Paparan Pengukuran pm30

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 18

PROSEDURE PENGUKURAN

PCS 1900
BERDASAR PADA PM 30
TAHAPAN PENGUKURAN
Tujuan pembagian ini untuk meminimisasi error pengukuran SPA yang
dipengaruhi oleh dynamic range SPA.
METODA PENGUKURAN
1. Over the air (daily operational BALMON)*.
1.1 In band PCS 1900 over the air
1.2 Out band PCS 1900 over the air
2. Di dalam shelter (sesuai dengan PM30)**.
2.1 In band PCS 1900 in shelter
2.2 Out band PCS 1900 in shelter

Note :
*Hasil pengukuran 79 dBc.
**Hasil pengukuran 79 dBc untuk 20 Watt & -47 dBm untuk > 20 watt.



1.1 PENGUKURAN IN BAND OVER THE AIR
Perangkat Connector Spesifikasi Jumlah
Antenna YAGI N - Female Min 15 dB 1
Flexible cable N Male / N - Male 3 meter 2
Adapter connector N Female to N - Female 1
SPA (incl pre amp) N - Female 1
1.1 CONTOH HASIL PENGUKURAN IN BAND
Setting Keterangan
Frequency center 1980 MHz
Span 20 MHz
RBW 100 KHz
Internal ATT 0
Reference level -10 dBm
Meas set up Average - trace
Result in Band :
peak search marker
- 23.85 dBm
1.2 PENGUKURAN OUT BAND OVER THE AIR
Perangkat Connector Spesifikasi Jumlah
Antenna YAGI N - Female Min 15 dB 1
Flexible cable N Male / N - Male 3 meter 2
Filter UMTS 2100 N Female to N - Female 1
SPA (incl pre amp) N - Female 1
1.2 RESPONSE FILTER UNTUK PENGUKURAN OUT BAND
Insertion loss pada frequncy 1980 MHz = -3.6 dB
1.2 CONTOH HASIL PENGUKURAN OUT BAND
Setting Keterangan
Frequency center 1980 MHz
Span 20 MHz
RBW 100 KHz
Internal ATT 0
Internal pre Amp ON
Reference level -40 dBm
Meas set up Average - trace
Result out Band :
Level pada frequency 1980 MHz
- 105.43 dBm
ANALISA PENGUKURAN OVER THE AIR
PENGUKURAN HASIL
IN BAND = A -23.85 dBm
OUT BAND = B -105.43 dBm
LOSS FILTER = C 3.6 dB
TOTAL EMISI = A B - C 78 dBc
PART SPESIFIKASI
Increase level in band
Increase rejection filter Min 50 dB
Reduce Insertion loss filter Max 1 dB
SARAN HASIL PENGUKURAN
2.1 PENGUKURAN IN BAND IN SHELTER
Perangkat Connector Spesifikasi Jumlah
Tapper N - Female 10 dB 1
Flexible cable N Male / N - Male 3 meter 3
Adapter connector N Female to N - Female 1
Adapter connector DIN Male to N - Female 1
Attenuator N Male to N - Female 40 dB 20 watt 1
Dummy Load N Male 100 watt 1
SPA (incl pre amp) N - Female 1
2.1 SETTING PENGUKURAN IN BAND IN SHELTER
PART KETERANGAN
Insertion loss tapper & attenuator 56 dB (A)
Frequency center 1980 MHz
Span 20 MHz
RBW 100 KHz
Internal ATT 0 dB (*)
Reference level -10 dBm (*)
Meas set up Max hold - trace
Marker peak search (B)
Analisa in band C = B + A ( 32 dBm )
C > 32 dBm option -47 dBm.
2.2 PENGUKURAN OUT BAND IN SHELTER
Perangkat Connector Spesifikasi Jumlah
Tapper N - Female 10 dB 1
Flexible cable N Male / N - Male 3 meter 3
FIlter UMTS 2100 N Female to N - Female IL = 1 dB; Rejection 40 dB 1
Adapter connector DIN Male to N - Female 1
Attenuator N Male to N - Female 40 dB 20 watt 1
Dummy Load N Male 100 watt 1
SPA (incl pre amp) N - Female 1
2.2 SETTING PENGUKURAN OUT BAND IN SHELTER
PART KETERANGAN
Insertion loss tapper & attenuator 56 dB (A)
Frequency center 1980 MHz
Span 20 MHz
RBW 100 KHz
Internal ATT 0 dB (*)
Reference level -50 dBm (*)
Meas set up Max hold - trace
Internal Pre Amp ON
Level result frequency 1980 MHz (D)
Analisa Out band E = D + A
> 20 watt E = -47 dBm
20 watt ( C E ) 79 dBc
ANALISA PENGUKURAN OVER THE AIR
PENGUKURAN HASIL
IN BAND C
OUT BAND D
EMISSION TRESHOLD
OPTION 1
C 32 dBm Max value D = -47 dBm
OPTION 2
C < 32 dBm C D 79 dBc