This document provides specifications for a 3-way pressure compensated flow control valve. The valve maintains a constant output flow between 1 to 3 ports regardless of pressure differences of at least 200 psi, bypassing excess input flow from port 1 to port 2. The output flow can be varied from closed to the valve's maximum rating. Technical data includes pressure and flow specifications, component references, and adjustment details.
This document provides specifications for a 3-way pressure compensated flow control valve. The valve maintains a constant output flow between 1 to 3 ports regardless of pressure differences of at least 200 psi, bypassing excess input flow from port 1 to port 2. The output flow can be varied from closed to the valve's maximum rating. Technical data includes pressure and flow specifications, component references, and adjustment details.
This document provides specifications for a 3-way pressure compensated flow control valve. The valve maintains a constant output flow between 1 to 3 ports regardless of pressure differences of at least 200 psi, bypassing excess input flow from port 1 to port 2. The output flow can be varied from closed to the valve's maximum rating. Technical data includes pressure and flow specifications, component references, and adjustment details.
This document provides specifications for a 3-way pressure compensated flow control valve. The valve maintains a constant output flow between 1 to 3 ports regardless of pressure differences of at least 200 psi, bypassing excess input flow from port 1 to port 2. The output flow can be varied from closed to the valve's maximum rating. Technical data includes pressure and flow specifications, component references, and adjustment details.
COMMON CAVITY VRFD-12A SIZE 12 04.04.04 - X - 57 - Z Rev. 0608 A constant flow rate, regardless of system pressures, is established from 1 to 3 while a minimum pressure differential of 200 psi exists between the two ports. Input flow supplied to 1 in excess of the regulated output at 3 is by-passed to 2. Output flow can be varied from closed to the nominal maximum rating for the valve. Flow from 2 to 1 is not permitted. TECHNICAL DATA Pressure min-max: 200-5000 psi (14-350 bar) Max inlet flow: 32 gpm (120 l/min) Flow range: see below Cavity : CA-12A-3N (see page CT.A.003.U) Line bodies : see page MN1.A External seal kit : see page A11.011 Installation torque : 60-70 ft-lb (81-95 Nm) Weight: 0.661 lbs (0.300 Kg) X ADJUSTMENTS 03 Leakproof hex. socket screw 04 Handknob and locknut
Z REGULATED FLOW RANGE 50 0.26-13.21 gpm 1-50 l/min
FLOW CONTROL, 3-WAY PRESSURE COMPENSATED COMBINATION TYPE FULLY ADJUSTABLE COMMON CAVITY VRFD-12A SIZE 12 04.04.04 - X - 57 - Z