1 2 3 4 5 6 7 8 9 10

1 0.35 0.19 0.26 0.40 0.36 0.23 0.26 0.15 0.23 0.16
2 0.36 0.20 0.25 0.39 0.36 0.22 0.25 0.16 0.22 0.14
3 0.37 0.19 0.26 0.39 0.35 0.24 0.25 0.15 0.23 0.15
Tr.bnh
Average
X
A
Phm vi
Range
R
A
1 0.34 0.20 0.26 0.40 0.36 0.27 0.25 0.15 0.23 0.16
2 0.35 0.21 0.26 0.39 0.36 0.26 0.26 0.16 0.23 0.15
3 0.34 0.20 0.25 0.40 0.37 0.26 0.24 0.16 0.22 0.14
Tr.bnh
Average
X
B
Phm vi
Range
R
B
1 0.36 0.19 0.27 0.40 0.37 0.26 0.25 0.16 0.22 0.16
2 0.34 0.20 0.27 0.41 0.36 0.25 0.26 0.16 0.22 0.15
3 0.34 0.21 0.26 0.40 0.37 0.24 0.25 0.16 0.24 0.16
Tr.bnh
Average
X
C
Phm vi
Range
R
C
X
P
R
P
R
X
DIFF
UCL
R
= ( R x D
4
) UCL
R 0.000
UCL
X
= X + A
2
x R ) UCL
X
LCL
R
= ( R x D
3
) LCL
R 0.000
LCL
X
= X - A
2
x R ) LCL
X
NOTE : D
4
= 3.27 for two trials (2 ln o) A
2
= 1.88 for two trials (2 ln o)
2.58 for three trials (3 ln o) 1.02 for three trials (3 ln o)
PART - CHI TIT O
EQUIPMENT REPEATABILITY AND REPRODUCIBILITY DATA SHEET
DATE-NGY
TAY O 1
APPRAISER # 1
TAY O 2
APPRAISER # 2
A
C
B
PHIU GHI D LIU TNH TON KH NNG SAO CHP & LP LI
Tay o
Appraiser
Ln o
Trials
( Max X ) - ( Min X )
Tr.bnh ca chi tit
Part Average (X
P
)
TAY O 2
APPRAISER # 3
DUYT
APPROVED
KIM TRA
CHECKED
( R
A
+ R
B
+ R
C
) / # of appraisers
ECO Co., Ltd
Part No. & Name : Equipment Name:
M s & tn chi tit Tn thit b o
Characteristic : Serial No. :
c tnh o S seri
USL = 0.5 LSL = 0 Model :
Tolerance (Dung sai): =
From data sheet : R = X
DIFF
= R
P
=
Gi tr ly t trang d liu
Repeatability - Equipment Variation (EV)
(Kh nng sao chp - Bin ng ca d.c) Trials
K
1 % EV = 100(EV/TV) % EV =
EV = R x K
1
2 0.8862 = =
= 3 0.5908
Reproducibility - Appraiser Variation (AV)
(Kh nng lp li - Bin ng ca ngi o) % AV = 100(AV/TV) % AV =
AV = = =
= Appraiser
K
2
n = number of parts (s lng chi tit) 2 0.7071
r = number of trials (s ln o 1 chi tit) 3 0.5231
Repeatability & Reproducibility
(Kh nng sao chp & lp li) % GR&R = 100(GR&R/TV) % GR&R =
GR & R = = =
=
Parts
K
3
Part Variation (PV) 2 0.7071
(Bin ng ca chi tit o) 3 0.5231
PV = R
P
x K
3
4 0.4467 % PV = 100(PV/TV) % PV =
= 5 0.4030 = =
6 0.3742
Total Variation (TV) 7 0.3534
(Tng bin ng) 8 0.3375 ndc = 1.41 (PV/GR&R) ndc =
TV = 9 0.3246 = =
= 10 0.3146
CRITERIA FOR % GR & R:
TIU CH NH GI GR&R
* under 10% error - the measurement system is capable
di 10% - h thng o nng lc
* 10% to 30% error - may be acceptable based upon the importance of application, cost of
gage and cost of repairs.
10% n 30% - c th chp nhn da trn tm quan trng ca h thng o, chi ph
* above 30% - measurement system needs improvement. Make every effort to identify
the problems and have them corrected.
trn 30% - h thng o cn ci tin. C gng xc nh vn & khc phc chng.
Performed by/Ngi thc hin: Date Performed/Ngy:
GR&R
2
+ PV
2
Measurement Unit Analysis - Phn tch n v o
EQUIPMENT REPEATABILITY AND REPRODUCIBILITY REPORT
BO CO TNH TON KH NNG SAO CHP & LP LI
( X
DIFF
x K
2
)
2
- ( EV
2
/ nr )
( EV )
2
+ ( AV )
2
% Variation
(% so vi bin ng)
% Spec Tolerance
(% so vi dung sai)
ECO Co., Ltd
100(EV/(TL/6))
100(AV/(TL/6))
100(GR&R/(TL/6))
100(PV/(TL/6))
1.41 (PV/GR&R)
may be acceptable based upon the importance of application, cost of
c th chp nhn da trn tm quan trng ca h thng o, chi ph
measurement system needs improvement. Make every effort to identify
h thng o cn ci tin. C gng xc nh vn & khc phc chng.
EQUIPMENT REPEATABILITY AND REPRODUCIBILITY REPORT
BO CO TNH TON KH NNG SAO CHP & LP LI
% Spec Tolerance
(% so vi dung sai)
ECO Co., Ltd

You might also like