12786A5

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

AMENDMENT NO.

5 AUGUST 2006 TO IS 12786: 1989 IRRIGATION EQUIPMENTPOLYETHYLENE PIPES FOR IRRIGATION LATERALS - SPECIFICATION
(Page 1, clause 3.1) Substitute the following for the existing text: 'The pipe shall be classified by pressure ratings (working pressure) as follows:

Class ofPipe
Class 1 Class 2 Class 3

Working Pressure
0.20 Mpa 0.25 Mpa 0.40 Mpa

Table1 Dimensions of Polyethylene Pipes for Irrigation Laterals


( Clause 5.1 )
All dimensions in millimeters.

Outside Diameter
12 16 20 25 32

No t

Tolerance on Outside DIameter +0.2 +0.2 +0.2 +0.3 +0.3

for

( Page 2, Table 1 ) -

Substitute following for the existing table:

sa
Clusl (0.20Mpa)
0.6-0.8 0.81.0 0.91.1
1.2~1.6

NOTE - Normal working conditions of pipes shall be operation of maximum 800 working hours per year at the pressure rating of the pipe and at a water temperature up to 3'OC. If these working conditions are exceeded the next higher class of pipe, that is, pipe witll. . . . wall thickness shall be chosen. With these woddng conditions the life expectancy of the pipe is 10 years.'

le
I

Class 2 (0.25 Mpa)

Class 3 (O.40Mpa)

1.5-1.9

0.9-1.1 1.1-1.3 1.2-1.4 1.72.0 2.0-2.4

1.2-1.4 1.4-1.6 1.5-1.7 2.1-2.4 2.5-2.9

NOTE - Wall thicknesses of pipes are based on a safe working stress of 2.5 Mpa at 20C. Occasional rise in temperature has no deleterious effects on the life and working prellSW'C of the pipes.

(Amendment No.4) -

Delete the entire text.

Amend No.5 to IS 12786 : 1989

(Page 2, clause 7.3) -

Substitute the following for the existing text:

'The tensile strength of the material and elongation at break of the pipes at 27 3e shall be as follows:

. Tensile Strength at Break Min


12.5 Mpa

Minimum Testing Speed

Elongation at Break Min

100 10 percent

500 percent
Substitute 'A 10 percent Substitute '71 3C'

( Page 5, Annex D, clause D-2.1, line 1 ) diluted (volume/volume) of' for 'An undiluted'.

[ Page 7, Annex D, clause D-4.1 (see also Amendment No.3) Substitute the following for the existing text:
'The pipe is considered to have passed the test if none of the first ten bends fails or, not more than two bends fail in the total sample of twenty bends. '

(FAD 17)

No t

for

sa

(Page 6, Annex D, clause D-2.4.3,first sentence) ---:- Substitute '48 hours' for '30 minutes' and '77 3C' for '50 3C' .

le

(Page 5, Annex D, clause D-2.2, line 2) '50 3e' .

for

Reprography Unit, BIS, New Delhi, India

You might also like