Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

Aspen Flare System Analyzer V8.

0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Network
Name Location Upstream
Node
Downstream
Node
Ignored Tailpipe Length
(ft)
Stack Con 1 Tip No No 19,685
BDLINE 2 RO Con 1 No No 100,001
BDLine 1 BDV RO No No 10,000
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 1 of 5
Printed At 19/09/2013 10:30:35
Aspen Flare System Analyzer V8.0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Network
Name Elevation
Change
(ft)
Material Roughness
(in)
Thermal
Conductivity
(Btu/hr-ft-F)
Nominal
Diameter
Schedule Internal
Diameter
(in)
Wall
Thickness
(in)
Stack 19,685 Carbon Steel 0,00180 29,99 4 inch 40 4,026 0,237
BDLINE 2 0,000 Carbon Steel 0,00180 29,99 4 inch 40 4,026 0,237
BDLine 1 0,000 Carbon Steel 0,00180 29,99 2 inch 160 1,687 0,344
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 2 of 5
Printed At 19/09/2013 10:30:35
Aspen Flare System Analyzer V8.0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Network
Name Pipe
Class
Sizeable Length
Multiplier
Fittings
Loss A
Fittings
Loss B
Ambient
Temperature
(F)
External Medium
Velocity
(ft/s)
Insulation
Description
Insulation
Thickness
(in)
Stack No No 0,000 0,000 Glass Fibre 0,00
BDLINE 2 No No 0,000 0,000 Glass Fibre 0,00
BDLine 1 No Yes 0,000 0,000 Glass Fibre 0,00
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 3 of 5
Printed At 19/09/2013 10:30:35
Aspen Flare System Analyzer V8.0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Network
Name Insulation
Conductivity
(Btu/hr-ft-F)
Outlet
Temperature
(F)
Duty
(Btu/hr)
VLE
Method
Horizontal
Pres. Drop
Inclined
Pres. Drop
Stack 0,023 0,000e+000 Model Default Model Default Model Default
BDLINE 2 0,023 0,000e+000 Model Default Model Default Model Default
BDLine 1 0,023 0,000e+000 Model Default Model Default Model Default
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 4 of 5
Printed At 19/09/2013 10:30:35
Aspen Flare System Analyzer V8.0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Network
Name Vertical
Pres. Drop
Two Phase
Elements
Friction
Factor
Damping
Factor
Stack Model Default Model Default
BDLINE 2 Model Default Model Default
BDLine 1 Model Default Model Default
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 5 of 5
Printed At 19/09/2013 10:30:35
Aspen Flare System Analyzer V8.0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Scenario : BDV Only
Pressure/Flow Summary(Velocities Based Upon Nominal Flows)
Name Mass
Flow
(lb/hr)
Molar
Flow
(lbmole/hr)
Rated Mass
Flow
(lb/hr)
Static Pressure
Drop
(psi)
Noise
(dB)
Static Source
Back Pressure
(psig)
Stack 42000,0 2252,90 42000,0 17,02995 76,9
BDLINE 2 42000,0 2252,90 42000,0 41,78980 74,5
BDLine 1 42000,0 2252,90 42000,0 37,21865 44,8 757,11308
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 1 of 6
Printed At 19/09/2013 10:30:35
Aspen Flare System Analyzer V8.0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Scenario : BDV Only
Pressure/Flow Summary(Velocities Based Upon Nominal Flows)
Name Upstream
Static Pressure
(psig)
Upstream
Temperature
(F)
Upstream
Velocity
(ft/s)
Upstream
Mach No.
Upstream
Rho V2
(lb/ft/s2)
Upstream
Enthalpy Flow
(btu/hr)
Stack 50,28714 109,97 661,525 0,477 87302 1,055e+007
BDLINE 2 92,07694 109,97 400,884 0,290 52905 1,055e+007
BDLine 1 757,11725 109,97 294,196 0,220 221121 1,055e+007
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 2 of 6
Printed At 19/09/2013 10:30:35
Aspen Flare System Analyzer V8.0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Scenario : BDV Only
Pressure/Flow Summary(Velocities Based Upon Nominal Flows)
Name Downstream
Static Pressure
(psig)
Downstream
Temperature
(F)
Downstream
Velocity
(ft/s)
Downstream
Mach No.
Downstream
Rho V2
(lb/ft/s2)
Downstream
Enthalpy Flow
(btu/hr)
Stack 33,25719 109,98 898,027 0,647 118513 1,055e+007
BDLINE 2 50,28714 109,98 661,527 0,477 87302 1,055e+007
BDLine 1 719,89861 109,98 257,713 0,211 193700 1,055e+007
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 3 of 6
Printed At 19/09/2013 10:30:35
Aspen Flare System Analyzer V8.0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Scenario : BDV Only
Pressure/Flow Summary(Velocities Based Upon Nominal Flows)
Name Flow
Regime
Static Pipe
Friction Loss
(psi)
Static Pipe
Accel. Loss
(psi)
Static Pipe
Elevation Loss
(psi)
Static Pipe
Fittings Loss
(psi)
Friction
Factor
Stack Single Phase/Single Phase 0,00000 0,01639
BDLINE 2 Single Phase/Single Phase 0,00000 0,01639
BDLine 1 Single Phase/Single Phase 0,00000 0,01996
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 4 of 6
Printed At 19/09/2013 10:30:35
Aspen Flare System Analyzer V8.0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Scenario : BDV Only
Pressure/Flow Summary(Velocities Based Upon Nominal Flows)
Name Reynolds
Number
Duty
(Btu/hr)
Overall
HTC
(Btu/h/ft2/F)
External
Convective HTC
(Btu/h/ft2/F)
External
Radiative HTC
(Btu/h/ft2/F)
Internal
HTC
(Btu/h/ft2/F)
Stack 5652540 0,000e+000
BDLINE 2 5876223 0,000e+000
BDLine 1 13237323 0,000e+000
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 5 of 6
Printed At 19/09/2013 10:30:35
Aspen Flare System Analyzer V8.0 - aspenONE
Version 27.0.0.35
User Name : A. User
J ob Code : Documentation
Project : Flarenet
Description : Simple Convergent System With 4 Scenarios Design
Scenario : BDV Only
Pressure/Flow Summary(Velocities Based Upon Nominal Flows)
Name Wall
Temperature
(F)
External
Temperature
(F)
Equivalent
Length
(ft)
Physical
Length
(ft)
Stack 19,69 19,685
BDLINE 2 100,00 100,001
BDLine 1 10,00 10,000
D:\J ambi merang\Calculation\Depressuring\flarenet\1B 6inch test.fnwx Page 6 of 6
Printed At 19/09/2013 10:30:35

You might also like