1505 - 16 Elematic Cross Section Elematic Hollow Core Plank

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Load Table

Strand
Strand
Area(in2)
Pattern
16S7.6(48)-2.13
2.131
16S4.6(68)-2.02
1.786
16S4.6(48)-1.75
1.480
16S88-1.75
1.224

Strand
Strand
Area(in2)
Pattern
16S7.6(48)-2.13
2.131
16S4.6(68)-2.02
1.786
16S4.6(48)-1.75
1.480
16S88-1.75
1.224

Ac
bw
Ig
yb
wt
f'ci
f'c
fpu

Maximum Uniformly Distributed Load (psf)


Clear Span (Feet)
42
44
46
48
50
52
54
56
168 157 147 138 130 122 115 108
163 152 142 133 125 117 110 104
157 147 137 128 120 111 96
83
153 143 125 109 94
-

38
194
187
181
177

40
180
174
168
164

58
102
92
71
-

60
96
79
-

38
1.45
1.14
0.89
0.62

Estimated Camber at Time of Erection (inches)


Clear Span (Feet)
40
42
44
46
48
50
52
54
56
58
60
1.52 1.59 1.63 1.66 1.66 1.64 1.59 1.51 1.40 1.25 1.05
1.18 1.20 1.21 1.20 1.16 1.10 1.01 0.88 0.72 0.52 0.27
0.90 0.90 0.88 0.83 0.76 0.67 0.54 0.38 0.18 -0.06 0.60 0.57 0.51 0.43 0.33 0.19
-

=349in2
=11.69in
=11401in4
=8.3in
=92psf
=5000psi
=9000psi
=270ksi

Notes:
1.TabulateduniformdistributedloadsinthistablearebasedonACI31805/318R05.
2.Allcalculatedloadsareconsideredassuperimposedliveloadbasedon1.2DL+1.6LL.
3.Toppingweightisnotincludedintabulatedvalues.Sizeandlocationofopeningsmayeffecttablecapacity.
4.Allprestressingstrandisstressedto70%offpu.
5.TabulatedloadsintheshadedregionhaveliveloaddeflectionsgreaterthanL/360.
6.Plankis1hourfireratedperIBC2006.ForhigherratingspleasecontactKP.
7.ForlongerspansorconditionsnotcoveredbythistablepleasecontactKP.

16LIGHTCROSSSECTION
ELEMATICHOLLOWCOREPLANK

3/14/11

1505

You might also like