Professional Documents
Culture Documents
Astm d3686 - 13 Covs Aire
Astm d3686 - 13 Covs Aire
sCV
A1DE
d
2
1sCV
S
d
2
1sCV
P
d
2
where:
CV
A1DE
= coefficient of variation of a single future assay including error in the desorption efficiency factor
CV
S
= coefficient of variation due to sampling errors (not including variation of the pump) along with variability in true desorption efficiency from tube-to-tube, and
CV
P
=
coefficient of variation due to pump (CV
P
= 0.05 assumed).
G
Sampling rates of less than 10 mL/min are not recommended. Shorter sampling periods are required.
REFERENCES
(1) Second NIOSH Solid Sorbents Roundtable , Ed. E. V. Ballou, 1976,
NIOSH Publication No. 76193.
(2) White, L. D., Taylor, D. G., Mauer, P. A., and Kupel, R. E., A
Convenient Optimized Method for the Analysis of Selected Solvent
Vapors in the Industrial Atmosphere, American Industrial Hygiene
Association Journal, Vol 31, 1970, pp. 225232.
(3) Otterson, E. J., and Guy, C. U., A Method of Atmospheric Solvent
Vapor Sampling on Activated Charcoal in Connection with Gas
Chromatography, Transactions of the 26th Annual Meeting of the
American Conference of Governmental Industrial Hygienists,
Philadelphia, 1964, pp. 3746.
(4) Reid, F. H., and Halpin, W. R., Determination of Halogenated and
Aromatic Hydrocarbons in Air by Charcoal Tube and Gas
Chromatography, American Industrial Hygiene Association Journal,
July-August 1968, pp. 390396.
(5) Turner, B. C., and Glotfelty, D. E., Field Sampling of Pesticide
Vapors with Polyurethane Foam, Analytical Chemistry, Vol 49, 1977,
pp. 710.
(6) Taylor, D. G., Kupel, R. E., and Bryant, J. M., Documentation of
NIOSH Validation Tests, DHEW (NIOSH), Pub. No. 77-185. Avail-
able from National Technical Information Service, Springeld, VA
22161 (PB274-248).
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every ve years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.astm.org/
COPYRIGHT/).
D3686 13
7
Copyright by ASTM Int'l (all rights reserved); Thu Jan 2 14:55:20 EST 2014
Downloaded/printed by
Jorge Gonzales (INSPECTORATE SERVICES PERU S.A.C.) pursuant to License Agreement. No further reproductions authorized.