Spesifikasi Teknis Automatic Water Trement Plant Kapasitas 15 Mesin HD

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

SPESIFIKASI TEKNIS AUTOMATIC WATER TREMENT PLANT

KAPASITAS 15 MESIN HD

1. RAW WATER TANK
Jumlah : 1 (satu) unit
Merk : Exel / Profil / Setara
Kapasitas : 1.000 liter
Material : PE
2. POMPA FILTER
Jumlah : 1 (satu) unit
Merk : Grundfos / setara
Kapasitas : 40 Lpm
Total Head : 50 Meter
System : Automatic Pressure Switch
3. ORGANIC REMOVAL FILTER
Jumlah : 1 (satu) unit
Type : ORF 09 A
Media Filter : Carbon Active
Volume : 1 cuft
Dimensi : Dia.09 x 48
Bahan tabung : FRP
System : Automatic Backwash
4. SOFTENER FILTER
Jumlah : 1 (satu) unit
Type : SO09A
Media Filter : Cation Resin
Volume : 1 cuft
Dimensi : Dia.09 x 48
Bahan tabung : FRP
System : Automatic Backwash (Autotrol merek Osmonic)
Accessories
1 unit chemical tank
1 unit ejector
5. R.O SYSTEM (REVERSE OSMOSIS SYSTEM)
Jumlah : 1 (satu) unit
Type : 4500
Total kapasitas max : 4500 GPD
Tekanan Mininum : 20 80 psi
Tekanan Operasi : 200 psi
Total Membrane : 3 (tiga) unit
Motor : 1 - 2 HP
STANDART FEATURES
Painting Steel Bracket
Low Pressure Switch
Liquid Filled Pressure Gauge
Pre Filter Gauge
Thin Film Composite Membrane
SS Membrane Housing
( 1 x 20 ) 5 micron sediment Cartridge filter
S.S Waste & Recycle Fixed Flow Control
Automatic Flushing System
SS High pressure pump
6. PRODUCT TANK
Jumlah : 1 (satu) unit
Merk : Exel / Profil / Setara
Kapasitas : 2.000 liter
Material : PE
7. POMPA DISTRIBUSI
Jumlah : 1 (satu) unit
Merek : Grundfos
Daya dorong : 50 meter
Material : Stainlees Steel
8. PANEL CONTROL
Jumlah : 1 (satu) unit
Type : In door
9. ULTRAVIOLET SYSTEM
Jumlah : 1 (satu) unit
Merk : Steriligth
Kapasitas : 12 gpm
Original : Canada
10. CONSUMABLE RO
Meliputi : Cartridge 5 micron 20 BB jumlah 6 pcs
NaCl jumlah 48 kantong
11. ANALISA AIR STANDAR AAMI (1 x)
Jumlah : 1 (satu) kali dalam 1 tahun (commissioning)
Standar parameter : AAMI
Laboratorium : Unilab
12. PIPING, ENGINEERING & COMMISSIONING (Dalam System)
Jumlah : Lumsum
Meliputi : Pipa, Valve, Fitting, Support, Design Engineering,
Test Running & Commissioning, Instruction Manual
Book dan Training Operator