PMT

probe Menard pressure


modulus( E m ),Creep pressure,Limit pressure( P L ,) , ,
, , .
.
.

PMT
Monitering box
Volumeter : 800, 1
2 : 0-25 bar, 0-60 bar
1 () : 0-100 bar
Plastic tube :
3-cell probe : NX size ( 74mm)
Probe
- (Nx)
- (NX)

Monitering box

Probe

NX Menard probe
mm
steel cover
rubber cover

75
74

550
540

330
420

70
69

probe shoe : 80mm, rubber cover : 3mm

PMT
Menard PMT

Tel 02 529-8803

Fax 02 3461-3021

Menard 3 cell probe()


Pa()
Pw()

.

cylindrical

Pw>Pa .
1bar
.

PMT
, , .
(1) ( PL )
(V) 2
.

PL = Pu V0 : probe

V=(V02Vi)

Vi : probe

(P)-(V) (1/V)
2V .
0.006

700
600

0.005

y = -0.0008x + 0.0077
1/V (1/cc)

(cc)

500
400
300

0.004

0.003

200

0.002
100

0.001

0
0

10

(bar)

Tel 02 529-8803

6
P (bar)

Fax 02 3461-3021

(2) E m
600

probe NX
74 mm,

V o 700

500

400

E m = 2.66 pv

P :
V :

V = Vo + Vm
Vo : probe
V m :
Vm = ( Vf + Vi ) / 2

Tel 02 529-8803

(cc)

300

200

Em

100

0
0

4
(bar)