Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 9

How to check RSSI values.

Site NYSYU0012 Belongs to RNC


module 3.
RNC modules 2/3/4/9/10 in ES-1 (extension subrack 1)
RNC Modules 5/6/7/11/12 in ES-2 (extension subrack 2)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 0

S E D E S S S S S S S G G G G G G S S S S S S E D E D S
C T U T P P P P P P P P P P P P P P P P P P P T U T U C
B M M M B B B B B B B B B B B B B B B B B B B M M M M B
- M - - M - M
4 Y 4 A A A A S A 4 Y 4 Y

RNC module 2/5 4/7


9/11 3/6 10/12
(command line interface) Select the Syracuse RNC SYRCNYKKRNC001

Click on log in

Green light and connection established message should pops-up


RSSI value for Alpha sector
RSSI Syracuse Example:

If we take for example NYSYU0012, from the table we


can see that it is on Module 3 & the GPB controlling
Module 3 is located on subrack 01 slot 14 , hence the
representation 011400.

Therefore in order to check for RSSI values we will


need to type:
Lhsh 011400 celldata –cid 00121 The number one
at the end means Alpha sector
Lhsh 011400 celldata –cid 00122 The number two
at the end means Beta sector
Lhsh 011400 celldata –cid 00123 The number three
at the end means Gamma sector

As you will see, by using this method you can see


many other variables in addition to ulinterference
values.
• -101 to -108 is ok 
• -96 to -99 should be monitored and investigated as long term plan 
• -95 is bad and we probably experience accessibility problems.