600 / 1000v Stranded Copper Conductors PVC Insulated With Steel Wire Amour and PVC Sheathed Overall. (BS 6346: 1997)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Gland Selection Table:

600 / 1000v stranded copper conductors pvc insulated with steel wire amour and PVC sheathed overall. (BS 6346 : 1997)
Cable Size
Conductor

Numbers of Cores

Nom.
Area
(mm2)

Neutral

31/2

10

12

19

27

37

48

1.5

16

16

20S

20S

20S

20

20

25

25

32

32

2.5

20S

20S

20S

20S

20

25

25

25

32

32

40

20S

20

20

20

25

25

25

32

40

20

20

20

10

25

25

25

16

25

25

25

25

16

25

32

32

32

35

16

32

32

32

40

50

25

25

32

32

32

40

70

35

25

32

40

40

40

95

50

25

40

40

50S

50S

120

70

32

40

50S

50

50

150

70

32

50S

50

50

63S

185

95

32

50

50

63S

63

240

120

40

50

63S

63

75S

300

150

40

63S

63

75S

75

300

185

40

63

63

75

75

400

185

50S

63

75S

75

75

500

50

630

50

800

63S

1000

63

600 / 1000v stranded copper conductors xlpe/swa/pvc cable and PVC sheathed overall. (BS 5467 : 1989)
Cable Size
Conductor

Numbers of Cores

Nom.
Area
(mm2)

Neutral

31/2

10

12

19

27

37

48

1.5

20S

20S

20S

20S

20S

20

25

25

32

32

32

2.5

20S

20S

20S

20S

20

25

25

32

32

40

40

20S

20S

20

20

25

25

25

32

40

40

50S

20

20

20

10

20

25

25

16

25

25

25

25

16

25

32

32

32

35

16

32

32

32

32

50

25

25

25

32

32

32

70

35

25

32

32

40

40

95

50

25

32

40

50S

50S

120

70

32

40

40

50

50

150

70

32

40

50S

50

50

185

95

32

50S

50

63S

63S

240

120

40

50

63S

63

63

300

150

40

63S

63

75S

75S

300

185

40

63S

63

75S

75

400

185

50S

63S

75S

75

75

500

50

630

50

800

63S

1000

63

Single Compression Heavy Duty as per IS12943


Cable Overload Diameter (mm)
From

To

Nipple Thread in (mm)

9.0

12.0

16 x 1.5

12.0

15.0

16 x 1.5

12.0

15.0

20 x 1.5

15.0

18.0

20 x 1.5

16.0

20.0

25 x 1.5

20.0

24.0

25 x 1.5

24.0

28.0

32 x 1.5

28.0

32.0

40 x 1.5

33.0

37.0

40 x 1.5

37.5

42.0

50 x 1.5

43.0

48.0

50 x 1.5

49.0

54.0

63 x 1.5

55.0

60.0

63 x 1.5

61.0

66.0

75 x 1.5

67.0

72.0

75 x 1.5

73.0

78.0

82 x 1.5

79.0

84.0

90 x 1.5

84.5

92.0

100 x 1.5

93.0

100.0

110 x 1.5

101.0

115.0

125 x 1.5

ARMOUR CABLE (Single Compression Medium Duty)


Cable Overload Diameter (mm)
From

To

Nipple Thread in (mm)

6.0

9.0

3/8

9.0

12.0

1/2

12.0

14.0

5/8

14.0

16.0

3/4

16.0

18.0

7/8

18.0

21.5

21.5

26.0

1 1/8

26.0

31.0

1 1/4

31.0

34.0

1 3/8

34.0

38.0

1 1/2

38.0

42.0

1 3/4

42.0

48.0

48.0

54.0

2 1/4

54.0

60.0

2 1/2

60.0

66.0

2 3/4

66.0

72.0

72.0

78.0

3 1/4

78.0

84.0

3 1/2

84.0

92.0

UN-ARMOUR CABLE (Double Compression Medium Duty)


Cable Overload Diameter (mm)
From

To

Nipple Thread Size

5.0

11.0

3/4

11.0

14.0

3/4

14.1

18.0

18.1

20.0

20.1

23.0

28 mm

23.1

26.0

1 1/4

26.1

30.0

1 1/2

30.1

33.0

1 1/2

33.1

36.0

42 mm

36.1

41.0

41.1

44.0

44.1

52.0

2 1/2

52.1

55.0

2 1/2

55.1

60.0

70 mm

60.1

66.0

66.1

75.0

3 1/4

75.0

80.0

3 1/2

81.0

90.0

90.0

100.0

4 1/2

ARMOUR CABLE (Double Compression Medium Duty)


Cable Overload Diameter (mm)
From

To

Nipple Thread Size

6.0

12.0

3/4

12.0

16.5

3/4

16.5

18.5

3/4

16.5

18.5

18.5

20.0

18.5

20.0

3/4

20.0

23.0

23.0

26.0

23.0

26.0

1 1/4

26.0

30.0

1 1/4

26.0

30.0

1 1/2

30.0

33.0

1 1/2

30.0

33.0

1 1/4

33.0

37.0

1 1/2

37.0

41.0

41.0

46.0

46.0

52.0

46.0

52.0

2 1/2

52.0

54.0

2 1/2

54.0

61.0

2 1/2

61.0

66.0

66.0

72.0

72.0

78.0

3 1/4

78.0

84.0

3 1/2

84.0

94.0

94.0

104.0

4 1/2

You might also like