Analysis of Axial Capacity of A Driven Pile Using Modified Enr Formula

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ANALYSIS OF AXIAL CAPACITY OF A DRIVEN PILE USING MODIFIED ENR FORMULA

(Version 3.0, Copyright 2005, Developed By: GeoSoftware Solutions, All Rights Reserved)
(Licensed to: XYZ Engineering, Inc. - Los Angeles, California)
PROJECT INFORMATION
Project Name
Project No.
Location
INPUT PARAMETERS
Pile Location
Pile Description
Type of Hammer
Hammer Description
Hammer Efficiency, e
Hammer Energy Rating, E
h
(foot-pounds)
Weight of Ram, W
r
(pounds)
Weight of Pile and Assembly, W
p
(pounds)
Coefficient of Restitution, n
Factor of Safety, FS 6.00
SUMMARY OF PILE DRIVING RECORDS
Pile
Location
Pile Cutoff
Elevation
(feet)
Specified
Tip Elev.
(feet)
EOD Pile
Blow Count
(blows/ft)
Actual
Tip Elev.
(feet)
Actual
Pile Length
(feet)
Estimated
Ultimate
Capacity
(kips)
Abut. 1, Pile #9 447.52 396.00 62.00 396.00 51.52 411
Abut. 1, Pile #4 447.52 396.00 68.00 396.00 51.52 437
Abut. 2, Pile #8 448.32 396.00 64.00 396.00 52.32 420
Abut. 2, Pile #4 448.32 396.00 58.00 396.00 52.32 393
REFERENCES:
Prepared By: ______________________________________________ Date: ____________________________
Reviewed By: ______________________________________________ Date: ____________________________
2. ENR (1965), "Michigan Pile Test Program Test Results are Released," Engineering News-Record, May 20, 1965, pp. 26-34.
1. Bowles, J.E. (1988), "Foundation Analysis and Design, 4th Edition," McGraw-Hill Inc., pp. 785-803.
Q Street Bridge
52644
Los Angeles, California
Abutment 1
PP 42 x 1.25, Nominal Resistance =700 kips
Drop hammer
Delmag D62-22
0.80
165,000.00
14,600.00
45,000.00
0.40
ENRCAP
Input & Output Sheet

You might also like