Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

Pre- Activity Check:

1) Please take the RNC Configuration Backup before the activity in corresponding RNC.
2) Prepare Roll-Back Script if issue occurs after implementation. For that, Removal mml command also given below.


MOP for external definition and neighbor addition:
1) For 3G to 2G neighbor addition or cell reselection, use this command,

ADD U2GNCELL: RNCID="x", CELLID="x", GSMCELLINDEX="x", BLINDHOFLAG=FALSE,
NPRIOFLAG=FALSE;

2) For 3G to 3G(Intra frequency neighbor addition , use this command,
ADD UINTRAFREQNCELL: RNCID="x", CELLID="x", NCELLRNCID="x", NCELLID="x", SIB11IND=TRUE,
SIB12IND=FALSE, TPENALTYHCSRESELECT=D0, NPRIOFLAG=FALSE;


3) For 3G to 3G(Inter frequency neighbor addition or cell reselection, use this command,
ADD UINTERFREQNCELL: RNCID="x", CELLID="x", NCELLRNCID="x", NCELLID="x", SIB11IND=TRUE,
SIB12IND=FALSE, TPENALTYHCSRESELECT=D0, BLINDHOFLAG=FALSE, NPRIOFLAG=FALSE;


4) For 3G external cell(it can be Huawei/Ericsson) in RNC, use this command,
ADD
UEXT3GCELL:NRNCID="x",CELLID="x",CELLHOSTTYPE=SINGLE_HOST,CELLNAME=""x"",CNOPGRPINDEX="x
",PSCRAMBCODE="x",BANDIND="x",UARFCNUPLINKIND=FALSE,UARFCNDOWNLINK="x",TXDIVERSITYIND=F
ALSE,LAC="x",CFGRACIND=REQUIRE,RAC="x";


5) For 2G external cell(it can be Huawei/Ericsson) in RNC, use this command,
ADD UEXT2GCELL: GSMCELLINDEX="x", GSMCELLNAME=""x"", MCC="x", MNC="x", RAC="x",
CNOPGRPINDEX="x", LAC="x", CFGRACIND=REQUIRE, CID="x", NCC="x", BCC="x", BCCHARFCN="x";



MOP for Roll Back:
RMV U2GNCELL: RNCID="x", CELLID="x", GSMCELLINDEX="x";
RMV UINTRAFREQNCELL: RncId="x", CellId="x", NCellRncId="x", NCellId="x";
RMV UINTERFREQNCELL: RncId="x", CellId="x", NCellRncId="x", NCellId="x";
RMV UEXT3GCELL: NRncId="x", CellId="x";
RMV UEXT2GCELL: GSMCELLINDEX="x";

Post-Activity Check:

1) Drive Test to be performed after the RF parameters changes for the corresponding Cells to check the Voice
Calls/Video Calls/R99-HSDPA/HSUPA services/Cell Selection-Reselection.
2) Ensure there should not be any critical alarm in the system.

You might also like