08.04.2013
Operator
Telephone
Fax
e-Mail
Room 1 / Summary
Height of Room: 3.000 m, Mounting Height: 2.400 m, Light loss factor:
0.80
Values in Lux, Scale 1:55
Surface
[%]
E
av
[lx] E
min
[lx] E
max
[lx] u0
Workplane / 645 205 903 0.318
Floor 20 539 263 664 0.487
Ceiling 70 97 64 170 0.660
Walls (6) 50 220 65 1388 /
Workplane:
Height: 0.850 m
Grid: 64 x 64 Points
Boundary Zone: 0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.295, Ceiling / Working Plane: 0.150.
Luminaire Parts List
Specific connected load: 6.83 W/m =1.06 W/m/100 lx (Ground area: 26.36 m)
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
1 6
Philips BPS640 W21L125 1xLED48/840 LIN-
PC (Type 1)* (1.000)
4260 4260 30.0
*Modified Technical Specifications Total: 25560 Total: 25560 180.0