EN 1993-1-1:2005(E)

Cross-section SHS60x5
Steel quality S355
Eccentricity
Properties of Cross Section
Cross-section
Strengthening
flanges
Cross-
section
RESULTS
t
f
(cm) = 0,5 Cross-section Check 0,20 OK
t
w
(cm) = 0,5
h (cm) = 6 0
b (cm) =
6
d (cm) = 5
A (cm
2
) = 10,8 0,00 10,8
I
y
(cm
4
) =
54
54
I
z
(cm
4
) =
54 54
W
el,y
(cm
3
) =
18 18
W
el,z
(cm
3
) =
18 18
W
pl,y
(cm
3
) =
22 0 22
W
pl,z
(cm
3
) =
22 22
f
y
(N/mm
2
) =
355,0 355,0
i
y
(cm) = 2,24 2,24
i
z
(cm) = 2,24 2,24
G (kg/m) = 8,48 0,00 8,48

0
= 1,32

1
= 1,44
Eccentricity e (m)= 0,000
Acting Section Forces
1,00
Eccentricity e (m)=
0,00

1,00
N = 2 kN
middle M
y
= 0,0 kNm
max support M
y
= 1,0 kNm
min support M
y
= 1,0 kNm
M
y
= 1,0 kNm
V
z
= 3,0 kN
M
z
= 1,0 kNm
V
y
= 1,0 kN
Class 1

EC3 - Uniform Members in bending and Axial force
Section Forces Acting Simultaneously
A = 10,80 cm2
I
y
=
54,10
cm4
I
z
=
54,10
cm4

0
=
1,32
f
yd
=
268,94
MPa
Actions
N
Ed
= 2 kN
M
y,Ed
= 1 kNm
V
z,Ed
= 3 kN
M
z,Ed
= 1 kNm
V
y,Ed
= 1 kN
Resistances
A
v,z
= 3,12 cm2
A
v,y
= 6,00 cm2
V
z,Rd
= 48,44 kN
V
y,Rd
= 93,16 kN
Class 1
W
y
= 22,1 cm3
W
z
= 22,1 cm3
M
y,Rd
= 5,9 kNm
M
z,Rd
= 5,9 kNm
Bending and Shear force (par. 6.2.8)
V
z,Ed
/V
z,Rd
= 0,00 < 0,50 NOT reduce of moment resistance is required
V
y,Ed
/Vy
,Rd
= 0,00 < 0,50 NOT reduce of moment resistance is required

y
= 0,00

z
= 0,00
M
y,V,Rd
= 5,94 kNm
M
z,V,Rd
= 5,94 kNm
Bending and Axial force (par. 6.2.9) without reduced moment resistance due to shear
n= 0,01
a
w
= 0,50
a
f
= 0,50
M
N,y,Rd
= 5,94 kNm == 1 conservative
M
N,z,Rd
= 5,94 kNm
0,20
< 1 OK
6.41
(A) Check against Resistance of Gross Cross Section

b
Rd z N
Ed z
a
Rd y N
Ed y
M
M
M
M
, ,
,
, ,
,

You might also like