reinforcement s

v R =

structural steel a Rpl,m Rpl,d


Residual stresses ++ -

u : amplification factor for ultimate system capacity


Verification u R

E
Rpl,m

u Ed Ed

geometrical Imperfection

NEd
Ed

Rpl,d
wo=L/1000 wo + -

M MEd

wu

17

Composite columns for the central station in Berlin

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

t=25mm

800 550

S235

buckling curve a

S355

1,0

buckling curve b
buckling curve c

0,5
-

buckling curve d
Residual stresses

0,5

1,0

1,5

2,0

18

1200

700

t=50mm

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Part IV-3: Plastic resistance of cross-sections and interaction curve


19

Resistance of cross-sections
fyd y z
Design value of the plastic resistance to compressive forces: Characteristic value of the plastic resistance to compressive forces: Design strength: Increase of concrete strength due to better curing conditions in case of concrete filled hollow sections:

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

fcd Npla,Rd Nplc,Rd

fsd Npls,Rd

Npl,Rd = Npla ,Rd + Nplc ,Rd + Npls,Rd Npl,Rd = A a fyd + A c fcd + A s fsd

Npl,Rk = A a fyk + A s fsk + A c fck fyd = fyk a fsd = fsk s fcd = fck c

= 1,0

= 0,85

20

Confinement effects in case of concrete filled tubes


structural steel c,r
2 2 2 2 a ,Rd + a, a,Rd a, = fyd

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

fck ,c fck
2.0 1.5 1.25 1.0 0.5 1=1,00 2= 5,0

concrete
1=1,125 2= 2,5

fck,c

a,Rd = a fyd

a fyd

c,r

c,r

fck ,c = 1 fck + 2 c ,r
0.05 0.10

a
t d

a
d-2t

c ,r fck

0 0

0.15 0.20 0.25 0.30 0.35

For concrete stresses c>o,8 fck the Poissons ratio of concrete is higher than the Poissons ratio of structural steel. The confinement of the circular tube causes radial compressive stresses c,r. This leads to an increased strength and higher ultimate strains of the concrete. In addition the radial stresses cause friction in the interface between the steel tube and the concrete and therefore to an increase of the longitudinal shear resistance.
21

Confinement effect acc. to Eurocode 4-1-1

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Design value of the plastic resistance to compressive forces taking into account the confinement effect: t fyk Npl,Rd = a fyd A a + A c fcd 1 + c d fck Basic values for stocky columns centrically loaded: influence of slenderness for
ao = 0,25 co = 4,9

t y d
MEd NEd

z MEd

e=

NEd

a, = ao + 0,5 K 1 ,0 c, = co 18,5 K (1 0,92 K


a = a, + 10 (1 ao ) e d

0,5

) 0
fc fy

influence of load eccentricity :

e c = c, 1 10 d

e/d>0,1 : a=1,0 and c=0

22

Plastic resistance to combined bending and compression


N

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Npl,Rd NEd

interaction curve

The resistance of a cross-section to combined compression and bending and the corresponding interaction curve may be calculated assuming rectangular stress blocks. The tensile strength of the concrete should be neglected. The influence of transverse shear forces on the resistance to bending and normal force should be considered when determining the interaction curve, if the shear force Va,Ed on the steel section exceeds 50% of the design shear resistance Vpl,a,Rd of the steel section. The influence of the transverse shear on the resistance in combined bending and compression should be taken into account by a reduced design steel strength (1 - ) fyd in the shear area Av.
Va,Ed 0,5 Vpla,Rd = 0 Va,Ed > 0,5 Vpla,Rd 2 V = a,Ed 1 Vpla,Rd
2

Mpl,N,Rd= Mpl,Rd

Mpl,Rd fyd 0,85 f cd zpl y z +


(1-) fyd

fsd
VEd

NEd

Mpl,N Rd

23

Influence of vertical shear

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Va,Ed

Vc,Ed

fyd fyd + fsd

zpl

0,85fcd VEd fsd

MRd NEd

The shear force Va,Ed should not exceed the resistance to shear of the steel section. The resistance to shear Vc,Ed of the reinforced concrete part should be verified in accordance with EN 1992-1-1, 6.2. Unless a more accurate analysis is used, VEd may be distributed into Va,Ed acting on the structural steel and Vc,Ed acting on the reinforced concrete section by :
Mpla,Rd Ma MRd Mpl,Rd Vc,Ed = VEd Va,Ed Va,Ed = VEd

MRd= Ma + Mc+s
zpl fyd

NEd = Na +Nc+s
Ma fsd fsd Mc,+s Nc+s

Na

Verification for vertical shear:


Va,Ed Vpla,Rd Vc,Ed Vc,Rd

Mpl,a,Rd Mpl,Rd

is the plastic resistance moment of the steel section. is the plastic resistance moment of the composite section.
24

Determination of the resistance to normal forces and bending (example)


b tf fyd Naf Naw,c y hw zpl zaw,t (1-) fyd 0,85fcd -

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Ns Nc zc fsd zs zs Ns

VEd

As tw

Mpl,N,Rd NEd

- zaw,c Naw,t Naf

Position of the plastic neutral axis:


Nc + Naw,c Naw,t = NEd

Ni

= NEd
zpl = NEd + h w t w (1 ) fyd (b t w ) 0,85 fcd + 2 t w (1 ) fyd

(b t w ) zpl 0,85 fcd + t w zpl (1 ) fyd t w (h w zpl ) (1 ) fyd = NEd

Naw,c = zpl t w (1 ) fyd Naw,t = (h w zpl ) t w (1 ) fyd Naf = b t f fyd Nc = (b t w ) zpl 0,85 fcd Ns = 2A s fsd
25

Plastic resistance to bending Mpl,N,Rd in case of the simultaneously acting compression force NEd and the vertical shear VEd:
Mpl,N,Rd = Nc zc + Naw,c zaw,c + Naw,t zaw,t + Naf (hw + t f ) + 2 Ns zs

Simplified determination of the interaction curve


0,85fcd A
Npl,Rd

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

fsd -

fyd -

Npl,Rd

A C

0,85fcd fsd
zpl

Npm,Rd Npm,Rd 2

B D B
Mpl,Rd Mmax,Rd

hn

fyd -

MB,Rd = Mpl,Rd

+ fyd fyd MC,Rd = Mpl,Rd

0,85fcd
M

fsd

zpl

2hn

fyd
As a simplification, the interaction curve may be replaced by a polygonal diagram given by the points A to D.

+ Npm,Rd

0,85fcd D
zpl

fsd

fyd MD,Rd = Mmax,Rd - fyd +


0,5 Npm,Rd
26

Resistance at points A and D

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Point A

Nplc,Rd

Npls,Rd

Npla,Rd
Npl,Rd = Npla ,Rd + Nplc ,Rd + Npls ,Rd M A ,Rd = 0

Point D bc hc
0,85 fcd

fsd fyd Mpls,Rd zsi

b tf tw h h

fcd
0,5 Mplc,Rd

Mpla,Rd fyd +
ND,Rd = 0,5 Nplc ,Rd MD,Rd = Mmax, Rd

zsi

fsd

Mmax, Rd = Mpla ,Rd + Mpls ,Rd + 1 2 Mplc ,Rd


Wpl,a plastic section modulus of the structural steel section Wpl,s plastic section modulus of the crosssection of reinforcement Wpl,c plastic section modulus of the concrete section

(h 2t )2 t f w + b t (h t ) f Mpla,Rd = Wpl,a f yd = f f yd 4

Mpls,Rd = Wpl,s fsd = [ A si z si ] f ys b h2 c c Mplc,Rd = Wpl,c 0,85 fcd = Wpl,a Wpl,s 0,85 fcd 4

27

Bending resistance at Point B (Mpl,Rd )

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

- 0,85fcd

0,85fcd + hn

fsd

+ + +
-

+
2 fsd hn

+
+
+ 2fyd hn

At point B is no resistance to 0,85 compression forces. Therefore fcd the resistance to compression forces at point D results from the additional cross-section zones in compression. With ND,Rd the + depth hn and the position of the plastic neutral axis at point B can + be determined. With the plastic fsd bending moment M n,Rd resulting from the stress blocks within the depth hn the plastic resistance + moment Mpl,Rd at point B can be calculated by:

fyd

fyd + Mpln,Rd

Mpl,Rd = MD,Rd Mp ln,Rd


zpl hn

Point D
ND,Rd

zpl
MD,Rd

hn ND,Rd

Mpl,Rd

Point B
28

Plastic resistance moment at Point C

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

0,85 fcd

0,85fcd

2hn

0,85fcd

The bending resistance at point C is the same as the bending resistance at point B.

fsd

+
2 fsd

+ +
2hn

+
fsd +

MC,Rd= Mpl,Rd
The normal force results from the stress blocks in the zone 2hn.

fyd -

+
+

+
2fyd 2hn

+
fyd +

NC,Rd = 2 ND,Rd = Ncpl,Rd = Npm,Rd

Point B
zpl hn Mpl,Rd

Point C

2hn NC,Rd

Mc,Rd 2hn Nc,Rd


29

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Part 4: Simplified design method

30

Simplified Method

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Methods of verification acc. to the simplified method Design based on the European buckling curves Axial compression Design based on second order analysis with equivalent geometrical bow imperfections
K

wo

Resistance of member in combined compression and bending

Design based on second order analysis with equivalent geometrical bow imperfections

wo

31

Scope of the simplified method


double symmetrical cross-section

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

uniform cross-sections over the member length with rolled, cold-formed or welded steel sections steel contribution ratio 0,2 0,9 A a fyd Npl,Rd

relative slenderness Npl,Rk = 2,0 Ncr longitudinal reinforcement ratio

A 0,3 % s 6,0 % s = s Ac
the ratio of the depth to the width of the composite crosssection should be within the limits 0,2 and 5,0
32

Effects of creep of concrete

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Load F [kN]
Fu = 2022 kN 2000 Fu = 1697 kN 1500 long term test

e F
short term test wt wo L = 800 cm The horizontal deflection and the second order bending moments increase under permanent loads due to creep of concrete. This leads to a reduction of the ultimate load.

1000 Fv = 534 kN

30 cm The effects of creep of concrete are taken into account in design by a reduced flexural stiffness of the composite cross-section. 30 cm e=3 cm 80 100
33

500

permanent load
0 20 40 60

deflection w [mm]

Effects of creep on the flexural stiffness

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

The effects of creep of concrete are taken into account by an effective modulus of elasticity of concrete
Ec,eff = 1+ Ecm NG,Ed NEd ( t, t o )

Ecm NEd NG,Ed (t,to)

Secant modulus of concrete total design normal force part of the total normal force that is permanent creep coefficient as a function of the time at loading to, the time t considered and the notional size of the cross-section

notional size of the cross-section for the determination of the creep coefficient (t,to)
ho = 2 Ac U

effective perimeter U of the crosssection b b h


U = 2 (b + h)

In case of concrete filled hollow section the drying of the concrete is significantly reduced by the steel section. A good estimation of the creep coefficient can be achieved, if 25% of that creep coefficient is used, which results from a cross-section, where the notional size ho is determined neglecting the steel hollow section.

h
U 2 h + 0,5b

t,eff = 0,25 (t,to)


34

Verification for axial compression with the European buckling curves


cross-section
buckling about strong axis = 0,85 buckling about weak axis = 0,85
buckling curve

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

=
1,0

NRd Npl,Rd

0,8
=

Npl,Rk Ncr

2,0

0,6 c 0,4 0,2 0,2 0,6 1,0

b c
1,4

,00 s 3% = 1
3% < s 6 % = 1,00

=
1,8

Npl,k Ncr

Verification:
b

NEd 1,0 NRd

= 1,00

Design value of resistance

NRd = Npl,Rd

= 0,85

Npl,Rd = A a fyd + A s fsd + A c fcd


35

Relative slenderness

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

fcd =

fck c

relative slenderness: = Npl,Rk Ncr 2,0

= 0,85

characteristic value of the plastic resistance to compressive forces Npl,Rk = A a fyk + A c fck + A s fsk fcd = fck c elastic critical normal force
Ncr = 2 (EJ)eff ( L )
2

= 1,00

- buckling length factor

effective flexural stiffness

(EJ)eff = (EaJa + K e Ec,eff Jc + EsJs )

Ke=0,6

36

Verification for combined compression and bending


Npl,Rd
NEd N

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

wo equivalent geometrical bow imperfection


wo

Verification
max MEd MRd = M Mpl,Rd

M= 0,9 for S235 and S355 M= 0,8 for S420 and S460 bending moments taking into account second order effects:
max MEd = NEd w o 2 (E J)eff ,II 2L2 1 N 1 Ed Ncr

M Mpl,Rd
Mpl,N,Rd

MRd
fyd (1-) fyd +

Mpl,Rd Mpl,N Rd NEd

0,85fcd -

Ncr =

The factor M takes into account the difference between the full plastic and the elasto-plastic resistance of the cross-section resulting from strain limitations for concrete.

fsd VEd

Effective flexural stiffness


(EI)eff ,II = K o (EaJa + K e Ec,eff Jc + Es Js ) with K e,II = 0,5 K o = 0,9
37

Equivalent initial bow imperfections

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Buckling curve

b
3% < s 6%

s 3%

Member imperfection wo= L/300 wo= L/200 wo= L/150


38

Imperfections for global analysis of frames

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

sway imperfection
NEd,1 NEd,2

Global initial sway imperfection acc. to EN 1993-1-1:

= o m h
o h basic value with o = 1/200 reduction factor for the height h in [m]

h =

2 2 h 1,0 but 3 h
reduction factor for the number of columns in a row

equivalent forces
NEd,1 NEd,1 NEd,2 NEd,2

m =
m

1 0,5 1+ m

NEd,1

NEd,2

is the number of columns in a row including only those columns which carry a vertical load NEd not less than 50% of the average value of the column in a vertical plane considered.
39

Frames sensitive against second order effects

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

NEd,1

imperfections
Npl,Rk NEd,2

NEd,2

> 0,5

L1

2 w0

L2

Within a global analysis, member imperfections in composite compression members may be neglected where first-order analysis may be used. Where second-order analysis should be used, member imperfections may be neglected within the global analysis if:

0,5

Npl,Rk NEd,1

0,5

Npl,Rk NEd,i

NEd,1 NEd,2 NEd,1 1 NEd,1 1 NEd,2 2

w 4 o NEd,2 L2 q=8 wo L2 2 NEd,2

Npl,Rk Ncr

equivalent forces
NEd,2 2

Ncr =

2 (EJ)eff L2 i

w 4 o NEd,2 L2

(EJ)eff = (EaJa + 0,6 Ec,eff Jc + EsJs )


40

Second order analysis

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Bending moments including second order effects:

r MR r MR

r sin (1 ) + sin cos (0,5 ) 1 M() = MR + Mo sin cos ( / 2)


sin (0,5 ) M r cos (1 ) + cos Vz ()= R 1 + Mo L sin cos ( / 2)

EJ

wo

L M

Mmax

Mo = (q L2 + 8 N w o )

1 2

= L

NEd (E J)eff ,II

dM = 0 Maximum bending moment at the point M: d 1+ c 2 Mmax = [0,5 M ( 1 + r ) + Mo ] M0 cos(0,5 )

MR MR

c=

M (r 1) 1 M (1 + r ) + 2 Mo tan (0,5 )

M = 0,5 +

arctan c
41

Simplified calculation of second order effects

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

k
4,0

r=1,0

r MR N r MR

Exact solution:
1+ c 2 Mmax = 0,5 MR ( 1 + r ) cos(0,5 ) r 1 1 c= 1 + r tan (0,5 )
arctan c M = 0,5 +

r=0,5

3,0

r=0 r= - 0,5

EJ L

M Mmax MR

= L

NEd (E J)eff ,II

2,0

simplified solution:
Mmax = MR 1 NEd Ncr = 0,66 + 0,44 r 0,44

1,0 exact method simplified method 0,25 0,50 0,75 1,00

MR
N Ncr

k=

42

Background of the member imperfections

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

NRd =L (EJ)eff ,II

NEd=NRd

Bending moment based on second order analysis:

M= NRd Mpl,Rd
wo

8 w o (EJ)eff ,II 1 1 L2 cos( / 2)

Resistance to axial compression based on the European buckling curves:

NRd = Npl,Rd MRd Mpl,Rd

Bending resistance:

MRd = M Mpl,Rd
Determination of the equivalent bow imperfection:
wo = M d Mpl,Rd L2 1 8 (EJ)eff ,II 1 1 cos ( / 2)
43

The initial bow imperfections were recalculated from the resistance to compression calculated with the European buckling curves.

Geometrical bow imperfections comparison with European buckling curves for axial compression
j 500 1,2 400 1 2 1,1 1,0 0,9 0,8 2,0 1 2 3

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

NRd ( ) NRd ( w o )

1 2 3

C20/S235 C40/S355 C60/S355

300

200

L j= wo
1,0

wo= l/300

0,4

0,8

1,2

1,6

2,0

The initial bow imperfection is a function of the related slenderness and the resistance of cross-sections. In Eurocode 4 constant values for w0 are used.

The use of constant values for wo leads to maximum differences of 5% in comparison with the calculation based on the European buckling curves.
44

Comparison of the simplified method with nonlinear calculations for combined compression and bending
N Npl,Rd
1,0
Plastic cross-section resistance

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Resistance as a function of the related slenderness

k = 0,50 k = 1,00
Npl,Rk Ncr

0,8 0,6 0,4 0,2

k = 1,50 k = 2,00

general method

simplified method

M
0,2 0,4 0,6 0,8 1,0

Mpl,Rd
45

Resistance to combined compression and biaxial bending


N Npl,Rd
Interaction Mz, N
z,Ed y,Ed

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

NEd Npl,Rd
Interaction My, N

The resistance is given by a threedimensional interaction relation. For simplification a linear interaction between the points A and B is used.
My,Rd (NEd ) = dy Mpl,y,Rd Mz,Rd (NEd ) = dz Mpl,y,Rd My,Ed = y,Ed My,Rd Mz,Ed = z,Ed My,Rd

dz A

dy

Interaction My, Mz, NEd Approximation:


dy +

y,Ed

z,Ed 1,0 dz

approximation for the interaction curve:


y,Ed dy + z,Ed 1,0 dz
+ Mz,Ed 1,0 dz Mpl,z,Rd
46

My Mz Mpl,z,Rd
Interaction My, Mz

Mpl,y,Rd

My,Ed dy Mpl,y,Rd

Verification in case of compression an biaxial bending


For both axis a separate verification is necessary. My,Ed dy Mpl,y,Rd M Mz,Ed M dz Mpl,y,Rd
N Npl,Rd

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

NEd Npl,Rd

dy

My,Rd

Verification for the interaction of biaxial bending. My,Ed dy Mpl,y,Rd + Mz,Ed 1,0 dz Mpl,y,Rd
N Npl,Rd

Mpl,y,Rd

Imperfections should be considered only in the plane in which failure is expected to occur. If it is not evident which plane is the most critical, checks should be made for both planes.

NEd Npl,Rd

dz

Mz,Rd Mpl,z,Rd

M= 0,9 for S235 and S355 M= 0,8 for S420 and S460
47

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Part 5: Special aspects of columns with inner core profiles

48

Composite columns General Method

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Commerzbank Frankfurt

Millennium Tower Vienna

New railway station in Berlin (Lehrter Bahnhof) Highlight Center Munich


49

Composite columns with concrete filled tubes and steel cores special effects
Resistance based on stress blocks (plastic resistance) tube fy core fy concrete fc M N Non linear resistance with strain limitation for concrete strains fy fy fc M N

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

MRd = Mpl,Rd

Cross-sections with massive inner cores have a very high plastic shape factor and the cores can have very high residual stresses. Therefore these columns can not be design with the simplified method according to EN 1944-1-1.
ED

r
50

Residual stresses and distribution of the yield strength

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

ED
300 250 200 150 100 50

[N/mm2]

distribution of yield strenght fyk


fy(r) fyk characteristic value of the yield strenght

U = dk
2 A = dk /4
rk dk

fy (r ) fyk

r = 0,95 + 0,1 r k

U/A [1/m] 10 20 30 40 100 50 dK [mm] 400 200 130 80 dK d residual stresses:


ED
2r2 E (r ) = ED 1 2 rK

r, rk
51

General method Finite Element Model

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

load introduction

stresses in the tube

initial bow imperfection

cross-section

stresses in concrete

52

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Part 6: Load introduction and longitudinal shear

53

Load introduction over the steel section

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

NEd

load introduction by headed studs within the load introduction length LE


2d LE L / 3

d L

minimum transverse dimension of the cross-section member length of the column

PD

LE < 2,0 d

sectional forces of the cross-section : Nc,Ed Na,Ed Aa Ns,Ed As Ac required number of studs n resulting from the sectional forces NEd,c+ NEd,s:
Npl,a VL,Ed = Nc,Ed + Ns,Ed = NEd 1 N pl , Rd VL,Rd = n PRd Na,Ed = NEd Npl,a Npl,Rd Ns,Ed = NEd Npl,s Npl,Rd Nc,Ed = NEd Npl,c Npl,Rd

PRd design resistance of studs


54

Load introduction for combined comression and bending


sectional forces due to NEd und MEd

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

sectional forces based on plastic theory

MEd

NEd

MRd = Ma,Rd + Mc + s,Rd zpl fyd Ma;Rd + Na,Rd fsd

NRd = Na,Rd + Nc + s,Rd 0,85fcd Mc,+s,Rd

MRd

N Npl,Rd
1,0

+
fsd

=
Nc+s,Rd

NRd

Na,Ed Nc,Ed +Ns,Ed Mc,Ed +Ms,Ed

Ma,Ed

NRd Npl,Rd NEd Npl,Rd


Ed Rd

Ed Na,Ed Ma,Ed Nc + s,Ed Mc + s,Ed = = = = Rd Na,Rd Ma,Rd Nc + s,Rd Mc + s,Rd


M N Rd = Ed + Ed Mpl,Rd Npl,Rd
2 2 2

M Mpl,Rd

MEd MRd 1,0 Mpl,Rd Mpl,Rd

M N Ed = Rd + Rd Mpl,Rd Npl,Rd

55

Load introduction Example

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

sectional forces based on stress blocks: fyd Ma;Rd Na,Rd + fsd fcd -Ns,i -Nc Zs zpl zc
Zs

Nc + s,Rd = Nc + Nsi

Mc,+s,Rd -Nc+s,Rd

Mc + s,Rd = Nc zc + Nsi z si

fsd Ns,i shear forces of studs based on plastic theory


2

shear forces of studs based on elastic theory


N Mc + s,Ed Mc + s,Ed + c s , Ed xi + zi + 2 2 n r ri i
2

max PEd =

N M max PEd = c + s,Ed + c + s,Ed n eh 0,5 n

PEd(N) Ped,v

xi

zi ri

Ped,h P (M) Ed Nc+s,Ed Mc+s,Ed

n number of studs within the load introduction length Nc+s,Ed

eh
Mc+s,Ed
56

Shear resistance of stud connectors welded to the web of partially encased I-Sections

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

PRd Dc PRd / 2 PRd / 2


Where stud connectors are attached to the web of a fully or partially concrete encased steel I-section or a similar section, account may be taken of the frictional forces that develop from the prevention of lateral expansion of the concrete by the adjacent steel flanges. This resistance may be added to the calculated resistance of the shear connectors. The additional resistance may be assumed to be on each flange and each horizontal row of studs, where is the relevant coefficient of friction that may be assumed. For steel sections without painting, may be taken as 0,5. PRd is the resistance of a single stud.
57

VL,Rd = PRd + VLR,Rd

VLR,Rd = PRd

Shear resistance of stud connectors welded to the web of partially encased I-Sections
PRd PRd PRd PRd PRd PRd

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

VLR,Rd/2

< 300

< 400

< 600

PRd,1 = 0,29 d2

fck Ecm

VL,Rd = n PRd + VLR,Rd

VLR,Rd = PRd

PRd= min

d2 1 PRd,2 = 0,8 fu 4 v

1 v

In absence of better information from tests, the clear distance between the flanges should not exceed the values given above.
58

Shear resistance of stud connectors welded to the web of partially encased I-sections
F F F F

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

F [kN]
3500 3000 2500 2000 1500

test series S1 test S3/3

test series S2

1000

test S1/3
500

w [mm]
0 0 2 4 6 8 10 12 14 16
59

Load introduction longitudinal shear forces in concrete


NEd NEd

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Longitudinal shear force in section I-I:

VL,Ed = NEd

Npl,a A c1 0,85 fcd + A s1 fsd 1 N pl , Rd A c 0,85 fcd + A s fsd

Dc LE

Dc Zs Zs Zs D c
Longitudinal shear resistance of concrete struts:

VL,Rd,max = 4

c y 0,85 fcd cot + tan

LE

=45o

I I cy bc cy I

= 0,6 (1 ( fck / 250 )) with fck in N / mm 2


longitudinal shear resistance of the stirrups:

VL,Rd,s = 4

As fyd cot LE sw

not directly connected concrete area As1

sw- spacing of stirrups


As- cross-section area of the stirrups
60

Load introduction longitudinal shear forces in concrete test results


F [kN]
2000

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Fu = 1608 kN
1500

1000

w
500

test I/1

w [mm]
0 2 4 6 8 10 12 14
61

Load introduction Examples (Airport Hannover)

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Load introduction with gusset plates

62

Load introduction with partially loaded end plates

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Load introduction with partially loaded end plates


63

Load introduction with distance plates for columns with inner steel cores

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

distance plates

Post Tower Bonn

64

Composite columns with hollow sections Load introduction stiffeners and end plates

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

gusset plate

distance plates

Stiffener

Distance plate

65

Mechanical model

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

PcR,m = fc A1

Ac A1

t fy 1+ cL d f c

c
A1

Effect of partially loaded area

Effect of confinement by the tube

Ac

c,r c,L = 3,5 a,t c,L = 4,9 a,t


66

Typical load-deformation curves

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

P [MN] 2.5 2.0 1.5 1.0

Pu

series SXIII

Pu,stat

P
P [MN]

0.5

5.0

Pu Pu,stat

series SV

[mm]
0 5 10 15 20 25 30 35

4.0 3.0 2.0 1.0

[mm]
15 20
67

10

Test evaluation according to EN 1990


re [MN]

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

10,0 8,0 6,0 4,0 2,0


41 tests Vr= 0.14

Pc,Rm

Pc,Rk = 0.78 Pc,Rm Pc,Rd = 0.66 Pc,Rm 2,0 4,0 6,0 8,0
Ac A1

a,x

c
A1

rt [MN]

10,0

Ac

t fy PcR,m = fc A 1 1+ cL d f c

c,r a,y a,y


68

Load distribution by end plates

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

~1d

F [kN] Fu
6000

ts
4000
Fu = 6047 kN Fu,stat = 4750 kN u = 7.5 mm

tp

c
bc
[mm]

2000

bc = t s + 5 t p
69

5,0

10,0

15,0

Design rules according to EN 1994-1-1

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

c,Rd = fcd

t fyk 1+ cL d f ck

ts
A c A c fcd fyd A1 A1

Load distribution 1:2,5

tp

A1

fck t d fyk A1 Ac c,L

concrete cylinder strength Ac 20 wall thickness of the tube A1 diameter of the tube yield strength of structural steel loaded area cross section area of the concrete confinement factor c,L = 4,9 (tube) c,L = 3,5 (square hollow sections)

c,Rd
bc
bc = t s + 5 t p

bc

70

Verification outside the areas of load introduction


F A
pure bond (adhesion)

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

B
mechanical interlock

Outside the area of load introduction, longitudinal shear at the interface between concrete and steel should be verified where it is caused by transverse loads and / or end moments. Shear connectors should be provided, based on the distribution of the design value of longitudinal shear, where this exceeds the design shear strength Rd. In absence of a more accurate method, elastic analysis, considering long term effects and cracking of concrete may be used to determine the longitudinal shear at the interface.
71

C
friction

Design shear strength Rd


bc b
Rd,o= 0,30 N/mm2

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

cy

cy cz h cz hc

concrete encased sections

Rd = Rd,o c c c = 1 + 0,02 c z 1 z,min 2,5 cz cz- nominal concrete cover [mm] cz,min=40mm (minimum value)

y z concrete filled tubes Rd= 0,55 N/mm2

flanges of partially encased I-sections Rd= 0,20 N/mm2

concrete filled rectangular hollow sections Rd= 0,40 N/mm2

webs of partially encased I-sections Rd= 0,0 N/mm2


72

G. Hanswille Univ.-Prof. Dr.-Ing. Institute for Steel and Composite Structures University of Wuppertal-Germany

Thank you very much for your kind attention


73