Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1

2
3
4
5
6
8 9 10
11
12
13
14
15
16
7
17
KITCHEN
Laminated wooden flooring
BATHROOM1
Tiles
18,4m|
DRESSING ROOM
Laminated wooden flooring
19,5m|
MAIN BEDROOM
Laminated wooden flooring
17,4m|
LOUNGE AREA
Laminated wooden flooring
OPEN PLAN
DINNING AREA
OPEN PLAN
STUDY AREA
SCULLERY
Tiles
11m|
GUEST WC
Tiles
7,3m|
Bath
hwb
hwb
WC
sink WC
hwb
hwb
Sh
1
2
2
1
2 1
2
1
1 2
2 1
1
2
BIC
BIC
BIC
OPEN PLAN MAIN SPACE
Laminated wooden flooring
148,4m|
FRIDGE
W1 W1 W1 W1 W1 W1
W2 W2
W2 W3 W3 W4
D1 D1
D1
D1
D3
D1
D2
Existing window Existing window Existing window Existing window Existing window
Existing window Existing window Existing window Existing window
Existing window Existing window
Existing door Existing door
Existing door
ENTRANCE
D4
D4
Hob
Existing staircase
&balustrade
work top Island
900mmh
Existing window
2
2
2
2
s
D
B
d
2
2
2 2
2
2
2 2
2 2
2
2500
2
5
0
0
1796
2
7
9
5
1796
2
2
0
5
2
2
0
5
5593
755 2
1
6
0
2
2
8
5
3
1
6
2
1
0
5
0
9
6
9
3
9
9
1
2
6
6
1146 1122
9
5
2
1
0
1
8
1183 1352
2
5
0
5
1
3
2
7
482 2410
518
542
1
8
0
4
1585 1431
729 1197
1
9
0
7
1698
1473
1
5
4
7 4
7
2
7
7
1
6
1
3
0
4
0
1
9
6
0
1
5
0
0
0
3
6
0
2
2
0
3
0
1
1
0
3
8
2
1
7
5
4
3
2
1
7
5
2
6
2
8
7
5
1
3
2
5
3
6
0
1
9
6
0
19145
612 1400 439 1400 2085 1400 1515 1400 2709 1400 1515 1400 1870
360 4578 75 6190 270 2572 130 1149 3464
110
30
220
4
8
8
5
1
5
0
0
0
3
6
0
9
7
0
8
1
3
3
2
1
7
3
6
0
4
3
9
5
3
0
0
0
3
6
0
1
7
2
0
1
3
0
4
4
9
5
1
0
1
0
4
2
8
5
19145
1380 1370 1490 620 190 620 1500 860 1160 3432 860 2221 860 2581
1455 360 500 1455 250 1396 474 133 2807 4342 600
75
1370 474 220 2492 360 360
1515 1400
100 000
100 150
100 300
100 000
100 300
100 300
100 300
100 000
100 000
100 000
100 000
ELECTRICAL LAYOUT
S C A L E 1 : 5 0
N
PROJ ECT
DRAWI NG
REV:
REG NO:
DWG NO:
DATE:
REV DATE DESCRI PTI ON
* All work, including mechanical and electrical work, is to be done in accordance with the National Building Regulations.
* All materials and workmanship are to comply with the relevant S.A.B.S. codes.
* This drawing is to be deemed to include all that is required for and consistent with good building practice regardless of any
specific omissions.
* This drawing is not to be scaled. Figured dimensions are to be used. All dimensions are in millimetres unless otherwise stated.
* This drawing must be read in conjunction with all relevant drawings and specifications.
* All dimensions and levels must be checked on site by the Contractor before putting any work in hand.
* Any discrepancies on the drawings are to be brought to the Architects attention by the Contractor before putting
any work in hand.
* The Contractor must obtain the Architects written confirmation of any instructions which involve a variation to the
contract before putting that work in hand.
* All voids, suspended ceilings and partitions to be rodent-proofed in accordance with the Government rodent-proofing regulations.
* The Architects retain Copyright of this Drawing.
NOTES:
1:50
BACHELOR FLAT
ELECTRICAL LAYOUT
SCALE:
as is design
DRAWN BY
ADELE STEYNBERG
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
P
R
O
D
U
C
E
D
B
Y
A
N
A
U
T
O
D
E
S
K
E
D
U
C
A
T
IO
N
A
L
P
R
O
D
U
C
T
P R O D U C E D B Y A N A U T O D E S K E D U C A T I O N A L P R O D U C T
P
R
O
D
U
C
E
D
B
Y
A
N
A
U
T
O
D
E
S
K
E
D
U
C
A
T
IO
N
A
L
P
R
O
D
U
C
T

You might also like