Professional Documents
Culture Documents
Water
Water
100 50 R16 U BARS AS LIFTING HOLDS F2 600 SQUARE F 1 R16 U BARS AS LIFTING HOLDS 30 F2
30
200
200
200
R6-100 LINKS
60
65
50
50
650 SQUARE
650 SQUARE
75
50
650 SQUARE
25
25
150
0 1050
150
0 1200 OR 1350
25
150
0 1500 OR 1800
SECTION A-A
0 0 7
7 0 0
7 0 0
T10 - 100 (T&B) MAIN BARS (TYPE 1)
T10 - 100 (T) T10 - 75 (T) T12 - 75 (B) MAIN BARS (TYPE 2) T12 - 100 (B) MAIN BARS (TYPE 2) T10 - 100 (T) T12 - 100 (B) MAIN BARS (TYPE 2)
T16 (T&B) TRIMMER BARS (TYPE 2) T16 (T&B) TRIMMER BARS (TYPE 2) T16 (T&B) CIRCUMFERENTIAL BARS T16 (T&B) CIRCUMFERENTIAL BARS R10 -75 R10 -100
SHEAR LINKS
T16 (T&B) DIAGONAL BARS T16 (T&B) R6 - 100 DIAGONAL BARS SHEAR LINKS DIAMETER OF CHAMBER RING T16 (T&B) DIAGONAL BARS 1200 120 100 F1 F2
OVERHANG
PLAN
CHAMBER RING THE COARSE AGGREGATE FOR GRADE 30 CONCRETE SHOULD BE REINFORCEMENT GRADED FROM 5mm TO 20mm. R
300
LENGTH
T/2 DC
SCALES
1 : 10
R6 - 100
SHEAR LINKS
SHEAR LINKS
1050
120
100
PLAN
PLAN
1350
125
100
1500
125
100
1800
130
100
NOTES :
UNLESS OTHERWISE STATED, ALL CONCRETE TO BE GRADE 30 AND ALL COVER TO STEEL REINFORCEMENT TO BE 40mm.
DIAMETER DC
THICKNESS T
REBATE LENGTH R
1050
100
85
110
90
110
90
110
100
1800
135
100