Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Short column With axial loading

Note:- Editing can be allow only in yellow cells


Loads
P

120

kN

Fck =

25

N/mm2

Fy =

415

N/mm2

Size of column
B
D

=
=

% of Steel
Assumed

230
230

mm
mm

0.8

Effective length
Ley
Lez

2000
2500

mm
mm

Ley / B

8.70

short column in Ley Direction

Lez / D

10.87

short column in Lez Direction

Capacity of column

Pu = 0.4 Fck Area of concrete + 0.67 Fy Area of steel

Pu =

524.77

Pu =

642.44

117.67 kN
kN
column is safe

Area of Steel

423.2

mm2

For Dia of Bar

12

mm

Nos.

No. of bar required =

Short column With Biaxial moments


Note:- Editing can be allow only in yellow cells
Loads
Pu
Muz
Muy

1600
120
90

kN
kN-m
kN-m

Fck =

15

N/mm2

Fy =

415

N/mm2

Size of column
B
D

=
=

% of Steel
Assumed

400
600

mm
mm

1.2

Effective length of column


Ley

4.26

Lez

4.26

Ley / B

10.65

column is short in Ley Direction

Lez / D

7.10

column is short in Lez Direction

Minimum Eccentricity
e = (Effective length of column/500 +( B or D) / 30 ) OR 2cm whichever is max
Ex
Ey

2.19
2.85

cm OR
cm OR

2
2

Whichever is maximum
Whichever is maximum

Moment due to minimum eccentricity

Mz
My

34.97
45.63

kN-m
kN-m

Pu
Muz
Muy

1600
120.0
90.0

kN
kN-m
kN-m

Using Dia of Bar =

25

Actual mmt is max


Actual mmt is max

and Cover

40

mm

d' =

52.5

d' / D
d' / B

0.088
0.131

p/Fck =

0.08

Pu / (Fck x B x D )

For major Dierection.


For minor Dierection.

0.44

Referring chart from SP-16 Page no between 112-147


Considering d' / D , p/Fck , Pu / (Fck x B x D )
Mux1 / (Fck x B x D^2 ) =

Mux1 =

194.4

0.09

kN-m

Similarly
Muy1 / (Fck x B^2 x D) =

Muy1 =

119.52

0.08
Mux1
& Muy1

kN-m

Puz = 0.45 Fck Area of concrete + 0.75 Fy Area of steel


Puz =

2496.96

Pu / Puz =

0.64

Alph =

Ratio =

Ratio =

kN

Mux
Mux1

2.000

( )
Muy
Muy1

Revise % of Steel or Section.

ex
ey
D

My

MZ

Ultimatemoment carrying capacity of section

You might also like