SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

INTRODUCTION
Repair procedures are limited to module replacement. If an INFI-NET to computer interface module fails, remove and replace it with another. Verify that the replacement module dipswitch and jumper settings are the same as those of the failed module.
NOTE: Do not remove INICT01 and INICT03 modules under power unless the stop (INICT01) or stop/reset (INICT03) pushbutton has been depressed and module operation has been halted.

MODULE REPLACEMENT PROCEDURE


Follow Steps 1 through 7 to replace computer interface modules. Observe the steps listed in the SPECIAL HANDLING portion of this manual when handling computer interface modules. 1. Turn the 2 latching screws on the defective computer interface module turn either way to release them. In the case of the INICI03 INFI-NET to Computer Interface, the INICT03 and IMMPI01 or IMMPI02 modules are connected by cable and must be disconnected. 2. Grasp the screws and slide out the module or modules. 3. If necessary, disconnect the cable connecting the modules and remove only the defective module. 4. Set any dipswitches and jumpers on the replacement module to match the settings of the removed module. 5. If necessary, connect the replacement module with any interconnecting modules. 6. Hold the module or modules by the faceplate and slide them into their assigned slots; push until the rear edges of the modules are firmly seated in the backplane connectors. 7. Turn the 2 latching screws on the module or modules turn to lock the modules in place. Modules are locked into the module mounting unit when the open end of the slots on the latching screws face the center of the module faceplate.

I-E96-610A

INTRODUCTION 7-1

REPAIR/REPLACEMENT PROCEDURES

TERMINATION UNIT OR MODULE REPLACEMENT PROCEDURES


To replace the following termination devices, refer to the appropriate instructions for step by step replacement procedures and spare parts information:

NTCL01 Communication Termination Unit. NICL01 Communication Termination Module. NTMF01 Multi-Function Controller Termination Unit. NIMF01 and NIMF02 Multi-Function Controller Termination Modules. NTMP01 Multi-Function Processor Termination Unit. NIMP01 and NIMP02 Multi-Function Processor Termination Modules.

TERMINATION UNIT OR MODULE REPLACEMENT PROCEDURES 7-2