Dead Legs Biocide Treatment Week 01-07-07

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 1

DEAD LEGS BIOCIDE TREATMENT

Equipment/PID Location Line number


valve
TAG
Remarks
Done
Yes/no
DS300/ 1950 LV3002 by pass 6"PW400028 1
FE3000 by pass 8"GH300018 2 Not in Service
Drain header to closed drain 4"DF350001 3
Oil outlet to closed drain 1"DF350288 4
DS301/1951 Link water/oil outlet 6"GH300038 5
Sampling oil outlet 18"GH300040 6
Drain header to closed drain 4"DF350002 7
EC313/1953 (01/02) DS301 outlet to closed drain C523A-P 8
Outlet EC313A to closed drain 2"DF350211 9
1" EC313A body drain cold side 1" 10
Outlet EC313B to closed drain 2"DF350213 11
1" EC313B body drain cold side 1" 12
Outlet EC313C to closed drain 2"DF350215 13 Not in service (dismantle)
1" EC313C body drain cold side 1" 14
Outlet EC313D to closed drain 2"DF350217 15
1" EC313D body drain cold side 1" 16
EC313 A/B/C/D by bass cold side 16"GH300096 17
DS302/1953 (02/02) Link water/oil outlet 3"GH300071 18
Drain header to closed drain 4"GH300075 19 Pressure balanced by LG drain
GX310/1954 GX310A suction strainer drain 2"DF350080 20 If pump runs
GX310A discharge drain 2"DF350077 21 If pump runs
GX310A suction vent 1"GH310074 22 If pump runs
GX310B suction strainer drain 2"DF350080 23 If pump runs
GX310B discharge drain 2" 24 If pump runs
GX310B suction vent 1"GH310075 25 If pump runs
DS320A/1955(01/02) PDV3201A by pass 2" by pass 26
1"Drain of DS320A inlet 1"DF350292 27
3" drain of outlet water 4"PW320028 28
GX320 discharge to oily water package 4"PW400006 29
DS320B/1955(02/02) PDV3201B by pass 2" by pass 30
3" drain of outlet water 4"PW320016 31
EC321 by pass 4"PW320028 32 Not in service
Oily water U/S EC321 to open Drain 2"DO360079 33
Oily water to sand jet DS400 3"PW400058 34
Oily water to sample box 2"PW400042 35
1"Drain of DS320B inlet 3/4" 36
DS401( Vendor PID) Drain D/S LV4007 3/4" 37
Skimmed oil pipe GX400A discharge drain to closed drain 1"DF350244 38
GX400B discharge drain to closed drain 1"DF350245 39
DA350/1866 GX350A recirculation line 2"DF350222 40
GX350B recirculation line 2"DF350223 41
DEAD LEG WHILE DS 320B BY PASS
GX320: pump stopped
DS320B/1955(02) Mini flow GX320 2"PW320025 Not in Service
GX320 unavailable for long time Under Cleaning job
DS320A/1955(02) GX320A suction line 6"PW320016 Drain by 3/4"drain valve
GX320A discharge line 4"PW320018 Drain by 3/4"drain valve
GX320B suction line 6"PW320017 Drain by 3/4"drain valve
GX320B discharge line 4"PW320019 Drain by 3/4"drain valve
Instruction: Flush 2 hours after the beginning of biocide treatment
Location Pump Yes / No
DS300 GX827-3A
DS301 GX827-2A
DS302 GX827-1A
PSV3130A (or B) GX827-1A
DA350 GXTemporary
Suction
GX722/721A/B GX821-2A/2B
\\vboxsrv\conversion_tmp\scratch_3\[246831611.xls.ms_office.xls]Sheet1