DATA HASILPERCOBAAN p.2

You might also like

Download as rtf, pdf, or txt
Download as rtf, pdf, or txt
You are on page 1of 6

0 MW

0 Mvar

1
slack

Y BUS
Positive
Sequence
Number Name
1
1
2
3

2
3

Negative
Sequence
Number Name
1
1
2

Zero Sequence
Number Name
1
1
2
2
3

Bus 1
0,00 - j16,67

Bus 2
0,00 + j6,67

0,00 + j6,67

1,33 - j9,33
-1,33 + j2,67

Bus 1
0,00 - j16,67

Bus 2
0,00 + j6,67

0,00 + j6,67

1,33 - j9,33
-1,33 +
j2,67

Bus 1
0,00 - j0,72
0,00 + j0,00

Bus 2
0,00 + j0,00
0,67 - j1,33
-0,67 +
j1,33

Bus

-1,33 +
j2,67
1,33 - j2,67

Bus

-1,33 +
j2,67
1,33 - j2,67

Bus

-0,67 + j1,33
0,67 - j1,33

Gangguan pada hubungan fasa ke fasa pada bus 1


Fault Data Buses
Phase Volt
Number Name
A
1
1
1,00001
2
2
1
3
3
1
Arusnya 8.66 <-180pu

Phase Volt
B
0,49999
0,5
0,5

Phase Volt C
0,49999
0,5
0,5

Phase Ang A
0
0
0

Phase Ang B
180
-180
-180

Phase Ang
C
180
180
180

Gangguan pada hubungan fasa ke fasa pada bus 2


Fault Data Buses
Number Name Phase Volt A
1
1
1
2
2
1
3
3
1
Arusnya 3.464 <-180pu

Phase Volt
B
0,72111
0,5
0,5

Phase Volt
C
0,72111
0,5
0,5

Gangguan pada hubungan fasa ke fasa pada bus 3


Fault Data Buses

Phase Ang
A
0
0,09
0,09

Phase Ang
B
-133,9
179,83
179,83

Phase Ang
C
133,9
179,83
179,83

Phase Volt
Number Name
A
1
1
1
2
2
2,19209
3
3
2,19209
Arusnya 1.519<-164.74pu

Phase Volt
B
0,89956
0,77478
0,69209

Phase Volt
C
0,85397
0,93644
0,69209

Phase Ang A
0
0
0

Phase Ang
B
-126,89
-40,16
0

Phase Ang
C
122,59
32,25
0

Gangguan 1 Fasa ke tanah pada bus 1


Fault Data Buses
Number Name Phase Volt A
1
1
0
2
2
0,87421
3
3
0,87421
Arusnya 1.887<-90pu

Phase Volt
B
1,57148
0,97008
0,97008

Phase Volt
C
1,57148
0,97008
0,97008

Phase Ang
A
0
0
0

Phase Ang B
-146,56
-116,78
-116,78

Phase Ang
C
146,56
116,78
116,78

Gangguan 1 Fasa ke tanah pada bus 2


Fault Data Buses
Number Name
1
1
2
2
3
3
Arusnya 0<-90pu

Phase Volt A
1
0
0

Phase Volt
B
1
1,73205
1,73205

Gangguan 1 Fasa ke tanah pada bus 3

Phase Volt
C
1
1,73205
1,73205

Phase Ang
A
0
0
0

Phase Ang
B
-120
-150
-150

Phase Ang C
120
150
150

Fault Data Buses


Number Name
1
1
2
2
3
3
Arusnya 0<-90pu

Phase Volt A
1
0
0

Phase Volt B
1
1,73205
1,73205

Phase Volt
C
1
1,73205
1,73205

Phase Ang
C
120
150
150

Phase Ang A
0
0
0

Phase Ang B
-120
-150
-150

Phase Ang
B
-129,38
-30,01
0

Phase Ang
C
125,05
23,47
0

Gangguan pada bus 2 dan 3 pada posisi 50%


Hubungan fasa ke fasa
Fault Data Buses
Number
1
2
3

Phase Volt
A
1
2,19209
2,19209

Name
1
2
3
FaultP
4
t
2,19209
Arusnya 2.128<-169.38 pu
Hubungan fasa ke tanah
Fault Data Buses

Phase Volt
B
0,84984
0,68604
0,69209

Phase Volt C
0,80237
0,86143
0,69209

Phase Ang
A
0
0
0

0,69209

0,69209

Number
1
2
3

Name
1
2
3
FaultP
4
t
Arusnya 0<-90pu

Phase Volt
A
1
0
0

Phase Volt
B
1
1,73205
1,73205

Phase Volt
C
1
1,73205
1,73205

Phase Ang
A
0
0
0

Phase Ang
B
-120
-150
-150

Phase Ang
C
120
150
150

1,73205

1,73205

-150

150