Professional Documents
Culture Documents
Single Core & Multicore Flexible Cables
Single Core & Multicore Flexible Cables
MULTICORE
FLEXIBLE
CABLES
IS 694:1990
BUREAU VERITAS
Certification
CM/L 6139768
No of Cores
1 Core
2 Core
3 Core
4 Core
5 Core
DRAWING
TEST ON WIRE
CONDUCTOR STRANDING
TEST ON
STRANDED CONDUCTOR
EXTRUSION OF PVC INSULATION
PROCESS
PRIME
MARKET SEGMENT
TEST ON
PVC Compound
TEST
TEST ON CORES
EXTRUSION OF SHEATH
PVC COMPOUND
TEST OF FINISHED
CABLE
For Single Core Cable
PACKING
IS 694:1990
As per
l Airports
l Automobile
l Mining
Sq mm
1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
3
3
7
7
7
7
19
19
19
37
37
37
37
61
61
61
91
91
91
Circular Compacted
Or Shaped Conductor
Aluminium
Copper
_
_
_
_
_
_
_
_
_
_
_
6
6
6
6
6
12
15
18
18
30
34
34
53
53
53
53
53
6
6
6
6
12
15
15
15
30
30
30
53
53
53
53
53
Ohm/km
18.1
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.047
0.0366
0.0283
0.0221
0.0176
18.2
12.2
7.56
4.7
3.11
1.84
1.16
0.734
0.529
0.391
0.27
0.195
0.154
0.126
0.100
0.0762
0.0607
0.0475
0.0369
0.0286
0.0224
0.0177
Ohm/km
_
18.1
12.1
7.41
4.61
3.08
1.91
1.2
0.868
0.641
0.443
0.32
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.0469
0.0367
0.0291
Nominal
Cross
Sectional
Area
sq.mm
Maximum
Diameter of
Wires in
Conductor
0.5
0.75
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
0.21
0.21
0.21
0.26
0.26
0.31
0.31
0.41
0.41
0.41
0.41
0.41
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.61
0.61
Maximum Resistance of
Conductor at 20 deg. C
Plain Wires
Ohm/Km
39
26
19.5
13.3
7.98
4.95
3.3
1.91
1.21
0.78
0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
0.0641
0.0486
0.0384
0.0287
Tinned Wires
Ohm/Km
40.1
26.7
20
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
0.393
0.277
0.21
0.164
0.132
0.108
0.0817
0.0654
0.0495
0.0391
0.0292
Number
Nominal
Thickness
/Nom
Cross
of
Diameter of
Sectional Conductor Insulation
Area
(Nom)
Strand (*)
mm
mm
sq.mm
Conductor
Appx.
Resistance
Overall
(Max)
Diameter
0
at 20 C
mm
Ohm/km
0.5
16 / 0.2
0.6
2.3
39
0.75
24 / 0.2
0.6
2.4
26
14 / 0.3
0.7
2.7
19.5
1.5
22 / 0.3
0.7
3.2
13.3
2.5
36 / 0.3
0.8
3.8
7.98
56 / 0.3
0.8
4.2
4.95
84 / 0.3
0.8
4.8
3.3
Number /
Nominal
Diameter of
Each Strand
mm
Nominal Cross
Sectional Area
of Conductor
Sq mm
1.0 (Solid)
1.0 (Stranded)
1.5 (Solid)
1.5 (Stranded)
2.5 (Solid)
2.5 (Stranded)
4.0 (Solid)
4.0 (Stranded)
6.0 (Solid)
6.0 (Stranded)
10.0 (Solid) Aluminium
10.0 (Stranded)
16.0 Stranded Compacted
25.0 Stranded Compacted
35.0 Stranded Compacted
50.0 Stranded Compacted
70.0 Stranded Compacted
95.0 Stranded Compacted
120.0 Stranded Compacted
150.0 Stranded Compacted
185.0 Stranded Compacted
240.0 Stranded Compacted
300.0 Stranded Compacted
400.0 Stranded Compacted
500.0 Stranded Compacted
630.0 Stranded Compacted
1 / 1.12
7 / 0.43
1 / 1.38
7 / 0.53
1 / 1.78
7 / 0.67
1 / 2.24
7 / 0.85
1 / 2.76
7 / 1.04
1 / 3.52
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
7 / 2.92
19 / 2.14
19 / 2.52
19 / 2.88
19 / 3.20
37 / 2.52
37 / 2.88
37 / 3.20
61 / 2.92
61 / 3.20
61 / 3.65
Thickness Overall
of
Diameter
Insulation ( Appx. )
(Nominal)
mm
mm
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.8
2.8
Nominal Cross
Sectional Area
of Conductor
Sq mm
2.75
2.9
3.0
3.2
3.6
3.8
4.0
4.4
4.6
5.0
5.8
6.2
7.3
9.0
10.2
12.0
13.8
16.0
18.0
20.0
22.0
25.0
27.5
32.0
35.0
39.5
Number /
Nominal
Diameter of
Each Strand
mm
Thickness
of
Insulation
(Nominal)
Overall
Diameter
( Appx. )
mm
mm
0.5
16 / 0.2
0.6
2.3
0.75
24 / 0.2
0.6
2.4
32 / 0.2
0.6
2.75
1.5
30 /0.25
0.7
3.3
2.5
50 / 0.25
0.8
3.9
56 /0.3
0.8
4.3
84 / 0.3
0.8
4.9
10
80 / 0.4
1.0
6.4
16
126 / 0.4
1.0
7.4
25
196 / 0.4
1.2
9.4
35
276 / 0.4
1.2
10.4
50
396 / 0.4
1.4
12.7
70
360 / 0.5
1.4
15.0
95
475 / 0.5
1.6
16.8
120
608 / 0.5
1.6
18.0
150
750 / 0.5
1.8
20.0
185
925 / 0.5
2.0
21.2
240
1221 / 0.5
2.2
24.5
300
1525 / 0.5
2.4
26.8
400
2036 / 0.5
2.6
30.5
1.5
2.5
10
16
25
35
50
70
95
No & Size of each strand 32/0.2** 30/0.25 OR 50/0.25 OR 56/0.3 84/0.3 80/0.4 or 126/0.4 196/0.4 276/0.4 396/0.4 360/0.5 475/0.5
(mm)
48/0.2
80/0.2
140/0.3
Max.Conductor
Resistance at 20 degC
(ohm / km)
120
608/0.5
19.5
13.3
7.98
4.95
3.3
1.91
1.21
0.78
0.554
0.386
0.272
0.206
0.161
Thickness of Insulation
(mm)
0.6
0.6
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
Single Core
(Unsheathed) Overall
Diameter (mm)
2.7
3.2
3.8
4.2
4.8
6.4
7.4
9.4
10.4
12.7
15
16.8
18.0
0.8
4.4
0.8
5.0
0.8
5.6
0.9
6.2
0.9
6.8
0.9
8.4
1
9.6
1.1
11.8
1.1
12.8
1.2
15.3
1.2*
17.6
1.4*
19.8
1.4*
21.0
2 Core Sheathed
Sheath Thickness (mm)
Overall Diameter (mm)
0.9
7.4
0.9
8.4
1.0
9.8
1.0
10.6
1.1
12.0
1.2
15.4
1.3
17.6
1.4
21.8
1.5
24.0
1.6
28.8
1.7*
33.6
1.8*
37.4
1.9*
40.0
3 Core Sheathed
Sheath Thickness (mm)
Overall Diameter (mm)
0.9
7.9
0.9
9.0
1.0
10.6
1.1
11.6
1.1
12.8
1.2
16.5
1.3
18.8
1.5
23.6
1.6
25.9
1.7
31.1
1.8*
36.2
1.9*
40.3
2.0*
43.1
4 Core Sheathed
Sheath Thickness (mm)
Overall Diameter (mm)
0.9
8.6
0.9
10.0
1.0
11.6
1.1
13.0
1.2
14.8
1.3
19.0
1.4
21.5
1.6
26.2
1.7
29.0
1.8
34.7
1.9*
40.5
2.0*
45.0
2.1*
48.1
5 Core Sheathed
Sheath Thickness (mm)
Overall Diameter (mm)
1.0
9.6
1.0
11.0
1.0
12.7
1.1
14.0
1.2
15.8
1.3
20.2
1.4
23.1
1.6
28.9
1.7
32.0
1.8
38.2
1.9*
44.7
2.0*
49.8
2.1*
53.0
35
50
7/1.35
7/1.70
7/2.14
7/2.52
7/2.92
19/2.14 19/2.52
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4*
1.6*
1.6*
3.8
4.4
5.0
6.2
7.3
9.0
10.2
12.0
13.8
16.0
18.0
0.8
5.0
0.8
5.8
0.9
6.5
0.9
7.2
0.9
8.4
1.0
9.8
1.1
11.5
1.1
13.1
1.2
15
1.2*
17
1.4*
19.7
1.4*
21.2
0.9
7.9
0.9
8.5
1.0
10.0
1.0
11.0
1.1
12.6
1.2
15.2
1.3
17.6
1.4
21.2
1.5
23.8
1.6
27.6
1.7*
31.5
1.8*
36.0
1.8*
40.0
3 Core Sheathed
Sheath Thickness (mm)
Overall Diameter (mm)
0.9
8.5
0.9
9.1
1.0
10.6
1.1
12.1
1.1
13.4
1.2
16.2
1.3
18.8
1.5
22.8
1.6
25.7
1.7
29.7
1.7*
33.6
2.0*
39.0
2.0*
43.2
4 Core Sheathed
Sheath Thickness (mm)
Overall Diameter (mm)
0.9
9.2
0.9
10.0
1.0
11.6
1.1
13.2
1.2
14.8
1.3
18.1
1.4
21.0
1.6
25.5
1.7
28.5
1.8
33.0
1.8*
37.5
2.0*
43.2
2.0*
48.0
7/0.53
7/0.67
18.1
12.1
7.41
4.61
Thickness of Insulation
(mm)
0.7
0.7
0.8
Single Core
(Unsheathed) Overall
Diameter (mm)
2.9
3.2
0.8
4.7
2 Core Sheathed
Sheath Thickness (mm)
Overall Diameter (mm)
Max.Conductor
Resistance at 20 degC
(ohm / km)
7/0.85 7/1.04
70
95
120
19/2.88
10 12
14 16
19
Core
Diameter
(mm)
25
10
12
14
16
19
25
core core core core core core core core core core core core core core core core core core core core
0.5
0.6
0.9
9.0
2.3
0.75
0.6
0.9
2.4
1.0
0.6
1.0
2.7
1.5
0.6
1.0
3.2
2.5
0.7
1.0
3.8
0.5
0.6
2.3 X 4.6
4.6
0.75
0.6
2.4 X 4.8
4.8
1.0
0.6
2.7 X 5.4
5.4
1.5
0.6
3.2 X 6.4
6.4
2.5
0.7
3.8 X 7.6
7.6
4.0
0.8
4.2 X 8.4
8.4
9.5
sq.mm
(A)
Voltage
Drop /
Meter
(mv)
3 or 4 cables,
3 phase AC
Current Voltage
Carrying Drop /
Meter
Capacity
(A)
(mv)
Trefoil /
3 or 4 cables, 3 phase AC
3 cables / 3 phase
Current
Carrying
Capacity
Voltage
Drop /
Meter
Current
Carrying
Capacity
(A)
(mv)
Voltage
Drop /
Meter
(mv)
_
13
40
12
35
16
40
16
35
(A)
_
1.5
16
27
17
23
20
27
17
23
2.5
22
16
24
14
28
16
24
14
_
_
30
10
30
8.8
37
10
30
8.8
38
6.8
38
5.9
47
6.8
39
5.9
_
_
10
52
4.0
50
3.5
63
4.0
57
3.5
16
70
2.6
64
2.2
85
2.6
66
2.2
_
_
25
91
1.6
81
1.4
110
1.6
90
1.4
35
112
1.2
99
1.0
136
1.2
110
1.0
50
136
0.97
125
0.84
164
0.93
135
0.82
125
0.8
70
173
0.70
150
0.62
207
0.65
165
0.59
153
0.59
95
216
0.59
175
0.48
253
0.48
200
0.45
189
0.42
120
244
_
0.48
_
195
_
0.42
_
291
0.40
230
0.38
220
0.34
333
0.34
265
0.34
253
0.29
150
185
381
0.29
305
0.3
290
0.25
240
452
0.24
355
0.27
342
0.22
300
526
0.22
400
0.25
405
0.19
400
639
0.2
455
0.24
483
0.17
500
752
0.18
513
0.23
561
0.16
630
855
0.17
591
0.22
631
0.15
20
30
35
40
45
50
55
60
65
Rating Factor
1.06
0.94
0.87
0.79
0.71
0.61
0.5
0.35
3)
Type : DESCRIPTION
A) Single Core and Multi Core Cables enclosed in a Conduit.
B) Single Core and Multi Core Cables enclosed in Cable Trunking.
C) Single Core and Multi Core Cables enclosed I Underground Conduit ducts and cable ducting
D) The term clipped direct is explained below.
Type : DESCRIPTION
A) Sheathed Single Core and MultiCore Cables clipped direct to or lying on a non metallic surface.
B) Sheathed Single Core and MultiCore Cables on a Cable Tray, bunched and unenclosed.
C) Sheathed Single Core and MultiCore Cables suspended from incorporating a catenary Wire.
27
(A)
(mv)
17
23
Voltage
Drop /
Meter
(mv)
(mv)
2.5
27
16
24
14
35
10
30
8.8
44
6.8
39
5.9
46
6.8
40
5.9
10
60
4.0
52
3.5
63
4.0
54
3.5
16
82
2.6
66
2.2
86
2.6
70
2.2
25
110
1.6
90
1.4
116
1.6
95
1.4
35
130
1.2
110
1.0
137
1.2
116
1.0
50
165
0.93
135
0.82
177
0.93
143
0.82
70
205
0.65
165
0.59
216
0.65
175
0.59
95
245
0.48
200
0.45
258
0.48
211
0.45
120
280
0.4
230
0.38
295
0.4
243
0.38
150
320
0.34
265
0.34
338
0.34
280
0.34
185
370
0.29
305
0.3
390
0.29
318
0.3
240
425
0.24
355
0.27
449
0.24
376
0.27
300
475
0.22
400
0.25
502
0.22
424
0.25
400
550
0.2
455
0.24
581
0.2
482
0.24
2 Cables,
Single Phase AC/DC
Current
Voltage
Carrying
Drop /
Capacity
Meter
(A)
(mv)
2 Cables,
Single Phase AC/DC
Current
Voltage
Carrying
Drop /
Capacity
Meter
(A)
(mv)
3 or 4 cables
3 phase AC
Voltage
Current
Drop /
Carrying
Meter
Capacity
(A)
(mv)
3 or 4 cables
3 phase AC
Voltage
Current
Drop /
Carrying
Meter
Capacity
(A)
Trefoil
3 cables / 3 phase
Current
Carrying
Capacity
Voltage
Drop /
Meter
(mv)
(A)
(mv)
16
60
4.5
51
3.9
72
4.5
64
3.9
25
76
2.8
70
2.5
92
2.8
84
2.5
35
92
86
1.8
111
2.1
105
1.8
50
110
1.6
105
1.4
133
1.5
130
1.3
140
1.3
70
135
1.2
130
166
1.1
155
0.93
170
0.9
95
165
0.85
155
0.8
213
0.76
190
0.7
205
0.67
120
185
0.7
180
0.7
241
0.62
220
0.56
235
0.54
150
210
0.64
205
0.64
273
0.5
250
0.48
270
0.48
185
317
0.4
290
0.4
310
0.37
240
383
0.32
335
0.34
370
0.3
300
448
0.28
380
0.3
435
0.25
400
542
0.2
435
0.26
530
0.2
500
672
0.16
480
0.24
600
0.2
(mv)
(mv)
16
62
4.5
52
3.9
65
4.5
54
3.9
25
80
2.9
73
2.5
84
2.8
77
2.5
35
98
2.1
89
1.8
102
2.1
94
1.8
50
110
1.7
111
1.4
115
1.5
116
1.3
70
135
0.95
138
1.0
143
1.1
143
0.93
95
175
0.79
168
0.8
185
0.76
177
0.7
120
195
0.7
200
0.56
150
222
0.64
232
0.48
185
252
0.37
265
0.4
240
301
0.29
316
0.34
300
345
0.25
363
0.3
NOTE :
1) All the above rating are based on ambient Temperature of 30 deg C and are in accordance with IEEE regulation.
2) Rating Factor for higher ambient temperature.
AMBIENT TEMP.
RATING FACTOR
25
1.08
30
1
35
0.94
40
0.87
45
0.79
50
0.61
55
0.5
60
0.35
65
0.25
Number / Nom
Diameter of
conductor
strand
mm
16/0.2
24/0.2
14/0.3
22/0.3
36/0.3
56/0.3
84/0.3
Thickness of
insulation
Appr. Over
all Diameter
Current carrying
capacity in conduit/
Trunking
Conductor
Resistance (Max )
at 20C
mm
0.6
0.6
0.7
0.7
0.8
0.8
0.8
mm
2.3
2.4
2.7
3.2
3.8
4.2
4.8
Amps
6
8
13
16
20
26
36
Ohms/km
39.0
26.0
19.5
13.3
7.98
4.95
3.30
SBEE BRAND WINDING WIRES & 3 CORE FLAT CABLES FOR SUBMERSIBLE PUMP MOTORS
We have been manufacturing SBEE brand of PVC and other general purpose and specialised cables for almost a decade. After
gaining experience in above field, SBEE brand ventured into the specialised field of wrapped winding wire and 3CORE FLAT
CALBES for Submersible Pumps during 1998. We have now introduced HR PVC insulated SUBMERSIBLE WINDING WIRES.
In Submersible Pumps Motors liquid is used surrounding the stator winding and are therefore known as wet Rotor Motors. To
preserve the life and efficiency of the motor, the quality of winding wires sould be very good. The insulating material should also be
imprevious to liquids. SBEE windings wires are specially designed and manufactured for these purposes.
SUBMERSIBLE 3 CORE FLAT CABLE
It has been observed in practice and through laboratory tests that submersible 3 core flat cables are as important as winding wires
for trouble free working of the submersible pumps. SBEE 3 core flat cables are manufactured by keeping in mind the severe and
adverse conditions in which they are required to perform. The conductors are drawn from bright electrolytic grade of 99.97%
pure copper. The wires are drawn, annealed & bunched together properly to ensure flexibility & uniform resistance.Each of the
three bunched conductors are insulated with high grade PVC compound which gives very high insulation resistance values. The
insulated cores are laid up in flat parallel position. The outer sheathing is provided with specially formulated PVC compound (Type
ST-1), which has high resistance to soil & chemical. Thus the cable remains flexible even after years in soil. SBEE submersible 3
core flat cables are now available with sequential marking, brand name, size and voltage printed on them.
IS 694:1990
Copper Conductor
PVC Insulation of
Cores (Red, Yellow, Blue)
CM/L 6139768
W
Table for 3 core flat cables use for submersible pump motors conforming to IS-694-1990.
Technical specification
Conductor
Number/
size of wire
No/mm
Area in
Sq. mm
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
14/0.3
22/0/3
36/0.3
56/0.3
84/0.3
140/0.3
226/0.3
354/0.3
495/0.3
703/0.3
360/0.5
475/0.5
Insulation
Thickness
(Nom)
0.6
0.6
0.7
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
Sheath
Thickness
(max)
Width
W
Height
T
Conductor
Max. Resistance
0
@ 20 C
Current Capacity
@ 400C
mm
mm
mm
mm
Amps
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.5
1.6
1.7
2.0
2.4
10.5
11.5
14.0
16.5
18.0
22.5
26.5
32.5
36.0
41.5
51.0
58.0
5.0
5.4
6.4
7.2
8.0
9.6
11.0
13.5
15.0
17.0
20.0
23.0
19.5
13.3
7.98
4.95
3.30
1.91
1.21
0.78
0.554
0.386
0.272
0.206
11
14
18
26
31
42
57
75
110
135
195
225
5.0
7.5
10.0
12.5
15.0
17.5
20.0
25.0
30.0
35.0
40.0 45.0
50.0 55.0
60.0
65.0 70.0
75.0
AMP
7.5
11.0 14.9
18.9
22.5
25.2
28.4
37.5
45.0
52.4
60.0 67.5
75.0 82.5
90.0
Derating factors: Multiply the current carrying capacity of the cable by factors given below for various ambient
temperatures
0
Ambient Temperature C
Derating Factor
10
30
35
40
45
50
1.09
1.04
1.00
0.95
0.9
80.0
120.0
Non-Cross
sectional
Area
Minimum Insulation
Thickness
mm
mm
mm
Polyester &
Polypropylene
0.40
0.45
0.50
0.55
0.60
0.65
0.70
0.75
0.80
0.90
0.95
1.00
1.10
1.20
1.30
1.40
1.50
1.60
1.70
1.80
1.90
2.00
2.10
2.20
2.30
2.40
2.50
2.60
2.70
2.80
2.90
3.00
0.125
0.159
0.196
0.238
0.283
0.332
0.385
0.442
0.502
0.638
0.709
0.785
0.850
1.130
1.330
1.540
1.770
2.010
2.270
2.540
2.840
3.140
3.460
3.800
4.150
4.520
4.910
5.310
5.730
6.154
6.610
7.07
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.20
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
HR PVC
0.25
0.25
0.25
0.25
0.25
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.35
0.35
0.35
0.35
0.35
0.35
0.45
0.45
0.45
0.45
0.50
0.50
0.50
0.50
0.55
0.55
0.55
Approximate Overall
Diameter
mm
MAX
Polyester &
Polypropylene
0.80
0.85
0.90
0.95
1.00
1.05
1.10
1.15
1.20
1.30
1.35
1.40
1.50
1.60
1.70
1.90
2.00
2.10
2.20
2.30
2.40
2.50
2.60
2.70
2.90
3.00
3.10
3.20
3.30
3.40
3.50
3.60
HR PVC
1.05
1.1
1.15
1.2
1.25
1.35
1.45
1.5
1.55
1.65
1.70
1.75
1.85
1.95
2.05
2.25
2.35
2.45
2.55
2.70
2.80
3.10
3.20
3.30
3.40
3.60
3.70
3.80
3.90
4.10
4.20
4.30
Maximum
Conductor
Resistance
0
@ 20 C
Ohms/Km
140
112
89.6
74.7
62.2
53.5
45.7
40.2
35.0
27.6
25.1
22.4
18.5
15.5
13.2
11.4
9.95
8.75
7.75
6.91
6.20
5.60
5.08
4.63
4.23
3.89
3.58
3.31
3.07
2.86
2.66
2.49
Conductor
Elongation
Maximum
Range of
Motors for
which
Normally
Suited
%
24
25
25
26
26
28
28
28
28
29
30
30
30
31
32
32
32
32
32
32
32
33
33
33
33
33
33
34
34
34
34
34
HP
1 To 1.5
1 to 1.5
1.5 to 2
1.5 to 2
2 to 3.5
2 to 3.5
2 to 3.5
2 to 3.5
4 to 5
4 to 5
4 to 5
5 to 10
5 to 10
10 to 20
10 to 20
10 to 20
10 to 20
20 to 30
20 to 30
20 to 30
20 to 35
20 to 35
20 to 35
35 to 75
35 to 75
35 to 75
35 to 75
35 to 75
Above 75
Above 75
Above 75
Above 75
NOTE: All data given in this catalogue is approximate and are subject to manufacturing tolerance
Delivery length tolerance 5% length more than normal as per customer request.
All figures given in various tables are indicative only.
11
Dealer