Professional Documents
Culture Documents
Result Heat Xchen
Result Heat Xchen
Result Heat Xchen
20127687
EMD5M4A
RESULT
Counterflow Heat Exchanger
cm3/min
1000
2000
3000
4000
Th, in
(oC)
60
60
59
60
Th, mid
(oC)
50
53
53
54
Power
Power
cm /min Emitted Absorbed
MW
MW
1000
57.58
49.98
2000
82.26
74.97
3000
98.68
83.29
4000
115.17
91.63
3
Power
Lost
MW
7.60
7.29
15.39
23.54
Th, out
(oC)
46
50
51
53
Efficiency
(%)
86.80
91.13
84.41
79.56
Tc, in
(oC)
27
27
27
27
Tc, mid
(oC)
30
32
33
33
Tc, out
(oC)
33
36
37
38
T1
T2
Tm
(oC)
27
24
22
22
(oC)
19
23
24
26
(oC)
22.77
23.50
22.99
23.94
MW/(m2.oC)
32.76
47.62
54.07
57.12
Parellel Flow
cm3/min
1000
2000
3000
4000
Th, in
(oC)
61
61
60
59
Th, mid
(oC)
50
53
53
54
Power
Power
cm3/min Emitted Absorbed
MW
MW
1000
53.47
41.64
2000
82.27
66.62
3000
98.72
74.94
4000
98.68
83.28
Power
Lost
MW
11.83
15.65
23.78
15.40
Th, out
(oC)
48
51
52
53
Efficiency
(%)
77.88
80.98
75.91
84.39
Tc, in
(oC)
28
28
28
28
Tc, mid
(oC)
32
34
34
35
Tc, out
(oC)
33
36
37
38
T1
T2
Tm
(oC)
33
33
32
31
(oC)
15
15
15
15
(oC)
22.83
22.83
22.44
22.04
MW/(m2.oC)
27.22
43.55
49.84
56.40