Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 2

Date Section Depart.

CIMENTO NACIONAL LDA


Basic Maintenance programme
Form No:Main /ML/4/000
Issue: 1
Page: 1of1 Cement
Mill
Mech
Eqpt. No. & Name /
Description of activities
S
t
a
t
u
s
L
u
b
.
/
m
a
i
n
Frequency
O
t
h
e
r
s
Instruction Remark
B F Fan,

R/S L/M D W F M 3M 6M Y O
1. Clean the machine & its surrounding S M O
2. Check the bearing housing for leaks R M O
3. Check the temp. of both bearings R M O ma!" 12#
o
c
Dri$e side%%%%&on D.S%%%%
'. Check the $ibration le$el is normal R M O (ma!" )mm*s
Dri$e side%%%%&on D.S%%%%
+. Check oil le$el R , O Oil t-pe. Mobil gear )2/
Dri$e side%%%%&on D.S%%%%
). 0rease the bearing seals R , O 0rease t-pe. 12324 till it protrudes
from the shaft 5#2 pts on each side6
Dri$e side%%%%&on D.S%%%%
/. 7nspect the casing of the fan R M O
8. 7nspect the blades for 9ear4 cracks and
material caking
S M O During o$erhaul period
:. Check the condition of the shaft4 bolts
& other mechanical parts
S M O ,oose4 bend structure4 etc
5During o$erhaul period6
1#. Change lubrication oil S , O
Oil t-pe. Mobil gear )2/4;t-. '2. 2,
11. 7nspect the suction & deli$er-
e!pansion <oints
R M O
12. Check cooling discs for loose bolts S M O
13.Check cooling disc guard for clogging*
air flo9
R M O Clean if clogged
1'. Check manholes* bolts* leakages R M O
1+. Check condition of bearings S M O
* Coupling (Type
1.Check the clearance*gap bet9een the
coupling hal$es
R M O Std " )=12mm
>ctual"%%%%%%%%%%%
2.Check the plastic fle!ibles for 9ear
5Circumferential backlash6
S M O Std " 1/.+mm
>ctual"%%%%%%%%%%%
3.Check all fasteners 5for tightness6 S M O
Legend: R = Running S = Stop Planning cell Entered in Record Sign.
D = Daily W = Weekly F = Fortnightly Sign. Name
M = Monthly Y = Yearly Name Prepared by Checked by

You might also like