7.3.4.

1 Specified compressive cylinder strength of concrete fcat 28 days, shall be not less than
21 MPa (3,000 psi).
7.3.5 Reinforcement in Members Resisting Earthquake Induced Forces
Reinforcement resisting earthquake-induced flexural and axial forces in frame members and in
structural wall boundary elements lying in seismic zones 3 and 4 shall comply with ASTM A706.
ASTM A615, Grades 40 and 60 reinforcement, shall be permitted in these members if:
(a) The actual yield strength based on mill tests does not exceed fy by more than 124 MPa
(18,000 psi) retests shall not exceed this value by more than an additional 21 MPa (3,000 psi); and
(b) The ratio of the actual tensile strength to the actual yield strength is not less than 1.25.
The value of fyt for transverse reinforcement including spiral reinforcement shall not exceed 420
MPa (60,000 psi)