CONSOLIDATION TEST

Project
Location
Boring No.
Depth

:
:
:
:

NIRWANA AGRO LESTARI


Lab. Ref.
LAMANDAU, CENTRAL KALIMANTAN
Date Tested
BH-2
Cc
2.50-2.80 M
Pc

: 110-01-0709
:
:
:

kN/m

1.00

0.90

VOID RATIO

0.80

0.70

0.60

0.50
1

10

100

1000

10000

10

100

1000

10000

Cv (x 10-3)cm/sec.

8.00
6.00
4.00
2.00
0.00
APPLIED PRESSURE (kN/m)

10
20
40
80
160
320
640
1280
320
80
20
10

397.0
393.5
388.0
378.0
363.0
337.0
305.0
262.0
272.0
283.0
293.0
298.0

0.0030
0.0065
0.0120
0.0220
0.0370
0.0630
0.0950
0.1380
0.1280
0.1170
0.1070
0.1020

0.9970
0.9935
0.9880
0.9780
0.9630
0.9370
0.9050
0.8620
0.8720
0.8830
0.8930
0.8980

0.907
0.901
0.890
0.871
0.842
0.793
0.731
0.649
0.668
0.689
0.708
0.718

375.0
470.4
375.0
470.4
437.4
405.6
375.0
470.4

3.636
2.880
3.580
2.810
2.945
3.043
3.094
2.270

CONSOLIDATION TEST

Lab. Ref. :
Project :
Location :
Boring No. :
Depth :
Soil Description

099-01-0709
CRUDE OIL TANK
BALONGAN, WEST JAVA
BH-9
10.00-10.50 M
:

Test Started :
Test Completed :
Data poltted By:
Checked By :

Moisture & Density Data :


============= ============= ================ ================ ============= ================ ================
INITIAL
FINAL
============= ============= ================ ================ ============= ================ ================
Sample Height (Ho)
(cm)
2.000
1.292
Sample Diameter (Do)
(cm)
6.000
6.000
Sample Area (Ao)
(cm2)
28.26
28.26
Sample Volume (Vo)
(cm3)
56.52
36.51
Wt. of Ring + Wet Soil
Wt. of Ring only
Wt. of West Soil
Wet Density

(gr)
(gr)
(gr)
(gr/cm3)

219.0
132.8
86.2
1.525

200.8
132.8
68.0
1.862

Wt. of Soil + Dish


Wt. of Dry Soil + Dish
Wt. of Lost Moisture
Wt. of Dish No.
Wt. of Dry Soil
Moisture as % of Dry Wt.
Dry Density

(gr)
(gr)
(gr)
(gr)
(gr)
(%)
(gr/cm3)

259.0
167.2
91.8
32.6
134.6
68.20
0.906

96.5
79.7
16.8
28.5
51.2
32.73
1.403

Specific Gravity
2.69
Degree of Saturation S
(%)
93.23
96.01
============= ============= ================ ================ ============= ================ ================
Height of Solid (Hs)
0.674
============= ============= ================ ================ ============= ================ ================
Void Ratio Computation :
============= ============= ================ ================ ============= ================ ================
Load
Dial
Settlement
Height of
Void Ratio
T90
Cv
(kN/m2)
Reading
dH(cm)
Sample (cm)
(e)
(Sec)
(X10-3)cm2/sec
============= ============= ================ ================ ============= ================ ================
0.0
1000.0
2.0000
1.968
10
937.0
0.0630
1.9370
1.874
735.0
1.118
20
889.0
0.1110
1.8890
1.803
540.0
1.437
40
838.5
0.1615
1.8385
1.728
653.4
1.127
80
750.0
0.2500
1.7500
1.597
653.4
1.045
160
612.0
0.3880
1.6120
1.392
576.6
1.039
320
495.0
0.5050
1.4950
1.218
653.4
0.783
640
365.0
0.6350
1.3650
1.026
614.4
0.706
1280
186.0
0.8140
1.1860
0.760
614.4
0.561
320
218.0
0.7820
1.2180
0.807
80
246.0
0.7540
1.2460
0.849
20
280.0
0.7200
1.2800
0.899
10
292.0
0.7080
1.2920
0.917

============= ============= ================ ================ ============= ================ ================