This document discusses reducing power consumption at telecom sites by optimizing cooling systems. It states that typically 30% of power is used for cooling whole environments, when only the equipment space needs cooling. The document proposes shifting radio equipment and batteries to outdoor cabinets to optimize the cooling space. This would provide a sealed, dust-free environment while separating equipment and power for increased reliability. Outdoor cabinets could save energy by allowing unique external fan control and low-noise, corrosion-resistant cooling optimized for the equipment load.
This document discusses reducing power consumption at telecom sites by optimizing cooling systems. It states that typically 30% of power is used for cooling whole environments, when only the equipment space needs cooling. The document proposes shifting radio equipment and batteries to outdoor cabinets to optimize the cooling space. This would provide a sealed, dust-free environment while separating equipment and power for increased reliability. Outdoor cabinets could save energy by allowing unique external fan control and low-noise, corrosion-resistant cooling optimized for the equipment load.
This document discusses reducing power consumption at telecom sites by optimizing cooling systems. It states that typically 30% of power is used for cooling whole environments, when only the equipment space needs cooling. The document proposes shifting radio equipment and batteries to outdoor cabinets to optimize the cooling space. This would provide a sealed, dust-free environment while separating equipment and power for increased reliability. Outdoor cabinets could save energy by allowing unique external fan control and low-noise, corrosion-resistant cooling optimized for the equipment load.
This document discusses reducing power consumption at telecom sites by optimizing cooling systems. It states that typically 30% of power is used for cooling whole environments, when only the equipment space needs cooling. The document proposes shifting radio equipment and batteries to outdoor cabinets to optimize the cooling space. This would provide a sealed, dust-free environment while separating equipment and power for increased reliability. Outdoor cabinets could save energy by allowing unique external fan control and low-noise, corrosion-resistant cooling optimized for the equipment load.
Station Climate Control For Outdoor Station Climate Control For Outdoor
Cabinet Applications Cabinet Applications
Proposed by: Muditha Dasanayake Bsc.Eng(Hons) CCNA,AMIE(SL) Who Consumes What ? 62% 25% 11% 1%1% Power Consumption Percentage Radio Equipment Cooling DC Power RF load Feeder Figure 1: Typical Energy usage of Telecom Site Source: ATIS Report wireless Network Energy Efficiency Energy Sustainability?? Todays Energy Demand. Only less of the total power can be converted to effective RF energy Should reduce power wastagethrough the network Steps To Reduce Power Consumption Radio equipment power wastage- moving the radio equipments closer to antenna Already achieved in almost all operators using RBS/ DBS systems Radio Equipment Power Wastage Contd.. Dynamic sleep mode software to power down during low traffic periods -Can be achieved with the existing vendors using advanced features Advanced power amplifiers -Depends on vendor specification. How to Reduce DC Power Consumption Use the maximum efficient zone, with load >40% of the rectifier capacity can be achieved using software simulated activities (sleep mode) Using High efficient rectifiers. (Efficiency>96%) Typical characteristics curve for rectifier Cooling Wastage?? Typically 30% of power consumed for cooling at a site Cooling the whole environment is not needed It should be optimized only for equipment space Should give dust free environment to the equipment Equipment reliability should maintain Indoor to Outdoor Cabinet Shifting Cooling space can be optimized using outdoor cabinets Sealed environment provides dust free interface Equipment and power separation creates more reliability to the system Solution for DBS/RBS Equipment space Battery bank Proposed cabinet structure for DBS/RBS Indoor Solution for old BTS Proposed structure for older BTS with TREs Equipment cabinet Battery cabinet Benefits of using DC/EC Air Cons. Note: EC- Electronically commutated. Energy saving: Unique external fan control function available for energy saving as well asemergency working mode Low noise: The noise level of the unit is reduced according to the heat load, silently operating inmost time Corrosion protection: Powder coated sheet metal endures harsh environment Easy maintenance: IP55 design for flushing