Thickness:
Visible Fluorescent Solvent Removable
Penetrant Material
Natural White Ultraviolet
Luxometer:
1 Porosity, weld defects
ASME SEC. VIII DIV. 1 2010 ADD 2011
CONDITION SURFACE
Free - rust was removed
Authorized Inspector, OneCis Insurance Co.
Name: Bolvar Gonzlez, NB 15137
Date: Signature:
CLIENT: ALQUISER ECUADOR CIA LTDA. Order No.: N.A.
LIQUID PENETRANT EXAMINATION
INSPECTION REPORT
PT-2014-003
Page
INSPECTION PLACE: EXAMINATION PERFORMED
ANDESPETROLEUM Weld
Examination of: Lift points of equipments Butt weld's
Technique:
Type/Model: Water Treatment Eq. Fillet weld's
Serial No.: 280 Others
Part of Examination: Lifting points of structure
Material: SA-36 NA
Procedure: Rev.:
Mark Reference Lot Dwell Time
10 min
Ilumination Type:
Remover/Cleaner MAGNAFLUX SKC-S 41570 5 min
Penetrant MAGNAFLUX SKL-SP2 4499 5 min
Developer MAGNAFLUX SKD-D2 2274
NA Calibration Date: NA
INSPECTION RESULTS
Machined Other
ACCEPTANCE CODE CRITERIA
Rough As welded Sand Blasted
Brushed Grinding
RESULTS
Accepted ACC Non Accepted NAC Sketch attached
REMARKS:
03-ago-14
1