Electric Motor: Satisfactory Unsatisfactory

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

M

(Based on ISO IS 3945)



RMS Overall Velocity Level
Measured
in 1000 Hz Bandwidth
Support Classification
Mm/s In/sec Rigid Supports Flexible Supports
0.46 0.018
Good


Good
0.71 0.028
1.12 0.044
1.80 0.071
2.80 0.110
Satisfactory
4.60 0.180 Satisfactory
7.10 0.280
Unsatisfactory
11.2 0.440 Unsatisfactory
18.0 0.710
Unacceptable
28.0 1.100
Unacceptable 46.0 1.800
71.0 2.800




ELECTRIC MOTOR


Table 3-Recommended Vibration Limits for Electric Motors
(Based on ISO IS 2373)

Motor
Grade
RPM
RMS Velocity amplitude for the following shaft heights, in mm
80 < h < 132 132 < h < 225 225 < h < 400
mm/s in/s mm/s in/s mm/s in/s
Normal 600 - 3600 1.80 0.071 2.8 0.110 4.5 0.177
Reduced
600 - 1800 0.71 0.028 1.12 0.044 1.8 0.071
1801 - 3600 1.12 0.044 1.80 0.071 2.8 0.110
Special
600 - 1800 0.45 0.018 0.71 0.028 1.12 0.044
1801 - 3600 0.71 0.028 1.12 0.044 1.8 0.071

Note:
- RMS velocity amplitude is measured in the frequency range from 10 to 1000 Hz.
- The shaft height is the vertical distance from the base of the motor to the centerline of the shaft







Table 4-Permissible Vibration for Large Induction Motors
(Based on NEMA MG 1-20.52)

RPM
Displacement amplitude (peak to peak), in
inch
3000 - 4000 0.001
1500 - 2999 0.0015
1000 - 1499 0.002
999 and below 0.0025
Motor vibration measurements should be carried out in the condition of motor no-load operation, at rated