>>User password:
UA5000(config)#vlan 4000 standard // Vlan for managment
UA5000(config)#interface vlanif 4000
UA5000(config-if-vlanif4000)#ip address 10.1.16.81 24 //IP address for IPMD
{ <cr>|sub<K> }:
Command:
ip address 10.1.16.81 24
UA5000(config-if-vlanif4000)#quit
UA5000(config)#port vlan 4000 //to make the port fo
r vlan
{ frameid/slotid<S><1,15>|to<K> }:0/2
{ portlist<S><1,64> }:0
Command:
port vlan 4000 0/2 0
UA5000(config)#vlan 51 smart // service vlan
UA5000(config)#vlan attrib 51 stacking
UA5000(config)#multi-service-port vlan 51 board // add service port f
or all board
{ frameid<U><0,5> }:0
{ num-list<S><1,64> }:6-35
{ autosense<K>|rx-cttr<K>|user-8021p<K>|user-encap<K>|user-vlan<K>|vpi<K> }:vpi
{ vpi<U><0,255> }:8
{ vci<K> }:vci
{ vci<U><32,255> }:35
{ rx-cttr<K>|user-8021p<K>|user-encap<K>|user-vlan<K> }:rx-cttr
{ rx-index<U><0,511> }:6
{ tx-cttr<K> }:tx-cttr
{ tx-index<U><0,511> }:6
Command:
multi-service-port vlan 51 board 0 6-35 vpi 0 vci 35 rx-cttr 6 tx-cttr
UA5000(config)#stacking label vlan 51 // to make vlan lable
{ baselabel<K> }:baselabel
{ baselabel<U><1,4095> }:2 // start from 2, but if
one site use the same vlan, so this need to start from the other frame finish
Command:
stacking label vlan 51 baselabel 2
UA5000(config)#save
{ <cr>|configuration<K>|data<K> }:
Command:
save
UA5000(config)#port vlan 51
{ frameid/slotid<S><1,15>|to<K> }:0/2
{ portlist<S><1,64> }:0
Command:
port vlan 51 0/2 0
UA5000(config)#interface ipm
{ frameid/slotid<S><1,15> }:0/2
Command:
interface ipm 0/2
UA5000(config-if-ipm-0/2)#link-aggregation
{ port-list<S><1,255> }:0-1
{ mode<E><ingress,egress-ingress> }:ingress
{ <cr>|workmode<K> }:workmode
{ lacp-static<K> }:lacp-static
Command:
link-aggregation 0-1 ingress workmode lacp-static
UA5000(config-if-ipm-0/2)#quit
UA5000(config)#protect
UA5000(config-protect)#protect-group
{ first<K>|switch-over<K> }:first
{ frameid/slotid/portid<S><1,15>|frameid/slotid<S><1,15> }:0/2/0
{ second<K> }:second
{ frameid/slotid/portid<S><1,15> }:0/3/0
{ atm<K>|eth<K> }:eth
{ workmode<K> }:workmode
{ lacp<K>|portstate<K>|timedelay<K> }:lacp
{ disable<K>|enable<K> }:enable
Command:
protect-group first 0/2/0 second 0/3/0 eth workmode lacp enable
UA5000(config-protect)#quit
UA5000(config)#save
for Native:-------------------------normally no need to do this part
UA5000(config)#interface ipm 0/2 //inter to ipm active board
UA5000(config-if-ipm-0/2)#native-vlan // add native vlan
{ all<K>|portid<U><0,9> }:0
{ vlan<K> }:vlan
{ vlanid<U><1,4093> }:1015 //Vlan ID
Command: