Pengaturan 5 Lampu (Faizal B)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

PENGATURAN 5 LAMPU (FAIZAL

BACHRI).zm2 -
v1.1
Pengaturan 5 Lampu
Program information
Author : FAIZAL 12-2011-093
Project name : Pengaturan 5 Lampu
Version : 1.1

Module : SR3B261BD
Cycle time in the module : 8 x 2 ms
WATCHDOG action : Inactive
Type of Hardware Input Filtering : Slow (3ms)
Zx keys inactive

Date format : dd/mm/yyyy
Daylight Saving Time change activated
Zone : Other
Change to Daylight Saving Time : May, Last Sunday
Return to winter time : May, Last Sunday

Comments
FAIZAL 12-2011-093
History

Date
21/05/2014
Author
FAIZAL
Version Comment
0.0 TUGAS
INSTRUMEN
FAIZAL
12-2011-093
21-May-14 1 / 4

PENGATURAN 5 LAMPU (FAIZAL).zm2 -
v1.1
Pengaturan 5 Lampu
Program diagram
No Contact 1
I1
Contact 2 Contact 3 Contact 4 Contact 5 Coil
TT1
Comment
I1 switch ON (TRIGGER)
001
T6
002
T1 Q1
Q1 = Lampu 1
003
Q1 TT2
004
T2 Q2
Q2 = Lampu 2
005
Q2 TT3
006
T3 Q3
Q3 = Lampu 3
007
Q3 TT4
008
T4 Q4
Q4 = Lampu 4
009
Q4 TT5
010
T5 Q5
Q5 = Lampu 5
011
TT6
012
013
014
015
016
017
018
019
020
FAIZAL
12-2011-093
021
21-May-14 2 / 4

PENGATURAN 5 LAMPU (FAIZAL).zm2 -
v1.1
Pengaturan 5 Lampu
Physical i nputs
No
I1
Symbol Function
Discrete inputs
Lock
---
Parameters
No parameters
Location of (L/C)
(1/1)
Comment
Physical outputs
No

Q1

Q2

Q3

Q4

Q5
Symbol Function
Discrete
outputs
Discrete
outputs
Discrete
outputs
Discrete
outputs
Discrete
outputs
Latching

No

No

No

No

No
Location of (L/C)

(3/6) (4/1)

(5/6) (6/1)

(7/6) (8/1)

(9/6) (10/1)

(11/6)
Comment
Configurable functions
No
T1

T2

T3

T4

T5

T6
Symbol Function
Timers

Timers

Timers

Timers

Timers

Timers
Lock
No

No

No

No

No

No
Latching
No

No

No

No

No

No
Parameters
See details below

See details below

See details below

See details below

See details below

See details below
Location of (L/C)
(1/6) (3/1)

(4/6) (5/1)

(6/6) (7/1)

(8/6) (9/1)

(10/6) (11/1)

(2/1) (12/6)
Comment
T1
Timer

Timers
Function B: On pulse one shot
Time: 005.0 s
T2 Timers
Function W: Timing after pulse
Time: 005.0 s
FAIZAL12-2011-093 21-May-14 3 / 4


PENGATURAN 5 LAMPU (FAIZAL).zm2 -
v1.1
Pengaturan 5 Lampu
T3 Timers
Function W: Timing after pulse
Time: 005.0 s
T4 Timers
Function W: Timing after pulse
Time: 005.0 s
T5 Timers
Function W: Timing after pulse
Time: 005.0 s
T6 Timers
Function W: Timing after pulse
Time: 000.0 s
FAIZAL12-2011-093 21-May-14 4 / 4