Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

STANDARDS:

SNCF CT 445
NF F 55-698
NF C 32070 Category C2 / IEC 60332-1-2
NF C 32070 Category C1 (optional)
1.- CONDUCTOR:
Solid Copper conductor 1mm
2
(Optional: 1.5 mm
2
).
2.- INSULATION:
Solid polyethylene.
3.- PAIRS:
Two twisted conductors that form a pair.
4.- INNER SHEATH:
Inner waterproof sheath (Halogen-Free optional).
5.- SCREEN:
Corrugated Copper tape, anti-inductive.
6.- INTERMEDIATE SHEATH:
Polyetylene separating layer.
7.- ARMOUR:
Two helically applied steel tapes.
8.- OUTER SHEATH:
PVC outer sheath (Halogen-Free optional)
Used for signalling circuits in railway networks.
Connects the singalling equipment centre to the track-side equipment.
Low reduction factor.
Use and storage temperature: -30C to 70C
Mineral oil resistant.
CONSTRUCTION:
APPLICATIONS AND MAIN CHARACTERISTICS:
ZPAU
Railway Control and Signalling cables.
Voltage 750 V
1
2
3
4
5
6
7
8
CUSTOMER SERVI CE
TEL.:+34 932 279 700
FAX: +34 900 210 486
www.generalcable.es
ZPAU
Railway Control and Signalling cables.
Voltage 750 V
PHYSICAL CHARACTERISTICS:
CODE NUMBER CONDUCTOR AVERAGE OU- WEIGHT MINIMAL BEN- DELIVERY
OF PAIRS DIAMETER TER DIAMETER DING RADIUS LENGTH
mm mm kg/km mm m*
6801045 4 1.13 19.5 630 260 1000
6801075 7 1.13 22.5 795 300 1000
6801145 14 1.13 27.5 1440 360 500
6801215 21 1.13 31.5 1420 410 500
6801285 28 1.13 35.0 1730 460 500
6801565 56 1.13 48.5 3190 510 500
*Other packaging on request.
Optional versions ZPAU 2p x 1 mm
2
, 2p x 1.5 mm
2
and 1p x 2.5 mm
2
are available for specific networks.
2p cables assembly: star quad.
ELECTRICAL CHARACTERISTICS:
PARAMETER VALUE UNIT
Linear resistance 18.1 /km
Insulation resistance 5000 M.km
Dielectric strength, DC voltage applied during 3 min
between conductors 4.5 kV
Mutual capacitance at 800 Hz 55 nF/km
Capacitance unbalance 400 pF/500m
Characteristic impedance
-from 20 to 45 kHz: 120 10
-from 45 to 80 kHz: 115 10
Linear attenuation
-from 20 to 45 kHz: 2.5 dB/km
-from 45 to 80 kHz: 3 dB/km

INDUCTION PROTECTION:
Inductive Voltage
(V/km) 28 32 37 42 47 54 70 80 100 120 170 225
Reduction Factor
at 50Hz 0.75 0.70 0.60 0.50 0.40 0.35 0.30 0.28 0.26 0.24 0.25 0.25

You might also like