10-76 I E S LIGHTING HANDBOOK

~L
FIG. 10-52. A sight-saving classroom.
Table 10-10. Recommended Illumination Levels for Classrooms and
Other School Areas
AREA
Classrooms, including study halls, libraries, shops, lecture
rooms, laboratories, etc
Sight-saving classrooms, drafting rooms, and sewing rooms
Gymnasiums and swimming pools
Auditoriums, cafeterias, and similar rooms not used for study..
Reception rooms, locker rooms, washrooms, stairways, and cor-
ridors containing lockers
Corridors and storerooms
FOOTCANDLES
MAINTAINED
IN SERVICE
30
50
20
10
10
5
Table 10-11. Recommended Brightness-Ratio Range Limits for
Classrooms and Other School Areas
AREAS
Task and immediate background such as desk top, wall,
etc
Task and more remote parts of room
Light source (luminaire or sky) and adjacent ceiling or
wall
In no case should the ratio be combined to suggest the
acceptability of a range greater than
RECOMMENDED BRIGHT-
NESS RATIO RANGE
LIMITS IN NORMAL
FIELD OF VIEW
1 to
3
3 to 1
1 to 1010 to 1
1 to 2020 to 1
1 to 3030 to 1