as steam and also to reduce the effect of rapid pressure surges. When first installed the siphon should be filled with water or any other suitable separating fluid.
instrument connection
1/2
material
AISI316
bsp-m
BDT42
BDT45
Note* 1/2 BSP and 1/2 NPT are standard instrument connections. Special executions on request.
For technical data sheets and dimensional drawings please refer to our website www.badotherm.com 21/02/2008 rev 2-B
79
pressure instrumentation
1.1.6.
design information
connection/form details
form
A B C D
design
instrument connection process connection
welding connection 1/2BSP-m welding connection 1/2BSP-m
type
U-shape U-shape pigtail pigtail
1/2BSP-f adjustable socket 1/2BSP-f adjustable socket 1/2BSP-f adjustable socket 1/2BSP-f adjustable socket
drawings
BDT42
dimensions
form
A B C D
BDT43
d2
1/2BSP-m 1/2BSP-m 1/2BSP-m 1/2BSP-m
d1
1/2BSP-f 1/2BSP-f 1/2BSP-f 1/2BSP-f
d
20 20 20 20
H
200 200 240 275
h
155 155 110 145
D
56 56 56 56
L
145 180 -