Maryland Transit Administration: Maryland Department of Transportation

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 170

Maryland

General Engineering Consultant Team


100 North Charles Street, 8th Floor
P: 410-244-6046
Baltimore, MD 21202
OF
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
g
f
-
b
a
r
b
a
r
a

h
e
n
r
y
\
d
0
1
3
1
9
9
6
\
1
0
4
2
p
T
I 8
0
0
1
.
D
G
N
1
2
/
1
2
/
2
0
1
3
CONTRACT NO.
DRAWING NO.
SHEET NO.
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
443
0
GRAPHIC SCALE
APPROVED: DATE:
VICINITY MAP
MARYLAND TRANSIT ADMINISTRATION
MARYLAND TRANSIT ADMINISTRATION
MARYLAND DEPARTMENT OF TRANSPORTATION
PRELIMINARY ENGINEERING

5000' 10000' 5000' 2500'
AS NOTED SCALE:
PURPLE LINE LIGHT RAIL TRANSIT SYSTEM
MONTGOMERY / PRINCE GEORGE'S COUNTIES LOCATION:







CONTRACT NO. T-1042-0220
DCN:






























T-1042-0220
FACILITIES ENGINEERING, ADA & SUSTAINABILITY DIVISION
43667
Facilities Engineering, ADA & Sustainability
ROBERT L. BURRIS, ASSISTANT MANAGER,
ADA DESIGN CERTIFICATION
DESIGN CERTIFICATION
OWNERS / DEVELOPER CERTIFICATION
MD. REGISTRATION NO.
PRINTED NAME
DESIGNER'S SIGNATURE DATE
DATE OWNER/DEVELOPER SIGNATURES
PRINTED NAME AND TITLE
STATE OF MARYLAND, DEPARTMENT OF THE ENVIRONMENT, COMPLIANCE INSPECTORS."
I HEREBY AUTHORIZE THE RIGHT OF ENTRY FOR PERIODIC ON-SITE EVALUATION BY
FOR THE CONTROL OF SEDIMENT AND EROSION BEFORE BEGINNING THE PROJECT.
AT A MARYLAND DEPARTMENT OF THE ENVIRONMENT APPROVED TRAINING PROGRAM
INVOLVED IN THE CONSTRUCTION PROJECT WILL HAVE A CERTIFICATE OF ATTENDANCE
WILL BE DONE PURSUANT TO THIS PLAN AND THAT ANY RESPONSIBLE PERSONNEL
"I/WE HEREBY CERTIFY THAT ALL CLEARING, CONSTRUCTION AND/OR DEVELOPMENT
WITH THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT (ADA).
"I HEREBY CERTIFY THAT THIS PLAN HAS BEEN DESIGNED IN ACCORDANCE
DATE DESIGNER'S SIGNATURE
MD. REGISTRATION NO.
PRINTED NAME
P.E. R.L.S. OR R.L.A. (CIRCLE)
P.E. R.L.S. OR R.L.A. (CIRCLE)
CERT. NO.
MANAGEMENT, RESPECTIVELY"
26.17.01 AND 26.17.02 FOR EROSION AND SEDIMENT CONTROL AND STORMWATER
116 AND SECTIONS 4-201 AND 215, AND THE CODE OF MARYLAND REGULATIONS (COMAR)
INCLUDING SUPPLEMENTS, THE ENVIRONMENT ARTICLE SECTIONS 4-101 THROUGH
CONTROL, THE 2000 MARYLAND STORMWATER DESIGN MANUAL, VOLUMES I AND II
THE MARYLAND STANDARDS AND SPECIFICATIONS FOR SOIL EROSION AND SEDIMENT
"I HEREBY CERTIFY THAT THIS PLAN HAS BEEN DESIGNED IN ACCORDANCE WITH
DECEMBER 2013
T-1042-0220
N
SUBMISSION
ENGINEERING
PRELIMINARY
2013.12.20.PE.01.P3 Draft RFP Reference Drawings-Vol.
495
495
495
95
1
95
29
N
E
W

H
A
M
P
S
H
IR
E

A
V
E
C
O
N
N
E
C
T
IC
U
T

A
V
E
W
I S
C
O
N
S
I N

A
V
E
B
A
L
T
-
W
A
S
H

P
K
Y
EAST WEST HWY
EAST WEST HWY
1
6
T
H

S
T
R
E
E
T
G
E
O
R
G
IA

A
V
E
UNIVERSITY BLVD
B
A
L
T
IM
O
R
E

A
V
E
K
E
N
IL
W
O
R
T
H

A
V
E
ANNAPOLIS ROAD
M
O
N
T
G
O
M
E
R
Y

C
O
U
N
T
Y
P
R
IN
C
E

G
E
O
R
G
E
'S

C
O
U
N
T
Y
P
R
IN
C
E G
EO
R
G
E'S C
O
U
N
TY
W
A
SH
IN
G
TO
N

D
C
W
ASH
IN
G
TO
N

D
C
M
O
N
TG
O
M
ER
Y C
O
U
N
TY

















































VOLUME 8 - YARDS AND SHOPS







8-00
YARD FACILITY
LYTTONSVILLE
& SHOP FACILITY
GLENRIDGE YARD





TI-8001
1

MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
1

G
E
C

M
a
s
t
e
r

C
A
D
D

F
i l e
s
\
S
u
b
m
i t
t
a
l s
\
0
0
2

-

P
r
e
l i m
i n
a
r
y

E
n
g
i n
e
e
r
i n
g
\
V
o
l u
m
e

0
8
\
1
0
4
2
p
G
N
8
0
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
443
0 2000 2000 4000
SCALE: 1"=2000
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these T-1042-0220
PRELIMINARY ENGINEERING
C
O
N
N
E
C
T
IC
U
T
A
V
E
N
U
E
JONES BRIDGE ROAD
W
IS
C
O
N
S
IN
A
V
E
N
U
E
US-29 COLESVILLE ROAD
W
A
Y
N
E
A
V
E
N
U
E
A
V
E
N
U
E
F
L
O
W
E
R
B
O
U
L
E
V
A
R
D
M
D
-1
9
3
U
N
IV
E
R
S
IT
Y
R
O
C
K
C
R
E
E
K
S
T
A

T
R
K

1

1
0
0
+
0
0
N
P
R
IN
C
E
G
E
O
R
G
E
S
C
O
U
N
T
Y
M
O
N
T
G
O
M
E
R
Y
C
O
U
N
T
Y
STATION
BETHESDA
STORAGE FACILITY
LYTTONSVILLE STATION
LYTTONSVILLE
CENTER STATION
SILVER SPRING TRANSIT
LIBRARY STATION
SILVER SPRING
STATION
MANCHESTER PLACE STATION
LONG BRANCH
ROAD STATION
PINEY BRANCH
LAKE STATION
CHEVY CHASE
STREET STATION
WOODSIDE/16TH
STATION
DALE DRIVE
M
D
2
1
2
R
IG
G
S
R
O
A
D
M
D-193 UNIVERSITY BOULEVARD
A
D
E
L
P
H
I R
O
A
D
MD-410 EAST WEST HIGHWAY
PARKWAY
PAINT BRANCH
K
E
N
IL
W
O
R
T
H
A
V
E
N
U
E
M
D
-2
0
1
P
A
R
K
W
A
Y
B
A
L
T
IM
O
R
E
-W
A
S
H
IN
G
T
O
N
M
D
-2
9
5
E
L
L
IN
R
O
A
D
ROAD
HARKINS
B
O
U
L
E
V
A
R
D
M
D
-1
9
3
U
N
IV
E
R
S
IT
Y
B
O
U
L
E
V
A
R
D
M
D
-6
5
0
N
E
W
H
A
M
P
S
H
IR
E
P
R
IN
C
E
G
E
O
R
G
E
S
C
O
U
N
T
Y
M
O
N
T
G
O
M
E
R
Y
C
O
U
N
T
Y
N
STATION
RIGGS ROAD
WEST CAMPUS STATION
ADELPHI ROAD/
STATION
CAMPUS CENTER
STATION
EAST CAMPUS
METRO STATION
COLLEGE PARK
STATION
M SQUARE
STATION
RIVERDALE PARK
STATION
BEACON HEIGHTS
STATION
NEWCARROLLTON
AND SHOP FACILITY
GLENRIDGE YARD
C
O
U
N
T
Y
P
R
IN
C
E
G
E
O
R
G
E
S
C
O
U
N
T
Y
M
O
N
T
G
O
M
E
R
Y
GLENRIDGE STATION
ANNAPOLIS ROAD/
S
T
A

T
R
K

1

9
6
3
+
1
4
TRANSIT CENTER STATION
TAKOMA/LANGLEY
DECEMBER 2013




GN-8001
2 AS SHOWN
KEY MAP

MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
1

G
E
C

M
a
s
t
e
r

C
A
D
D

F
i l e
s
\
S
u
b
m
i t
t
a
l s
\
0
0
2

-

P
r
e
l i m
i n
a
r
y

E
n
g
i n
e
e
r
i n
g
\
V
o
l u
m
e

0
8
\
1
0
4
2
p
G
N
8
0
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
DECEMBER 2013




GN-8002
3 NONE
GENERAL NOTES AND LEGEND

GENERAL NOTES
ADA SUMMARY
9. ALL EXISTING STORM DRAIN STRUCTURES, SEWER MANHOLES, UTILITY MANHOLES,
THE CONTRACTOR SHALL NOTE THE HISTORIC NATURE OF THE SURROUNDING COMMUNITY.
THE CONTRACTOR SHALL MAKE EVERY EFFORT TO MINIMIZE NOISE FROM CONSTRUCTION
"MISS UTILITY", 1-800-257-7777 AT LEAST 48 HOURS IN ADVANCE
PRIOR TO PERFORMING EXCAVATION OR GRADING AT ANY LOCATION, CONTACT
UNLESS OTHERWISE NOTED, ALL SAWCUTTING SHALL BE FULL DEPTH.
ANY DAMAGE TO EXISTING CURBING ADJACENT TO NEWPAVING SHALL BE REPAIRED
THE SAFETY OF THE GENERAL PUBLIC, COMMUTERS, AND EMPLOYEES OF THE
THE CONTRACTOR SHALL PERFORM ALL WORK IN A MANNER THAT WILL INSURE
EXCEPT WHERE SPECIFIED ON THE PLANS OR AS DIRECTED BY THE ENGINEER.
APPURTENANCES REMOVED DURING THE CONSTRUCTION TO FACILITATE HIS WORK,
THE CONTRACTOR SHALL BE RESPONSIBLE TO RESET ANY SIGN POST OR OTHER
ETC. SHALL BECOME THE CONTRACTORS PROPERTY UNLESS OTHERWISE NOTED ON
MATERIAL REMOVED DURING CONSTRUCTION INCLUDING ASPHALT, SIGNS, LIGHT POLES,
A SOIL STOCKPILE SUITABLE FOR FILL MATERIAL AND TOPSOIL CAN BE MAINTAINED
THE CONTRACTOR SHALL BE RESPONSIBLE FOR STAGING CONSTRUCTION SUCH THAT
SEEDING AND MULCH, UNLESS OTHERWISE NOTED ON THE PLANS.
ANY DISTURBED AREAS NOT PAVED OR LANDSCAPED SHALL RECEIVE 4" TOPSOIL,
NEGLIGENCE OR METHOD OF OPERATION SHALL BE MADE AT THE CONTRACTORS
REPAIRS TO UTILITIES OR PROPERTY DAMAGE AS A RESULT OF CONTRACTORS
NOTIFY ALL CONCERNED UTILITY OWNERS PRIOR TO GRADING OPERATIONS.
HIS OWN SATISFACTION PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL
THE BEST AVAILABLE RECORDS AND SHALL BE VERIFIED BY THE CONTRACTOR TO
THE EXISTING UTILITIES AND OBSTRUCTIONS SHOWN ON THESE PLANS ARE FROM
MEET THE FINISHED GRADE ELEVATION AS NOTED ON THE PLANS, UNLESS THESE
INLETS, VALVE BOXES, VAULTS, ETC. SHALL BE ADJUSTED BY THE CONTRACTOR TO
ACTIVITY ON-SITE.
20.
OR REPLACED IN KIND AT THE CONTRACTORS EXPENSE.
THE PLANS OR IN THE SPECIAL PROVISIONS.
CONTRACTOR, MTA, ETC.
OF THE PROPOSED WORK.
18.
19.
17.
16.
15.
14.
EXPENSE BEFORE PROCEEDING WITH CONSTRUCTION.
APPURTENANCES ARE ABANDONED UNDER THIS CONTRACT.
ON-SITE.
13.
12.
10.
11.
CONTRACTOR FROM HIS RESPONSIBILITY TO CONSTRUCT ALL FACILITIES WITHIN ADA
EXISTING WHERE APPLICABLE. IN NO CASE SHALL THIS REQUIREMENT RELIEVE THE
WITH THE PROPOSED DRAINAGE PATTERNS AS SHOWN ON THE PLANS, AND THOSE
THE PARKING LOT, AT ALL ENTRANCES, AND ALONG ALL CURB LINES IN ACCORDANCE
THE CONTRACTOR SHALL BE RESPONSIBLE TO GRADE FOR POSITIVE DRAINAGE WITHIN
TYPE AND INVERT OF DITCHES ARE NOTED ON THE PLANS. DITCHES WILL BE IN
THE LOCATION AND LENGTH OF DRAINAGE PIPE SHALL BE VERIFIED BY THE
BETWEEN INVERT ELEVATIONS NOTED ON THE PLANS. UNLESS INDICATED OTHERWISE
ALL DRAINAGE PIPES AND DITCHES SHALL BE CONSTRUCTED ON A UNIFORM GRADE
CONDITIONS ENCOUNTERED DURING INSTALLATION OF DRAINAGE STRUCTURES.
INLETS AND PIPES MAY BE MODIFIED AS DIRECTED BY THE ENGINEER TO MEET
ALL INVERT ELEVATIONS ARE APPROXIMATE. INVERT ELEVATIONS OF DRAINAGE
BASE TOPOGRAPHIC SURVEY INFORMATION FOR THIS CONTRACT WAS ESTABLISHED
IN FEET AND ARE BASED ON NAVD 1988 DATUM.
ARE SHOWN ON THE PLANS. ALL ELEVATIONS ARE
THE LOCATION AND ELEVATION OF BENCH MARKS
STATE PLANE COORDINATE SYSTEM NAD 83/91.
THIS PROJECT IS ORIENTATED TO THE MARYLAND
4.
ACCORDANCE WITH THE DETAILS SHOWN ON THE PLANS.
CONTRACTOR BEFORE ORDERING.
ON THE PLANS OR DETAILS.
REGULATIONS.
8.
7.
6.
5.
VERTICAL CONTROL:
3.
2.
HORIZONTAL CONTROL: 1.
A COPY OF THE CONTRACTORS SITE SPECIFIC PROJECT SAFETY PLAN SHOULD BE SUBMITTED
TO THE OFFICE OF SAFETY & RISK MANAGEMENT (OSRM) FOR REVIEWAND COMMENT. A COPY
SHOULD BE FORWARDED TO DENNIS RAFFERTY/DAVID AUCHU IN THE OFFICE OF SAFETY & RISK
21.
MANAGEMENT. THE CONTRACTOR SHALL NOT BEGIN ANY WORK ACTIVITIES ON SITE UNTIL THE
PROJECT SAFETY PLAN HAS BEEN REVIEWED AND FOUND TO BE ACCEPTABLE BY REPRESENTATIVES
FROM THE OSRM.
REFER TO ADA GENERAL NOTES SHEET
FROM AERIAL PHOTOGRAMMETRIC MAPPING IN MARCH OF 2007. SUPPLEMENTAL FIELD SURVEYS
WERE PERFORMED AND PLOTTED BY PINNACLE MAPPING TECHNOLOGIES IN MARCH OF 2007.
22.
STATIONING KEY
L
L
TRK 2 300+00 TRK 2 301+00
(WESTBOUND)
C TRACK 2
(EASTBOUND)
C TRACK 1
TRK 2 302+00
TRK 1 300+00 TRK 1 301+00 TRK 1 302+00
LEGEND - EXISTING
LEGEND - PROPOSED
EXISTING BUILDING
EXISTING RIGHT OF WAY
EXISTING SIDEWALK
PROPOSED CATENARY POLE
PROPOSED IMPROVEMENTS BY OTHERS
PROPOSED CONCRETE
PROPOSED BUILDING DISPLACEMENT
EXISTING WETLAND BOUNDARY
PROPOSED TRAFFIC SIGNAL
EXISTING TRAFFIC PATTERN
PROPOSED TRAFFIC PATTERN
EXISTING TRAFFIC SIGNAL TO REMAIN
EXISTING TRAFFIC SIGNAL TO BE REMOVED
EXISTING ACTIVE RECOVERY WELL IN LOWER ZONE
EXISTING ACTIVE RECOVERY WELL IN UPPER ZONE
EXISTING LEFT TURN ELIMINATED WITH PROPOSED IMPROVEMENTS
PROPOSED BUMPING POST
PAVEMENT REMOVAL
PERMEABLE PAVEMENT
PROPOSED FULL DEPTH ASPHALT PAVEMENT
OR MILL AND OVERLAY
PROPOSED WEDGE/LEVEL
BY-OTHERS
TO BE DEVELOPED IN FINAL DESIGN.
REPRESENTATION ONLY. AS-DESIGNED SUPPORT LAYOUTS AND CONFIGURATIONS
OCS SUPPORT LOCATIONS ARE PRESENTED ON THE CIVIL PLANS FOR GRAPHICAL
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
SS
L A OU N T E C
141
140
27" RCP
SD
E G SD SS T W
DI
CC
C&G
PT. 10
TRAV
BM
TB 18
TP 22
8" W W.M. W
12" G
G
SS
T
JB
E.M.
FH W
CO
POLE NO.
JB
HBX
8" S
WALL
WM WV
WV
GV
#500
103.1
140
141 L P L P
W
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
1

G
E
C

M
a
s
t
e
r

C
A
D
D

F
i l e
s
\
S
u
b
m
i t
t
a
l s
\
0
0
2

-

P
r
e
l i m
i n
a
r
y

E
n
g
i n
e
e
r
i n
g
\
V
o
l u
m
e

0
8
\
1
0
4
2
p
G
N
8
0
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
DECEMBER 2013




GN-8003
4 NONE
CIVIL ABBREVIATIONS AND SYMBOLS

SYMBOLS ABBREVIATIONS
A102
2
SCALE:
REF: A105
1"=30
DETAIL 1
A
A102
SECTION
SCALE:
REF: A105
1"=30
CONCRETE GUTTER CG
COMBINED SEWER
CORR. GALVANIZED STEEL PIPE
CORRUGATED METAL PIPE
CENTER TO CENTER
CEMENT TREATED BASE
CURB AND GUTTER
CONSTRUCTION
CROSSOVER TRACK
DUCTILE IRON PIPE
EDGE OF STREAM
EDGE OF ROAD
EDGE OF PAVEMENT
FUTURE TRACK
FR
F/T
FT,
EB
EMB
FG
FL
FRAME
FOOT, FEET
EASTBOUND
EMBANKMENT
FINISH GRADE
FLOOR, FLOWLINE
C/T
EASEMENT ESMT
E/S
ELEC
EXIST
EXT
EL
E/R
E/P
ELECTRIC
EXISTING
EXTERIOR
ELEVATION
DWLG
DWG
EXP
DRWY
DIA
DIP
D/I
DWELLING
DRAWING
EXPANSION
DRIVEWAY
DIAMETER
DROP INLET
COL
CONN
C/C
C&G
CONST
L C
COLUMN
CONNECTION
CENTERLINE
CLR
COMB
CONC
CTB
CL
CGSP
CMP
CONCRETE
CLEAR
CLASS
ASPHALT CONCRETE
BITUMINOUS COATED CORRUGATED
CAST IRON PIPE
BITUMINOUS BIT
BASEMENT BSMT
CB
CO
CIP
CEM
BOT
CLEAN OUT
CATCH BASIN
CEMENT
BOTTOM
BLVD
BM
BRG
L B
BK
BLDG
BCCMP
BOULEVARD
BENCHMARK
BEARING
BASELINE
BUILDING
METAL PIPE
BACK
ASPH
APPROX
@
ABAN
ABUT
AGG
ASPHALT
APPROXIMATE
AT
ABUTMENT
ABANDONED
AGGREGATE
AHEAD
AC
N/F NOWOR FORMERLY
NORTH LINE-WEST TRACK
REINFORCED CONCRETE PIPE
PKG
PGL
PROP
RET
RCP
REQD
R/W
RT
RR
R
RIGHT OF WAY
RIGHT
RAILROAD
REQUIRED
PARKING
PROFILE GRADE LINE
PROPOSED
RETAINING
RADIUS
N/A
NTS
NO, #
N/W
NB
NIC
OUTSIDE DIAMETER
PEDESTRIAN
PROPERTY LINE
PERFORATED
PAVEMENT
NOT APPLICABLE
NOT IN CONTRACT
NOT TO SCALE
NORTHBOUND
NUMBER
LEAD PLUG (SURVEY MONUMENT)
LP
MAX
MISC
MON
MPH
MSL
LRT
MH
MIN
LRV
LR
LPLG
LT
INV
ID
INT
LIGHT RAIL TRANSIT
LIGHT RAIL VEHICLE
MAXIMUM
MANHOLE
MISCELLANEOUS
MONUMENT
MILES PER HOUR
MEAN SEA LEVEL
MINIMUM
LOWPOINT
INSIDE DIAMETER
INTERIOR
LONG RADIUS
LEFT
INVERT
GALV
GND
HORIZ
HP
H/W
H
IN, "
GR
GALVANIZED
HIGH POINT
HEAD WALL
HORIZONTAL
HEIGHT
INCH
GRADE
GROUND
VERTICAL
WESTBOUND
WAREHOUSE
WORK POINT
WEST
NEAR FACE
FAR FACE
STORM DRAIN
WATER SURFACE
POLYVINYL CHLORIDE
SD
PVC
FF
WHSE
WS
NF
WP
W
WB
VERT
SHEET
STRUCTURE
TEMPORARY
TOPOGRAPHY
TOP OF RAIL
TRACK
TYPICAL
UNDERDRAIN
TEST BORING
TOP OF CURB
TOP OF PAVEMENT
UNLESS NOTED OTHERWISE
VITRIFIED CLAY PIPE
TOP OF GROUND T/G
UNO
VCP
T/P
UD
TOPO
T/R
TYP
TRK
TEMP
TB
T/C
STR
SHT
SHOULDER
STEEL
STANDARD
SIDE WALK
STATION
SANITARY
SECTION
SOUTHBOUND
SHLD
STL
SW
SAN
SB
STA
STD
SECT
HIGH WATER
PARCEL NUMBER
CUT SLOPE - TOP
FILL SLOPE - TOE
SWALE
DITCH
RIGHT-OF-WAY
STRUCTURE OUTLINE
MATCHLINE AND SECTION LINE
SURFACE FLOWDIRECTION
STORM DRAIN LINE
UNDERDRAIN LINE
CULVERT WITH HEADWALLS
SPOT ELEVATION
RAILROAD TRACKS
DROP INLET, CATCH BASIN OR DRAIN
WALLS
CLEANOUT
CSXT CSX TRANSPORTATION INCORPORATED
E
EA EACH
EQN EQUATION
HDPE HIGH DENSITY POLYETHYLENE
MTA
N NORTH
PGE PROFILE GRADE ELEVATION
S SOUTH
W/ WITH
W/O WITHOUT
X-ING CROSSING
X-OVER CROSSOVER
MARC MARYLAND RAIL COMMUTER
WMATA WASHINGTON METROPOLITAN AREA
TEL TELEPHONE
TRANSIT AUTHORITY
DEGREES
DEFL DEFLECTION
EQ EQUAL
EQL EQUILATERAL
LB POUND
MIN, MINUTE
N/E NORTH LINE - EAST TRACK
OD
PERMANENT
REF REFERENCE
REINF REINFORCED
SEC, " SECOND
S/E SOUTH LINE - EAST TRACK
S/W SOUTH LINE - WEST TRACK
SP SPACING
V VELOCITY
VAR VARIES
WAT WATER
POB
POE
POINT OF BEGINNING
POINT OF ENDING
EXISTING PROPOSED
CURRENT SHEET
DETAILS
DETAIL NO.
DETAIL TITLE
DRAWING SCALE
SECTION REFERENCE
SECTION LETTER
CURRENT SHEET
SECTION LETTER
CURRENT SHEET
SECTION TITLE
SECTION SCALE
SECTIONS
DRAWING REFERENCE
DETAIL NO.
CURRENT SHEET
2
A102
A
A102
CO
PK
PL
PERM
PED
PERF
PAVT
NEEDED
SIZE AS
MAJOR CONTOUR LINE
MINOR CONTOUR LINE
TEST BORING 18
WATER LINE
GAS LINE
SANITARY LINE
PROPERTY LINE
LIGHT POLE
UTILITY POLE
FIRE HYDRANT
CENTER LINE
BASE LINE
BL
METAL FENCE (CHAIN LINK)
ORNAMENTAL METAL FENCE
WOOD FENCE
27" RCP
M-1 MANHOLE (TYPE AS NOTED)
I-1
103.1 x
CONCRETE CURB
CONCRETE CURB AND GUTTER
TRAFFIC BARRIER
BILLBOARD OR LARGE SIGN
SIGNS - NON-TRAFFIC
SIGNS - TRAFFIC
OR
EL. EL.
PRIMARY HORIZONTAL CONTROL - TRAVERSE POINT
BENCH MARK
TEST PIT
OR
OVERHEAD TELEPHONE LINE
UNDERGROUND TELEPHONE LINE
UNDERGROUND ELECTRIC LINE
OVERHEAD ELECTRIC LINE
ELECTRICAL JUNCTION BOX
ELECTRIC METER
UNDERGROUND FIBER OPTIC LINE
OVERHEAD FIBER OPTIC LINE
FH
ITEM TO BE REMOVED R
EAST
DN DOWNSPOUT
GW GUY WIRE
HBX HAND BOX
HMA HOT MIX ASPHALT
I INLET
JB JUNCTION BOX
LOD LIMIT OF DISTURBANCE
LF LINEAR FEET
MARYLAND TRANSIT ADMINISTRATION
RP RAMP
SHA STATE HIGHWAY ADMINISTRATION
SIG SIGNAL
SWM STORMWATER MANAGEMENT
TP TEST PIT
TR SIG TRAFFIC SIGNAL
WM WATER METER
WV WATER VALVE
12" W
6" G
12" S
2" T
DEGREE OF CIRCULAR CURVE
FUT
Lc
CURVE, IN FEET
TOTAL LENGTH OF CIRCULAR
FUTURE
CRB
FC
c D
FIELD CONNECTION
CURB LINE
SLOPE SLP
CIRCULAR CURVE
TANGENT LENGTH OF Tc
SURF SURFACE
ELLIPTICAL PIPE
SQUARE FOOT
STABILIZED CONSTRUCTION
REINFORCED CONCRETE
SCE
SG
S.F.
SF
SCH
SUBGRADE
SILT FENCE
ENTRANCE
SCHEDULE
RCEP
SPIRAL AND CIRCULAR CURVES
AT GRADE INLET PROTECTION
AISC
CD STONE CHECK DAM
STEEL CONSTRUCTION
AMERICAN INSTITUTE OF
AGIP
c
TOTAL CENTRAL ANGLE OF
POINT OF INTERSECTION
CIRCULAR CURVE TO TANGENT
TANGENT TO CIRCULAR CURVE
POINT OF CHANGE FROM
PORTABLE SEDIMENT TANK
POINT OF REVERSE CURVES
POINT ON TANGENT
POINT ON CURVE
OF TWO TANGENTS
POINT OF CHANGE FROM
PI
PLAT
PRC
PT
PST
POT
POC
PLATFORM
PCC
PC
OPP OPPOSITE
ADAAG ADA ACCESSIBILITY GUIDELINES
ASTM AMERICAN SOCIETY FOR TESTING
AND MATERIALS
ELCP ELLIPTICAL CONCRETE PIPE
POINT ON LINE POL
TOP OF GRATE T.G.
T.S. TOP OF STRUCTURE
AASHTO
AND TRANSPORTATION OFFICIALS
AMERICAN SOCIETY OF STATE HIGHWAY
CENTRAL ANGLE OF CIRCULAR CURVE
PARKER-KALON NAIL (SURVEY MARKER)
POINT OF COMPOUND CIRCULAR CURVES
WALL
POINT OF INTERSECTION OF TANGENTS
WM
FH FIRE HYDRANT
EM ELECTRIC METER
GM GAS METER
GV GAS VALVE
PV PETROLEUM VALVE
DETECTABLE WARNING SURFACE
EXISTING PROPOSED
L
STATION EQUATION
TRACK CENTER LINE
STA BK
STA AH =
AH,AHD
C TRACK 1
CCT CAPITAL CRESCENT TRAIL
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
9
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
1

G
E
C

M
a
s
t
e
r

C
A
D
D

F
i l e
s
\
S
u
b
m
i t
t
a
l s
\
0
0
2

-

P
r
e
l i m
i n
a
r
y

E
n
g
i n
e
e
r
i n
g
\
V
o
l u
m
e

0
8
\
1
0
4
2
p
G
I 8
1
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8
DESCRIPTION
NO.
DWG.
NO.
DWG.
NO.
SHEET
NO.
DWG.
NO.
SHEET
DESCRIPTION DESCRIPTION
NO.
SHEET
INDEX OF DRAWINGS - VOLUME
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
GENERAL DRAWINGS
1 TI-8001 TITLE SHEET
2 GN-8001 KEY MAP
3 GN-8002 GENERAL NOTES AND LEGEND
4 GN-8003 CIVIL ABBREVIATIONS AND SYMBOLS
5 GI-8101 INDEX OF SHEETS - VOLUME 8 SHEET 1
6 GI-8102 INDEX OF SHEETS - VOLUME 8 SHEET 2
7 GI-8103 INDEX OF SHEETS - VOLUME 8 SHEET 3
LYTTONSVILLE YARD FACILITY
8 CV-L01 LYTTONSVILLE YARD FACILITY EXISTING CONDITIONS PLAN - SHEET 1 OF 3
9 CV-L02 LYTTONSVILLE YARD FACILITY EXISTING CONDITIONS PLAN - SHEET 2 OF 3
10 CV-L03 LYTTONSVILLE YARD FACILITY EXISTING CONDITIONS PLAN - SHEET 3 OF 3
11 CV-L04 LYTTONSVILLE YARD FACILITY DEMOLITION PLAN - SHEET 1 OF 3
12 CV-L05 LYTTONSVILLE YARD FACILITY DEMOLITION PLAN - SHEET 2 OF 3
13 CV-L06 LYTTONSVILLE YARD FACILITY DEMOLITION PLAN - SHEET 3 OF 3
14 CV-L07 LYTTONSVILLE YARD FACILITY CIVIL SITE PLAN - SHEET 1 OF 3
15 CV-L08 LYTTONSVILLE YARD FACILITY CIVIL SITE PLAN - SHEET 2 OF 3
16 CV-L09 LYTTONSVILLE YARD FACILITY CIVIL SITE PLAN - SHEET 3 OF 3
17 CV-L10 LYTTONSVILLE YARD FACILITY SITE / UTILITY PLAN - SHEET 1 of 3
18 CV-L11 LYTTONSVILLE YARD FACILITY SITE / UTILITY PLAN - SHEET 2 of 3
19 CV-L12 LYTTONSVILLE YARD FACILITY SITE / UTILITY PLAN - SHEET 3 of 3
20 CV-L13 LYTTONSVILLE YARD FACILITY UTILITY DETAILS
21 CV-L14 LYTTONSVILLE YARD FACILITY PARKING LAYOUT
22 DR-L01 LYTTONSVILLE YARD FACILITY SWM & DRAINAGE PLAN - SHEET 1 OF 3
23 DR-L02 LYTTONSVILLE YARD FACILITY SWM & DRAINAGE PLAN - SHEET 2 OF 3
24 DR-L03 LYTTONSVILLE YARD FACILITY SWM & DRAINAGE PLAN - SHEET 3 OF 3
25 DR-L04 LYTTONSVILLE YARD FACILITY DRAINAGE DETAILS
26 DR-L05 LYTTONSVILLE YARD FACILITY DRAINAGE DETAILS
27 LS-L01 LYTTONSVILLE YARD FACILITY LANDSCAPE PLAN - SHEET 1 OF 3
28 LS-L02 LYTTONSVILLE YARD FACILITY LANDSCAPE PLAN - SHEET 2 OF 3
29 LS-L03 LYTTONSVILLE YARD FACILITY LANDSCAPE PLAN - SHEET 3 OF 3
30 TW-L01 LYTTONSVILLE YARD FACILITY ALIGNMENT PLAN - SHEET 1 OF 3
31 TW-L02 LYTTONSVILLE YARD FACILITY ALIGNMENT PLAN - SHEET 2 OF 3
32 TW-L03 LYTTONSVILLE YARD FACILITY ALIGNMENT PLAN - SHEET 3 OF 3
33 TW-L04 LYTTONSVILLE YARD FACILITY PROFILE STA Y1 0+00 TO STA Y1 10+00
34 TW-L05 LYTTONSVILLE YARD FACILITY PROFILE STA Y1 10+00 TO STA Y1 16+91.98
35 TW-L06 LYTTONSVILLE YARD FACILITY PROFILE STA Y2 0+00 TO STA Y2 7+48.75
36 TW-L07 LYTTONSVILLE YARD FACILITY PROFILE STA Y3 0+00 TO STA Y3 9+82.77
37 TW-L08 LYTTONSVILLE YARD FACILITY PROFILE STA Y4 0+00 TO STA Y4 7+50
38 TW-L09 LYTTONSVILLE YARD FACILITY PROFILE STA Y4 7+50 TO STA Y4 11+99.64
39 TW-L10 LYTTONSVILLE YARD FACILITY PROFILE STA Y5 0+00 TO STA Y5 11+27.81
40 TW-L11 LYTTONSVILLE YARD FACILITY PROFILE STA Y6 0+00 TO STA Y6 7+50
41 TW-L12 LYTTONSVILLE YARD FACILITY PROFILE STA Y6 7+50 TO STA Y6 12+26.92
42 TW-L13 LYTTONSVILLE YARD FACILITY PROFILE STA Y7 0+00 TO STA Y7 7+00
43 TW-L14 LYTTONSVILLE YARD FACILITY PROFILE STA Y7 7+00 TO STA Y7 12+33.17
44 TW-L15 LYTTONSVILLE YARD FACILITY PROFILE STA Y8 0+00 TO STA Y8 11+54.41
45 TW-L16 LYTTONSVILLE YARD FACILITY PROFILE STA Y9 0+00 TO STA Y9 11+00
46 TW-L17 LYTTONSVILLE YARD FACILITY PROFILE STA Y9 11+00 TO STA Y9 23+00
47 TW-L18 LYTTONSVILLE YARD FACILITY PROFILE STA Y9 23+00 TO STA Y9 29+09.94
48 TW-L19 LYTTONSVILLE YARD FACILITY PROFILE STA Y10 0+00 TO STA Y10 7+30.61
49 TW-L20 LYTTONSVILLE YARD FACILITY TYPICAL SECTIONS
50 AR-L01 LYTTONSVILLE YARD FACILITY ARCHITECTURAL ABBREVIATIONS AND LEGEND
51 AR-L02 LYTTONSVILLE YARD FACILITY CODE ANALYSIS - YARD AND DECK LEVELS
52 AR-L03 LYTTONSVILLE YARD FACILITY CODE ANALYSIS - WASH BUILDING
53 AR-L04 LYTTONSVILLE YARD FACILITY CODE ANALYSIS - OFFICE 1ST AND 2ND FLOORS
54 AR-L05 LYTTONSVILLE YARD FACILITY YARD LEVEL - COMPOSITE PLAN
55 AR-L06 LYTTONSVILLE YARD FACILITY DECK LEVEL - COMPOSITE PLAN
56 AR-L07 LYTTONSVILLE YARD FACILITY OFFICE - 1ST AND 2ND FLR COMPOSITE PLANS
57 AR-L08 LYTTONSVILLE YARD FACILITY OFFICE - ROOF COMPOSITE PLAN
58 AR-L10 LYTTONSVILLE YARD FACILITY YARD LEVEL - FLOOR PLAN
59 AR-L11 LYTTONSVILLE YARD FACILITY YARD LEVEL - ROOF PLAN
60 AR-L12 LYTTONSVILLE YARD FACILITY WASH BUILDING - FLOOR AND ROOF PLANS
61 AR-L13 LYTTONSVILLE YARD FACILITY OFFICE - FIRST FLOOR PLAN
62 AR-L14 LYTTONSVILLE YARD FACILITY OFFICE - SECOND FLOOR PLAN
63 AR-L15 LYTTONSVILLE YARD FACILITY OFFICE - ROOF PLAN
64 AR-L20 LYTTONSVILLE YARD FACILITY YARD LEVEL - REFLECTED CEILING PLAN
65 AR-L21 LYTTONSVILLE YARD FACILITY WASH BUILDING - REFLECTED CEILING PLAN
66 AR-L22 LYTTONSVILLE YARD FACILITY OFFICE - 1ST FLOOR REFLECTED CEILING PLAN
67 AR-L23 LYTTONSVILLE YARD FACILITY OFFICE 2ND FLOOR REFLECTED CEILING PLAN
68 AR-L30 LYTTONSVILLE YARD FACILITY YARD LEVEL - ELEVATIONS
69 AR-L31 LYTTONSVILLE YARD FACILITY OFFICE - BUILDING ELEVATIONS
LYTTONSVILLE YARD FACILITY (CONTINUED)
70 AR-L32 LYTTONSVILLE YARD FACILITY OFFICE - BUILDING ELEVATIONS
71 AR-L40 LYTTONSVILLE YARD FACILITY OVERALL SECTIONS
72 AR-L41 LYTTONSVILLE YARD FACILITY WASH BUILDING - ELEVATIONS AND SECTIONS
73 AR-L42 LYTTONSVILLE YARD FACILITY OFFICE - BUILDING SECTIONS
74 AR-L43 LYTTONSVILLE YARD FACILITY OFFICE WALL SECTIONS
75 AR-L50 LYTTONSVILLE YARD FACILITY ENLARGED TOILET ROOM PLANS
76 AR-L51 LYTTONSVILLE YARD FACILITY ENLARGED TOILET ROOM PLANS
77 AR-L52 LYTTONSVILLE YARD FACILITY VANITY AND MISCELLANEOUS DETAILS
78 AR-L53 LYTTONSVILLE YARD FACILITY ENLARGED PLANS
79 AR-L70 LYTTONSVILLE YARD FACILITY ENLARGED STAIR/ELEVATOR PLANS S1 E-1 E-2
80 AR-L71 LYTTONSVILLE YARD FACILITY ENLARGED STAIR/ELEVATOR PLANS S2 E-3
81 AR-L72 LYTTONSVILLE YARD FACILITY ENLARGED STAIR PLANS S3
82 AR-L73 LYTTONSVILLE YARD FACILITY ENLARGED STAIR PLANS S4
83 AR-L74 LYTTONSVILLE YARD FACILITY STAIR S2 SECTIONS
84 AR-L80 LYTTONSVILLE YARD FACILITY DOOR SCHEDULES
85 AR-L81 LYTTONSVILLE YARD FACILITY DOOR AND MISCELLANEOUS DETAILS
86 AR-L82 LYTTONSVILLE YARD FACILITY WINDOW/ STOREFRONT SCHEDULE & DETAILS
87 AR-L84 LYTTONSVILLE YARD FACILITY FINISH SCHEDULE
88 AR-L90 LYTTONSVILLE YARD FACILITY EQUIPMENT NOTES AND EQUIPMENT LIST
89 AR-L91 LYTTONSVILLE YARD FACILITY YARD LEVEL - EQUIPMENT PLAN
90 AR-L92 LYTTONSVILLE YARD FACILITY WASH BUILDING - EQUIPMENT PLAN
91 ST-L01 LYTTONSVILLE YARD FACILITY GENERAL STRUCTURAL NOTES - SHEET 1 OF 2
92 ST-L02 LYTTONSVILLE YARD FACILITY GENERAL STRUCTURAL NOTES - SHEET 2 OF 2
93 ST-L03 LYTTONSVILLE YARD FACILITY PILE LAYOUT PLAN
94 ST-L04 LYTTONSVILLE YARD FACILITY RETAINING WALL GENERAL PLAN & ELEVATION
95 ST-L05 LYTTONSVILLE YARD FACILITY RETAINING WALL GENERAL PLAN
96 ST-L06 LYTTONSVILLE YARD FACILITY RETAINING WALL ELEVATION
97 ST-L07 LYTTONSVILLE YARD FACILITY FOUNDATION PLAN - SHEET 1 OF 3
98 ST-L08 LYTTONSVILLE YARD FACILITY FOUNDATION PLAN - SHEET 2 OF 3
99 ST-L09 LYTTONSVILLE YARD FACILITY FOUNDATION PLAN - SHEET 3 OF 3
100 ST-L10 LYTTONSVILLE YARD FACILITY FRAMING AND SLAB PLAN - SHEET 1 OF 2
101 ST-L11 LYTTONSVILLE YARD FACILITY FRAMING AND SLAB PLAN - SHEET 2 OF 2
102 ST-L12 LYTTONSVILLE YARD FACILITY COLUMN LAYOUT & 2ND FLOOR FRAMING PLAN
103 ST-L13 LYTTONSVILLE YARD FACILITY OFFICE ROOF FRAMING PLAN
104 ST-L14 LYTTONSVILLE YARD FACILITY WASH BUILDING ROOF FRAMING PLAN
105 ST-L15 LYTTONSVILLE YARD FACILITY STAIR S4 FRAMING PLAN
106 ST-L16 LYTTONSVILLE YARD FACILITY BRACE ELEVATIONS
107 ST-L17 LYTTONSVILLE YARD FACILITY LONGITUDINAL SECTION ALONG COLUMN "C"
108 ST-L18 LYTTONSVILLE YARD FACILITY CROSS SECTION OF PARKING GARAGE
109 ST-L19 LYTTONSVILLE YARD FACILITY CROSS SECTION OF PARKING GARAGE
110 ST-L20 LYTTONSVILLE YARD FACILITY SECTIONS AND DETAILS
111 ST-L21 LYTTONSVILLE YARD FACILITY RAIL PEDESTAL DETAIL
112 ST-L22 LYTTONSVILLE YARD FACILITY SECTIONS AND DETAILS
113 ST-L23 LYTTONSVILLE YARD FACILITY DETAILS
114 ST-L24 LYTTONSVILLE YARD FACILITY TYPICAL DETAILS
115 ST-L25 LYTTONSVILLE YARD FACILITY TYPICAL DETAILS
116 ST-L26 LYTTONSVILLE YARD FACILITY TYPICAL DETAILS
117 ST-L27 LYTTONSVILLE YARD FACILITY TYPICAL DETAILS
118 ME-L01 LYTTONSVILLE YARD FACILITY GENERAL NOTES AND ABBREVIATIONS
119 ME-L10 LYTTONSVILLE YARD FACILITY YARD LEVEL FLOOR PLAN - HVAC
120 ME-L11 LYTTONSVILLE YARD FACILITY YARD LEVEL ROOF PLAN - HVAC
121 ME-L12 LYTTONSVILLE YARD FACILITY WASH BLDG FLOOR AND ROOF PLANS - HVAC
122 ME-L13 LYTTONSVILLE YARD FACILITY OFFICE FIRST FLOOR PLAN - HVAC
123 ME-L14 LYTTONSVILLE YARD FACILITY OFFICE SECOND FLOOR PLAN - HVAC
124 ME-L80 LYTTONSVILLE YARD FACILITY MECHANICAL SCHEDULES AND DETAILS
125 ME-L81 LYTTONSVILLE YARD FACILITY MECHANICAL SCHEDULES AND DETAILS
126 PL-L01 LYTTONSVILLE YARD FACILITY GENERAL NOTES AND ABBREVIATIONS
127 PL-L05 LYTTONSVILLE YARD FACILITY YARD LEVEL COMPOSITE PLAN - PLUMBING
128 PL-L10 LYTTONSVILLE YARD FACILITY YARD LEVEL FLOOR PLAN - PLUMBING
129 PL-L12 LYTTONSVILLE YARD FACILITY WASH BLDG FLOOR PLAN - PLUMBING
130 PL-L13 LYTTONSVILLE YARD FACILITY OFFICE FIRST FLOOR PLAN - PLUMBING
131 PL-L14 LYTTONSVILLE YARD FACILITY OFFICE SECOND FLOOR PLAN - PLUMBING
132 PL-L15 LYTTONSVILLE YARD FACILITY OFFICE ROOF PLAN - PLUMBING
133 PL-L16 LYTTONSVILLE YARD FACILITY OFFICE YARD LEVEL PLAN - PLUMBING
134 PL-L50 LYTTONSVILLE YARD FACILITY ENLARGED TOILET ROOM PLANS - PLUMBING
135 PL-L51 LYTTONSVILLE YARD FACILITY ENLARGED TOILET ROOM PLANS - PLUMBING
136 PL-L80 LYTTONSVILLE YARD FACILITY PLUMBING SCHEDULE
137 EL-L01 LYTTONSVILLE YARD FACILITY GENERAL NOTES AND ABBREVIATIONS
138 EL-L02 LYTTONSVILLE YARD FACILITY ELECTRICAL SYMBOL LIST
139 EL-L03 LYTTONSVILLE YARD FACILITY YARD LEVEL SITE PLAN - LIGHTING/POWER
140 EL-L04 LYTTONSVILLE YARD FACILITY YARD STORAGE PLAN - LIGHTING
141 EL-L05 LYTTONSVILLE YARD FACILITY YARD LEVEL FLOOR PLAN - LIGHTING
142 EL-L06 LYTTONSVILLE YARD FACILITY PARKING DECK LEVEL PLAN - LIGHTING
143 EL-L07 LYTTONSVILLE YARD FACILITY OFFICE FIRST FLOOR PLAN - LIGHTING
144 EL-L08 LYTTONSVILLE YARD FACILITY OFFICE SECOND FLOOR PLAN - LIGHTING
145 EL-L09 LYTTONSVILLE YARD FACILITY WASH BUILDING PLAN - LIGHTING
146 EL-L10 LYTTONSVILLE YARD FACILITY YARD LEVEL FLOOR PLAN - POWER
147 EL-L11 LYTTONSVILLE YARD FACILITY OFFICE FIRST FLOOR PLAN - POWER
148 EL-L12 LYTTONSVILLE YARD FACILITY OFFICE SECOND FLOOR PLAN - POWER
149 EL-L13 LYTTONSVILLE YARD FACILITY WASH BUILDING PLAN - POWER
150 EL-L14 LYTTONSVILLE YARD FACILITY YARD STORAGE PLAN - FIRE ALARM
151 EL-L15 LYTTONSVILLE YARD FACILITY YARD LEVEL FLOOR PLAN - FIRE ALARM
152 EL-L16 LYTTONSVILLE YARD FACILITY OFFICE FIRST FLOOR PLAN - FIRE ALARM
153 EL-L17 LYTTONSVILLE YARD FACILITY OFFICE SECOND FLOOR PLAN - FIRE ALARM
154 EL-L18 LYTTONSVILLE YARD FACILITY WASH BUILDING - FIRE ALARM
155 EL-L20 LYTTONSVILLE YARD FACILITY LIGHTING FIXTURE SCHEDULE
156 EL-L21 LYTTONSVILLE YARD FACILITY ELECTRICAL DETAILS - 1
157 EL-L22 LYTTONSVILLE YARD FACILITY POWER RISER DIAGRAM
158 EL-L23 LYTTONSVILLE YARD FACILITY POWER SINGLE LINE DIAGRAM
159 EL-L24 LYTTONSVILLE YARD FACILITY FIRE ALARM ANNUNCIATOR PANEL DIAGRAM
160 EL-L25 LYTTONSVILLE YARD FACILITY RISER AND NOTES - FIRE ALARM
161 EL-L26 LYTTONSVILLE YARD FACILITY ELECTRICAL DETAILS - 2
162 FP-L01
163 FP-L02 LYTTONSVILLE YARD FACILITY DESIGN CRITERIA AND HAZARD CLASSIFICATION
164 FP-L03 LYTTONSVILLE YARD FACILITY ZONES LAYOUT PLAN
165 FP-L04 LYTTONSVILLE YARD FACILITY YARD LEVEL FIRE PROTECTION PLAN
166 FP-L05 LYTTONSVILLE YARD FACILITY YARD LEVEL FIRE PROTECTION PLAN
167 FP-L06 LYTTONSVILLE YARD FACILITY OFFICE FIRST FLOOR PLAN - FIRE PROTECTION
168 FP-L07 LYTTONSVILLE YARD FACILITY OFFICE SECOND FLOOR PLAN - FIRE PROTECTION
169 FP-L08 LYTTONSVILLE YARD FACILITY WASH BUILDING PLAN - FIRE PROTECTION
170 FP-L09 LYTTONSVILLE YARD FACILITY FIRE PROTECTION RISER
GLENRIDGE YARD & SHOP FACILITY
171 CV-G01 GLENRIDGE YARD & SHOP FACILITY EXISTING CONDITIONS - SHEET 1 OF 4
172 CV-G02 GLENRIDGE YARD & SHOP FACILITY EXISTING CONDITIONS - SHEET 2 OF 4
173 CV-G03 GLENRIDGE YARD & SHOP FACILITY EXISTING CONDITIONS - SHEET 3 OF 4
174 CV-G04 GLENRIDGE YARD & SHOP FACILITY EXISTING CONDITIONS - SHEET 4 OF 4
175 CV-G11 GLENRIDGE YARD & SHOP FACILITY DEMOLITION PLAN - SHEET 1 OF 4
176 CV-G12 GLENRIDGE YARD & SHOP FACILITY DEMOLITION PLAN - SHEET 2 OF 4
177 CV-G13 GLENRIDGE YARD & SHOP FACILITY DEMOLITION PLAN - SHEET 3 OF 4
178 CV-G14 GLENRIDGE YARD & SHOP FACILITY DEMOLITION PLAN - SHEET 4 OF 4
179 CV-G21 GLENRIDGE YARD & SHOP FACILITY CIVIL SITE PLAN - SHEET 1 OF 4
180 CV-G22 GLENRIDGE YARD & SHOP FACILITY CIVIL SITE PLAN - SHEET 2 OF 4
181 CV-G23 GLENRIDGE YARD & SHOP FACILITY CIVIL SITE PLAN - SHEET 3 OF 4
182 CV-G24 GLENRIDGE YARD & SHOP FACILITY CIVIL SITE PLAN - SHEET 4 OF 4
183 CV-G31 GLENRIDGE YARD & SHOP FACILITY SITE GRADING PLAN - SHEET 1 OF 4
184 CV-G32 GLENRIDGE YARD & SHOP FACILITY SITE GRADING PLAN - SHEET 2 OF 4
185 CV-G33 GLENRIDGE YARD & SHOP FACILITY SITE GRADING PLAN - SHEET 3 OF 4
186 CV-G34 GLENRIDGE YARD & SHOP FACILITY SITE GRADING PLAN - SHEET 4 OF 4
187 CV-G41
188 CV-G42
189 CV-G43 GLENRIDGE YARD & SHOP FACILITY RET WALL gD A SECTION AND DETAILS
190 CV-G44
191 CV-G45
192 CV-G46
193 CV-G47
194 LS-G01 GLENRIDGE YARD & SHOP FACILITY LANDSCAPE PLAN - SHEET 1 OF 4
195 LS-G02 GLENRIDGE YARD & SHOP FACILITY LANDSCAPE PLAN - SHEET 2 OF 4
196 LS-G03 GLENRIDGE YARD & SHOP FACILITY LANDSCAPE PLAN - SHEET 3 OF 4
197 LS-G04 GLENRIDGE YARD & SHOP FACILITY LANDSCAPE PLAN - SHEET 4 OF 4
198 TW-G01 GLENRIDGE YARD & SHOP FACILITY ALIGNMENT PLAN - SHEET 1 OF 4
199 TW-G02 GLENRIDGE YARD & SHOP FACILITY ALIGNMENT PLAN - SHEET 2 OF 4
200 TW-G03 GLENRIDGE YARD & SHOP FACILITY ALIGNMENT PLAN - SHEET 3 OF 4
201 TW-G04 GLENRIDGE YARD & SHOP FACILITY ALIGNMENT PLAN - SHEET 4 OF 4
202 TW-G05 GLENRIDGE YARD & SHOP FACILITY PROFILE STA TRK 3 300+00 TO STA 312+30
203 TW-G06 GLENRIDGE YARD & SHOP FACILITY PROFILE STA TRK 9 900+00 TO STA 923+80
204 TW-G07 GLENRIDGE YARD & SHOP FACILITY PROFILE TRACKS TRK 4 AND TRK 5
205 TW-G08 GLENRIDGE YARD & SHOP FACILITY PROFILE TRACKS TRK 6 AND TRK 7
206 TW-G09 GLENRIDGE YARD & SHOP FACILITY TRACKS PROFILE TRK 10 AND TRK 11
207 TW-G10 GLENRIDGE YARD & SHOP FACILITY PROFILE TRACKS TRK 8 AND MOW
208 DR-G01
209 DR-G02
210 DR-G03 GLENRIDGE YARD & SHOP FACILITY SWM & DRAINAGE PLAN SOUTH PORTION
LYTTONSVILLE YARD FACILITY PROTECTION NOTES, SYMBOLS & ABBREVIATIONS
GLENRIDGE YARD & SHOP FACILITY RET WALL gD A GENERAL PLAN AND ELEV
GLENRIDGE YARD & SHOP FACILITY RET WALL gD A GENERAL PLAN AND ELEV
GLENRIDGE YARD & SHOP FACILITY RET WALL gD B GENERAL PLAN AND ELEV
GLENRIDGE YARD & SHOP FACILITY RET WALL gD B GENERAL PLAN AND ELEV
GLENRIDGE YARD & SHOP FACILITY RET WALL gD C GENERAL PLAN AND ELEV
GLENRIDGE YARD & SHOP FACILITY RET WALL gD C GENERAL PLAN AND ELEV
LYTTONSVILLE YARD FACILITY (CONTINUED)
SHEET 1
DECEMBER 2013




GI-8101
5 NONE
INDEX OF SHEETS - VOLUME 8
GLENRIDGE YARD & SHOP FACILITY SWM/DRAIN PLAN STA TRK 1 874+00
GLENRIDGE YARD & SHOP FACILITY SWM/DRAIN PLAN STA TRK 1 886+14
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
9
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
1

G
E
C

M
a
s
t
e
r

C
A
D
D

F
i l e
s
\
S
u
b
m
i t
t
a
l s
\
0
0
2

-

P
r
e
l i m
i n
a
r
y

E
n
g
i n
e
e
r
i n
g
\
V
o
l u
m
e

0
8
\
1
0
4
2
p
G
I 8
1
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8
DESCRIPTION
NO.
DWG.
NO.
DWG.
NO.
SHEET
NO.
DWG.
NO.
SHEET
DESCRIPTION DESCRIPTION
NO.
SHEET
INDEX OF DRAWINGS - VOLUME
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
GLENRIDGE YARD & SHOP FACILITY (CONTINUED)
211 AR-G001 GLENRIDGE YARD & SHOP FACILITY ARCHITECTURAL ABBREVIATIONS AND LEGEND
212 AR-G002 GLENRIDGE YARD & SHOP FACILITY BUILDING CODE ANALYSIS
213 AR-G003 GLENRIDGE YARD & SHOP FACILITY EQUIPMENT NOTES AND ABBREVIATIONS
214 AR-G004 GLENRIDGE YARD & SHOP FACILITY EQUIPMENT LIST - SHEET 1 OF 2
215 AR-G005 GLENRIDGE YARD & SHOP FACILITY EQUIPMENT LIST - SHEET 2 OF 2
216 AR-G101 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN
217 AR-G102 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN
218 AR-G103 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN
219 AR-G104 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN
220 AR-G105 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT A
221 AR-G106 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT B
222 AR-G107 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT C
223 AR-G108 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT D
224 AR-G109 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT E
225 AR-G110 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT F
226 AR-G111 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT A
227 AR-G112 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT B
228 AR-G113 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT C
229 AR-G114 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT D
230 AR-G115 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT A
231 AR-G116 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT B
232 AR-G117 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT C
233 AR-G118 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT D
234 AR-G119 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT E
235 AR-G120 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT F
236 AR-G121 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN SEGMENT A
237 AR-G122 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN SEGMENT B
238 AR-G123 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN SEGMENT C
239 AR-G124 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN SEGMENT D
240 AR-G125 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN SEGMENT E
241 AR-G126 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN SEGMENT F
242 AR-G140 GLENRIDGE YARD & SHOP FACILITY OVERALL FIRST FLOOR EQUIPMENT PLAN
243 AR-G141 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR EQUIPMENT PLAN - SEGMENT A
244 AR-G142 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR EQUIPMENT PLAN - SEGMENT B
245 AR-G143 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR EQUIPMENT PLAN - SEGMENT C
246 AR-G144 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR EQUIPMENT PLAN - SEGMENT D
247 AR-G145 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR EQUIPMENT PLAN - SEGMENT E
248 AR-G146 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR EQUIPMENT PLAN - SEGMENT F
249 AR-G150 GLENRIDGE YARD & SHOP FACILITY OVERALL SECOND FLOOR EQUIPMENT PLAN
250 AR-G151 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR EQUIPMENT PLAN - SEGMENT A
251 AR-G152 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR EQUIPMENT PLAN - SEGMENT B
252 AR-G153 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR EQUIPMENT PLAN - SEGMENT C
253 AR-G154 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR EQUIPMENT PLAN - SEGMENT D
254 AR-G160 GLENRIDGE YARD & SHOP FACILITY OVERALL ROOF EQUIPMENT PLAN
255 AR-G161 GLENRIDGE YARD & SHOP FACILITY ROOF EQUIPMENT PLAN - SEGMENT D
256 AR-G201 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR REFLECTED CEILING PLANS
257 AR-G202 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR REFLECTED CEILING PLAN
258 AR-G203 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR REFLECTED CEILING PLAN
259 AR-G204 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR REFLECTED CEILING PLAN B
260 AR-G205 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR REFLECTED CEILING PLAN E
261 AR-G301 GLENRIDGE YARD & SHOP FACILITY BUILDING NORTH ELEVATION
262 AR-G302 GLENRIDGE YARD & SHOP FACILITY BUILDING SOUTH ELEVATION
263 AR-G303 GLENRIDGE YARD & SHOP FACILITY BUILDING WEST ELEVATION
264 AR-G304 GLENRIDGE YARD & SHOP FACILITY BUILDING EAST ELEVATION
265 AR-G401 GLENRIDGE YARD & SHOP FACILITY BUILDING SECTION A
266 AR-G402 GLENRIDGE YARD & SHOP FACILITY BUILDING SECTION B
267 AR-G403 GLENRIDGE YARD & SHOP FACILITY BUILDING SECTION C
268 AR-G404 GLENRIDGE YARD & SHOP FACILITY BUILDING SECTION D
269 AR-G405 GLENRIDGE YARD & SHOP FACILITY BUILDING SECTION E
270 AR-G406 GLENRIDGE YARD & SHOP FACILITY WALL SECTIONS
271 AR-G407 GLENRIDGE YARD & SHOP FACILITY WALL SECTIONS
272 AR-G501 GLENRIDGE YARD & SHOP FACILITY ENLARGED TOILET/LOCKER ROOM PLANS
273 AR-G502 GLENRIDGE YARD & SHOP FACILITY ENLARGED TOILET/LOCKER ROOM PLANS
274 AR-G503 GLENRIDGE YARD & SHOP FACILITY ENLARGED CASEWORK PLAN & DETAILS
275 AR-G504 GLENRIDGE YARD & SHOP FACILITY ENLARGED STAIR PLANS
276 AR-G505 GLENRIDGE YARD & SHOP FACILITY ENLARGED STAIR PLANS
277 AR-G601 GLENRIDGE YARD & SHOP FACILITY WALL TYPES
278 AR-G602
279 AR-G801 GLENRIDGE YARD & SHOP FACILITY DOOR SCHEDULE
280 AR-G802 GLENRIDGE YARD & SHOP FACILITY DOOR SCHEDULE & DETAILS
281 AR-G803 GLENRIDGE YARD & SHOP FACILITY WINDOWSCHEDULE
282 AR-G804 GLENRIDGE YARD & SHOP FACILITY ROOM FINISH SCHEDULE
283 AR-G805 GLENRIDGE YARD & SHOP FACILITY ROOM FINISH SCHEDULE
284 ST-G001 GLENRIDGE YARD & SHOP FACILITY GENERAL NOTES AND ABBREVIATION 1 OF 2
285 ST-G002 GLENRIDGE YARD & SHOP FACILITY GENERAL NOTES AND ABBREVIATION 2 OF 2
286 ST-G100 GLENRIDGE YARD & SHOP FACILITY OVERALL FIRST FLOOR PLAN
287 ST-G101 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR FOUNDATION PLAN - SEGMENT A
288 ST-G102 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR FOUNDATION PLAN - SEGMENT B
289 ST-G103 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR FOUNDATION PLAN - SEGMENT C
290 ST-G104 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR FOUNDATION PLAN - SEGMENT D
291 ST-G105 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR FOUNDATION PLAN - SEGMENT E
292 ST-G106 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR FOUNDATION PLAN - SEGMENT F
293 ST-G110 GLENRIDGE YARD & SHOP FACILITY OVERALL FIRST FLOOR SLAB PLAN
294 ST-G111 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR SLAB PLAN - SEGMENT A
295 ST-G112 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR SLAB PLAN - SEGMENT B
296 ST-G113 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR SLAB PLAN - SEGMENT C
297 ST-G114 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR SLAB PLAN - SEGMENT D
298 ST-G115 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR SLAB PLAN - SEGMENT E
299 ST-G116 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR SLAB PLAN - SEGMENT F
300 ST-G120 GLENRIDGE YARD & SHOP FACILITY OVERALL SECOND FLOOR PLAN
301 ST-G121 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR FRAMING PLAN - SEGMENT A
302 ST-G122 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR FRAMING PLAN - SEGMENT B
303 ST-G123 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR FRAMING PLAN - SEGMENT C
304 ST-G124 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR FRAMING PLAN - SEGMENT D
305 ST-G125 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR FRAMING PLAN - SEGMENT E
306 ST-G126 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR FRAMING PLAN - SEGMENT F
307 ST-G130 GLENRIDGE YARD & SHOP FACILITY OVERALL THIRD FLOOR PLAN
308 ST-G131 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR FRAMING PLAN - SEGMENT A
309 ST-G132 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR FRAMING PLAN - SEGMENT B
310 ST-G133 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR FRAMING PLAN - SEGMENT C
311 ST-G134 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR FRAMING PLAN - SEGMENT D
312 ST-G135 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR FRAMING PLAN - SEGMENT E
313 ST-G136 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR FRAMING PLAN - SEGMENT F
314 ST-G140 GLENRIDGE YARD & SHOP FACILITY OVERALL ROOF PLAN
315 ST-G141 GLENRIDGE YARD & SHOP FACILITY ROOF FRAMING PLAN - SEGMENT A
316 ST-G142 GLENRIDGE YARD & SHOP FACILITY ROOF FRAMING PLAN - SEGMENT B
317 ST-G143 GLENRIDGE YARD & SHOP FACILITY ROOF FRAMING PLAN - SEGMENT E
318 ST-G300 GLENRIDGE YARD & SHOP FACILITY CONCRETE SECTIONS
319 ST-G301 GLENRIDGE YARD & SHOP FACILITY CONCRETE INSPECTION PIT SECTIONS
320 ST-G302 GLENRIDGE YARD & SHOP FACILITY HOIST PIT SECTIONS
321 ST-G303 GLENRIDGE YARD & SHOP FACILITY PAINT BOOTH SECTIONS
322 ST-G304 GLENRIDGE YARD & SHOP FACILITY WHEEL TRUING PIT SECTIONS
323 ST-G400 GLENRIDGE YARD & SHOP FACILITY WHEEL TRUING PIT PARTIAL PLAN-SHEET 1 OF 3
324 ST-G401 GLENRIDGE YARD & SHOP FACILITY WHEEL TRUING PIT PARTIAL PLAN-SHEET 2 OF 3
325 ST-G402 GLENRIDGE YARD & SHOP FACILITY WHEEL TRUING PIT PARTIAL PLAN-SHEET 3 OF 3
326 ST-G410 GLENRIDGE YARD & SHOP FACILITY PLATFORM PLANS AT GRIDS C AND E (NORTH)
327 ST-G411 GLENRIDGE YARD & SHOP FACILITY PLATFORM PLANS AT GRID E (SOUTH)
328 ST-G530 GLENRIDGE YARD & SHOP FACILITY STEEL DETAILS
329 ME-G001 GLENRIDGE YARD & SHOP FACILITY GENERAL NOTES AND ABBREVIATIONS
330 ME-G105 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR HVAC PLAN SEGMENT A
331 ME-G106 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR HVAC PLAN SEGMENT B
332 ME-G107 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR HVAC PLAN SEGMENT C
333 ME-G108 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR HVAC PLAN SEGMENT D
334 ME-G109 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR HVAC PLAN SEGMENT E
335 ME-G110 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR HVAC PLAN SEGMENT F
336 ME-G111 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR HVAC PLAN SEGMENT A
337 ME-G112 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR HVAC PLAN SEGMENT B
338 ME-G115 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR HVAC PLAN SEGMENT A
339 ME-G116 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR HVAC PLAN SEGMENT B
340 ME-G119 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR HVAC PLAN SEGMENT E
341 ME-G121 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN HVAC SEGMENT A
342 ME-G122 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN HVAC SEGMENT B
343 ME-G123 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN HVAC SEGMENT C
344 ME-G124 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN HVAC SEGMENT D
345 ME-G125 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN HVAC SEGMENT E
346 ME-G126 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN HVAC SEGMENT F
347 ME-G801 GLENRIDGE YARD & SHOP FACILITY MECHANICAL SCHEDULES AND DETAILS
348 ME-G802 GLENRIDGE YARD & SHOP FACILITY MECHANICAL SCHEDULES AND DETAILS
349 PL-G001 GLENRIDGE YARD & SHOP FACILITY GENERAL NOTES AND ABBREVIATIONS
350 PL-G105 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLUMBING PLAN - SEGMENT A
351 PL-G106 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLUMBING PLAN - SEGMENT B
352 PL-G107 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLUMBING PLAN - SEGMENT C
353 PL-G108 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLUMBING PLAN - SEGMENT D
354 PL-G109 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLUMBING PLAN - SEGMENT E
355 PL-G110 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLUMBING PLAN - SEGMENT F
356 PL-G111 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLUMBING PLAN - SEGMENT A
357 PL-G112 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLUMBING PLAN - SEGMENT B
358 PL-G113 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLUMBING PLAN - SEGMENT C
359 PL-G114 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLUMBING PLAN - SEGMENT D
360 PL-G115 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLUMBING PLAN - SEGMENT A
361 PL-G116 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLUMBING PLAN - SEGMENT B
362 PL-G119 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLUMBING PLAN - SEGMENT E
363 PL-G121 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN PLUMBING - SEGMENT A
364 PL-G122 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN PLUMBING - SEGMENT B
365 PL-G123 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN PLUMBING - SEGMENT C
366 PL-G124 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN PLUMBING - SEGMENT D
367 PL-G125 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN PLUMBING - SEGMENT E
368 PL-G126 GLENRIDGE YARD & SHOP FACILITY ROOF PLAN PLUMBING - SEGMENT F
369 PL-G501 GLENRIDGE YARD & SHOP FACILITY ENLARGED TOILET/LOCKER ROOM PLANS
370 PL-G502 GLENRIDGE YARD & SHOP FACILITY ENLARGED TOILET/LOCKER ROOM PLANS
371 PL-G801 GLENRIDGE YARD & SHOP FACILITY PLUMBING SCHEDULE
372 EL-G001 GLENRIDGE YARD & SHOP FACILITY GENERAL NOTES AND ABBREVIATIONS
373 EL-G002 GLENRIDGE YARD & SHOP FACILITY ELECTRICAL SYMBOL LIST
374 EL-G101 GLENRIDGE YARD & SHOP FACILITY SITE PLAN - LIGHTING AND POWER
375 EL-G102 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT A - LIGHTING
376 EL-G103 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT B - LIGHTING
377 EL-G104 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT C - LIGHTING
378 EL-G105 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT D - LIGHTING
379 EL-G106 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT E - LIGHTING
380 EL-G107 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT F - LIGHTING
381 EL-G108 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT A - LIGHTING
382 EL-G109 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT B - LIGHTING
383 EL-G110 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT C - LIGHTING
384 EL-G111 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT D - LIGHTING
385 EL-G112 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT A - LIGHTING
386 EL-G113 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT B - LIGHTING
387 EL-G114 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT C - LIGHTING
388 EL-G115 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT D - LIGHTING
389 EL-G116 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT E - LIGHTING
390 EL-G117 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT F - LIGHTING
391 EL-G118 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT A - POWER
392 EL-G119 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT B - POWER
393 EL-G120 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT C - POWER
394 EL-G121 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT D - POWER
395 EL-G122 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT E - POWER
396 EL-G123 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT F - POWER
397 EL-G124 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT A - POWER
398 EL-G125 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT B - POWER
399 EL-G126 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT C - POWER
400 EL-G127 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT D - POWER
401 EL-G128 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT A - POWER
402 EL-G129 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT B - POWER
403 EL-G130 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT C - POWER
404 EL-G131 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT D - POWER
405 EL-G132 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT E - POWER
406 EL-G133 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT F - POWER
407 EL-G134 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT A - FIRE ALARM
408 EL-G135 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT B - FIRE ALARM
409 EL-G136 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT C - FIRE ALARM
410 EL-G137 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT D - FIRE ALARM
411 EL-G138 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT E - FIRE ALARM
412 EL-G139 GLENRIDGE YARD & SHOP FACILITY FIRST FLOOR PLAN SEGMENT F - FIRE ALARM
413 EL-G140 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT A-FIRE ALARM
414 EL-G141 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT B-FIRE ALARM
415 EL-G142 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT C-FIRE ALARM
416 EL-G143 GLENRIDGE YARD & SHOP FACILITY SECOND FLOOR PLAN SEGMENT D-FIRE ALARM
417 EL-G144 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT A - FIRE ALARM
418 EL-G145 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT B - FIRE ALARM
419 EL-G146 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT C - FIRE ALARM
420 EL-G147 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT D - FIRE ALARM
421 EL-G148 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT E - FIRE ALARM
422 EL-G149 GLENRIDGE YARD & SHOP FACILITY THIRD FLOOR PLAN SEGMENT F - FIRE ALARM
423 EL-G401 GLENRIDGE YARD & SHOP FACILITY ELECTRICAL AND EMERGENCY PLANS - POWER
424 EL-G501 GLENRIDGE YARD & SHOP FACILITY ELECTRICAL DETAILS - 1
425 EL-G502 GLENRIDGE YARD & SHOP FACILITY ELECTRICAL DETAILS - 2
426 EL-G601 GLENRIDGE YARD & SHOP FACILITY LIGHTING FIXTURE SCHEDULE
GLENRIDGE YARD & SHOP FACILITY (CONTINUED) GLENRIDGE YARD & SHOP FACILITY (CONTINUED)
GLENRIDGE YARD & SHOP FACILITY ADA NOTES AND DETAILS
SHEET 2
DECEMBER 2013




GI-8102
6 NONE
INDEX OF SHEETS - VOLUME 8
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
9
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
1

G
E
C

M
a
s
t
e
r

C
A
D
D

F
i l e
s
\
S
u
b
m
i t
t
a
l s
\
0
0
2

-

P
r
e
l i m
i n
a
r
y

E
n
g
i n
e
e
r
i n
g
\
V
o
l u
m
e

0
8
\
1
0
4
2
p
G
I 8
1
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8
DESCRIPTION
NO.
DWG.
NO.
DWG.
NO.
SHEET
NO.
DWG.
NO.
SHEET
DESCRIPTION DESCRIPTION
NO.
SHEET
INDEX OF DRAWINGS - VOLUME
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
427 EL-G602 GLENRIDGE YARD & SHOP FACILITY POWER SINGLE LINE DIAGRAM
428 FP-G001 GLENRIDGE YARD & SHOP FACILITY GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
429 FP-G101 GLENRIDGE YARD & SHOP FACILITY - FIRST FLOOR PLAN SEGMENT A - FIRE PROTECTION
430 FP-G102 GLENRIDGE YARD & SHOP FACILITY - FIRST FLOOR PLAN SEGMENT B - FIRE PROTECTION
431 FP-G103 GLENRIDGE YARD & SHOP FACILITY - FIRST FLOOR PLAN SEGMENT C - FIRE PROTECTION
432 FP-G104
433 FP-G105 GLENRIDGE YARD & SHOP FACILITY - FIRST FLOOR PLAN SEGMENT E - FIRE PROTECTION
434 FP-G106 GLENRIDGE YARD & SHOP FACILITY - FIRST FLOOR PLAN SEGMENT F - FIRE PROTECTION
435 FP-G107 GLENRIDGE YARD & SHOP FACILITY - SECOND FLOOR PLAN SEGMENT A - FIRE PROTECTION
436 FP-G108 GLENRIDGE YARD & SHOP FACILITY - SECOND FLOOR PLAN SEGMENT B - FIRE PROTECTION
437 FP-G109 GLENRIDGE YARD & SHOP FACILITY - SECOND FLOOR PLAN SEGMENT C - FIRE PROTECTION
438 FP-G110 GLENRIDGE YARD & SHOP FACILITY - SECOND FLOOR PLAN SEGMENT D - FIRE PROTECTION
439 FP-G111 GLENRIDGE YARD & SHOP FACILITY - THIRD FLOOR PLAN SEGMENT A - FIRE PROTECTION
440 FP-G112 GLENRIDGE YARD & SHOP FACILITY - THIRD FLOOR PLAN SEGMENT B - FIRE PROTECTION
441 FP-G113 GLENRIDGE YARD & SHOP FACILITY - THIRD FLOOR PLAN SEGMENT C - FIRE PROTECTION
442 FP-G114 GLENRIDGE YARD & SHOP FACILITY - THIRD FLOOR PLAN SEGMENT D - FIRE PROTECTION
443 FP-G115 GLENRIDGE YARD & SHOP FACILITY - THIRD FLOOR PLAN SEGMENT E - FIRE PROTECTION
GLENRIDGE YARD & SHOP FACILITY (CONTINUED)
SHEET 3
DECEMBER 2013




GI-8103
7 NONE
INDEX OF SHEETS - VOLUME 8
GLENRIDGE YARD & SHOP FACILITY - FIRST FLOOR PLAN SEGMENT D - FIRE PROTECTION
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
V
l 1
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
C
R
O
S
S
O
V
E
R
P
S

#
8

S
T
A

T
R
K

1

2
2
2
+
2
0
.
2
1
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

1
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
2
YARD TRK 7
YARD TRK 6
YARD TRK 7
YARD TRK 8
YARD TRK 9
YARD TRK 5 YARD TRK 4
YARD TRK 9
EXISTING CONDITIONS PLAN - SHEET 1 OF 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L01
8 AS SHOWN
LYTTONSVILLE YARD FACILITY
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
T
R
K

1

2
2
3
+
0
0
T
R
K

1

2
2
4
+
0
0
T
R
K

1

2
2
5
+
0
0
T
R
K

1

2
2
6
+
0
0
T
R
K

1

2
2
7
+
0
0
T
R
K

1

2
2
8
+
0
0
T
R
K

1

2
2
9
+
0
0
TRK 1 230+00
TRK 1 231+00
TRK 1 232+00
TRK 1 233+00
TRK 1 234+00
TRK 1 235+00
TRK 1 236+00
T
R
K

2

2
2
3
+
0
0
T
R
K

2

2
2
4
+
0
0
T
R
K

2

2
2
5
+
0
0
T
R
K

2

2
2
6
+
0
0
T
R
K

2

2
2
7
+
0
0
T
R
K

2

2
2
8
+
0
0
T
R
K

2

2
2
9
+
0
0
TRK 2 230+00
TRK 2 231+00
TRK 2 232+00
TRK 2 233+00
TRK 2 234+00
TRK 2 235+00 TRK 2 236+00
UP MP
MH
MH
MP
MH
MH
MH
MH UP
MP
MP
UP
MH
H.B.
MP
MH
MP
UP
MH
MP
UP
MP
MP
MH
MP
MP
UP
MP
MP
MH
UP UP UP
MH
MP
MH
UP
MH
MP
MP
MP MP
MP
MP MP
MH
UP
MP
MP
UP
UP
UP
UP
UP
E
UP
MH
MH
UP
MH
H.B.
UP
UP
UP
UP
MP
UP UP
235
2
4
0
2
4
5
250
255
260
260
260
265
265
265
265
270
270
275
275
275
S
S
S
8
"S
A
N
1
0
"W
1
0
"W
16"W
16"W
1
0
"W
1
0
"W
16"W
8"SAN
8"SAN
W
3
0
"

R
C
P
18" RCP
2
4
"

R
C
P
15" RCP
15" RCP
2
4
"

R
C
P
24" RCP
24" RCP
15" RCP
1
5
"

R
C
P
S
S
S
8
"S
A
N
UP
UP
UP
UP
UP
UP
UP
UP
1
0
"W
1
0
"W
16"W
16"W
1
0
"W
1
0
"W
16"W
8"SAN
8"SAN
6" GAS
6" GAS
6
"
G
A
S
6" GAS
W
UP
UP
UP
UP
UP
UP UP
UP
W
18" PLA
18" PLA
15" CMP
2
1
"

C
M
P
1
8
"

C
M
P
1
8
"
O
TH
E
R
A
A W
N
A
C
C
E
S
S

R
O
A
D
TERRANCE DR
EX CCT
E
X

C
C
T
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX PVMT
EX PVMT
EX TRAILER
E

1
2
9
5
6
5
0
N

4
8
4
3
5
0
E

1
2
9
5
6
5
0
N

4
8
5
0
0
0
E

1
2
9
6
2
5
0
N

4
8
5
0
0
0
N
A
V
A
R
R
E

D
R
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
V
l 1
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

1
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
1
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

2
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
3
YARD TRK 9
YARD TRK 8
YARD TRK 7
YARD TRK 6
YARD TRK 5
YARD TRK 4
YARD TRK 3
YARD TRK 2
YARD TRK 1
YARD TRK 10
EXISTING CONDITIONS PLAN - SHEET 2 OF 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L02
9 AS SHOWN
LYTTONSVILLE YARD FACILITY
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
TRK 1 236+00
TRK 1 237+00
TRK 1 238+00
TRK 1 239+00
TRK 1 240+00 TRK 1 241+00 TRK 1 242+00
TRK 1 243+00
TRK 1 244+00
TRK 1 245+00
TRK 1 246+00
TRK 2 236+00
TRK 2 237+00
TRK 2 238+00
TRK 2 239+00
TRK 2 240+00 TRK 2 241+00 TRK 2 242+00
TRK 2 243+00
TRK 2 245+00
TRK 2 246+00
M P
M P
M P
MP MP
MP
MH
MP MP
MP
MP
MP
MP
MH
MH
MP
UP
MH
MP
MP MP
UP
UP
UP
UP
UP
UP
UP
UP
UP
MP
UP
MH
UP
UP
MP
MH
UP
2
6
0
2
6
5
275
275
275
280
280
2
8
5
285
285
2
9
0
290
2
9
0
290
2
9
5
295
295
295
3
0
0
300
3
0
0
300
300
3
0
5
S
S
S
S
S
S
S
12"SAN
6
" S
A
N
6
"S
AN
6"SAN
8
"S
A
N
6
" S
A
N
6"SAN
6"SAN
16"W
6" GAS
6" GAS
S
GV
S
D
2
7
"

R
C
P
8
"

R
C
P
S
S
S
S
S
S
S
UP
UP
UP
12"SAN
6
" S
A
N
6
"S
AN
6"SAN
8
"S
A
N
6
" S
A
N
6"SAN
6"SAN
16"W
6" GAS
6" GAS
UP
UP
S
UP
UP UP
UP
UP
UP
UP
GV
UP
M
E
T
A
L

C
O
V
E
R
INV
INV
INV
INV
INV
15" RCP
15" RCP
UP
UP
60"RCCP
U
N
K

S
D
U
N
K

S
D
1
8
"
R
C
P
24" RCP
18" RCP
UP
UP
N
BROOKVILLE RD
EX BLDG
EX BLDG
EX BLDG
EX BLDG EX POOL
EX PVMT
EX PVMT
EX PVMT
EX PVMT
EX PVMT
EX PVMT
EX PVMT
EX PVMT
E

1
2
9
6
5
5
0
N

4
8
4
9
0
0
E

1
2
9
6
5
5
0 N

4
8
5
6
5
0
E

1
2
9
7
1
5
0
N

4
8
5
6
5
0
L
Y
T
T
O
N
S
V
IL
L
E

P
L
A
C
E
EX PVMT
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
7
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
V
l 1
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

2
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
2
YARD TRK 1
YARD TRK 7
YARD TRK 8
YARD TRK 6
EXISTING CONDITIONS PLAN - SHEET 3 OF 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L03
10 AS SHOWN
LYTTONSVILLE YARD FACILITY
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
TRK 1 247+00
TRK 1 248+00
TRK 1 249+00
TRK 1 250+00
TRK 1 251+00
TRK 1 252+00
TRK 1 253+00
TRK 1 254+00
TRK 1 255+00 TRK 1 256+00
TRK 1 257+00
TRK 1 258+00
TRK 2 246+00
TRK 2 247+00
TRK 2 248+00
TRK 2 249+00
TRK 2 250+00
TRK 2 251+00
TRK 2 252+00
TRK 2 253+00
TRK 2 254+00
TRK 2 255+00 TRK 2 256+00
TRK 2 257+00
TRK 2 258+00
MP
MP UP
UP
MH
UP
UP
UP
MH
UP
MH
MH
MH
UP
UP
UP
UP
UP
UP
UP
UP
MH
MP
UP
UP
E
MH
UP
MH
MH
MH
MH
MH
UP
UP
MP
UP
UP
UP
MH
H.B.
UP
UP
E
MH
MH
UP
UP
MH
MH
MH
E SIG
UP
SIG
UP
MH
MH
MH
MH
MH
UP
UP
MP
MP
MH
E
MH
MH
285
285
290
290
290
290
295
295
300
300
305
3
0
5
310
310
3
15
315
320
320
G
V
S
12"SAN
8
"S
A
N
8"SAN
8"SAN
8"SAN
8"SAN
8"SAN
10"SAN
16"W
8
"W
16"W
1
0
" W
16"W
UP
UP
UP
UP
UP
UP
10"SAN
S
6" GAS
2
"
G
A
S
6" GAS
4
"
G
A
S
6" GAS
6
"
G
A
S
UP
UP UP
1
4
"
S
T
E
E
L

P
I P
E

E
N
C
A
S
E
M
E
N
T
8
" S
A
N
10"W
10"SAN
SS
SS
SS 1
"
G
A
S
1
. 2
5
"
G
A
S
1.25" GAS
1.25" GAS
16"W
4
"
G
A
S
WV
W
WV
GV
GV
C.O.
4
" S
A
N
4"SAN
SS
SS
SS
SS
SS
S
W
UP
UP UP
W
S
D S
D
15
x
15
21x
21
8
"

R
C
P
G
V
S
UP
UP
UP
UP
UP
12"SAN
8
"S
A
N
8"SAN
8"SAN
8"SAN
8"SAN
8"SAN
10"SAN
16"W
8
"W
16"W
1
0
" W
16"W
UP
UP
UP
UP
UP
UP
10"SAN
S
6" GAS
2
"
G
A
S
6" GAS
4
"
G
A
S
6" GAS
6
"
G
A
S
UP
UP
UP
UP
UP
UP
UP UP
1
4
"
S
T
E
E
L

P
I P
E

E
N
C
A
S
E
M
E
N
T
8
" S
A
N
10"W
10"SAN
SS
SS
SS 1
"
G
A
S
1
. 2
5
"
G
A
S
1.25" GAS
1.25" GAS
16"W
UP
4
"
G
A
S
WV
W
WV
GV
GV
C.O.
UP
UP
4
" S
A
N
4"SAN
SS
SS
SS
SS
SS
S
W
UP
UP UP
UP
UP
UP
UP
UP
UP
UP
W
1
8
" R
C
P
12"RCP
2
1
"R
C
P
18"RCP
1
5
" R
C
P
2
1
"R
C
P
21"R
C
P
1
5
"
R
C
P
15"RCP
15"RCP
15"RCP
15"RCP
1
5
"
R
C
P
MH
U
N
K

S
D
UNK SD
N
BROOKVILLE RD
EX CCT
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX PVMT
EX PVMT EX PVMT EX PVMT
EX PVMT
E

1
2
9
6
9
5
0
N

4
8
5
9
0
0
E

1
2
9
7
3
5
0
N

4
8
5
9
0
0
E

1
2
9
7
3
5
0
N

4
8
6
5
0
0
P
IT
T
M
A
N

D
R
G
A
R
F
IE
L
D

R
D
P
IT
T
M
A
N

D
R
S
IT
T
E
R

A
V
E
S
T
E
W
A
R
T

A
V
E
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
V
l 2
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

1
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
5
REMOVE EXISTING PAVEMENT 1
KEYED NOTES
AND REPLACED BY CONTRACTOR IF DAMAGED.
SHALL BE PRESERVED THROUGH CONSTRUCTION
EXISTING FEATURES DESIGNATED AS "TO REMAIN" 2.
SEE UTILITY PLANS FOR UTILITY DEMOLITION. 1.
DEMOLITION GENERAL NOTES:
1
REMOVE EXISTING PAVEMENT
R REMOVE EXISTING FEATURE
LEGEND
2 REMOVE EXISTING TREES
2
EX. U/G UTILITY TO BE REMOVED
DEMOLITION PLAN - SHEET 1 OF 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L04
11 AS SHOWN
LYTTONSVILLE YARD FACILITY
FOR UTILITY RELOCATION DWGS
SEE UTILITY RELOCATION PLANS
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
T
R
K

1

2
2
9
+
0
0
TRK 1 230+00
TRK 1 231+00
TRK 1 232+00
TRK 1 233+00
TRK 1 234+00
TRK 1 235+00
TRK 1 236+00
T
R
K

2

2
2
9
+
0
0
TRK 2 230+00
TRK 2 231+00
TRK 2 232+00
TRK 2 233+00
TRK 2 234+00
TRK 2 235+00 TRK 2 236+00
MP
H.B.
MP
MH
MH
MP
MH
MP
UP
MP
MH
MP
MP
MP MP
MP
MP MP
MH
MP
UP
UP
UP
UP
E
UP
MH
MH
UP
MH
H.B.
UP
UP
UP
UP
MP
UP UP
8
"S
A
N
1
0
"W
1
0
"W
1
0
"W
1
0
"W
16"W
6" GAS
6" GAS
W
2
4
"

R
C
P
15" RCP
24" RCP
24" RCP
15" RCP
1
5
"

R
C
P
8
"S
A
N
UP
UP
UP
UP
UP
UP
1
0
"W
1
0
"W
1
0
"W
1
0
"W
16"W
6" GAS
6" GAS
W
UP
UP
UP
UP
W
18" PLA
15" CMP
1
8
"
O
TH
E
R
C
C
A W
N
A
C
C
E
S
S

R
O
A
D
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX PVMT
EX PVMT
EX TRAILER
DEMOLITION
YARD
LIMITS OF
R
R
E

1
2
9
6
3
2
0
N

4
8
4
7
2
0
E

1
2
9
6
3
2
0
N

4
8
5
1
1
0
E

1
2
9
5
9
3
0
N

4
8
5
1
1
0
EX FENCE
R
EX TRAILER
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
V
l 2
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

1
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
4
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

2
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
6
STRUCTURAL DRAWINGS)
(SEE ROADWAY &
REMOVE EX BRIDGE
REMOVE EXISTING PAVEMENT 1
KEYED NOTES
AND REPLACED BY CONTRACTOR IF DAMAGED.
SHALL BE PRESERVED THROUGH CONSTRUCTION
EXISTING FEATURES DESIGNATED AS "TO REMAIN" 2.
SEE UTILITY PLANS FOR UTILITY DEMOLITION. 1.
DEMOLITION GENERAL NOTES:
1
REMOVE EXISTING PAVEMENT
R REMOVE EXISTING FEATURE
LEGEND
1
REMOVE EXISTING TREES
2
2
2
2
2
2
EX. U/G UTILITY TO BE REMOVED
DEMOLITION PLAN - SHEET 2 OF 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L05
12 AS SHOWN
LYTTONSVILLE YARD FACILITY
FOR UTILITY RELOCATION DWGS
SEE UTILITY RELOCATION PLANS
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
TRK 1 236+00
TRK 1 237+00
TRK 1 238+00
TRK 1 239+00
TRK 1 240+00 TRK 1 241+00 TRK 1 242+00
TRK 1 243+00
TRK 1 244+00
TRK 1 245+00
TRK 1 246+00
TRK 2 236+00
TRK 2 237+00
TRK 2 238+00
TRK 2 239+00
TRK 2 240+00 TRK 2 241+00 TRK 2 242+00
TRK 2 243+00
TRK 2 245+00
TRK 2 246+00
M P
M P
M P
MP MP
MP
MH
MP MP
MP
MP
MP
MP
MH
MH
MP
UP
MH
MP
MP MP
UP
UP
UP
UP
UP
UP
UP
UP
UP
MP
UP
MH
UP
UP
MP
MH
UP
S
S
S
S
S
S
S
12"SAN
6
" S
A
N
6
"S
AN
6"SAN
8
"S
A
N
6
" S
A
N
6"SAN
6"SAN
16"W
6" GAS
6" GAS
S
GV
S
D
2
7
"

R
C
P
8
"

R
C
P
S
S
S
S
S
S
S
UP
UP
UP
12"SAN
6
" S
A
N
6
"S
AN
6"SAN
8
"S
A
N
6
" S
A
N
6"SAN
6"SAN
16"W
6" GAS
6" GAS
UP
UP
S
UP
UP UP
UP
UP
UP
UP
GV
UP
M
E
T
A
L

C
O
V
E
R
INV
INV
INV
INV
INV
15" RCP
15" RCP
UP
UP
P
.C

C
U
R
V
E

P
IP
E
60"RCCP
U
N
K

S
D
U
N
K

S
D
1
8
"
R
C
P
24" RCP
18" RCP
UP
UP
N
BROOKVILLE RD
EX BLDG
EX BLDG
EX BLDG
EX BLDG EX POOL
EX PVMT
EX PVMT
EX PVMT
EX PVMT
EX PVMT
EX PVMT
EX PVMT
EX PVMT
DEMOLITION
LIMITS OF YARD
CCT
R
L
Y
T
T
O
N
S
V
IL
L
E

P
L
A
C
E
R
E

1
2
9
6
3
7
0
N

4
8
5
2
0
0
E

1
2
9
6
8
4
0
N

4
8
5
2
0
0
E

1
2
9
6
8
4
0
N

4
8
5
7
9
0
E
X

B
L
D
G
R
R EX STORM DRAIN
R
R
EX STORM DRAIN
EX STORM DRAIN
EX STORM DRAIN
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
V
l 2
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

2
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
5
REMOVE EXISTING PAVEMENT 1
KEYED NOTES
AND REPLACED BY CONTRACTOR IF DAMAGED.
SHALL BE PRESERVED THROUGH CONSTRUCTION
EXISTING FEATURES DESIGNATED AS "TO REMAIN" 2.
SEE UTILITY PLANS FOR UTILITY DEMOLITION. 1.
DEMOLITION GENERAL NOTES:
1
1
REMOVE EXISTING PAVEMENT
R REMOVE EXISTING FEATURE
LEGEND
2 REMOVE EXISTING TREES
1
1 2
2
EX. U/G UTILITY TO BE REMOVED
DEMOLITION PLAN - SHEET 3 OF 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L06
13 AS SHOWN
LYTTONSVILLE YARD FACILITY
FOR UTILITY RELOCATOIN DWGS
SEE UTILITY RELOCATOIN PLANS
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
TRK 1 247+00
TRK 1 248+00
TRK 1 249+00
TRK 1 250+00
TRK 1 251+00
TRK 1 252+00
TRK 1 253+00
TRK 1 254+00
TRK 1 255+00 TRK 1 256+00
TRK 1 257+00
TRK 1 258+00
TRK 2 246+00
TRK 2 247+00
TRK 2 248+00
TRK 2 249+00
TRK 2 250+00
TRK 2 251+00
TRK 2 252+00
TRK 2 253+00
TRK 2 254+00
TRK 2 255+00 TRK 2 256+00
TRK 2 257+00
TRK 2 258+00
MP
MP UP
UP
MH
UP
UP
UP
MH
UP
MH
MH
MH
UP
UP
UP
UP
UP
UP
UP
UP
MH
MP
UP
UP
E
MH
UP
MH
MH
MH
MH
MH
UP
UP
MP
UP
UP
UP
MH
H.B.
UP
UP
E
MH
MH
UP
UP
MH
MH
MH
P
L
3
1R
N

4
8
6
6
2
4
.17
7
0
E

12
9
7
3
19
.0
4
5
0
E
L
E
V
. 3
12
.6
8
0
0
E SIG
UP
SIG
UP
MH
MH
MH
MH
MH
UP
UP
MP
MP
MH
E
MH
MH
G
V
S
12"SAN
8
"S
A
N
8"SAN
8"SAN
8"SAN
8"SAN
8"SAN
10"SAN
16"W
8
"W
16"W
1
0
" W
16"W
UP
UP
UP
UP
UP
UP
10"SAN
S
6" GAS
2
"
G
A
S
6" GAS
4
"
G
A
S
6" GAS
6
"
G
A
S
UP
UP UP
1
4
"
S
T
E
E
L

P
I P
E

E
N
C
A
S
E
M
E
N
T
8
" S
A
N
10"W
10"SAN
SS
SS
SS 1
"
G
A
S
1
. 2
5
"
G
A
S
1.25" GAS
1.25" GAS
16"W
4
"
G
A
S
WV
W
WV
GV
GV
C.O.
4
" S
A
N
4"SAN
SS
SS
SS
SS
SS
S
W
UP
UP UP
W
S
D S
D
15
x
15
21x
21
8
"

R
C
P
1
8
" R
C
P
12"RCP
2
1
"R
C
P
18"RCP
1
5
" R
C
P
2
1
"R
C
P
21"R
C
P
1
5
"
R
C
P
15"RCP
15"RCP
15"RCP
15"RCP
1
5
"
R
C
P
MH
U
N
K

S
D
UNK SD
N
BROOKVILLE RD
EX CCT
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX BLDG
EX PVMT
EX PVMT EX PVMT EX PVMT
EX PVMT
P
IT
T
M
A
N

D
R
G
A
R
F
IE
L
D

R
D
P
IT
T
M
A
N

D
R
S
IT
T
E
R

A
V
E
S
T
E
W
A
R
T

A
V
E
R
DEMOLITION
LIMITS OF YARD
E

1
2
9
6
8
5
0
N

4
8
6
0
0
0
E

1
2
9
7
3
4
0
N

4
8
6
0
0
0
E

1
2
9
7
3
4
0
N

4
8
6
4
5
0
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
V
l 4
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

1
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
8
TRK 2 235+00
YARD TRK 9
YARD TRK 7
YARD TRK 5 YARD TRK 4
YARD TRK 9
WEST YARD ENTRANCE
YARD TRK 1
YARD TRK 9
YARD TRK 8
1
KEYED NOTES
2
ALL DIMENSIONS SHOWN ARE IN FEET 4.
DETAILS
REFER TO TRACK PLANS FOR BALLAST AND TRACK 3.
ALL DIMENSIONS SHOWN ARE TO EDGE OF PAVEMENT 2.
ALL RADII ARE SHOWN 5' UNLESS OTHERWISE SHOWN 1.
PLAN NOTES
LEGEND
INSTALL RETAINING WALL. SEE STRUCTURAL PLANS.
3
4
5
FOR WORK OUTSIDE YARD LIMITS.
SEE ALIGNMENT PLANS AND INTERSECTION DETAILS
BALLAST LIMITS
AND TYPICAL SECTIONS FOR MAINTENANCE ROAD AND
SEE LYTTONSVILLE YARD FACILITY ALIGNMENT PLANS
ASSOCIATED WITH LYTTONSVILLE STATION
SEE LYTTONSVILLE STATION PLANS FOR WORK
2
1
4
3
1
2
6
7
ASSEMBLY
INSTALL KEY PASS OPERATED MOTORIZED SLIDE GATE
7
6
PROPOSED CONCRETE
PROPOSED ASPHALT PAVEMENT
INSTALL 6' CHAIN LINK FENCE. SEE DETAILS
SEE ARCHITECTURAL PLANS FOR DETAILS.
INSTALL KEY PASS OPERATED SWING GATE ASSEMBLY.
CIVIL SITE PLAN - SHEET 1 OF 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L07
14 AS SHOWN
LYTTONSVILLE YARD FACILITY
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MP
MH
H.B.
MP
MH
MH
MP
MH
MP
UP
MP
MH
MH
MP
MP
MP MP
MP
MP MP
MH
MP
UP
UP
UP
UP
E
UP
MH
MH
UP
MH
H.B.
UP
UP
UP
MP
UP UP
S
8
"S
A
N
1
0
"W
1
0
"W
1
0
"W
1
0
"W
16"W
6" GAS
6
"
G
A
S
6" GAS
W
2
4
"

R
C
P
15" RCP
24" RCP
24" RCP
15" RCP
1
5
"

R
C
P
18" PLA
1
8
"
O
TH
E
R A
T
R
K

1

2
2
9
+
0
0
TRK 1 230+00
TRK 1 231+00
TRK 1 232+00
TRK 1 233+00
TRK 1 234+00
TRK 1 235+00
TRK 1 236+00
T
R
K

2

2
2
9
+
0
0
TRK 2 230+00
TRK 2 231+00
TRK 2 232+00
TRK 2 233+00
TRK 2 234+00
TRK 2 235+00 TRK 2 236+00
S
8
"S
A
N
UP
UP
UP
UP
UP
UP
1
0
"W
1
0
"W
1
0
"W
1
0
"W
16"W
6" GAS
6
"
G
A
S
6" GAS
W
UP
UP
UP
UP
UP
W
N
A
C
C
E
S
S

R
O
A
D
E

1
2
9
6
2
2
0
N

4
8
4
6
6
0
E

1
2
9
6
2
2
0
N

4
8
5
1
3
0
E

1
2
9
5
8
3
0
N

4
8
5
1
3
0
M P
M P
M P
MP MP
MP
MP MP
MP
MP
MP
MP
MP
UP
MH
MP
MP MP
UP
UP
UP
UP
UP
UP
UP
MP
UP
MH
UP
UP
MP
MH
UP
16"W
6" GAS
6" GAS
UP
UP
60"RCCP
U
N
K

S
D
U
N
K

S
D
TRK 1 236+00
TRK 1 237+00
TRK 1 238+00
TRK 1 239+00
TRK 1 240+00 TRK 1 241+00 TRK 1 242+00
TRK 1 243+00
TRK 1 244+00
TRK 1 245+00
TRK 1 246+00
TRK 2 236+00
TRK 2 237+00
TRK 2 238+00
TRK 2 239+00
TRK 2 240+00 TRK 2 241+00 TRK 2 242+00
TRK 2 243+00
TRK 2 245+00
TRK 2 246+00
AREA 10
LYTTONSVILLE
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
2
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
V
l 4
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
N
BROOKVILLE RD
E

1
2
9
6
5
5
0
N

4
8
4
9
0
0
E

1
2
9
6
5
5
0 N

4
8
5
6
5
0
E

1
2
9
7
1
5
0
N

4
8
5
6
5
0
P
L
A
C
E
L
Y
T
T
O
N
S
V
IL
L
E

R
E
L
O
C
A
T
E
D
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

1
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
9
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

2
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
1
1
YARD TRK 9
YARD TRK 10
YARD TRK 8
YARD TRK 7
YARD TRK 6
YARD TRK 5
YARD TRK 4
YARD TRK 3
YARD TRK 2
YARD TRK 1
TRAIN WASH
DECK
PARKING
BUILDING
OFFICE
1
KEYED NOTES
2
ALL DIMENSIONS SHOWN ARE IN FEET 4.
DETAILS
REFER TO TRACK PLANS FOR BALLAST AND TRACK 3.
ALL DIMENSIONS SHOWN ARE TO EDGE OF PAVEMENT 2.
ALL RADII ARE SHOWN 5' UNLESS OTHERWISE SHOWN 1.
PLAN NOTES
LEGEND
INSTALL RETAINING WALL. SEE STRUCTURAL PLANS.
3
4
5
FOR WORK OUTSIDE YARD LIMITS.
SEE ALIGNMENT PLANS AND INTERSECTION DETAILS
BALLAST LIMITS
AND TYPICAL SECTIONS FOR MAINTENANCE ROAD AND
SEE LYTTONSVILLE YARD FACILITY ALIGNMENT PLANS
ASSOCIATED WITH LYTTONSVILLE STATION
SEE LYTTONSVILLE STATION PLANS FOR WORK
2 1
3
3
3
4
2
PROPOSED ASPHALT PAVEMENT
PROPOSED CONCRETE
CIVIL SITE PLAN - SHEET 2 OF 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L08
15 AS SHOWN
LYTTONSVILLE YARD FACILITY
INSTALL 6' CHAIN LINK FENCE.
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
2
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
V
l 4
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

2
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
0
8
YARD TRK 9
YARD TRK 6
YARD TRK 4
YARD TRK 1
YARD TRK 1
1
KEYED NOTES
2
ALL DIMENSIONS SHOWN ARE IN FEET 4.
DETAILS
REFER TO TRACK PLANS FOR BALLAST AND TRACK 3.
ALL DIMENSIONS SHOWN ARE TO EDGE OF PAVEMENT 2.
ALL RADII ARE SHOWN 5' UNLESS OTHERWISE SHOWN 1.
PLAN NOTES
LEGEND
INSTALL RETAINING WALL. SEE STRUCTURAL PLANS.
3
4
5
FOR WORK OUTSIDE YARD LIMITS.
SEE ALIGNMENT PLANS AND INTERSECTION DETAILS
BALLAST LIMITS
AND TYPICAL SECTIONS FOR MAINTENANCE ROAD AND
SEE LYTTONSVILLE YARD FACILITY ALIGNMENT PLANS
ASSOCIATED WITH LYTTONSVILLE STATION
SEE LYTTONSVILLE STATION PLANS FOR WORK
2
4
3
2
5
1
6
7
ASSEMBLY
INSTALL KEY PASS OPERATED MOTORIZED SLIDE GATE
6
6
SEE ARCHITECTURAL PLANS FOR DETAILS.
INSTALL KEY PASS OPERATED SWING GATE ASSEMBLY.
PROPOSED ASPHALT PAVEMENT
PROPOSED CONCRETE
CIVIL SITE PLAN - SHEET 3 OF 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L09
16 AS SHOWN
LYTTONSVILLE YARD FACILITY
INSTALL 6' CHAIN LINK FENCE.
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MP
MP UP
UP
MH
UP
UP
MH
UP
MH
MH
MH
UP
UP
UP
UP
UP
UP
UP
MH
MP
UP
UP
E
MH
UP
MH
MH
MH
MH
MH
UP
UP
MP
UP
UP
UP
MH
UP
UP
E
MH
MH
UP
UP
MH
MH
MH
E
UP
UP
MH
MH
MH
MH
MH
UP
UP
MP
MP
MH
E
MH
MH
S
D S
D
S
D S
D
8
"

R
C
P
8
"

R
C
P
MH MH
TRK 1 247+00
TRK 1 248+00
TRK 1 249+00
TRK 1 250+00
TRK 1 251+00
TRK 1 252+00
TRK 1 253+00
TRK 1 254+00
TRK 1 255+00 TRK 1 256+00
TRK 1 257+00
TRK 1 258+00
TRK 2 246+00
TRK 2 247+00
TRK 2 248+00
TRK 2 249+00
TRK 2 250+00
TRK 2 251+00
TRK 2 252+00
TRK 2 253+00
TRK 2 254+00
TRK 2 255+00 TRK 2 256+00
TRK 2 257+00
TRK 2 258+00
N
BROOKVILLE RD
E

1
2
9
7
3
5
0
E

1
2
9
7
3
5
0
G
A
R
F
IE
L
D

R
D
P
IT
T
M
A
N

D
R
S
IT
T
E
R

A
V
E
S
T
E
W
A
R
T

A
V
E
N
Y

4
8
5
9
0
0
N
Y

4
8
6
5
0
0
E

1
2
9
6
8
0
0
N

4
8
5
9
0
0
BUNGALOW
SIGNAL
AREA
STORAGE
SUBSTATION
POWER
TRACTION
ENTRANCE
EAST YARD
PLATFORM
LYTTONSVILLE STATION
SAND SILO
BUNGALOW
SIGNAL
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
U
T
l 1
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

1
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
1
1
WEST YARD ENTRANCE
YARD TRK 9
YARD TRK 1
YARD TRK 9
YARD TRK 7
YARD TRK 5 YARD TRK 4
1
KEYED NOTES
2
3
4
WSSC AND MONTGOMERY COUNTY.
REPLACE DISTURBED AREA IN KIND OR AS REQUIRED BY
CONNECT TO EXISTING WATER MAIN AS REQUIRED BY WSSC.
REQUIRED BY WSSC AND MONTGOMERY COUNTY. SEE DETAIL.
REQUIREMENTS. REPLACE DISTURBED AREA IN KIND OR AS
INSTALL FIRE HYDRANT PER WSSC AND MONTGOMERY COUNTY
1
YARD UTILITIES
LIMITS OF
1
4
SEE ARCHITECTURAL PLANS FOR EMERGENCY REPAIR PIT.
SITE / UTILITY PLAN - SHEET 1 of 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L10
17 AS SHOWN
LYTTONSVILLE YARD FACILITY
SEE UTILITY RELOCATION PLANS FOR UTILITY RELOCATION.
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MH
MH
MH
MH UP
MP
MH
H.B.
MP
MH
MH
MP
MP
MH
MP
UP MP
MP
MH
MH
MP
MP
MP MP
MP
MP MP
MH
MP
UP
UP
UP
UP
E
UP
MH
MH
UP
MH
H.B.
UP
UP
UP
MP
UP UP
8
"S
A
N
1
0
"W
1
0
"W
1
0
"W
1
0
"W
16"W
6" GAS
6
"
G
A
S
6" GAS
SS
W W
V
W
WV
2
4
"

R
C
P
15" RCP
15" RCP
24" RCP
24" RCP
15" RCP
1
5
"

R
C
P
18" PLA
1
8
"
O
TH
E
R A
8
"
W
T
R
K

1

2
2
9
+
0
0
TRK 1 230+00
TRK 1 231+00
TRK 1 232+00
TRK 1 233+00
TRK 1 234+00
TRK 1 235+00
TRK 1 236+00
T
R
K

2

2
2
9
+
0
0
TRK 2 230+00
TRK 2 231+00
TRK 2 232+00
TRK 2 233+00
TRK 2 234+00
TRK 2 235+00 TRK 2 236+00
8
"S
A
N
UP
UP
UP
UP
UP
UP
1
0
"W
1
0
"W
1
0
"W
1
0
"W
16"W
6" GAS
6
"
G
A
S
6" GAS
UP
UP
UP
UP
UP
SS
W W
V
W
WV
N
A
C
C
E
S
S

R
O
A
D
E

1
2
9
6
1
6
0
N

4
8
5
0
7
0
E

1
2
9
5
7
8
0
N

4
8
5
0
7
0
E

1
2
9
6
1
6
0
N

4
8
4
6
4
0
R
E
L
O
C
A
T
I
O
N
S
E
W
E
R

S
A
N
I
T
A
R
Y
S
S
M P
M P
M P
MP MP
MP
MP MP
MP
MP
MP
MP
MP
UP
MH
MP
MP MP
UP
UP
UP
UP
UP
UP
UP
MP
UP
MH
UP
UP
MP
MH
UP
2
6
0
2
6
5
275
275
2
8
5
2
9
0
2
9
0
2
9
5
295
3
0
0
300
3
0
0
300
300
3
0
5 2
7
"

R
C
P
60"RCCP
U
N
K

S
D
U
N
K

S
D
S
W
S
S
S
W
W
8"W
8"W
8"W
8
"
W
3"W 3"W
3"W
2"W
4
"
W
2
"
W
6
"
W
6
"
W
6
"
W
8" SAN.
6
"

S
A
N
.
8" SAN.
8
"

S
A
N
.
8" SAN.
UP
UP
UP
12"SAN
6
" S
A
N
6
"S
AN
6"SAN
8
"S
A
N
6
" S
A
N
6"SAN
6"SAN
16"W
6" GAS
6" GAS
UP
UP
UP
UP UP
UP
UP
UP
UP
UP
SS
SS
SS
SS
SS
SS
SS
SS
W
WV
G
GV
UP
UP
S
S
S
TRK 1 236+00
TRK 1 237+00
TRK 1 238+00
TRK 1 239+00
TRK 1 240+00 TRK 1 241+00 TRK 1 242+00
TRK 1 243+00
TRK 1 244+00
TRK 1 245+00
TRK 1 246+00
TRK 2 236+00
TRK 2 237+00
TRK 2 238+00
TRK 2 239+00
TRK 2 240+00 TRK 2 241+00 TRK 2 242+00
TRK 2 243+00
TRK 2 245+00
TRK 2 246+00
AREA 10
LYTTONSVILLE
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
U
T
l 1
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
N
BROOKVILLE RD
E

1
2
9
6
5
5
0
N

4
8
4
9
0
0
E

1
2
9
6
5
5
0 N

4
8
5
6
5
0
E

1
2
9
7
1
5
0
N

4
8
5
6
5
0
P
L
A
C
E
L
Y
T
T
O
N
S
V
IL
L
E

R
E
L
O
C
A
T
E
D
UTILITIES
LIMITS OF YARD
1
1
TO TRAIN WASH
WATER CONNECTION
CONNECTION
SANITARY SEWER
RELOCATION
SANITARY SEWER
RELOCATION
SEWER
SANITARY
1 SEE DETAIL)
(PER WSSC STANDARDS
OIL/WATER SEPERATOR
1,600 GALLON
UTILITIES
LIMITS OF YARD
1
UTILITIES
LIMITS OF YARD
1
UTILITIES
LIMITS OF YARD
1
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

1
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
1
0
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

2
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
1
2
HOSE BIB CONNECTION
TO STATION FOR
WATER LINE
1
(SEE UTILITY DRAWINGS)
UTILITY RELOCATIONS
(SEE UTILITY DRAWINGS)
UTILITY RELOCATIONS
1
(SEE UTILITY DRAWINGS)
UTILITY RELOCATIONS
1
FDC
BUILDING
OFFICE
DECK
PARKING
YARD TRK 10
YARD TRK 9
YARD TRK 8
YARD TRK 7
YARD TRK 6
YARD TRK 5
YARD TRK 4
YARD TRK 3
YARD TRK 2
YARD TRK 1
TRAIN WASH
PL BRIDGE ABUTMENT (TYP)
PROPOSED LYTTONSVILLE
PL BRIDGE ABUTMENT (TYP)
PROPOSED LYTTONSVILLE
40' 40' 0 80'
SCALE: 1"=40'
1
KEYED NOTES
2
3
WSSC AND MONTGOMERY COUNTY.
REPLACE DISTURBED AREA IN KIND OR AS REQUIRED BY
CONNECT TO EXISTING WATER MAIN AS REQUIRED BY WSSC.
REQUIRED BY WSSC AND MONTGOMERY COUNTY. SEE DETAIL.
REQUIREMENTS. REPLACE DISTURBED AREA IN KIND OR AS
INSTALL FIRE HYDRANT PER WSSC AND MONTGOMERY COUNTY
4
3
BOLLARDS
PROVIDE
BOLLARDS
PROVIDE
3
3
BOLLARDS
PROVIDE
4
(PER WSSC STANDARD)
W/ CHECK VAULT
8" FM METER
BOLLARDS
PROVIDE
3
BOLLARDS
PROVIDE
3
BOLLARDS
PROVIDE
3
2
SEE ARCHITECTURAL PLANS FOR EMERGENCY REPAIR PIT.
SITE / UTILITY PLAN - SHEET 2 of 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L11
18 AS SHOWN
LYTTONSVILLE YARD FACILITY
CAPITAL CRESCENT TRAIL
SEE UTILITY RELOCATION PLANS FOR UTILITY RELOCATION.
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
U
T
l 1
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

2
3
+
0
0

-

S
E
E

D
W
G

C
V
-
L
1
1
YARD TRK 1
YARD TRK 4
YARD TRK 6
YARD TRK 9
YARD TRK 1
1
KEYED NOTES
2 SEE ARCHITECTURAL PLANS FOR EMERGENCY REPAIR PIT
3
WSSC AND MONTGOMERY COUNTY.
REPLACE DISTURBED AREA IN KIND OR AS REQUIRED BY
CONNECT TO EXISTING WATER MAIN AS REQUIRED BY WSSC.
REQUIRED BY WSSC AND MONTGOMERY COUNTY. SEE DETAIL.
REQUIREMENTS. REPLACE DISTURBED AREA IN KIND OR AS
INSTALL FIRE HYDRANT PER WSSC AND MONTGOMERY COUNTY
4
3
4
HOSE BIB CONNECTION
TO STATION FOR
WATER LINE
SITE / UTILITY PLAN - SHEET 3 of 3
DECEMBER 2013
BWJ
AKC
AUO

CV-L12
19 AS SHOWN
LYTTONSVILLE YARD FACILITY
SEE UTILITY RELOCATION PLANS FOR UTILITY RELOCATION.
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
MP
MP UP
UP
MH
UP
UP
UP
MH
UP
MH
MH
MH
UP
UP
UP
UP
UP
UP
UP
UP
MH
MP
UP
UP
E
MH
UP
MH
MH
MH
MH
MH
UP
UP
MP
UP
UP
UP
MH
H.B.
UP
UP
E
MH
MH
UP
UP
MH
MH
MH
E SIG
UP
SIG
UP
MH
MH
MH
MH
MH
UP
UP
MP
MP
MH
E
MH
MH
G
V
12"SAN
8
"S
A
N
8"SAN
8"SAN
8"SAN
8"SAN
8"SAN
10"SAN
16"W
8
"W
16"W
1
0
" W
16"W
UP
UP
UP
UP
UP
UP
10"SAN
6" GAS
2
"
G
A
S
6" GAS
4
"
G
A
S
6" GAS
6
"
G
A
S
UP
UP UP
8
" S
A
N
10"W
10"SAN
SS
SS
SS 1
"
G
A
S
1
. 2
5
"
G
A
S
1.25" GAS
1.25" GAS
16"W
4
"
G
A
S
W
GV
4
" S
A
N
4"SAN
SS
SS
SS
SS
SS
W
UP
UP UP
W
WV
W
V
F
H
SS
SS
SS
P
I P
E

E
N
C
A
S
E
M
E
N
T
E
X

1
4
"
S
T
E
E
L

FH
W
V W
GV
W
W
V
S
D S
D
15
x
15
21x
21
8
"

R
C
P
1
8
" R
C
P
12"RCP
2
1
"R
C
P
18"RCP
1
5
" R
C
P
2
1
"R
C
P
21"R
C
P
1
5
"
R
C
P
15"RCP
15"RCP
15"RCP
15"RCP
1
5
"
R
C
P
MH
U
N
K

S
D
UNK SD
8
"
W
8
"
W
8
"
W
8"W
6
"
W
TRK 1 247+00
TRK 1 248+00
TRK 1 249+00
TRK 1 250+00
TRK 1 251+00
TRK 1 252+00
TRK 1 253+00
TRK 1 254+00
TRK 1 255+00 TRK 1 256+00
TRK 1 257+00
TRK 1 258+00
TRK 2 246+00
TRK 2 247+00
TRK 2 248+00
TRK 2 249+00
TRK 2 250+00
TRK 2 251+00
TRK 2 252+00
TRK 2 253+00
TRK 2 254+00
TRK 2 255+00 TRK 2 256+00
TRK 2 257+00
TRK 2 258+00
G
V
UP
UP
UP
UP
UP
12"SAN
8
"S
A
N
8"SAN
8"SAN
8"SAN
8"SAN
8"SAN
10"SAN
16"W
8
"W
16"W
1
0
" W
16"W
UP
UP
UP
UP
UP
UP
10"SAN
6" GAS
2
"
G
A
S
6" GAS
4
"
G
A
S
6" GAS
6
"
G
A
S
UP
UP
UP
UP
UP
UP
UP UP
8
" S
A
N
10"W
10"SAN
SS
SS
SS 1
"
G
A
S
1
. 2
5
"
G
A
S
1.25" GAS
1.25" GAS
16"W
UP
4
"
G
A
S
W
GV
C.O.
UP
UP
#??3425-4416
PEPCO POLE
#784425-5129
PEPCO POLE
#784425-5739
PEPCO POLE
#784425-5522
PEPCO POLE
4
" S
A
N
4"SAN
SS
SS
SS
SS
SS
W
P#785426-3192
P#785425-4682 P#785426-4682
P#785425-2987
UP
UP UP
UP
UP
UP
UP
UP
UP
UP
W
WV
W
V
F
H
SS
SS
SS
C O
P
I P
E

E
N
C
A
S
E
M
E
N
T
E
X

1
4
"
S
T
E
E
L

FH
W
V W
G
GV
W
W
V
E
N
BROOKVILLE RD
EX CCT
E

1
2
9
7
3
5
0
E

1
2
9
7
3
5
0
G
A
R
F
IE
L
D

R
D
P
IT
T
M
A
N

D
R
S
IT
T
E
R

A
V
E
S
T
E
W
A
R
T

A
V
E
1
N
Y

4
8
5
9
0
0
N
Y

4
8
6
5
0
0
E

1
2
9
6
8
0
0
N

4
8
5
9
0
0
UTILITIES
LIMITS OF YARD
1
RELOCATION
SEWER
SANITARY
BUNGALOW
SIGNAL
SILO
SAND
SUBSTATION
POWER
TRACTION
AREA
STORAGE
ENTRANCE
EAST YARD
BUNGALOW
SIGNAL
PLATFORM
LYTTONSVILLE STATION
1
UTILITIES
LIMITS OF YARD
443
S
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
U
T
1
0
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
UTILITY DETAILS
DECEMBER 2013
BWJ
AKC
AUO

CV-L13
20 AS SHOWN
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
M P
M P
M P
MP MP
MP
MP MP
MP
MP
MP
MP
MP
MP
UP
UP
UP
MH
UP
UP
UP
UP
MP
UP
MH
UP
UP
MP
MH
UP
12"SAN
8
"S
A
N
16"W
6" GAS
4
"
G
A
S
6" GAS
6" GAS
WV
GV
2
7
"

R
C
P
S
S
S
S
S
S
UP
UP
UP
12"SAN
6
" S
A
N
6"SAN
8
"S
A
N
6
" S
A
N
6"SAN
6"SAN
16"W
6" GAS
4
"
G
A
S
6" GAS
6" GAS
WV
GV
C.O.
UP
UP
UP UP
UP
UP
UP
UP
UP
UP
UP
P
.C

C
U
R
V
E

P
IP
E
60"RCCP
U
N
K

S
D
U
N
K

S
D
UP
UP
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
V
l 3
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
1
8
.
0
0
'
1
8
.
0
0
'
1
8
.
0
0
'
2
4
.
0
0
'
2
3
.
0
0
'
18.00'
1
8
.
0
0
'
24.00'
6.00'
9.09'
8.00'
6.54'
24.00'
20.97'
8
.
0
0
'
2
3
.
0
0
'
N
BROOKVILLE RD
P
L
A
C
E
L
Y
T
T
O
N
S
V
IL
L
E

R
E
L
O
C
A
T
E
D
E

1
2
9
6
8
4
0
N

4
8
5
8
2
0
E

1
2
9
6
8
4
0
N

4
8
5
1
9
0
E

1
2
9
6
3
7
0
N

4
8
5
1
9
0
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
SPACES REQUIRED FOR MTA
SPACES REQUIRED FOR M.C.
TOTAL SPACES NEEDED
TOTAL SPACES PROVIDED
TOTAL ADA SPACES NEEEDED
VAN SPACES
STANDARD ADA
90
200
290
298
7
2
5
PARKING TABULATION
BUILDING
OFFICE
GARAGE ENTRANCE
TRAIN WASH
30
68
63
5
29
14
23
20
20
13
13
NOTES
WILL MEET ADA REQUIREMENTS.
2. PARKING SPACES 9'x18' UNLESS SPECIFIED. ADA SPACES
DECK LIGHTING
1. SEE PARKING DECK LEVEL PLAN-LIGHTING FOR PARKING
PARKING LAYOUT
DECEMBER 2013
BWJ
AKC
AUO

CV-L14
21 AS SHOWN
LYTTONSVILLE YARD FACILITY
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
2
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
D
R
I 0
9
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

1
3
+
0
0

-

S
E
E

D
W
G

D
R
-
L
0
2
YARD TRK 7
YARD TRK 9
YARD TRK 4
YARD TRK 9
YARD TRK 1
1
KEYED NOTES
SWM & DRAINAGE PLAN - SHEET 1 OF 3
DECEMBER 2013
BWJ
AKC
AUO

DR-L01
22 AS SHOWN
LYTTONSVILLE YARD FACILITY
DRAINAGE DESIGN DWGS.
SEE TRACK SWM & DRAINAGE PLANS FOR SWM &
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MH
MH
MH
MH UP
MP
MH
H.B.
MP
MH
MH
MP
MP
MH
MP
UP
MP
MP
MP
MH
MH
MP
MP
MP MP
MP
MP MP
MH
MP
UP
UP
UP
UP
E
UP
MH
MH
UP
MH
H.B.
UP
UP
UP
MP
UP UP
2
4
"

R
C
P
15" RCP
15" RCP
24" RCP
24" RCP
15" RCP
1
5
"

R
C
P
18" PLA
1
8
"
O
TH
E
R
1
5
"

R
C
P
18" RCP
1
8
"

R
C
P
1
5
"

R
C
P
R
C
P
1
5
"

A
T
R
K

1

2
2
9
+
0
0
TRK 1 230+00
TRK 1 231+00
TRK 1 232+00
TRK 1 233+00
TRK 1 234+00
TRK 1 235+00
TRK 1 236+00
T
R
K

2

2
2
9
+
0
0
TRK 2 230+00
TRK 2 231+00
TRK 2 232+00
TRK 2 233+00
TRK 2 234+00
TRK 2 235+00 TRK 2 236+00
S
W
N
A
C
C
E
S
S

R
O
A
D
1
OUTSIDE OF YARD LIMITS SEE NOTE
FOR SWM & DRAINAGE
SEE TRACK SWM & DRAINAGE PLANS
E

1
2
9
6
2
3
0
N

4
8
4
9
8
0
E

1
2
9
5
9
9
0
N

4
8
4
9
8
0
E

1
2
9
6
2
3
0
N

4
8
4
6
8
0
S
6" GAS
6" GAS
S
2
7
"

R
C
P
6" GAS
6" GAS
GV
UP
UP
P
.C

C
U
R
V
E

P
IP
E
60"RCCP
U
N
K

S
D
U
N
K

S
D
UP
UP
1
8
"

R
C
P
1
8
"

R
C
P
1
5
"

R
C
P
18" RCP
1
8
"

R
C
P
1
8
"

R
C
P
18" RCP
1
5
"

R
C
P
18" RCP 1
5
"

R
C
P
1
8
"

R
C
P
1
5
"

R
C
P
24" RCP
1
5
"

R
C
P
1
5
"

R
C
P
24" RCP
1
5
"

R
C
P
1
5
"

R
C
P
24" RCP
1
5
"

R
C
P
1
5
"

R
C
P
24" RCP
24" RCP
1
5
"

R
C
P 1
5
"

R
C
P
1
5
"

R
C
P
TRK 1 236+00
TRK 1 237+00
TRK 1 238+00
TRK 1 239+00
TRK 1 240+00 TRK 1 241+00 TRK 1 242+00
TRK 1 243+00
TRK 1 244+00
TRK 1 245+00
TRK 1 246+00
TRK 2 236+00
TRK 2 237+00
TRK 2 238+00
TRK 2 239+00
TRK 2 240+00 TRK 2 241+00 TRK 2 242+00
TRK 2 243+00
TRK 2 245+00
TRK 2 246+00
AREA 10
LYTTONSVILLE
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
2
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
D
R
I 0
9
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
N
BROOKVILLE RD
E

1
2
9
6
5
5
0
N

4
8
4
9
0
0
E

1
2
9
6
5
5
0 N

4
8
5
6
5
0
E

1
2
9
7
1
5
0
N

4
8
5
6
5
0
P
L
A
C
E
L
Y
T
T
O
N
S
V
IL
L
E

R
E
L
O
C
A
T
E
D
1
YARD LIMITS. SEE NOTE
FOR SWM & DRAINAGE OUTSIDE OF
SEE TRACK SWM & DRAINAGE PLANS
1 FOR TIE IN LOCATION. SEE NOTE.
SEE TRACK SWM & DRAINAGE PLANS
1
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

1
3
+
0
0

-

S
E
E

D
W
G

D
R
-
L
0
1
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

2
3
+
0
0

-

S
E
E

D
W
G

D
R
-
L
0
3
(FOR CPv & 10-YR)
BOX CULVERT
& 10'W X 12'H X 132'
10'W X 12'H X 186'
UGD-10-01
GREEN ROOFS
PARTIAL
GR-10-01
(ALL FOR WQv)
& 5'W X 12'H X 96' BOX CULVERT
CARTRIDGES (OR APPROVED EQUAL)
WITH 9 - 27" STORM FILTER
10'W X 12'H X 72' BOX CULVERT
STF-10-01
DECK
PARKING
BUILDING
OFFICE
TRAIN WASH
YARD TRK 9
YARD TRK 10
YARD TRK 8
YARD TRK 7
YARD TRK 6
YARD TRK 5
YARD TRK 4
YARD TRK 3
YARD TRK 2
YARD TRK 1
1
KEYED NOTES
SWM & DRAINAGE PLAN - SHEET 2 OF 3
DECEMBER 2013
BWJ
AKC
AUO

DR-L02
23 AS SHOWN
LYTTONSVILLE YARD FACILITY
DRAINAGE DESIGN DWGS.
SEE TRACK SWM & DRAINAGE PLANS FOR SWM &
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
2
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
D
R
I 0
9
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H

L
I
N
E

T
R
K

9

S
T
A

2
3
+
0
0

-

S
E
E

D
W
G

D
R
-
L
O
2
YARD TRK 9
YARD TRK 6
YARD TRK 4
YARD TRK 1
1
KEYED NOTES
SWM & DRAINAGE PLAN - SHEET 3 OF 3
DECEMBER 2013
BWJ
AKC
AUO

DR-L03
24 AS SHOWN
LYTTONSVILLE YARD FACILITY
DRAINAGE DESIGN DWGS.
SEE TRACK SWM & DRAINAGE PLANS FOR SWM &
40' 40' 0 80'
SCALE: 1"=40'
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MP
MP UP
UP
MH
UP
UP
UP
MH
UP
MH
MH
MH
UP
UP
UP
UP
UP
UP
UP
UP
MH
MP
UP
UP
E
MH
UP
MH
MH
MH
MH
MH
UP
UP
MP
UP
UP
UP
MH
H.B.
UP
UP
E
MH
MH
UP
UP
MH
MH
MH
E SIG
UP
SIG
UP
MH
MH
MH
MH
MH
UP
UP
MP
MP
MH
E
MH
MH
S
UP
UP
UP
UP
UP
UP
S
UP
UP UP
SS
SS
SS
W
SS
SS
SS
SS
SS
S
W
UP
UP UP
W
S
D S
D
15
x
15
21x
21
8
"

R
C
P
1
8
" R
C
P
12"RCP
2
1
"R
C
P
18"RCP
1
5
" R
C
P
2
1
"R
C
P
21"R
C
P
1
5
"
R
C
P
15"RCP
15"RCP
15"RCP
15"RCP
1
5
"
R
C
P
MH
U
N
K

S
D
UNK SD
15" RCP
S
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
S
UP
UP
UP
UP
UP
UP
UP UP
SS
SS
SS
UP
W
UP
UP
SS
SS
SS
SS
SS
S
W
UP
UP UP
UP
UP
UP
UP
UP
UP
UP
W
TRK 1 247+00
TRK 1 248+00
TRK 1 249+00
TRK 1 250+00
TRK 1 251+00
TRK 1 252+00
TRK 1 253+00
TRK 1 254+00
TRK 1 255+00 TRK 1 256+00
TRK 1 257+00
TRK 1 258+00
TRK 2 246+00
TRK 2 247+00
TRK 2 248+00
TRK 2 249+00
TRK 2 250+00
TRK 2 251+00
TRK 2 252+00
TRK 2 253+00
TRK 2 254+00
TRK 2 255+00 TRK 2 256+00
TRK 2 257+00
TRK 2 258+00
N
BROOKVILLE RD
E

1
2
9
7
3
5
0
E

1
2
9
7
3
5
0
G
A
R
F
IE
L
D

R
D
P
IT
T
M
A
N

D
R
S
IT
T
E
R

A
V
E
S
T
E
W
A
R
T

A
V
E
1
N
Y

4
8
5
9
0
0
N
Y

4
8
6
5
0
0
E

1
2
9
6
8
0
0
N

4
8
5
9
0
0
YARD LIMITS. SEE NOTE
FOR SWM & DRAINAGE OUTSIDE OF
SEE TRACK SWM & DRAINAGE PLANS
BUNGALOW
SIGNAL
SILO
SAND
BUNGALOW
SIGNAL
AREA
STORAGE
SUBSTATION
POWER
TRACTION
ENTRANCE
EAST YARD
PLATFORM
LYTTONSVILLE STATION
CRESCENT TRAIL
CAPITAL
1
E
X
. R
IG
H
T
-
O
F
-
W
A
Y
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
S
l 1
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
6"
STONE
NO. 57 O.D.
CLASS SE GEOTEXTILE
WRAP NO. 57 STONE W/
SUBBALLAST
BALLAST
SCALE: N.T.S.
EQUIVALENT).
SMOOTH INTERIOR (ADS N-12 OR APPROVED
SLOTTED CORRUGATED PLASTIC PIPE WITH
8"
6" 6"
(MIN.)
12"
8" PERFORATED PVC
MIN. 2% SLOPE MIN. 2% SLOPE
PERFORATED UNDERDRAIN (BELOW ROOFED AREA) DETAIL
6"
STONE
NO. 57 O.D.
CLASS SE GEOTEXTILE
WRAP NO. 57 STONE W/
SUBBALLAST
SCALE: N.T.S.
6" 6"
(MIN.)
12"
MIN. 2% SLOPE MIN. 2% SLOPE
PERFORATED UNDERDRAIN (OPEN AREA) DETAIL
15"
BALLAST
UNDERGROUND SWM CROSS SECTION (YARD STA 14+50)
SCALE: 1"=10'
DRAINAGE DETAILS
DECEMBER 2013
BWJ
AKC
AUO

DR-L04
25 AS SHOWN
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
250
260
270
280
290
300
310
0 20 40 -20 -40 -60 -80 -100
14+50
250
260
270
280
290
300
310
T
R
A
C
K

5
T
R
A
C
K

6
T
R
A
C
K

7
T
R
A
C
K

8
T
R
A
C
K

9
T
R
A
C
K

1
0
10.00'
1
2
.
0
0
'
10.00'
1
2
.
0
0
'
1
2
.
0
0
'
5.00'
(INV.=258.00)
DETENTION
FOR CpV & 10-YR
10'x12' BOX CULVERTS
(INV.=258.00)
FOR WQv DETENTION
5'x12' BOX CULVERT
(TYP.)
UD (TYP.)
UD
(TYP.)
UD
M
A
I
N

L
I
N
E
S
FOR WQv (INV.=258.00)
& STORMFILTERS
10'x12' BOX CULVERT
OCS FOUNDATION
10.00'
1
2
.
0
0
'
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
D
r
a
i n
a
g
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
C
S
l 1
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
B
B
A A
SCALE:"=1'-0"
SCALE:"=1'-0"
SECTION B-B
SCALE:"=1'-0"
SECTION A-A
SPECIFICATIONS:
CONCRETE:
c
s
STEEL:
REINFORCING
1 0
"
#7 @ 12"
3" CL.
SCALE:"=1'-0"
NOTE:
CL
PLAN
GENERAL NOTES:
FIRM SUBGRADE
AGGREGATE ON
BEDDING OF NO. 57
PROVIDE 6" MIN.
C
SECTION C-C
BALLAST SCREEN NOTES:
PER PLANS
INVERT
8
" M
I N
.
OR CLASS V RCCP
15" PERF. UNDERDRAIN
OR CLASS V RCCP
15" PERF. UNDERDRAIN CL
24" CLASS V RCCP
TOP FRAME, GRATE AND BALLAST SCREEN NOT SHOWN FOR CLARITY.
4'-0"
4
' -
0
"
CONCRETE BASE UNIT
EMBEDMENT
4" PIPE
#7 @ 6"
MIX NO. 2 CONCRETE CHANNEL
I.D.
2'-0"
24" CLASS V RCCP
OR CLASS V RCCP
15" PERF. UNDERDRAIN CL
BELL O.D.
2'-11"
BELL I.D.
2'-5"
V
A
R
I E
S
.
ELEV. PER PLANS
TOP OF GRATE
CIRCULAR BALLAST SCREEN DETAIL
CL
OR CLASS V RCCP
15" PERF. UNDERDRAIN
1 0
"
#7 @ 12"
3" CL.
FIRM SUBGRADE
AGGREGATE ON
BEDDING OF NO. 57
PROVIDE 6" MIN.
8
" M
I N
.
EMBEDMENT
4" PIPE
#7 @ 6"
MIX NO. 2 CONCRETE CHANNEL
I.D.
2'-0"
24" CLASS V RCCP
CL
BELL O.D.
2'-11"
BELL I.D.
2'-5"
V
A
R
I E
S
.
ELEV. PER PLANS
TOP OF GRATE
USING NON-SHRINK GROUT.
TO BE GROUTED IN PLACE
OPENING. UNDER DRAIN
OR "DOG HOUSE"
FIELD-CUT CIRCULAR
PRECAST OR
BASE UNIT STRUCTURE CONCRETE SHALL BE MIX NO.6 (4500 PSI).

ONLY GRADE 60 CAN BE USED ON THIS PROJECT.

SHALL HAVE 3" MINIMUM COVER.
BARS AT THE BOTTOM AND SIDES OF ALL FOOTINGS WHICH
UNLESS OTHERWISE NOTED, WITH THE EXCEPTION OF
LAP CHARTS. MINIMUM COVER FOR ANY BAR SHALL BE 2"
ALL SPLICES, NOT SHOWN, SHALL BE LAPPED AS PER BAR
REINFORCING STEEL SHALL CONFORM TO A615, GRADE 60.

REINFORCING STEEL DESIGN: f = 24,000 PSI.

f = 1200 PSI.
CONCRETE DESIGN: SERVICE LOAD DESIGN METHOD

SPECIFICATIONS THROUGH 2000.
DATED 1996 FOR DESIGN, INCLUDING ALL INTERIM
AASHTO STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES

CONSTRUCTION.
AND SPECIAL PROVISIONS FOR MATERIALS AND
REVISIONS THEREOF AND ADDITIONS THERETO

SHA SPECIFICATIONS DATED JANUARY 2001.
DESIGNATION A123.
FABRICATION IN ACCORDANCE WITH ASTM
A-36. SCREEN SHALL BE GALVANIZED AFTER
BE CONSTRUCTED OF STEEL ASTM DESIGNATION
1. FRAME, BALLAST SCREEN AND GRATE SHALL
BELL O.D.
2'-11"
BELL I.D.
2'-5"
BELL O.D.
2'-11"
BELL I.D.
2'-5"
PIPE I.D.
2'-0"
GRATE I.D.
1'-10"
FRAME O.D.
2'-2"
SCREEN
1'-10"
FRAME I.D.
1'-10"
0'-1"
0'-1"
1'-10"
0'-7/8"
0'-3/4"
1'-8"
0
' -
7
" 0
' -
1
"
0
' -
2

"
0'-4"
0
' -
1
"
1'-8"
2'-2"
C
BALLAST
SUBBALLAST
(TYP)
3" CL
(TYP)
3" CL
(M
I N
I M
U
M

P
A
Y

D
E
P
T
H

=

8
' -
0
" )
P
A
Y

D
E
P
T
H
15" PERF. UNDERDRAIN
PLAN - UNDERDRAIN CLEANOUTS
ASPHALT SECTIONS.
SCREEN DETAIL' THIS SHEET. USE SOLID SCREEN THROUGH
ACHIEVE TOP OF GRATE ELEVATION. SEE 'CIRCULAR BALLAST
CIRCULAR BALLAST SCREENS STACKED AS NECESSARY TO
ASPHALT SECTIONS.
SCREEN DETAIL' THIS SHEET. USE SOLID SCREEN THROUGH
ACHIEVE TOP OF GRATE ELEVATION. SEE 'CIRCULAR BALLAST
CIRCULAR BALLAST SCREENS STACKED AS NECESSARY TO
DRAINAGE DETAILS
DECEMBER 2013
BWJ
AKC
AUO

DR-L05
26 AS SHOWN
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
L
a
n
d
s
c
a
p
e

A
r
c
h
i t
e
c
t
u
r
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
L
S
l 0
0
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
40 40 0 80
SCALE: 1"=40
T-1042-0220
PRELIMINARY ENGINEERING
443
2
5
5
2
6
0
2
6
5
275
275
275
275
280
280
285
285
290
2
9
0
290
295
295
295
300
300
H.B.
S
S
S
S
S
S
S
UP
UP
UP
UP
UP
S
UP UP
UP
UP
UP
UP
GV
COMCAST COMCAST
COMCAST
COMCAST
COMCAST
COMCAST COMCAST
UP
S
SS
UP
UP
1602+00
1603+00
1604+00
1605+00
1606+00
8"W
8"W
8"W
8
"
W
3"W 3"W
3"W
8
"
W
1601+00 1602+00
1603+00
1604+00
1605+00
1606+00
1607+00
1608+00
1609+00
TRK 1 234+00
TRK 1 235+00
TRK 1 236+00
TRK 1 237+00
TRK 1 238+00
TRK 1 239+00
TRK 1 240+00 TRK 1 241+00 TRK 1 242+00
TRK 1 243+00
TRK 2 234+00
TRK 2 235+00
TRK 2 236+00
TRK 2 237+00
TRK 2 238+00
TRK 2 239+00
TRK 2 240+00 TRK 2 241+00 TRK 2 242+00
TRK 2 243+00
142+00
143+00
144+00
145+00
146+00
147+00
148+00 149+00
150+00
E

1
2
9
6
5
5
0
N

4
8
4
9
0
0
E

1
2
9
6
5
5
0 N

4
8
5
6
5
0
N
LEGEND
P
BROOKVILLE RD
M
A
T
C
H

L
I
N
E

-

S
E
E

D
W
G

L
S
-
L
0
2
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
DRAINAGE/SYSTEMS/CIVIL DRAWINGS.
POLES AND BOXES REFERENCED ON
DRAINAGE FEATURES AND UTILITY/SYSTEM
3. COORDINATE PLANTINGS WITH ALL SWM/
PLANTINGS BEYOND THE YARD FACILITY.
2. SEE CORRIDOR LANDSCAPE PLAN SET FOR
SEED UNLESS OTHERWISE NOTED.
1. RESEED ALL DISTURBED AREAS WITH TURF
NOTES:
CC TRAIL
TRACK 2
TRACK 1
LYTTONSVILLE YARD TRACKS
PARKING DECK ABOVE
PROPOSED TABLE & CHAIRS
PROPOSED BIKE RACK
PROPOSED FENCE/GATE
PROPOSED SPECIAL PAVING
PROPOSED GREEN ROOF PLANTINGS
ORNAMENTAL GRASSES
PROPOSED GROUNDCOVER/PERENNIALS/
MIXED PLANTINGS
PROPOSED PLANTER WITH
PROPOSED SHRUBS
PROPOSED FLOWERING TREE
PROPOSED EVERGREEN TREE
PROPOSED UPRIGHT SHADE TREE
PROPOSED SHADE TREE
WHERE POSSIBLE
EXISTING TREE TO BE PRESERVED

LANDSCAPE PLAN - SHEET 1 OF 3
DECEMBER 2013
CB/JTT
CO/JM
TLK

LS-L01
27 AS SHOWN
LYTTONSVILLE YARD FACILITY
LANDSCAPING ALONG TRAIL
PACKAGE, DWG LS-12, FOR
SEE CORRIDOR LANDSCAPING
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
8
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
L
a
n
d
s
c
a
p
e

A
r
c
h
i t
e
c
t
u
r
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
L
S
l 0
0
2
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
40 40 0 80
SCALE: 1"=40
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
275
280
2
8
5
285
290
2
9
0
290
2
9
5
295
3
0
0
300
3
0
0
3
0
5
MP
MP
MP MP
MP
MP
MP
MP
MP
MP
MP MP
UP
MH
UP
MH
UP
MH
MH
MH
UP
UP
UP
UP
UP
UP
UP
MP
E
UP
MH
MH
UP
UP
MP
UP
UP
MP
MH
UP
P
I

S
T
A

T
R
K

2

2
5
0
+
0
8
.
1
0
(
9

3
1

3
8
"

D
E
G
R
E
E

C
R
O
S
S
I
N
G

D
I
A
M
O
N
D
)
=

P
I

S
T
A

Y
C

1
+
1
7
.
9
2
(
9

3
1

3
8
"

D
E
G
R
E
E

C
R
O
S
S
I
N
G

D
I
A
M
O
N
D
)
S
W
S
W
W
POE STA. 1059+11.86
1
0
5
5
+
0
0
1
0
5
7
+
0
0
1
0
5
9
+
0
0
1609+00
1610+00
1611+00
1612+00
1613+00
1614+00
1615+00
TRK 1 243+00
TRK 1 244+00
TRK 1 245+00
TRK 1 246+00
TRK 1 247+00
TRK 1 248+00
TRK 1 249+00
TRK 1 250+00
TRK 2 243+00
TRK 2 245+00
TRK 2 246+00
TRK 2 247+00
TRK 2 248+00
TRK 2 249+00
TRK 2 250+00
150+00
151+00
152+00
153+00
154+00
155+00
156+00
157+00
E

1
2
9
7
1
5
0
N

4
8
5
6
5
0
EXISTING POOL
EXISTING PAVEMENT
EXISTING BUILDING
N
L
Y
T
T
O
N
S
V
IL
L
E

P
L
LEGEND
RECEPTACLE
PROPOSED TRASH/RECYCLING
PROPOSED TABLE & CHAIRS
PROPOSED BIKE RACK
PROPOSED FENCE/GATE
PROPOSED SPECIALTY PAVING
PROPOSED GREEN ROOF PLANTINGS
ORNAMENTAL GRASSES
PROPOSED GROUNDCOVER/PERENNIALS/
PROPOSED SHRUBS
PROPOSED FLOWERING TREE
PROPOSED EVERGREEN TREE
PROPOSED UPRIGHT SHADE TREE
PROPOSED SHADE TREE
WHERE POSSIBLE
EXISTING TREE TO BE PRESERVED
P
P
P
P
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
DRAINAGE/SYSTEMS/CIVIL DRAWINGS.
POLES AND BOXES REFERENCED ON
DRAINAGE FEATURES AND UTILITY/SYSTEM
3. COORDINATE PLANTINGS WITH ALL SWM/
PLANTINGS BEYOND THE YARD FACILITY.
2. SEE CORRIDOR LANDSCAPE PLAN SET FOR
SEED UNLESS OTHERWISE NOTED.
1. RESEED ALL DISTURBED AREAS WITH TURF
NOTES:
BROOKVILLE RD
CC TRAIL
TRACK 2
TRACK 1
PLAN LS-L03
SEE ENLARGED DETAIL
M
A
T
C
H

L
I
N
E

-

S
E
E

D
W
G

L
S
-
L
0
1
P
IT
T
M
A
N

D
R
LANDSCAPE PLAN
DRAWING LS1Y01, FOR DETAILED
STATION ARCHITECTURE PACKAGE,
LYTTONSVILLE STATION, SEE

LANDSCAPE PLAN - SHEET 2 OF 3
DECEMBER 2013
CB/JTT
CO/JM
TLK

LS-L02
28 AS SHOWN
LYTTONSVILLE YARD FACILITY
UP
N
LEGEND
L
Y
T
T
O
N
S
V
I
L
L
E

P
L
.
RECEPTACLES
PROPOSED TRASH & RECYCLING
PROPOSED TABLE & CHAIRS
PROPOSED BIKE RACK
PROPOSED FENCE/GATE
PROPOSED SPECIALTY PAVING
GREEN ROOF PLANTINGS
ORNAMENTAL GRASSES
PROPOSED GROUNDCOVER/PERENNIALS/
PROPOSED SHRUBS
PROPOSED FLOWERING TREE
PROPOSED EVERGREEN TREE
PROPOSED UPRIGHT SHADE TREE
PROPOSED SHADE TREE
WHERE POSSIBLE
EXISTING TREE TO BE PRESERVED
SHELTER
BUS
WITH ARCH. PLANS
COORDINATE STEPS
BUS SHELTER
RELOCATED
LOCATION WITH ELEC. PLANS
COORDINATE TRANSFORMER
ADJACENT TO BUILDING
PROPOSED SPECIALTY PAVING
PROPOSED DESIGNATED SMOKING AREA
GREEN ROOF
ROOF
GREEN
ROOF
GREEN
BUILDING
YARD OFFICE
P SCALE:
REF:
2
SHT-REF
1"=1-0"
LS-L03
STACKABLE CHAIR DETAIL
SCALE:
REF:
2
SHT-REF
1"=1-0"
LS-L03
PERFORATED TOP TABLE DETAIL
SEE 3/LS0H01
BIKE RACK,
SCALE:
REF:
1
SHT-REF
"=1-0"
LS-L03
PLANTER WALL DETAIL
RECYCLING RECEPTACLES, AND BIKE RACK DETAILS.
4. SEE LSOHO1 FOR SPECIAL PAVING, TRASH/
DRAWINGS.
REFERENCED ON DRAINAGE/SYSTEMS/CIVIL
FEATURES AND UTILITY/SYSTEM POLES AND BOXES
3. COORDINATE PLANTINGS WITH ALL SWM/DRAINAGE
PLANTINGS BEYOND THE YARD FACILITY.
2. SEE CORRIDOR LANDSCAPE PLAN SET FOR
UNLESS OTHERWISE NOTED.
1. RESEED ALL DISTURBED AREAS WITH TURF SEED
NOTES:
BROOKVILLE RD.

LANDSCAPE PLAN - SHEET 3 OF 3
DECEMBER 2013
CB/JTT
CO/JM
TLK

LS-L03
29 AS SHOWN
LYTTONSVILLE YARD FACILITY
SEE 1/LS-L03
RAISED PLANTER (TYP.)
CIVIL PLANS
COORDINATE WITH
DRAINAGE TO PLANTER
TRENCH DRAIN FOR SCUPPER
SEE LS0H01
RECEPTACLES (TYP.)
TRASH & RECYCLING
SEE DETAIL 2 & 3 / LS-L03
TABLE AND CHAIRS TYP.
SEE 1 / LS-L03
WITH 6 HT. DECORATIVE FENCE
PROPOSED RAISED PLANTER
20 20 0 40
SCALE: 1"=20
T-1042-0220
PRELIMINARY ENGINEERING
P
P
P
UP
MP
UP
TRK 2 245+00
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
4
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
L
a
n
d
s
c
a
p
e

A
r
c
h
i t
e
c
t
u
r
e
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
L
S
l 0
0
3
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
INSTALL PER MANUFACTURER RECOMMENDATIONS
SURFACES, (OR EQUAL)
CHAIR MODEL: SCVIS-AP (VISTA CHAIR) BY FORMS +
PERFORATED BACK CHAIR WITH ARM RESTS B.O.D.
STACKABLE POWDERCOAT SILVER FINISH
443
RECOMMENDATIONS
INSTALL PER MANUFACTURER
BY FORMS + SURFACES, (OR EQUAL)
TABLE MODEL: SPCOL-T30R36 (COLUMN TABLE)
ROUND TOP TABLE (36" TOP, 30" BASE) B.O.D.
POWDERCOAT SILVER FINISH PERFORATED TOP

PARKING DECK STRUCTURE
COORDINATE WALL CONNECTION
NOTE:
PARKING DECK
ON WALL ADJACENT TO BRIDGE
DECORATIVE 6 HT. FENCE,
PLANTING VARIES
A
D
J
A
C
E
N
T
T
O
B
R
ID
G
E
S
T
E
P
P
E
D
T
O
5

1
-
6
"
M
IN
.
WATERPROOFING
LIGHT WEIGHT SOILS
FINISH TO MATCH YARD OFFICE BUIDLING
CONCRETE WALL,
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 1
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
B
R
O
O
K
V
IL
L
E

R
D
TERRACE DR
235
2
4
0
2
4
5
250
255
260
260
260
265
265
265
265
270
270
275
275
275
2
9
5
A
A
= PS #8 STA Y9 0+00
PS #8 STA TRK 2 222+70.21
= PITO #8 STA Y9 0+31.00
PITO #8 STA TRK 2 223+01.21
P
R
O
P
O
S
E
D

D
E
R
A
I
L

S
T
A

Y
9

2
+
0
5
Y1 0+00
Y1 1+00
Y1 2+00
Y1 3+00
Y1 4+00
Y5 0+00
Y5 1+00
Y6 0+00
Y6 1+00
Y7 0+00 Y7 1+00
Y8 0+00
Y8 1+00
Y
9

0
+
0
0
Y
9

1
+
0
0
Y
9

2
+
0
0
Y
9

3
+
0
0
Y
9

4
+
0
0
Y
9

5
+
0
0
Y
9

6
+
0
0
Y9 7+00
Y9 8+00
Y9 9+00
Y9 10+00
Y9 11+00
Y9 12+00
Y9 13+00
Y4 0+00
N
40' 40' 0 80'
SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
M
A
T
C
H

L
I
N
E

S
T
A
.

Y
9

1
3
+
0
0

-

S
E
E

D
W
G

T
W
-
L
0
2
CURVE
RADIUS
(FT)
CN 1 002.1
CN 5 001.1
CN 6 001.1
CN 9 001.1
CN 9 006.1
CN 9 010.1
300
300
300
500
1275
500
CN 9 013.1 400
CURVE PI COORDINATES
NORTH EAST
484864.9326 1296272.1179
485000.2867 1296412.3423
484993.7972 1296436.1495
484698.2076 1295351.7784
484670.6311 1295780.0488
484807.1463 1296209.9850
484970.3174 1296472.2732
ALIGNMENT PLAN - SHEET 1 OF 3
DECEMBER 2013
NRK
NRK
REJ

TW-L01
30 AS SHOWN
LYTTONSVILLE YARD FACILITY
TRACK 1
TRACK 2
ROAD (TYP)
MAINTENANCE
ENTRANCE
WEST YARD
TRAIL
CRESCENT
CAPITAL
(YARD TRACK Y9)
YARD LEAD TRACK
CN 9 001.1
CN 9 006.1
CN 9 010.1
CN 5 001.1
CN 6 001.1
CN 9 013.1
CN 1 002.1
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 1
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
P
IT
T
M
A
N

D
R
BROOKVILLE RD
L
Y
T
T
O
N
S
V
I L
L
E

P
L
Y1 5+00
Y1 6+00
Y1 7+00
Y1 8+00 Y1 9+00 Y1 10+00 Y1 11+00 Y1 12+00
Y1 13+00
Y1 14+00
Y10 0+00
Y10 1+00
Y10 2+00 Y10 3+00 Y10 4+00 Y10 5+00
Y10 6+00
Y10 7+00
Y10 7+31
Y2 0+00 Y2 1+00 Y2 2+00 Y2 3+00 Y2 4+00 Y2 5+00 Y2 6+00
Y2 7+00
Y2 7+49 Y3 0+00 Y3 1+00 Y3 2+00 Y3 3+00 Y3 4+00 Y3 5+00 Y3 6+00 Y3 7+00 Y3 8+00
Y3 9+00
Y5 2+00 Y5 3+00 Y5 4+00 Y5 5+00 Y5 6+00 Y5 7+00 Y5 8+00 Y5 9+00
Y5 10+00
Y5 11+00
Y5 11+28
Y6 1+00 Y6 2+00 Y6 3+00 Y6 4+00 Y6 5+00 Y6 6+00 Y6 7+00 Y6 8+00 Y6 9+00 Y6 10+00
Y6 11+00
Y7 2+00 Y7 3+00 Y7 4+00 Y7 5+00 Y7 6+00 Y7 7+00 Y7 8+00 Y7 9+00 Y7 10+00 Y7 11+00
Y8 1+00
Y8 2+00 Y8 3+00 Y8 4+00 Y8 5+00 Y8 6+00 Y8 7+00 Y8 8+00 Y8 9+00
Y8 10+00
Y8 11+00
Y9 13+00
Y9 14+00
Y9 15+00 Y9 16+00 Y9 17+00 Y9 18+00 Y9 19+00 Y9 20+00 Y9 21+00
Y9 22+00
Y9 23+00
Y4 1+00 Y4 2+00 Y4 3+00 Y4 4+00 Y4 5+00 Y4 6+00 Y4 7+00 Y4 8+00 Y4 9+00
Y4 10+00
PROTECT. FIRE
T.R. UNISEX ROOM BREAK L.R.
OFFICE L.R. STORAGE L.R. MAINT. SUPPLY STORAGE CLEANING STORAGE BULK FLUID
PROTECT. FIRE PROTECT. FIRE
T.R. UNISEX T.R. UNISEX
CORRIDOR
ELEC. COMM. CL.
TRAIN WASH
ROOM LUBE COMPRESSOR/
EMERGENCY PIT
443
40' 40' 0 80'
SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
N
M
A
T
C
H

L
I
N
E

S
T
A
.

Y
9

2
3
+
0
0

-

S
E
E

D
W
G

T
W
-
L
0
3
M
A
T
C
H

L
I
N
E

S
T
A
.

Y
9

1
3
+
0
0

-

S
E
E

D
W
G

T
W
-
L
0
1
CN 1 008.1
CN 1 013.1
CN 2 006.1
CN 3 008.1
CN 4 009.1
CN 5 001.1
300
300
300
300
300
300
CN 5 009.1 300
CN 5 010.1
CN 6 011.1
CN 7 002.1
CN 7 011.1
CN 8 001.1
CN 8 009.1
CN 9 013.1
CN 9 023.1
300
300
300
300
300
300
400
300
800
800
CN 10 001.1
CN 10 005.1
EAST
CURVE PI COORDINATES
NORTH
(FT)
RADIUS
CURVE
485000.2867 1296412.3423
1296472.2732 484970.3174
485323.5758 1296553.7974
485721.6883 1296848.2239
485715.5453 1296866.6904
485734.0861 1296909.0089
1296923.6078
485640.0913
485697.9300 1296924.1624
485765.2712 1297006.6977
485006.4552 1296468.5204
485689.8244 1296973.9102
485007.3012 1296492.1556
485650.5368 1296967.8644
485734.9823 1297033.6298
485127.6397 1296635.2563
485449.0696 1296872.9717
485722.7135
1296885.5136
ALIGNMENT PLAN - SHEET 2 OF 3
DECEMBER 2013
NRK
NRK
REJ

TW-L02
31 AS SHOWN
LYTTONSVILLE YARD FACILITY
ROAD (TYP)
MAINTENANCE
BUNGALOW
SIGNAL
BRIDGE ABUTMENT (TYP)
PROPOSED LYTTONSVILLE PL
BRIDGE PIER (TYP)
PROPOSED LYTTONSVILLE PL
TRACK 1
TRACK 2
TRAIL
CRESCENT
CAPITAL
CN 5 001.1
CN 7 002.1
CN 8 001.1
CN 9 013.1
CN 1 013.1
CN 2 006.1
CN 3 008.1
CN 4 009.1
CN 5 009.1
CN 8 009.1
CN 7 011.1
CN 9 023.1
CN 6 011.1
CN 1 008.1
CN 5 010.1
CN 10 001.1 CN 10 005.1
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 1
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
MH
MH
MH
MH
UP
MH
MH
MH
E
UP
MP
MH
UP
UP
S
T
E
W
A
R
T

A
V
E
BROOKVILLE RD
3
0
0
P
I
T
O

S
T
A

T
R
K

1

2
5
2
+
2
7
.
8
3
P
I
T
O

S
T
A

T
R
K

2

2
5
1
+
9
6
.
8
6
P
I

S
T
A

T
R
K

2

2
5
0
+
0
8
.
1
0
L
Y
T
T
O
N
S
V
I
L
L
E

Y
A
R
D

L
E
A
D
P
S

#
1
0

S
T
A

T
R
K

2

2
5
2
+
2
8
.
2
8
L
Y
T
T
O
N
S
V
I
L
L
E

Y
A
R
D

L
E
A
D
P
S

#
1
0

S
T
A

T
R
K

1

2
5
2
+
5
9
.
2
5
(
9

3
1
'
3
8
"

D
E
G
R
E
E

C
R
O
S
S
I
N
G

D
I
A
M
O
N
D
)
=

P
I
T
O

#
1
0

S
T
A

Y
9

2
8
+
7
8
.
5
2
E
N
D

T
A
I
L

T
R
A
C
K
=

P
S

#

1
0

S
T
A

Y
9

2
9
+
0
9
.
9
4
=

P
I
T
O

#
1
0

S
T
A

Y
C

3
+
3
9
.
7
1
=

P
S

#
1
0

S
T
A

Y
C

3
+
7
1
.
1
3
=

P
I

S
T
A

Y
C

1
+
1
7
.
9
2
(
9

3
1
'
3
8
"

D
E
G
R
E
E

C
R
O
S
S
I
N
G

D
I
A
M
O
N
D
)
TRK 1 246+00
TRK 1 247+00
TRK 1 248+00
TRK 1 249+00
TRK 1 250+00
TRK 1 251+00
TRK 1 252+00
TRK 1 253+00
TRK 1 254+00
TRK 1 255+00 TRK 1 256+00
TRK 1 257+00
TRK 1 258+00
TRK 2 246+00
TRK 2 247+00
TRK 2 248+00
TRK 2 249+00
TRK 2 250+00
TRK 2 251+00
TRK 2 252+00
TRK 2 253+00
TRK 2 254+00
TRK 2 255+00 TRK 2 256+00
TRK 2 257+00
TRK 2 258+00
Y1 15+00
Y1 16+00
Y1 16+92
Y3 9+00
Y3 9+83
Y3 9+83
Y5 11+28
Y6 11+00
Y6 12+00Y6 12+27
Y7 12+00Y7 12+33
Y8 11+00
Y8 11+54
Y9 23+00
Y9 24+00 Y9 25+00 Y9 26+00
Y9 27+00
Y9 28+00 Y9 29+00
Y9 29+10
Y4 11+00
Y4 12+00
40' 40' 0 80'
SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
N
M
A
T
C
H

L
I
N
E

S
T
A
.

Y
9

2
3
+
0
0

-

S
E
E

D
W
G

T
W
-
L
0
2
CURVE
RADIUS
(FT)
NORTH
CURVE PI COORDINATES
EAST
CN C 001.1 300 486180.9987 1297329.7003
ALIGNMENT PLAN - SHEET 3 OF 3
DECEMBER 2013
NRK
NRK
REJ

TW-L03
32 AS SHOWN
LYTTONSVILLE YARD FACILITY
SUBSTATION
TRACTION POWER
AREA
STORAGE
ENTRANCE
EAST YARD
SAND SILO
ROAD (TYP)
MAINTENANCE
STATION PLATFORM
LYTTONSVILLE
BUNGALOW
SIGNAL
TRACK 1
TRACK 2
COMPACTOR
CN C 001.1
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
250
260
270
280
290
300
310
320 320
Y1 0+00 Y1 1+00 Y1 2+00 Y1 3+00 Y1 4+00 Y1 5+00 Y1 6+00 Y1 7+00 Y1 8+00 Y1 9+00 Y1 10+00
P
V
C

S
T
A

Y
1

1
+
2
8
.
6
0
E
L
E
V

2
8
0
.
4
1
P
V
I

S
T
A

Y
1

1
+
7
8
.
6
0
E
L
E
V

2
8
2
.
1
7
P
V
T

S
T
A

Y
1

2
+
2
8
.
6
0
E
L
E
V

2
8
2
.
0
0
P
V
C

S
T
A

Y
1

7
+
5
0
.
0
0
E
L
E
V

2
8
0
.
1
7
P
V
I

S
T
A

Y
1

8
+
0
0
.
0
0
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
1

8
+
5
0
.
0
0
E
L
E
V

2
8
0
.
0
0
3.53%
-0.35%
VC = 100.00
MO = -0.48
R = -3.88
VC = 100.00
MO = 0.04
R = 0.35
0.00%
2
6
2
.
1
2
6
4
.
3
2
6
7
.
7
2
7
4
.
1
2
7
6
.
9
2
7
6
.
5
2
7
6
.
7
2
8
0
.
0
2
8
1
.
3
2
8
2
.
2
2
8
3
.
1
2
8
5
.
2
2
8
7
.
9
2
8
9
.
8
2
9
1
.
3
2
9
3
.
2
2
9
4
.
8
2
9
6
.
0
2
9
7
.
7
2
9
9
.
1
2
9
9
.
8
2
7
5
.
8
7
2
7
7
.
6
4
2
7
9
.
4
0
2
8
1
.
0
8
2
8
1
.
9
4
2
8
1
.
9
2
2
8
1
.
7
5
2
8
1
.
5
7
2
8
1
.
4
0
2
8
1
.
2
2
2
8
1
.
0
5
2
8
0
.
8
7
2
8
0
.
7
0
2
8
0
.
5
2
2
8
0
.
3
5
2
8
0
.
1
7
2
8
0
.
0
4
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
P
S

#
6

S
T
A

Y
1

3
+
0
1
.
6
3

P
S

#
6

S
T
A

Y
1

5
+
1
0
.
1
7
P
S

#
6

S
T
A

Y
1

6
+
4
9
.
1
3
=

S
T
A

Y
9

8
+
4
4
.
6
1
E
L
E
V

2
7
5
.
8
7
P
S

S
T
A

Y
1

0
+
0
0
.
0
0
P
S

#
6

S
T
A

Y
1

3
+
9
8
.
4
0
=

S
T
A

Y
5

0
+
0
0
.
0
0
E
L
E
V

2
8
1
.
7
4
=

S
T
A

Y
4

0
+
0
0
.
0
0
E
L
E
V

2
8
1
.
4
1
=

S
T
A

Y
3

0
+
0
0
.
0
0
E
L
E
V

2
8
1
.
0
1
=

S
T
A

Y
2

0
+
0
0
.
0
0
E
L
E
V

2
8
0
.
5
2
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
250
260
270
280
290
300
310
320 320
PROFILE STA Y1 0+00 TO STA Y1 10+00
DECEMBER 2013
NRK
NRK
REJ

TW-L04
33 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
250
260
270
280
290
300
310
320 320
Y1 10+00 Y1 11+00 Y1 12+00 Y1 13+00 Y1 14+00 Y1 15+00 Y1 16+00 Y1 17+00
P
V
C

S
T
A

Y
1

1
2
+
3
6
.
8
6
E
L
E
V

2
8
0
.
0
0
P
V
I

S
T
A

Y
1

1
2
+
7
4
.
3
6
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
1

1
3
+
1
1
.
8
6
E
L
E
V

2
8
0
.
6
4
E
L
E
V

2
8
7
.
1
1
0.00%
1.70%
VC = 75.00
MO = 0.16
R = 2.27
2
9
9
.
8
2
9
9
.
9
3
0
0
.
0
2
9
8
.
6
2
9
9
.
5
3
0
1
.
9
2
9
8
.
4
2
9
2
.
2
2
9
0
.
6
2
8
9
.
4
2
8
9
.
3
2
8
8
.
6
2
8
4
.
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
2
2
8
0
.
4
5
2
8
1
.
2
9
2
8
2
.
1
4
2
8
2
.
9
9
2
8
3
.
8
4
2
8
4
.
7
0
2
8
5
.
5
5
2
8
6
.
4
0
P
S

#
6

S
T
A

Y
1

1
4
+
0
2
.
7
3
P
S

#
6

S
T
A

Y
1

1
5
+
0
4
.
0
8
P
S

#
6

S
T
A

Y
1

1
6
+
1
5
.
0
2
=

S
T
A

Y
2

7
+
4
8
.
7
5
E
L
E
V

2
8
2
.
1
9
=

S
T
A

Y
3

9
+
8
2
.
7
7
E
L
E
V

2
8
3
.
9
1
=

S
T
A

Y
4

1
1
+
9
9
.
6
4
E
L
E
V

2
8
5
.
8
0
P
S

S
T
A

Y
1

1
6
+
9
1
.
9
8
=

S
T
A

Y
9

2
5
+
4
5
.
7
9
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
250
260
270
280
290
300
310
320 320
PROFILE STA Y1 10+00 TO STA Y1 16+91.98
DECEMBER 2013
NRK
NRK
REJ

TW-L05
34 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
270
280
290
300
310
320 320
270
280
290
300
310
320 320
Y2 0+00 Y2 1+00 Y2 2+00 Y2 3+00 Y2 4+00 Y2 5+00 Y2 6+00 Y2 7+00 Y2 8+00
P
V
C

S
T
A

Y
2

1
+
0
0
.
8
7
E
L
E
V

2
8
0
.
1
8
P
V
I

S
T
A

Y
2

1
+
5
0
.
8
7
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
2

2
+
0
0
.
8
7
E
L
E
V

2
8
0
.
0
0
P
V
C

S
T
A

Y
2

5
+
7
0
.
1
2
E
L
E
V

2
8
0
.
0
0
P
V
I

S
T
A

Y
2

6
+
2
0
.
1
2
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
2

6
+
7
0
.
1
2
E
L
E
V

2
8
0
.
8
5
E
L
E
V

2
8
2
.
1
9
-0.35% -0.00%
1.70%
VC = 100.00
MO = 0.04
R = 0.35
VC = 100.00
MO = 0.21
R = 1.70
2
8
9
.
7
2
9
1
.
1
2
9
2
.
8
2
9
4
.
0
2
9
5
.
8
2
9
7
.
5
2
9
8
.
9
3
0
0
.
3
3
0
0
.
0
3
0
0
.
1
3
0
0
.
4
2
9
4
.
8
3
0
0
.
0
3
0
2
.
6
2
9
8
.
0
2
8
0
.
5
3
2
8
0
.
3
5
2
8
0
.
1
8
2
8
0
.
0
5
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
8
2
8
0
.
5
4
2
8
1
.
3
6
=

S
T
A

Y
1

6
+
4
9
.
1
3
E
L
E
V

2
8
0
.
5
3
P
S

S
T
A

Y
2

7
+
4
8
.
7
5
=

S
T
A

Y
1

1
4
+
0
2
.
7
3
P
S

S
T
A

Y
2

0
+
0
0
.
0
0
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
PROFILE STA Y2 0+00 TO STA Y2 7+48.75
DECEMBER 2013
NRK
NRK
REJ

TW-L06
35 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
0
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
270
280
290
300
310
320 320
270
280
290
300
310
320 320
Y3 0+00 Y3 1+00 Y3 2+00 Y3 3+00 Y3 4+00 Y3 5+00 Y3 6+00 Y3 7+00 Y3 8+00 Y3 9+00 Y3 10+00
P
V
C

S
T
A

Y
3

2
+
3
9
.
8
3
E
L
E
V

2
8
0
.
1
8
P
V
I

S
T
A

Y
3

2
+
8
9
.
8
3
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
3

3
+
3
9
.
8
3
E
L
E
V

2
8
0
.
0
0
P
V
C

S
T
A

Y
3

7
+
0
2
.
5
8
E
L
E
V

2
8
0
.
0
0
P
V
I

S
T
A

Y
3

7
+
5
2
.
5
8
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
3

8
+
0
2
.
5
8
E
L
E
V

2
8
0
.
8
5
E
L
E
V

2
8
3
.
9
1
-0.35%
0.00%
1.70%
VC = 100.00
MO = 0.04
R = 0.35
VC = 100.00
MO = 0.21
R = 1.70
2
8
3
.
3
2
8
5
.
7
2
8
8
.
0
2
8
9
.
4
2
9
1
.
4
2
9
3
.
4
2
9
4
.
6
2
9
4
.
0
2
9
4
.
5
2
9
8
.
1
2
9
9
.
4
2
9
9
.
8
2
9
9
.
9
2
9
5
.
9
2
8
7
.
9
3
0
3
.
2
3
0
3
.
3
2
9
6
.
6
2
9
1
.
7
2
8
9
.
8
2
8
1
.
0
1
2
8
0
.
8
4
2
8
0
.
6
6
2
8
0
.
4
9
2
8
0
.
3
1
2
8
0
.
1
4
2
8
0
.
0
3
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
1
9
2
8
0
.
8
1
2
8
1
.
6
6
2
8
2
.
5
1
2
8
3
.
3
6
=

S
T
A

Y
1

5
+
1
0
.
1
7
E
L
E
V

2
8
1
.
0
1
P
S

S
T
A

Y
3

9
+
8
2
.
7
7
=

S
T
A

Y
1

1
5
+
0
4
.
0
8
P
S

S
T
A

Y
3

0
+
0
0
.
0
0
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
PROFILE STA Y3 0+00 TO STA Y3 9+82.77
DECEMBER 2013
NRK
NRK
REJ

TW-L07
36 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
0
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
270
280
290
300
310
320 320
Y4 0+00 Y4 1+00 Y4 2+00 Y4 3+00 Y4 4+00 Y4 5+00 Y4 6+00 Y4 7+00
P
V
C

S
T
A

Y
4

3
+
5
1
.
6
0
E
L
E
V

2
8
0
.
1
8
P
V
I

S
T
A

Y
4

4
+
0
1
.
6
0
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
4

4
+
5
1
.
6
0
E
L
E
V

2
8
0
.
0
0
-0.35%
-0.00%
VC = 100.00
MO = 0.04
R = 0.35
2
8
2
.
3
2
8
3
.
2
2
8
4
.
2
2
8
7
.
7
2
8
9
.
6
2
9
1
.
2
2
9
0
.
4
2
8
8
.
6
2
8
5
.
6
2
8
6
.
6
2
9
2
.
1
2
9
7
.
0
2
9
7
.
9
2
9
7
.
7
2
9
2
.
9
2
8
1
.
4
1
2
8
1
.
2
3
2
8
1
.
0
6
2
8
0
.
8
8
2
8
0
.
7
1
2
8
0
.
5
3
2
8
0
.
3
6
2
8
0
.
1
8
2
8
0
.
0
5
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
P
S

S
T
A

Y
4

0
+
0
0
.
0
0
=

S
T
A

Y
1

3
+
9
8
.
4
0
E
L
E
V

2
8
1
.
4
1
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
270
280
290
300
310
320 320
PROFILE STA Y4 0+00 TO STA Y4 7+50
DECEMBER 2013
NRK
NRK
REJ

TW-L08
37 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
0
6
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
270
280
290
300
310
320 320
Y4 8+00 Y4 9+00 Y4 10+00 Y4 11+00 Y4 12+00
P
V
C

S
T
A

Y
4

8
+
0
8
.
2
9
E
L
E
V

2
8
0
.
0
0
P
V
I

S
T
A

Y
4

8
+
5
8
.
2
9
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
4

9
+
0
8
.
2
9
E
L
E
V

2
8
0
.
8
5
1.70%
VC = 100.00
MO = 0.21
R = 1.70
2
8
5
.
4
3
0
0
.
6
3
0
4
.
1
2
9
8
.
4
2
9
1
.
0
2
8
9
.
8
2
8
9
.
0
2
8
8
.
7
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
1
5
2
8
0
.
7
1
2
8
1
.
5
6
2
8
2
.
4
1
2
8
3
.
2
6
2
8
4
.
1
1
2
8
4
.
9
6
P
S

#
6

S
T
A

Y
4

1
0
+
3
0
.
4
4
=

S
T
A

Y
5

1
1
+
2
7
.
8
1
E
L
E
V

2
8
2
.
9
3
-0.00%
P
S

S
T
A

Y
4

1
1
+
9
9
.
6
4
=

S
T
A

Y
1

1
6
+
1
5
.
0
2
E
L
E
V

2
8
5
.
8
0
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
270
280
290
300
310
320 320
PROFILE STA Y4 7+50 TO STA Y4 11+99.64
DECEMBER 2013
NRK
NRK
REJ

TW-L09
38 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
0
7
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
260
270
280
290
300
310
320
330 330
260
270
280
290
300
310
320
330 330
Y5 0+00 Y5 1+00 Y5 2+00 Y5 3+00 Y5 4+00 Y5 5+00 Y5 6+00 Y5 7+00 Y5 8+00 Y5 9+00 Y5 10+00 Y5 11+00 Y5 12+00
P
V
C

S
T
A

Y
5

4
+
4
8
.
3
7
E
L
E
V

2
8
0
.
1
8
P
V
I

S
T
A

Y
5

4
+
9
8
.
3
7
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
5

5
+
4
8
.
3
7
E
L
E
V

2
8
0
.
0
0
P
V
C

S
T
A

Y
5

9
+
0
4
.
9
1
E
L
E
V

2
8
0
.
0
0
P
V
I

S
T
A

Y
5

9
+
5
4
.
9
1
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
5

1
0
+
0
4
.
9
1
E
L
E
V

2
8
0
.
8
5
E
L
E
V

2
8
2
.
9
3
-0.35%
-0.00%
1.70%
VC = 100.00
MO = 0.04
R = 0.35
VC = 100.00
MO = 0.21
R = 1.70
2
7
6
.
8
2
7
9
.
8
2
8
1
.
3
2
8
2
.
2
2
8
3
.
1
2
8
3
.
2
2
8
7
.
3
2
8
6
.
7
2
8
5
.
6
2
8
3
.
8
2
8
0
.
7
2
7
8
.
7
2
8
0
.
9
2
8
7
.
0
2
9
0
.
2
2
9
2
.
1
2
9
1
.
6
2
8
8
.
0
2
8
3
.
7
3
0
0
.
9
3
0
4
.
6
2
9
8
.
3
2
9
0
.
9
2
8
1
.
7
4
2
8
1
.
5
7
2
8
1
.
3
9
2
8
1
.
2
2
2
8
1
.
0
4
2
8
0
.
8
7
2
8
0
.
6
9
2
8
0
.
5
2
2
8
0
.
3
4
2
8
0
.
1
7
2
8
0
.
0
4
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
1
7
2
8
0
.
7
7
2
8
1
.
6
2
2
8
2
.
4
7
P
S

S
T
A

Y
5

1
1
+
2
7
.
8
1
=

S
T
A

Y
4

1
1
+
2
7
.
2
1
P
S

S
T
A

Y
5

0
+
0
0
.
0
0
=

S
T
A

Y
1

3
+
0
1
.
6
3
E
L
E
V

2
8
1
.
7
4
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
PROFILE STA Y5 0+00 TO STA Y5 11+27.81
DECEMBER 2013
NRK
NRK
REJ

TW-L10
39 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
0
8
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
260
270
280
290
300
310
320
330 330
Y6 0+00 Y6 1+00 Y6 2+00 Y6 3+00 Y6 4+00 Y6 5+00 Y6 6+00 Y6 7+00
P
V
C

S
T
A

Y
6

4
+
0
7
.
8
2
E
L
E
V

2
8
0
.
1
7
P
V
I

S
T
A

Y
6

4
+
5
7
.
8
2
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
6

5
+
0
7
.
8
2
E
L
E
V

2
8
0
.
0
0
-0.35%
0.00%
VC = 100.00
MO = 0.04
R = 0.35
2
7
7
.
6
2
8
0
.
5
2
8
2
.
1
2
8
2
.
7
2
8
2
.
4
2
8
0
.
8
2
8
0
.
2
2
7
9
.
2
2
7
8
.
3
2
7
7
.
2
2
7
6
.
5
2
7
6
.
3
2
8
0
.
1
2
8
2
.
8
2
8
5
.
2
2
8
4
.
1
2
8
1
.
6
0
2
8
1
.
4
3
2
8
1
.
2
5
2
8
1
.
0
8
2
8
0
.
9
0
2
8
0
.
7
3
2
8
0
.
5
5
2
8
0
.
3
8
2
8
0
.
2
0
2
8
0
.
0
6
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
P
S

S
T
A

Y
6

0
+
0
0
.
0
0
=

S
T
A

Y
7

0
+
9
3
.
6
9
E
L
E
V

2
8
1
.
6
0
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
260
270
280
290
300
310
320
330 330
PROFILE STA Y6 0+00 TO STA Y6 7+50
DECEMBER 2013
NRK
NRK
REJ

TW-L11
40 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
0
9
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
260
270
280
290
300
310
320
330 330
Y6 8+00 Y6 9+00 Y6 10+00 Y6 11+00 Y6 12+00 Y6 13+00
P
V
C

S
T
A

Y
6

8
+
5
4
.
6
7
E
L
E
V

2
8
0
.
0
0
P
V
I

S
T
A

Y
6

9
+
0
4
.
6
7
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
6

9
+
5
4
.
6
7
E
L
E
V

2
8
0
.
8
5
E
L
E
V

2
8
5
.
4
8
1.70%
VC = 100.00
MO = 0.21
R = 1.70
0.00%
2
8
0
.
6
2
8
2
.
8
2
9
9
.
5
3
0
5
.
0
2
9
8
.
4
2
8
9
.
6
2
8
9
.
2
2
8
7
.
5
2
8
5
.
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
1
7
2
8
0
.
7
7
2
8
1
.
6
2
2
8
2
.
4
7
2
8
3
.
3
2
2
8
4
.
1
7
2
8
5
.
0
2
P
S

S
T
A

Y
6

1
2
+
2
6
.
9
2
=

S
T
A

Y
9

2
4
+
4
9
.
8
1
P
S

#
6

S
T
A

Y
6

1
1
+
3
6
.
9
2
=

S
T
A

Y
7

1
2
+
3
3
.
1
7
E
L
E
V

2
8
3
.
9
5
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
260
270
280
290
300
310
320
330 330
PROFILE STA Y6 7+50 TO STA Y6 12+26.92
DECEMBER 2013
NRK
NRK
REJ

TW-L12
41 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
1
0
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
250
260
270
280
290
300
310
320 320
Y7 0+00 Y7 1+00 Y7 2+00 Y7 3+00 Y7 4+00 Y7 5+00 Y7 6+00 Y7 7+00
P
V
C

S
T
A

Y
7

5
+
0
1
.
5
1
E
L
E
V

2
8
0
.
1
7
P
V
I

S
T
A

Y
7

5
+
5
1
.
5
1
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
7

6
+
0
1
.
5
1
E
L
E
V

2
8
0
.
0
0
-0.35%
VC = 100.00
MO = 0.04
R = 0.35
-0.00%
2
6
6
.
4
2
7
1
.
2
2
7
8
.
1
2
8
0
.
6
2
8
2
.
0
2
8
2
.
3
2
8
2
.
0
2
8
0
.
3
2
7
9
.
9
2
7
8
.
8
2
7
7
.
9
2
7
6
.
8
2
7
5
.
9
2
7
6
.
1
2
7
6
.
6
2
8
1
.
9
3
2
8
1
.
7
6
2
8
1
.
5
8
2
8
1
.
4
1
2
8
1
.
2
3
2
8
1
.
0
6
2
8
0
.
8
8
2
8
0
.
7
1
2
8
0
.
5
3
2
8
0
.
3
6
2
8
0
.
1
8
2
8
0
.
0
5
2
8
0
.
0
0
2
8
0
.
0
0
P
S

S
T
A

Y
7

0
+
0
0
.
0
0
=

S
T
A

Y
9

1
1
+
1
3
.
5
4
E
L
E
V

2
8
1
.
9
3
P
S

#
6

S
T
A

Y
7

0
+
9
3
.
6
9
=

S
T
A

Y
6

0
+
0
0
.
0
0
E
L
E
V

2
8
1
.
6
0
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
250
260
270
280
290
300
310
320 320
PROFILE STA Y7 0+00 TO STA Y7 7+00
DECEMBER 2013
NRK
NRK
REJ

TW-L13
42 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
1
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
250
260
270
280
290
300
310
320 320
Y7 7+00 Y7 8+00 Y7 9+00 Y7 10+00 Y7 11+00 Y7 12+00 Y7 13+00
P
V
C

S
T
A

Y
7

9
+
5
0
.
9
2
E
L
E
V

2
8
0
.
0
0
P
V
I

S
T
A

Y
7

1
0
+
0
0
.
9
2
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
7

1
0
+
5
0
.
9
2
E
L
E
V

2
8
0
.
8
5
E
L
E
V

2
8
3
.
9
5
-0.00%
1.70%
VC = 100.00
MO = 0.21
R = 1.70
2
7
7
.
3
2
8
0
.
2
2
7
9
.
9
2
7
8
.
9
2
8
3
.
7
2
9
9
.
7
2
9
5
.
3
2
9
1
.
0
2
8
9
.
1
2
8
9
.
1
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
2
0
2
8
0
.
8
3
2
8
1
.
6
8
2
8
2
.
5
3
2
8
3
.
3
8
P
S

S
T
A

Y
7

1
2
+
3
3
.
1
7
=

S
T
A

Y
6

1
1
+
3
6
.
9
2
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
250
260
270
280
290
300
310
320 320
PROFILE STA Y7 7+00 TO STA Y7 12+33.17
DECEMBER 2013
NRK
NRK
REJ

TW-L14
43 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
1
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
260
270
280
290
300
310 310
260
270
280
290
300
310 310
Y8 0+00 Y8 1+00 Y8 2+00 Y8 3+00 Y8 4+00 Y8 5+00 Y8 6+00 Y8 7+00 Y8 8+00 Y8 9+00 Y8 10+00 Y8 11+00 Y8 12+00
P
V
C

S
T
A

Y
8

4
+
1
1
.
3
1
E
L
E
V

2
8
0
.
1
7
P
V
I

S
T
A

Y
8

4
+
6
1
.
3
1
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
8

5
+
1
1
.
3
1
E
L
E
V

2
8
0
.
0
0
P
V
C

S
T
A

Y
8

8
+
6
5
.
9
7
E
L
E
V

2
8
0
.
0
0
P
V
I

S
T
A

Y
8

9
+
1
5
.
9
7
E
L
E
V

2
8
0
.
0
0
P
V
T

S
T
A

Y
8

9
+
6
5
.
9
7
E
L
E
V

2
8
0
.
8
5
E
L
E
V

2
8
4
.
0
5
-0.35%
0.00%
1.70%
VC = 100.00
MO = 0.04
R = 0.35
VC = 100.00
MO = 0.21
R = 1.70
2
7
2
.
2
2
7
5
.
0
2
7
7
.
8
2
8
1
.
6
2
8
1
.
6
2
8
0
.
6
2
7
9
.
8
2
7
8
.
8
2
7
7
.
7
2
7
6
.
7
2
7
5
.
8
2
7
5
.
8
2
7
6
.
3
2
7
7
.
4
2
7
7
.
9
2
7
8
.
7
2
7
8
.
8
2
7
9
.
6
2
8
8
.
1
2
8
4
.
5
2
8
4
.
2
2
8
6
.
3
2
8
6
.
3
2
8
3
.
9
2
8
1
.
6
1
2
8
1
.
4
4
2
8
1
.
2
6
2
8
1
.
0
9
2
8
0
.
9
1
2
8
0
.
7
4
2
8
0
.
5
6
2
8
0
.
3
9
2
8
0
.
2
1
2
8
0
.
0
7
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
0
0
2
8
0
.
1
0
2
8
0
.
6
0
2
8
1
.
4
3
2
8
2
.
2
8
2
8
3
.
1
3
2
8
3
.
9
8
P
S

S
T
A

Y
8

0
+
0
0
.
0
0
=

S
T
A

Y
9

1
2
+
0
4
.
1
6
E
L
E
V

2
8
1
.
6
1
P
S

S
T
A

Y
8

1
1
+
5
4
.
4
1
=

S
T
A

Y
9

2
3
+
6
6
.
1
8
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
PROFILE STA Y8 0+00 TO STA Y8 11+54.41
DECEMBER 2013
NRK
NRK
REJ

TW-L15
44 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
1
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
230
240
250
260
270
280
290
300
310 310
Y9 0+00 Y9 1+00 Y9 2+00 Y9 3+00 Y9 4+00 Y9 5+00 Y9 6+00 Y9 7+00 Y9 8+00 Y9 9+00 Y9 10+00 Y9 11+00
P
V
C

S
T
A

Y
9

1
+
5
0
.
0
0
E
L
E
V

2
5
1
.
5
9
P
V
I

S
T
A

Y
9

2
+
0
0
.
0
0
E
L
E
V

2
5
3
.
0
8
P
V
T

S
T
A

Y
9

2
+
5
0
.
0
0
E
L
E
V

2
5
4
.
8
5
P
V
C

S
T
A

Y
9

9
+
7
4
.
8
0
E
L
E
V

2
8
0
.
4
7
P
V
I

S
T
A

Y
9

1
0
+
2
4
.
8
0
E
L
E
V

2
8
2
.
2
4
P
V
T

S
T
A

Y
9

1
0
+
7
4
.
8
0
E
L
E
V

2
8
2
.
0
7
3.00%
3.53%
VC = 100.00
MO = 0.07
R = 0.54
VC = 100.00
MO = -0.49
R = -3.88
2
4
4
.
4
2
4
5
.
5
2
4
4
.
6
2
4
1
.
8
2
4
0
.
9
2
4
7
.
6
2
4
8
.
1
2
4
8
.
5
2
4
8
.
8
2
4
9
.
4
2
4
9
.
8
2
5
1
.
5
2
5
1
.
7
2
5
3
.
1
2
5
4
.
8
2
5
8
.
6
2
6
1
.
0
2
6
2
.
3
2
6
3
.
2
2
6
3
.
8
2
6
4
.
9
2
6
8
.
5
2
6
6
.
6
2
4
7
.
0
9
2
4
8
.
5
9
2
5
0
.
0
9
2
5
1
.
5
9
2
5
3
.
1
5
2
5
4
.
8
5
2
5
6
.
6
2
2
5
8
.
3
9
2
6
0
.
1
5
2
6
1
.
9
2
2
6
3
.
6
9
2
6
5
.
4
6
2
6
7
.
2
2
2
6
8
.
9
9
2
7
0
.
7
6
2
7
2
.
5
3
2
7
4
.
2
9
2
7
6
.
0
6
2
7
7
.
8
3
2
7
9
.
6
0
2
8
1
.
2
4
2
8
2
.
0
3
P
S

S
T
A

Y
9

0
+
0
0
.
0
0
=

S
T
A

T
R
K

2
2
2
+
7
0
.
2
1
E
L
E
V

2
4
7
.
0
9
P
S

#
6

S
T
A

Y
9

8
+
4
4
.
6
1
=

S
T
A

Y
1

0
+
0
0
.
0
0
E
L
E
V

2
7
5
.
8
7
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
230
240
250
260
270
280
290
300
310 310
PROFILE STA Y9 0+00 TO STA Y9 11+00
DECEMBER 2013
NRK
NRK
REJ

TW-L16
45 AS SHOWN
LYTTONSVILLE YARD FACILITY
TOP OF RAIL
PROPOSED
GROUND
EXISTING
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
1
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
Y9 11+00 Y9 12+00 Y9 13+00 Y9 14+00 Y9 15+00 Y9 16+00 Y9 17+00 Y9 18+00 Y9 19+00 Y9 20+00 Y9 21+00 Y9 22+00 Y9 23+00
P
V
C

S
T
A

Y
9

1
7
+
8
6
.
2
1
E
L
E
V

2
7
9
.
5
8
P
V
I

S
T
A

Y
9

1
8
+
3
6
.
2
1
E
L
E
V

2
7
9
.
4
0
P
V
T

S
T
A

Y
9

1
8
+
8
6
.
2
1
E
L
E
V

2
7
9
.
6
5
P
V
C

S
T
A

Y
9

2
1
+
5
0
.
6
5
E
L
E
V

2
8
0
.
9
8
P
V
I

S
T
A

Y
9

2
2
+
0
0
.
6
5
E
L
E
V

2
8
1
.
2
3
P
V
T

S
T
A

Y
9

2
2
+
5
0
.
6
5
E
L
E
V

2
8
2
.
0
8
-0.35% 0.50%
VC = 100.00
MO = 0.11
R = 0.85
VC = 100.00
MO = 0.15
R = 1.20
2
6
8
.
6
2
7
2
.
2
2
7
2
.
2
2
7
0
.
1
2
7
2
.
3
2
7
7
.
3
2
8
0
.
7
2
7
9
.
3
2
7
8
.
8
2
7
8
.
4
2
7
7
.
3
2
7
6
.
7
2
7
6
.
1
2
7
6
.
3
2
7
6
.
8
2
7
6
.
6
2
7
6
.
9
2
7
6
.
9
2
7
7
.
9
2
7
8
.
7
2
7
9
.
1
2
7
9
.
8
2
8
0
.
3
2
8
2
.
9
2
8
1
.
9
8
2
8
1
.
8
0
2
8
1
.
6
3
2
8
1
.
4
5
2
8
1
.
2
8
2
8
1
.
1
0
2
8
0
.
9
3
2
8
0
.
7
5
2
8
0
.
5
8
2
8
0
.
4
0
2
8
0
.
2
3
2
8
0
.
0
5
2
7
9
.
8
8
2
7
9
.
7
0
2
7
9
.
5
4
2
7
9
.
5
3
2
7
9
.
7
2
2
7
9
.
9
7
2
8
0
.
2
2
2
8
0
.
4
8
2
8
0
.
7
3
2
8
0
.
9
8
2
8
1
.
3
8
2
8
2
.
0
7
P
S

#
6

S
T
A

Y
9

1
1
+
1
3
.
5
4
P
S

#
6

S
T
A

Y
9

1
2
+
0
4
.
1
6
P
S

#
6

S
T
A

Y
9

1
3
+
9
4
.
6
3
P
S

#
6

S
T
A

Y
9

2
1
+
2
2
.
4
1
=

S
T
A

Y
7

0
+
0
0
.
0
0
E
L
E
V

2
8
1
.
9
3
=

S
T
A

Y
8

0
+
0
0
.
0
0
E
L
E
V

2
8
1
.
6
1
=

S
T
A

Y
1
0

0
+
0
0
.
0
0
E
L
E
V

2
8
0
.
9
5
=

S
T
A

Y
1
0

7
+
3
0
.
6
1
E
L
E
V

2
8
0
.
8
4
PURPLE LINE LIGHT RAIL
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
230
240
250
260
270
280
290
300
310 310
230
240
250
260
270
280
290
300
310 310
PROFILE STA Y9 11+00 TO STA Y9 23+00
DECEMBER 2013
NRK
NRK
REJ

TW-L17
46 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
1
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
230
240
250
260
270
280
290
300
310 310
Y9 23+00 Y9 24+00 Y9 25+00 Y9 26+00 Y9 27+00 Y9 28+00 Y9 29+00 Y9 30+00
E
L
E
V

2
9
3
.
3
2
1.70%
2
8
4
.
2
2
8
4
.
7
2
8
4
.
2
2
8
4
.
2
2
8
4
.
9
2
8
5
.
8
2
8
6
.
5
2
8
7
.
6
2
8
8
.
9
2
8
9
.
4
2
9
0
.
2
2
9
0
.
1
2
8
2
.
9
3
2
8
3
.
7
8
2
8
4
.
6
3
2
8
5
.
4
8
2
8
6
.
3
3
2
8
7
.
1
9
2
8
8
.
0
4
2
8
8
.
8
9
2
8
9
.
7
4
2
9
0
.
5
9
2
9
1
.
4
5
2
9
2
.
3
0
2
9
3
.
1
5
P
S

#
6

S
T
A

Y
9

2
3
+
6
6
.
1
8
P
S

#
6

S
T
A

Y
9

2
4
+
4
9
.
8
1
P
S

#
6

S
T
A

Y
9

2
5
+
4
5
.
7
9
=

S
T
A

T
R
K

2

2
5
2
+
2
8
.
2
8
P
S

S
T
A

Y
9

2
9
+
0
9
.
9
4
=

S
T
A

Y
8

1
1
+
5
4
.
4
1
E
L
E
V

2
8
4
.
0
5
=

S
T
A

Y
6

1
2
+
2
6
.
9
2
E
L
E
V

2
8
5
.
4
8
=

S
T
A

Y
1

1
6
+
9
1
.
9
8
E
L
E
V

2
8
7
.
1
1
PURPLE LINE LIGHT RAIL
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
230
240
250
260
270
280
290
300
310 310
PROFILE STA Y9 23+00 TO STA Y9 29+09.94
DECEMBER 2013
NRK
NRK
REJ

TW-L18
47 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 2
1
6
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
260
270
280
290
300 300
260
270
280
290
300 300
Y10 0+00 Y10 1+00 Y10 2+00 Y10 3+00 Y10 4+00 Y10 5+00 Y10 6+00 Y10 7+00 Y10 8+00
P
V
C

S
T
A

Y
1
0

1
+
9
2
.
2
6
E
L
E
V

2
8
0
.
2
7
P
V
I

S
T
A

Y
1
0

2
+
1
7
.
2
6
E
L
E
V

2
8
0
.
1
9
P
V
T

S
T
A

Y
1
0

2
+
4
2
.
2
6
E
L
E
V

2
8
0
.
1
9
P
V
C

S
T
A

Y
1
0

5
+
7
4
.
6
9
E
L
E
V

2
8
0
.
1
9
P
V
I

S
T
A

Y
1
0

5
+
9
9
.
6
9
E
L
E
V

2
8
0
.
1
9
P
V
T

S
T
A

Y
1
0

6
+
2
4
.
6
9
E
L
E
V

2
8
0
.
3
1
E
L
E
V

2
8
0
.
8
4
-0.35% -0.00% 0.50%
VC = 50.00
MO = 0.02
R = 0.70
VC = 50.00
MO = 0.03
R = 1.00
2
7
6
.
8
2
7
8
.
4
2
7
6
.
5
2
7
6
.
1
2
7
6
.
7
2
7
7
.
8
2
7
6
.
8
2
7
6
.
7
2
7
6
.
5
2
7
6
.
6
2
7
2
.
5
2
7
5
.
5
2
7
6
.
5
2
7
7
.
3
2
7
8
.
6
2
8
0
.
9
5
2
8
0
.
7
7
2
8
0
.
6
0
2
8
0
.
4
2
2
8
0
.
2
5
2
8
0
.
1
9
2
8
0
.
1
9
2
8
0
.
1
9
2
8
0
.
1
9
2
8
0
.
1
9
2
8
0
.
1
9
2
8
0
.
1
9
2
8
0
.
2
2
2
8
0
.
4
4
2
8
0
.
6
9
P
S

S
T
A

Y
1
0

0
+
0
0
.
0
0
=

S
T
A

Y
9

1
3
+
9
4
.
6
3
E
L
E
V

2
8
0
.
9
5
P
S

S
T
A

Y
1
0

7
+
3
0
.
6
1
=

S
T
A

Y
9

2
1
+
2
2
.
4
1
PURPLE LINE LIGHT RAIL
10' 10' 0 20' 40' 40' 0 80'
VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=40'
T-1042-0220
PRELIMINARY ENGINEERING
443
PROFILE STA Y10 0+00 TO STA Y10 7+30.61
DECEMBER 2013
NRK
NRK
REJ

TW-L19
48 AS SHOWN
LYTTONSVILLE YARD FACILITY
GROUND
EXISTING
TOP OF RAIL
PROPOSED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
n
i c
o
l a
s

k
e
r
n
\
d
m
s
9
6
4
1
3
\
1
0
4
2
p
T
W
l 3
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
260
270
280
290
300
310
0 10 20 30 40 50 60 70 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120 -130 -140 -150 -160 -170 -180 -190 -200
260
270
280
290
300
310
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10
18.50' 23.00' 18.50' 18.50' 23.00' 18.50' 18.50' 23.00' 20.50' VARIES VARIES
ROAD (TYP)
MAINTENANCE
PARKING STRUCTURE (TYP)
COLUMNS TO SUPPORT
WALL (TYP)
RETAINING
TYPICAL SECTIONS
SEE MAINLINE
LIMITS OF PARKING STRUCTURE (REFER TO STRUCTURAL DRAWINGS IN VOLUME 8 FOR MORE INFORMATION)
260
270
280
290
300
310
320
0 10 20 30 40 50 60 70 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120 -130 -140 -150 -160 -170 -180 -190 -200
260
270
280
290
300
310
320
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8
VARIES VARIES
Y9 Y10
18.50' 23.00' 18.50' 18.50' 23.00' 18.50' 18.50' 23.00' 13.20'
PARKING STRUCTURE (TYP)
COLUMNS TO SUPPORT
ROAD (TYP)
MAINTENANCE
WALL (TYP)
RETAINING
TYPICAL SECTIONS
SEE MAINLINE
LIMITS OF PARKING STRUCTURE (REFER TO STRUCTURAL DRAWINGS IN VOLUME 8 FOR MORE INFORMATION)
PURPLE LINE LIGHT RAIL
443
10' 10' 0 20'
SCALE: 1"=10'
T-1042-0220
PRELIMINARY ENGINEERING
STA Y9 17+50
STA Y9 20+00
TYPICAL SECTIONS
DECEMBER 2013
NRK
NRK
REJ

TW-L20
49 AS SHOWN
LYTTONSVILLE YARD FACILITY
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
0
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
1X.1
AR
FIN
BRICK
UNITS
CONCRETE MASONRY
UNITS
STRUCTURAL CLAY
PARTITIONS
GYPSUM BOARD
GRADE
WOOD-FINISH
BLOCKING
WOOD
INSULATION
RIGID WALL/PERIMETER
INSULATION
RIGID ROOF
INSULATION
BATT
CONCRETE
FILL
POROUS
EARTH
PATTERN
METAL
NORTH)
(CONSTRUCTION
NORTH ARROW
REVISION
NOTE
NUMBER-DRAWING
FIRE RATING (IN HOURS)
WALL TYPE
SYMBOL
WINDOWNUMBER
SYMBOL
LOUVER NUMBER
SYMBOL
DOOR NUMBER
LEGEND ARCHITECTURAL ABBREVIATIONS
PARTITION TYPES
RMNO
RMNO
SECTIONS)
PLANS AND BUILDING
(REFLECTED CEILING
ROOM NUMBER SYMBOL
(FLOOR PLANS)
ROOM NUMBER SYMBOL
CMU NOMINAL THICKNESS
WALL TYPE VARIANT OR
SYMBOL
BUILDING SECTION
WALL SECTION SYMBOL
REFERENCE SYMBOL
TITLE AND DETAIL
SYMBOL
INTERIOR ELEVATION
ELEVATION SYMBOL
N
(TRUE NORTH)
NORTH ARROW
GRAPHICS VARY AS SHOWN ABOVE
CALLOUT REFERENCE SYMBOL
NUMBER INDICATES DETAIL
SECTION OR ELEVATION
LETTER INDICATES
ELEVATION DESIGNATOR
DETAIL, SECTION OR
ELEVATION IS DRAWN
DETAIL, SECTION OR
DRAWING NUMBER WHERE
EXT EXTERIOR
EXP EXPANSION OR EXPOSED
EXIST EXISTING
EWCA ELECTRIC WATER COOLER - ACCESSIBLE
EWC ELECTRIC WATER COOLER
EW EACH WAY
EUH ELECTRIC UNIT HEATER
EST ESTIMATE
EQUIP EQUIPMENT
EPX EPOXY
EQ EQUAL
EPS EXPANDED POLYSTYRENE
EPDM ETHYLENE-PROPYLENE-DIENE MEMBRANE
EPB ELECTRIC PANEL BOX
EP ETHYLENE PROPYLENE-BASED (SINGLE PLY ROOFING)
EL ELEVATION
EMER EMERGENCY
EM ENTRY MAT
ELEV ELEVATOR
ELEC ELECTRIC OR ELECTRICAL
EJ EXPANSION JOINT
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EFS EXTERIOR FINISH SYSTEM
EF EACH FACE
EA EACH
E EAST
DWG DRAWING
DS DOWNSPOUT
DR DOOR
DO DOOR OPENING
DN DOWN
DIST DISTRICT
DIR DIRECTORY
DIA DIAMETER
DET DETAIL
DEMO DEMOLITION
DEG DEGREE
D DOUBLE
CX CONNECT TO EXISTING
CW CURTAIN WALL
CTR COUNTER
CT CERAMIC TILE
CS CONCRETE SEALER
CONSTR CONSTRUCTION
CSK COUNTERSUNK
CR COLD ROLLED
CONT CONTINUOUS
CONC CONCRETE
COMP COMPACTED
COL COLUMN
CO CLEAR OPENING
CL CENTERLINE
CMU CONCRETE MASONRY UNIT
CMP CORRUGATED METAL PIPE
CLR CLEAR
CLG CEILING
CLOS CLOSET
CJ CONTROL JOINT
CH CEILING HEIGHT
CG CORNER GUARD
CER CERAMIC
CARPT CARPET TILE
CIRC CIRCULATION
CEM CEMENT
CARP CARPET
CAB CABINET
C/C CENTER TO CENTER
C CONDUIT
BLKG BLOCKING
BR BRICK
BR/S BACKER ROD AND SEALANT
BOT BOTTOM
BOS BOTTOM OF STEEL
BM BEAM
BLDG BUILDING
BETW BETWEEN
BD BOARD
BC BOTTOM OF CURB
ASP ASPHALT
AWP ACOUSTICAL WALL PANEL
ARCH ARCHITECTURAL
APPROX APPROXIMATE
APC ACOUSTICAL PANEL CEILING (LAY-IN)
ALUM ALUMINUM
ALT ALTERNATE
AHU AIR HANDLING UNIT
AFF ABOVE FINISHED FLOOR
AF ACCESS FLOOR
AES ABOVE EXISTING SLAB
ADJ ADJACENT
ADD ADDENDUM
ADA AMERICANS WITH DISABILITIES ACT
AD ACCESS DOOR (OR PANEL)
AC AIR CONDITIONING (CONDITIONER)
ABV ABOVE
OZ OUNCE
OPP OPPOSITE
OPNG OPENING
OHG OVERHEAD COILING GRILLE
OP OPERABLE PANEL PARTITION (HUNG)
OHD OVERHEAD COILING DOOR
OFF OFFICE
OD OUTSIDE DIAMETER
OC ON CENTER
OA OVERALL
NO NUMBER
NTS NOT TO SCALE
NOM NOMINAL
NIC NOT IN CONTRACT
ND SANITARY NAPKIN DISPENSER
NA NOT APPLICABLE
N NORTH
MTD MOUNTED
MTL METAL
MR MOP RACK
MP METAL PANEL
MO MASONRY OPENING
MK MARK
MISC MISCELLANEOUS
MIN MINIMUM
MH MANHOLE
MET METAL
MFR MANUFACTURER
MECH MECHANICAL
MFB MINERAL FIBER BLANKET
MDF MEDIUM DENSITY FIBERBOARD
MET METAL
MAX MAXIMUM
MACH MACHINE
MATL MATERIAL
MAS MASONRY
M MIRROR OR MEN
LV LOUVER
LTG LIGHTING
LT LIGHT
LP LOW POINT
LOC LOCATION
LOCK LOCKER
LLV LONG LEG VERTICAL
LIN LINOLEUM FLOOR COVERING
LG LONG
LAV LAVATORY
LAB LABORATORY
L LINTEL
KIT KITCHEN
JT JOINT
JC JANITOR'S CLOSET
J JAMB
IT INFORMATION TECHNOLOGY
INV INVERT
INT INTERIOR
INSUL INSULATION
IN INCH
ID INSIDE DIAMETER
HP HIGH POINT
HOR HORIZONTAL
HTR HEATER
HVAC HEATING, VENTILATING AND AIR CONDITIONING
HW HOT WATER
HT HEIGHT
HR HOUR
HM HOLLOW METAL
HDW HARDWARE
HB HORIZONTAL BLIND
H HEAD
GRT GROUT
GYPBS GYPSUM BOARD SHAFT-WALL ASSEMBLY
GYPB GYPSUM BOARD (WALL OR CEILING)
GVP GYPSUM VENEER PLASTER
GP GYPSUM PLASTER
GL GLASS
GRD GROUND
GMU GLAZED MASONRY UNIT
GLM GLASS UNIT MASONRY (GLASS BLOCK)
GEN GENERAL
GB GRAB BAR
GALV GALVANIZED
GA GAUGE
FTG FOOTING
FWP FABRIC-WRAPPED PANEL (FABRICATED)
FT FOOT OR FEET
FSS FOLDING SHOWER SEAT
FS FOLDING SHELF
FRP FIBERGLASS REINFORCED PLASTIC
FRC FIBER-REINFORCED COATING
FR FIRE RATED
FP FIRE PROOFED
FLR FLOOR
FL FLASHING
FIX FIXTURE
FIRE T FIRE TREATED
FE FIRE EXTINGUISHER ON BRACKET
FC FAN COIL UNIT
FIN FINISH OR FINISHED
FH FLAT HEAD
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FDR FOLDING DOOR (WOOD OR FABRIC)
FD FLOOR DRAIN OR FIRE DAMPER
F FILLER
YR YEAR
YD YARD
WWF WOVEN WIRE FABRIC
WT WEIGHT
WR WATER RESISTANT OR WASTE RECEPTACLE
WOM WALK OFF MAT
WO WINDOW OPENING
WP WATERPROOF OR WORKING POINT
WD WOOD
WHT WHITE
WH WEEP HOLE
WALL COVERING; WALL PAPER)
WC WATER CLOSET OR WALL COVERING (VINYL OR TEXTILE
W/ WITH
W WOMEN, WIDTH, WEST OR WOVEN
VRC VERTICAL RECIPROCATING CONVEYOR
VIF VERIFY IN FIELD
VS VERTICAL STANDPIPE
VP VAPOR BARRIER
VEST VESTIBULE
VERT VERTICAL
VDB VISUAL DISPLAY BOARD (HINGED CONFERENCE UNIT)
VINYL COMPOSITION TILE VCT
VB VINYL BASE
V VENT
UNO UNLESS NOTED OTHERWISE
UR URINAL
TR TREAD
SHOWER: SCREEN)
U UNIT
TYP TYPICAL
TPD TOILET PAPER DISPENSER
TP TOILET PARTITION (WATER CLOSET; URINAL)
TOW TOP OF WALL
TO TOP OF
TEL TELEPHONE
T&G TONGUE & GROOVE
TOS TOP OF STEEL
TH THICK
TER TERRAZZO
TCD TOILET SEAT COVER DISPENSER
TC TOP OF CURB
T&B TOP & BOTTOM
TOB TOWEL BAR
T TILE
SYS SYSTEM
SWR SURFACE-MOUNTED WASTE RECEPTACLE
SUSP SUSPENDED
SUP SUPERVISOR
STRUCT STRUCTURAL OR STRUCTURE
STL STEEL
STAT STATIONARY
SSM SOLID SURFACING MATERIAL
SS STAINLESS STEEL OR SERVICE SINK
SQ SQUARE
SP STAND PIPE
SPEC SPECIFICATION
SND SANITARY NAPKIN DISPOSAL
ALUMINUM: PLASTIC PANEL)
SOD SECTIONAL OVERHEAD DOOR (STEEL;
SJ STEEL JOIST
SIM SIMILAR
SHT SHEET
SH SHOWER
SFT STRUCTURAL FACING TILE
S/F STOREFRONT
SF SQUARE FOOT
SECT SECTION
SCR SHOWER CURTAIN ROD
SD SOAP DISPENSER OR STORM DRAIN
SC SPECIAL COATING (OTHER THAN PAINT SYSTEMS)
SCH SCHEDULE OR SCHEDULED
S SILL, SOUTH OR SINGLE
RX REMOVE EXISTING
RV ROOF VENT
RWR RECESSED WASTE RECEPTACLE
RUB RUBBER
RO ROUGH OPENING
RMNO ROOM NUMBER
RM ROOM
RH ROBE HOOK
REV REVISION
RET RETURN
REQ REQUIRED
RESF RESINOUS FLOORING
REINF REINFORCED OR REINFORCING
REBAR REINFORCING BAR
RF RESILIENT FLOORING (VINYL, RUBBER)
RCP REFLECTED CEILING PLAN
REQ'D REQUIRED
RD ROOF DRAIN OR ROUND
RB RUBBER BASE
R RISER OR RADIUS
QTY QUANTITY
QT QUARRY TILE
PVC POLYVINYL CHLORIDE
PTN PARTITION
PTD PAPER TOWEL DISPENSER
PT PAINT
PRES T PRESSURE TREATED
PREFAB PREFABRICATED
POC POLISHED CONCRETE
PLAS PLASTER
PLAM PLASTIC LAMINATE
PL PLATE
PF PLASTIC FABRICATION
PC PRECAST CONCRETE
PAV PAVER TILE (FROM OVERHEAD TRACK)
ARCHITECTURAL ABBREVIATIONS AND LEGEND
DECEMBER 2013
RJH
RJH
DAK

AR-L01
50 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
0
2
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
GENERAL NOTES
APPARATUS ACCESS POINT.
450 FEET FROM A FIRE DEPARTMENT
BUILDING FOOTPRINT IS MORE THAN
CODE 29-08AM NO PORTION OF
IN ACCORDANCE WITH FIRE SAFETY 1.
SCALE:
YARD LEVEL CODE ANALYSIS PLAN
SCALE:
DECK LEVEL CODE ANALYSIS
1" = 40'
1" = 40'
N
40' 40' 0 80'
SCALE: 1"=40'
BUILDING CODE INFORMATION
1 HR ROOF CONSTRUCTION: 4.
1 HR FLOOR CONSTRUCTION: 3.
ADJACENT USE > 15' AND < 20')
0 HR (DISTANCE FROM EXTERIOR NON-BEARING WALLS: 2.
1 HR PRIMARY STRUCTURAL FRAME: 1.
601)
FIRE-RESISTANCE RATING RQMTS. FOR BUILDING ELEMENTS (TABLE F.
BETWEEN TYPE B AND TYPE S-2: 1 HR WITH SPRINKLERS 1.
SEPARATION OF USE GROUPS: E.
250' USE (S-2) WITH SPRINKLER:
300' USE (B) WITH SPRINKLER SYSTEM:
ALLOWABLE TRAVEL DISTANCE: 4.
PROVIDED CORRIDOR WIDTH: USE B: 48" (4'-0")
PROVIDED DOOR WIDTH: USE B: 72" (6'-0")
REQD. DOORS/CORRIDORS WIDTH: (0.2 x OCC.) = 24" (2'-0")
SECOND FLOOR OCCUPANTS, USE B:78 3.
PROVIDED CORRIDOR WIDTH: USE B: 48" (4'-0")
PROVIDED DOOR WIDTH: USE B: 216" (18'-0"), USE S-2: N/A
REQD. DOORS/CORRIDORS WIDTH: (0.2 x OCC.) = 24" (2'-0")
FIRST FLOOR OCCUPANTS, USE B: 116, USE S-2: 311 2.
SYSTEM
AUTOMATIC SPRINKLER AND EMERGENCY VOICE/ALARM COMM. 1.
OCCUPANCY AND EGRESS: D.
TOTAL STORAGE: 311 6.
TOTAL BUSINESS: 194 5.
SECOND FLOOR BUSINESS: 7,765 SF/100 GROSS = 78 4.
FIRST FLOOR STORAGE S-2: 93,280 SF/300 GROSS = 311 3.
FIRST FLOOR BUSINESS: 11,540 SF/100 GROSS = 116 2.
YARD: N/A 1.
OCCUPANCY CALCULATION: C.
SECOND FLOOR SQUARE FOOTAGE: 7,765 SF 8.
FIRST FLOOR SQUARE FOOTAGE: 11,540 SF 7.
YARD LEVEL SQUARE FOOTAGE: 117,000 SF 6.
SUM OF RATIOS: .92 < 1.0 (SEE SECTION 508.4.2)
B: 11,540/123,725 = .092
S-2: 117,000/142,350 = .82
RATIO OF AREA PROVIDED BY USE: 5.
11,540 SF FLOOR AREA PROVIDED:
123,725 SF TOTAL INCREASE ALLOWED:
75,000 SF SPRINKLER INCREASE(200%):
11,250 SF FRONTAGE INCREASE(30%):
37,500 SF ALLOWABLE AREA, USE B: 4.
117,000 SF FLOOR AREA PROVIDED:
142,350 SF TOTAL INCREASE ALLOWED:
78,000 SF SPRINKLER INCREASE(200%):
25,350 SF FRONTAGE INCREASE(65%):
39,000 SF ALLOWABLE AREA, USE S-2: 3.
& S-2, LIGHT-HAZARD STORAGE
OCCUPANCY CLASSIFICATION: SEPARATED MIXED USE, B, BUSINESS 2.
IIA (PROTECTED) CONSTRUCTION TYPE: 1.
BUILDING HEIGHTS AND AREA: B.
COMAR 05.02.02 ADDAAG 1994 ACCESSIBILITY: 4.
AMENDMENTS
2012 NFPA101W/ MONTGOMERY CO. LIFE SAFETY CODE: 3.
2007 NFPA 13 SPRINKLER SYSTEM: 2.
MONTGOMERY CO. AMENDMENTS
2012 INTERNATIONAL BUILDING CODE W/ BUILDING CODE: 1.
APPLICABLE CODES: A.
CODE ANALYSIS - YARD AND DECK LEVELS
DECEMBER 2013
RJH
RJH
DAK

AR-L02
51 1"=40'
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these T-1042-0220
PRELIMINARY ENGINEERING
443
ELEC. SERVICE
WATER SERVICE STORAGE
BULK FLUID
LIGHT RAIL VEHICLE YARD
E-1
E-2
UNISEX TOILET ROOM
L.R. MAINT. STOR.
L.R. OFFICE
L.R. BREAK ROOM SUPPLY STOR.
CLEANING
ELEC. ROOM
UNISEX TOILET ROOM
UNISEX TOILET ROOM
CLEANING BREAK ROOM
CLEANING OFFICE
ELEC. SERVICE
EMERGENCY
STAIR S2
PROTECTION
FIRE
PROTECTION
FIRE
COMPRESSOR ROOM
E-3
ELEVATOR LOBBY
EMERGENCY REPAIR PIT 1 HR
S-2
B
ENCLOSURE
1 HR FIRE PARTITION/
LEGEND
E-1
E-2
ACCESS RAMP
VEHICLE
STAIR S4
STAIR S1
EGRESS RAMP/STAIRS
EMERGENCY
250'-0"
2
5
0
'
-
0
"
2
5
0
'
-
0
"
250'-0"
S-2
B
KEY PLAN
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
0
3
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SCALE:
WASH BUILDING CODE ANALYSIS
" = 1'-0"
N
12' 12' 0 24'
SCALE:"=1'-0"
BUILDING CODE INFORMATION
1 HR SEPARATION REQUIRED BETWEEN WASH BUILDING AND EGRESS STAIR. G.
1 HR ROOF CONSTRUCTION: 4.
1 HR FLOOR CONSTRUCTION: 3.
0 HR (DISTANCE FROM ADJACENT USE > 15' AND < 20') EXTERIOR NON-BEARING WALLS: 2.
1 HR PRIMARY STRUCTURAL FRAME: 1.
FIRE-RESISTANCE RATING RQMTS. FOR BUILDING ELEMENTS (TABLE 601) F.
N/A SEPARATION OF USE GROUPS: E.
USE (S-2) WITH SPRINKLER: 250'
ALLOWABLE TRAVEL DISTANCE: 3.
PROVIDED CORRIDOR WIDTH: USE B: 48"(4'-0")
PROVIDED DOOR WIDTH: 144" (12'-0")
REQD. DOORS/CORRIDORS WIDTH: (0.2 x OCC.)= 2.4"
FIRST FLOOR OCCUPANTS: 12 2.
AUTOMATIC SPRINKLER AND EMERGENCY VOICE/ALARM COMM. SYSTEM 1.
OCCUPANCY AND EGRESS: D.
N/A OCCUPANCY CALCULATION: C.
3,695 SF AREA PROVIDED:
39,000 SF ALLOWABLE AREA, USE S-2: 3.
S-2, LIGHT-HAZARD STORAGE OCCUPANCY CLASSIFICATION: 2.
IIA (PROTECTED) CONSTRUCTION TYPE: 1.
BUILDING HEIGHTS AND AREA: B.
COMAR 05.02.02 ADDAAG 1994 ACCESSIBILITY: 4.
2012 NFPA101 W/ MONTGOMERY CO. AMENDMENTS LIFE SAFETY CODE: 3.
2007 NFPA 13 SPRINKLER SYSTEM: 2.
2012 INTERNATIONAL BUILDING CODE W/ MONTGOMERY CO. AMENDMENTS BUILDING CODE: 1.
APPLICABLE CODES: A.
CODE ANALYSIS - WASH BUILDING
DECEMBER 2013
RJH
RJH
DAK

AR-L03
52 3/32"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
WASH BAY
ELEC. CLOSET
COMM.
S-2
PARTITION/ENCLOSURE
1 HOUR FIRE
LEGEND
KEY PLAN
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
0
4
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SCALE: "=1'-0"
OFFICE FIRST FLOOR CODE ANALYSIS
SCALE: "=1'-0"
OFFICE SECOND FLOOR CODE ANALYSIS
12' 12' 0 24'
SCALE:"=1'-0"
CODE ANALYSIS - OFFICE 1ST AND 2ND FLOORS
DECEMBER 2013
RJH
RJH
DAK

AR-L04
53 3/32"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
MECH.
I.T.
DISPATCH
EQUIPMENT
CONTROL CENTER
OPERATIONS
TECHNICIANS
COPY
ADMIN./
EQUIP.
ELEC.
ROOM
TEAM
CL.
JAN.
MAINT.
BLDG.
SUPER.
TRANS.
SUPER.
TRANS.
ASST.
LOBBY
MASTER
YARD
ROOM
INCIDENT
ROOM
QUIET
T.R.
LOCKERS
T.R.
T.R.
COORD.
BLOCK
WORK
SUPER. T.R. OFFICE
PLAZA
LANDSCAPED
ROOF
VEGETATED
STAIR S2
E-3
T.R.
STAIR S3
ROOM/KITCHENETTE
OPERATOR BREAK
ROOM
TEAM
= 122'
DISTANCE
TRAVEL
= 156'
DISTANCE
TRAVEL
= 58'
DISTANCE
TRAVEL
= 70'
DISTANCE
PATH
COMMON
= 30'
DISTANCE
PATH
COMMON
= 240'
DISTANCE
TRAVEL
STAIR S3
STAIR S2
ROOF
VEGETATED
ROOF
VEGETATED
METAL ROOF
METAL ROOF
STAIR S3
STAIR S2
ROOF
VEGETATED
ROOF
VEGETATED
METAL ROOF
METAL ROOF
CLASSROOM
STOR.
CL.
JAN.
OFFICE
TRAINING
T.R.
T.R.
T.R.
MECH.
ELEC.
ROOM
COMM.
I.T.
LOBBY
ELEV.
E-3
DIRECTOR
L.R.
DIRECTOR
DEPUTY
L.R.
COPY
ADMIN./
ROOM
INCIDENT
CONF.
= 137'
DISTANCE
TRAVEL
= 25'
PATH
COMMON
= 56'
PATH
COMMON
= 128'
DISTANCE
TRAVEL
= 18'
DISTANCE
DEAD END
KEY PLAN
ENCLOSURE
1 HR FIRE PARTITION/
ENCLOSURE
2 HR FIRE PARTITION/
TRAVEL DISTANCE
COMMON PATH
LEGEND
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
0
5
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
1
A
B
C
D
15 15.1 2 3 4 5 6 8 9 10 14 13 12 11 7 7.1 23 23.1 16 17 18 19 20 21 22 24 25 26 27
N
SCALE:
YARD LEVEL COMPOSITE PLAN
1" = 30'
30' 30' 0 60'
SCALE:1"=30'
YARD LEVEL - COMPOSITE PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L05
54 1"=30'
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
KEY PLAN
443
AR-L10
1
AR-L12
2
AR-L70
1
AR-L40
B
AR-L40
A
AR-L40
B
AR-L40
A
ACCESS ROAD
EMERGENCY REPAIR PIT
AR-L53
1
SEE STRUCTURAL
EDGE OF DECK ABOVE -
SEE STRUCTURAL
VEHICLE RAMP ABOVE -
AR-L40
D
AR-L40
D
A
B
C
D
1 15 15.1 2 3 4 5 6 8 9 10 14 13 12 11 7 7.1 23 23.1 16 17 18 19 20 21 22 24 25 26 27
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
0
6
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SCALE:
DECK LEVEL COMPOSITE PLAN
1 " = 30'
N
30' 30' 0 60'
SCALE:1"=30'
DECK LEVEL - COMPOSITE PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L06
55 1"=30'
LYTTONSVILLE YARD FACILITY
AR-L12
1
AR-L70
3
AR-L40
B
AR-L40
A
AR-L40
B
AR-L40
A
AR-L40
C
TRAIN WASH BUILDING
304 PARKING SPACES
BROOKVILLE ROAD
L
Y
T
T
O
N
S
V
I
L
L
E

P
L
A
C
E
TO YARD
STAIR DOWN
UP TO DECK
VEHICLE RAMP
TO DECK
STAIR UP
BROOKVILLE RD
STAIR DOWN TO
EXPANSION JOINT
EXPANSION JOINT
EXPANSION JOINT
PLAZA
LANDSCAPED
UP
TO BRIDGE
STAIR/RAMP UP
AR-L40
D
AR-L40
D
RESTRICTION BAR
VEHICLE HEIGHT
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
KEY PLAN
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
0
7
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
24 25 26 27
AA
A
A.3
B
C
A.4
A.8
B.5
B.6
B.8
C.8
AA
A
A.3
B
C
A.4
A.8
B.5
B.6
B.8
C.8
24 25 26 27
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
235 1233
ROOM/KITCHENETTE
OPERATOR BREAK
228 86
234 328
TOILET ROOM
MENS
233 328
TOILET ROOM
WOMENS
232 230
LOCKERS
236 119
CLOSET
JANITOR
237 150
MAINTENANCE
BUILDING
217 269
TEAM ROOM
218 209
YARD MASTER
219 222
INCIDENT ROOM
CORRIDOR
E-3 70
ELEVATOR E-3
S2 398
STAIR S2-3
216 73
CORRIDOR
201 314
LOBBY
200 66
VESTIBULE
229 171
215 192
CORRIDOR
221 99
222 122
205 250
ADMIN./COPY
S3 265
STAIR S3-1
231 655
CORRIDOR
227 133
TOILET ROOM
UNISEX
QUIET ROOM
206 214
207 147
208 128
204 288
230 51
203 397
CORRIDOR
223 191
TECHNICIANS
224 726
CONTROL CENTER
OPERATIONS
202 75
I.T.
220 124
SUPERVISOR
TOILET ROOM
UNISEX
OFFICE
225 436
CORRIDOR
226 562
EQUIPMENT
TRANS. SUPER.
COORDINATOR
WORK BLOCK
TRANS. SUPER.
ASST.
VESTIBULE
28 214A
LOST/FOUND
210 117
TOILET ROOM
UNISEX
CORRIDOR
212 227
MECHANICAL
209 185
TEAM ROOM
211 210
ELECTRICAL
213 291
EQUIPMENT
214 317
DISPATCH
AR-L42
B
AR-L42
B
AR-L32
A
AR-L31
A
AR-L31
B
AR-L32
B
AR-L42
A
AR-L42
A
238 30
ELEV. MACH. CL
S2 398
STAIR S2-4
304 286
ADMIN./COPY
301 157
CORRIDOR
300 317
ELEVATOR LOBBY
E-3 70
ELEVATOR E-3
309 244
CONFERENCE
305 216
303 131
302 112
CORRIDOR
306 237
308 92
311 217
ELECTRICAL
312 130
310 751
307 216
I.T.
CORRIDOR
313 471
MECHANICAL
DEPUTY DIR.
LIGHT RAIL
TOILET ROOM
UNISEX
DIRECTOR
LIGHT RAIL
INCIDENT ROOM
316 57
314 151
315 86
TOILET ROOM
UNISEX
TOILET ROOM
UNISEX
CORRIDOR
319 119
320 544
CLASSROOM
STORAGE
318 100
JANITOR CLOSET
317 106
321 302
CORRIDOR
OFFICE
TRAINING
S3 250
STAIR S3-2
COMM. ROOM
B AR-L42
AR-L42
B
AR-L32
A
AR-L31
A
AR-L32
B AR-L31
B
AR-L42
A
AR-L42
A
N
SCALE:
OFFICE FIRST FLOOR COMPOSITE PLAN
" = 1'-0"
SCALE:
OFFICE SECOND FLOOR COMPOSITE PLAN
" = 1'-0"
16' 16' 0 32'
SCALE:"=1'-0"
OFFICE - 1ST AND 2ND FLR COMPOSITE PLANS
DECEMBER 2013
RJH
RJH
DAK

AR-L07
56 1/16"=1'-0"
LYTTONSVILLE YARD FACILITY
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
0
8
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
AA
C.8
C
B.8
B.6
B.5
B
A.8
A.4
A.3
A
24 25 26 27
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
METAL ROOF
METAL ROOF
METAL ROOF
ROOF
VEGETATED
AR-L32
B
B
AR-L42
AR-L31
B
AR-L42
B
AR-L31
A
AR-L32
A
ROOF
VEGETATED
ROOFING
MEMBRANE
PVC
A
AR-L42
A
AR-L42
N
16' 16' 0 32'
SCALE: 1/16"=1'-0"
SCALE:
OFFICE ROOF COMPOSITE PLAN
" = 1'-0"
OFFICE - ROOF COMPOSITE PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L08
57 1/16"=1'-0"
LYTTONSVILLE YARD FACILITY
A
A
15.1 20 19 18 17 16 15 14 13 12
27 23.1 26 25 24 23 22 21 20
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
1
0
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
N
SCALE:
REF: AR-L05
1
AR-L10
YARD LEVEL FLOOR PLAN
"=1'-0"
8' 8' 0 16'
SCALE:"=1'-0"
YARD LEVEL - FLOOR PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L10
58 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
M
A
T
C
H

L
I
N
E
AR-L50
1
ACCESS ROAD
REPAIR PIT
EMERGENCY
24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0"
195 121
ROOM
COMPRESSOR
205 101
BREAK ROOM
LIGHT RAIL
159 102
RAIL OFFICE
LIGHT
320 103
STORAGE
MAINTENANCE
LIGHT RAIL
558 104
SUPPLY STORAGE
CLEANING
56 105
ROOM
ELECTRICAL
106
STORAGE
BULK FLUID
138 107
PROTECTION
FIRE
317
PROTECTION
FIRE
SEE EQUIP. DWGS
COMPRESSOR -
SEE EQUIP. DWGS
SANDING CARTS -
121
101
102
103
104.1
104.2
105
106
107
AR-L30
A
M
A
T
C
H

L
I
N
E
AR-L50
2
AR-L71
1
ACCESS ROAD
24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0"
UP
144 108
PROTECTION
FIRE
525 112
BREAK ROOM
CLEANING
176 113
CLEANING OFFICE
131 114
SERVICE
WATER
115
SERVICE
ELECTRICAL
112 116
SERVICE
ELECTRICAL
EMERGENCY
362
108 112
113
114 115 116
AR-L30
A
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
A
A
15 15.1 14 13 12 16 17 18 19 20
23 23.1 20 15 15 15 15 15 15
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
1
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
N
SCALE:
REF:
1
AR-L11
YARD LEVEL ROOF PLAN
"=1'-0"

8' 8' 0 16'
SCALE:"=1'-0"
YARD LEVEL - ROOF PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L11
59 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
M
A
T
C
H

L
I
N
E
24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0"
SEE MECHANICAL DWGS
CONDENSING UNIT, TYP. -
M
A
T
C
H

L
I
N
E
UP
DN
24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0"
AR-L71
2
SEE MECHANICAL DWGS
CONDENSING UNIT, TYP. -
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
1
2
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
13.1
F
F.1
12.2 11.1 10.1 8.9 7.7 13.3 14.2 15.1 13 14 15
E
F
F.1
13.1 12.2 11.1 10.1 8.9 7.7 13.3 14.2 15.1 13 14 15
N
SCALE:
REF: AR-L06
WASH BUILDING ROOF PLAN
"=1'-0"
1
AR-L12
SCALE:
REF: AR-L05
"=1'-0"
2
AR-L12
WASH BUILDING FLOOR PLAN
8' 8' 0 16'
SCALE:"=1'-0"
WASH BUILDING - FLOOR AND ROOF PLANS
DECEMBER 2013
RJH
RJH
DAK

AR-L12
60 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
KEY PLAN
AR-L73
1
117
50 118
3576
WASH BAY
ELECTRICAL
68 119
COMM. CLOSET
2
5
'
-
0
"
2
3
'
-
8

"
135'-0"
4
'
-
0
"
SEE EQUIP. DWGS, TYP.
TRAIN WASH EQUIP. -
23'-3" 80'-0"
ACCESS ROAD
2
2
'
-
2

"
4
'
-
0
"
117.5 117.6
117.1 117.2
117.3
118 119
31'-9" 25'-8" 25'-8" 25'-8" 19'-5"
3'-9" 4'-4"
15'-10"
6'-7"
15'-4"
4'-0"
AR-L41
A
AR-L41
A
AR-L41
AR-L41
AR-L41
AR-L41
B
C
D
E
117.4
4'-4" 6'-7"
AR-L73
2
2
2
'
-
2

"
4
'
-
0
"
19'-5" 25'-8" 25'-8" 25'-8" 31'-9"
3'-9" 4'-4"
15'-10" 6'-7" 15'-4" 4'-0"
AR-L41
A
AR-L41
A
AR-L41
E
AR-L41
D
AR-L41
C
AR-L41
B
10.1 11.1 12.2 13.1 14.2 15.1 13.3
AA
A
B
A.3
A.4
A.8
24 25 26 27
C
B.6
B.8
C.8
B.5
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
1
3
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
KEY PLAN
MATCH LINE
AR-L42
B
AR-L42
B
AR-L50
4
AR-L31
A
AR-L50
3
AR-L31
B
AR-L32
B
AR-L71
3
AR-L42
A
ROOF
VEGETATED
200.1 200.2
201
202
203
204
206
207
208
211
212
213
214
215
218 219
220 222
223
224.1
224.2
226.1 226.2
24'-0" 24'-0" 24'-0"
72'-0"
1
6
'
-
1
0

"
1
3
'
-
9

"
3
1
'
-
1
1

"
8
'
-
0

"
2
1
'
-
3
"
1
6
3
'
-
4
"
2
'
-
9
"
UP
DN
DN
200
217
202
216
218 219
206 205
207
208
220
215
222
223
204
209
211
212
213
214
203
226
224
225
201
ROOF
VEGETATED
MATCH LINE
AR-L32
A
AR-L50
5
AR-L72
1
AR-L51
3
AR-L51
1
AR-L51
2
AR-L42
A
PLAZA
LANDSCAPED
203
213
214
214A
224.2
226.1 226.2
228
229
230.1
230.2
235
236
237
UP
W/ GATE
SECURITY FENCE
3
1
'
-
1
1

"
8
'
-
0

"
2
1
'
-
3
"
4
0
'
-
7
"
8
'
-
9
"
1
7
'
-
4
"
1
6
3
'
-
4
"
2
'
-
0
"
UP
UP
214A
213
214
203
226
230
231
229
228
237
236
235
PLAZA
LANDSCAPED
UP
W/ GATE
SECURITY FENCE
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
N
8' 8' 0 16'
SCALE: 1/8"=1'-0"
SCALE:
OFFICE FIRST FLOOR PLAN
"=1'-0"
OFFICE - FIRST FLOOR PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L13
61 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
AA
A
B
A.3
A.4
A.8
24 25 26 27
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
1
4
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
C
B.6
B.8
C.8
B.5
N
SCALE:
OFFICE SECOND FLOOR PLAN
"=1'-0"
8' 8' 0 16'
SCALE:"=1'-0"
OFFICE - SECOND FLOOR PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L14
62 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
MATCH LINE
AR-L42
B
AR-L31
B
AR-L32
B
AR-L42
B
AR-L31
A
AR-L71
4
AR-L51
4
AR-L51
5
AR-L42
A
ROOF
VEGETATED
300
301
305
306
307
308
309
311
312
313
3:12
SLOPE
24'-0" 24'-0" 24'-0"
72'-0"
1
6
'
-
1
0

"
1
3
'
-
9

"
3
1
'
-
1
1

"
8
'
-
0

"
2
1
'
-
3
"
1
6
3
'
-
4
"
2
'
-
9
"
UP
DN
309
300
301
304
308
311
312
310
313
302
305
306
307
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
KEY PLAN
443
MATCH LINE
AR-L32
A
AR-L31 AR-L32
AR-L51
5
AR-L71
2
AR-L42
A
ROOF
VEGETATED
318
319
320
321.1 321.2
3:12
SLOPE
3:12
SLOPE
3
1
'
-
1
1

"
8
'
-
0

"
2
1
'
-
3
"
4
0
'
-
7
"
8
'
-
9
"
1
7
'
-
4
"
1
6
3
'
-
4
"
2
'
-
0
"
DN
319 318
317
321
320
C
B.6
B.8
C.8
B.5
AA
A
B
A.3
A.4
A.8
24 25 26 27
AA
A
24 25
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
A
r
c
h
i t
e
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
V
P

P
l a
n
s
\
1
0
4
2
p
A
R
L
A
1
5
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
KEY PLAN
AR-L32
A
AR-L31
B
AR-L32
B
AR-L42
A
METAL ROOF
METAL ROOF
METAL ROOF
ROOF
VEGETATED
METAL ROOF
1
7
'
-
4
"
8
'
-
9
"
4
0
'
-
7
"
4
0
'
-
0
"
8
'
-
0

"
2
'
-
0
"
1
6
3
'
-
4
"
ROOFING
PVC MEMBRANE
12:12
SLOPE
10:12
SLOPE
3:12
SLOPE
3:12
SLOPE
MATCH LINE
AR-L31
B
AR-L42
B
AR-L32
B
AR-L42
B
AR-L31
A
AR-L42
A
24'-0" 24'-0" 24'-0"
72'-0"
4
0
'
-
0
"
8
'
-
0

"
2
1
'
-
3
"
2
'
-
9
"
1
3
'
-
9

"
1
6
'
-
1
0

"
1
6
3
'
-
4
"
11:12
SLOPE
6:12
SLOPE
3:12
SLOPE
DN
DN
S2.5
477 S2
STAIR S2-5
METAL ROOF
24'-0" 24'-0" 24'-0"
72'-0"
1
3
'
-
9

"
1
6
'
-
1
0

"
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
N
SCALE:
OFFICE ROOF PLAN
"=1'-0"
SCALE: "=1'-0"
OFFICE ROOF STAIR PLAN
AR-L71
5
8' 8' 0 16'
SCALE:"=1'-0"
OFFICE - ROOF PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L15
63 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
A
A
12 15 15.1 13 14 16 17 18 19 20
23.1 20 21 22 23 24 25 26 27
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
2
0
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
N
SCALE:
YARD LEVEL REFLECTED CEILING PLAN
"=1'-0"
8' 8' 0 16'
SCALE:"=1'-0"
YARD LEVEL - REFLECTED CEILING PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L20
64 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
M
A
T
C
H

L
I
N
E
24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0"
101 102
105
100
103 104 106 121 107
M
A
T
C
H

L
I
N
E
24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
22'-0" 24'-0" 24'-0"
108
109 110
111 112
113
S2
E-3
115 116
114
122
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
LEGEND
SEE ELECTRICAL
LIGHT FIXTURES
GRILLE
DIFFUSER/
MECHANICAL
APC
GYPSUM BOARD
OPEN TO STRUCTURE
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
2
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
N
SCALE:
WASH BUILDING REFLECTED CEILING PLAN
" = 1'-0"
8' 8' 0 16'
SCALE:"=1'-0"
WASH BUILDING - REFLECTED CEILING PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L21
65 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
KEY PLAN
117
118 119
LEGEND
SEE ELECTRICAL
LIGHT FIXTURES
GRILLE
DIFFUSER/
MECHANICAL
APC
GYPSUM BOARD
OPEN TO STRUCTURE
24 25 26 27
AA
A
B
A.3
A.4
A.8
C
B.6
B.8
C.8
B.5
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
2
2
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
KEY PLAN
MATCH LINE
S2
217
216
201
225
212
211
215
202
226
224
223
221
222
220
219
218
213
214
203
210
209
204
207
208
206
205
200
E-3
MATCH LINE
238
MATCH LINE
S3
228
235
232
231
225
227
229
226
237
236
234
233
230
214A
213
214
203
MATCH LINE
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
LEGEND
SEE ELECTRICAL
LIGHT FIXTURES
APC
GYPSUM BOARD
DIFFUSER/GRILLE
MECHANICAL
STRUCTURE
OPEN TO
N
8' 8' 0 16'
SCALE: 1/8"=1'-0"
OFFICE - 1ST FLOOR REFLECTED CEILING PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L22
66 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
AA
A
B
A.3
A.4
A.8
24 25 26 27
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
2
3
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
C
B.6
B.8
B.5
N
8' 8' 0 16'
SCALE:"=1'-0"
OFFICE 2ND FLOOR REFLECTED CEILING PLAN
DECEMBER 2013
RJH
RJH
DAK

AR-L23
67 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
MATCH LINE
S2
E-3
300
309
308
301
313
310
307
312
311
303
304
305
302
306
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
KEY PLAN
443
LEGEND
SEE ELECTRICAL
LIGHT FIXTURES
APC
GYPSUM BOARD
DIFFUSER/GRILLE
MECHANICAL
STRUCTURE
OPEN TO
MATCH LINE
313
316
315
318
317
S3
314
319
320
321
27 23.1 26 25 24 23 22 21 20
20 19 18 17 16 15 14 13 12 15.1
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
3
0
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
AR-L10
A
AR-L30 " = 1'-0" SCALE:
REF:
YARD LEVEL ELEVATION
8' 8' 0 16'
SCALE:"=1'-0"
YARD LEVEL - ELEVATIONS
DECEMBER 2013
RJH
RJH
DAK

AR-L30
68 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
M
A
T
C
H

L
I
N
E
YARD LEVEL
1
2
'
-
0
"
22'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 22'-0"
4'-0"
24'-0" 24'-0" 24'-0" 22'-0"
M
A
T
C
H

L
I
N
E
1
2
'
-
0
"
22'-0" 24'-0" 24'-0"
4'-0"
22'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 22'-0"
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
AA A B C A.3 A.4 A.8 B.6 B.8 C.8 B.5
NORTH
27 26 25 24
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
3
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
A
AR-L31 " = 1'-0"
B
AR-L31 " = 1'-0"
SCALE:
REF:
NORTH ELEVATION
SCALE:
REF:
EAST ELEVATION
AR-L07, AR-L08, AR-L13, AR-L14, AR-L15
AR-L07, AR-L08, AR-L13, AR-L14, AR-L15
8' 8' 0 16'
SCALE:"=1'-0"
OFFICE - BUILDING ELEVATIONS
DECEMBER 2013
RJH
RJH
DAK

AR-L31
69 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
305'-0"
PARKING DECK
305'-6"
WALKWAY
305'-8 1/2"
1ST FLR
319'-8 1/2"
2ND FLR
333'-8 1/2"
ROOF
335'-2 1/2"
T.O. PARAPET
10
12 12
12
AR-L42
B
AR-L42
B
METAL ROOF
STANDING SEAM
METAL WALL PANEL
STANDING SEAM
WALL PANEL
RIBBED METAL
SEE STRUCTURAL
CONCRETE SILL WALL -
W5 W8 W4 W5
W5 W5
W5 W4 W3 W3 W3 W3 W5
W1
W2 W2 W2 W2 W2 W2 W2 W2 W2 W2
SF1A
AR-L74
1
W6 W7
W5
305'-0"
PARKING DECK
305'-6"
WALKWAY
305'-8 1/2"
1ST FLR
319'-8 1/2"
2ND FLR
333'-8 1/2"
ROOF
335'-2 1/2"
T.O. PARAPET
6
12 12
11
WALL PANEL
RIBBED METAL
METAL ROOF
STANDING SEAM
UTILITY
FACE BRICK -
AR-L42
A
AR-L42
A
WALL - SEE STRUCTURAL
CONCRETE SILL
SF1B
W6 W4
SF2A
PANELS, TYP.
SAFETY
MESH INFILL
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
C.8 C B.8 B.6 B.5 B A.8 A.3 A.4 A AA
SOUTH
24 25 26 27
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
3
2
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
B
AR-L32 " = 1'-0"
A
AR-L32 " = 1'-0"
SCALE:
REF:
WEST ELEVATION
SCALE:
REF:
SOUTH ELEVATION
AR-L07, AR-L08, AR-L13, AR-L14, AR-L15
AR-L07, AR-L08, AR-L13, AR-L14, AR-L15
8' 8' 0 16'
SCALE:"=1'-0"
OFFICE - BUILDING ELEVATIONS
DECEMBER 2013
RJH
RJH
DAK

AR-L32
70 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
305'-0"
PARKING DECK
305'-6"
WALKWAY
305'-8 1/2"
1ST FLR
319'-8 1/2"
2ND FLR
333'-8 1/2"
ROOF
335'-2 1/2"
T.O. PARAPET
10
12 12
12
AR-L42
B
AR-L42
B
WALL PANEL
RIBBED METAL
METAL WALL PANEL
STANDING SEAM
METAL ROOF
STANDING SEAM
LOUVERS
METAL
UTILITY
BRICK -
FACE
SEE STRUCTURAL
CONCRETE SILL WALL -
SF2B
W2 W2 W2 W2 W2 W2 W2
SF5
SF4
W4 W5 W3 W8
W9 W10 W9 W9 W11 W9 W12 W10
AR-L74
1
305'-0"
PARKING DECK
305'-6"
WALKWAY
305'-8 1/2"
1ST FLR
319'-8 1/2"
2ND FLR
333'-8 1/2"
ROOF
335'-2 1/2"
T.O. PARAPET
11
12 12
6
WALL PANEL
RIBBED METAL
METAL ROOF
STANDING SEAM
METAL WALL PANEL
STANDING SEAM
AR-L42
A
AR-L41
A
SEE STRUCTURAL
CONCRETE SILL WALL -
SF3
W2 W2 W2 W2 W2
W4 W3 W5
SF6
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
4
0
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
A B C D
A B C D
27 26 25 24 23 23.1 15.1 22 21 20 19 18 17 16 15
NORTH
15.1 7.1 15 14 13 12 11 10 9 8 7 5 4 3 2 1 6
A B
AR-L40
B
" = 1'-0" AR-L40
A
" = 1'-0" SCALE:
REF:
OVERALL SECTION THROUGH PLAZA
AR-L05, AR-L06
SCALE:
REF:
OVERALL SECTION THROUGH PARKING DECK & YARD
AR-L05, AR-L06
16' 16' 0 32'
SCALE:"=1'-0"
AR-L40
C
" = 1'-0"
AR-L06
SCALE:
REF:
OVERALL SECTION THROUGH BROOKVILLE ROAD
AR-L40
D
" = 1'-0"
AR-L05, AR-L06
SCALE:
REF:
SECTION THROUGH VEHICLE RAMP
OVERALL SECTIONS
DECEMBER 2013
RJH
RJH
DAK

AR-L40
71 1/16"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
BRIDGE BEYOND
LYTTONSVILLE PL
YARD
LRV STORAGE
PIT BEHIND
EMERGENCY REPAIR
305'-0"
DECK
305'-6"
WALKWAY
T.O. PLAZA
BRIDGE PARAPET
B.O. CONCRETE
STRUCTURE
BRIDGE
RAMP LANDING
T.O. EGRESS
BRIDGE DWGS
SEE LYTTONSVILLE
SAFETY BARRIER -
ROAD
BROOKVILLE
M
A
T
C
H

L
I
N
E
TYP.
8'-0"
RESTRICTION BAR
VEHICLE HEIGHT
ENTRANCE RAMP
VEHICLE
BEYOND
YARD LEVEL
M
A
T
C
H

L
I
N
E
STEEL RAILING, TYP.
TYP.
8'-0" PANELS, TYP.
MESH INFILL SAFETY
BEYOND
YARD LEVEL
YARD
LRV STORAGE UP TO DECK
VEHICLE RAMP
ROAD
BROOKVILLE
305'-0"
DECK
E F F.1
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
4
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
13.1 12.2 11.1 10.1 8.9 7.7 E F F.1
7.7 8.9 10.1 11.1 12.2 13.1 E F F.1
A
AR-L41 " = 1'-0"
AR-L12
8' 8' 0 16'
SCALE:"=1'-0"
B
AR-L41 " = 1'-0"
AR-L12
SCALE:
REF:
BUILDING SECTION
SCALE:
REF:
NORTH ELEVATION C
AR-L41 " = 1'-0"
AR-L12
SCALE:
REF:
EAST ELEVATION
D
AR-L41 " = 1'-0"
AR-L12
SCALE:
REF:
SOUTH ELEVATION E
AR-L41 " = 1'-0"
AR-L12
SCALE:
REF:
WEST ELEVATION
WASH BUILDING - ELEVATIONS AND SECTIONS
DECEMBER 2013
RJH
RJH
DAK

AR-L41
72 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
117
118
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
YARD LEVEL
AR-L41
A
AR-L41
A
ROOF
2
5
'
-
3
"
UTILITY, TYP.
FACE BRICK -
WALL PANEL, TYP.
RIBBED METAL
NORTH
YARD LEVEL
ROOF
2
5
'
-
3
"
UTILITY, TYP.
FACE BRICK -
WALL PANEL, TYP.
RIBBED METAL
YARD LEVEL
AR-L41
A
AR-L41
A
ROOF
2
5
'
-
3
"
UTILITY, TYP.
FACE BRICK -
WALL PANEL, TYP.
RIBBED METAL
SOUTH
YARD LEVEL
ROOF
2
5
'
-
3
"
UTILITY, TYP.
FACE BRICK -
WALL PANEL, TYP.
RIBBED METAL
24 25 26 27
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
4
2
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
AA A A.3 A.4 A.8 B B.5 B.6 B.8 C C.8
B
AR-L42 " = 1'-0" SCALE:
REF:
BUILDING SECTION
AR-L07, AR-L08, AR-L13, AR-L14, AR-L15, AR-L31, AR-L32
A
AR-L42 " = 1'-0" SCALE:
REF:
BUILDING SECTION
AR-L07, AR-L08, AR-L13, AR-L14, AR-L15, AR-L31, AR-L32
8' 8' 0 16'
SCALE:"=1'-0"
OFFICE - BUILDING SECTIONS
DECEMBER 2013
RJH
RJH
DAK

AR-L42
73 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
305'-0"
PARKING DECK
305'-6"
WALKWAY
305'-8 1/2"
1ST FLR
319'-8 1/2"
2ND FLR
333'-8 1/2"
ROOF
335'-2 1/2"
T.O. PARAPET
306
204 209
210
307 312
203
225
224
310
AR-L43
1
ATC
ATC ATC
ATC
STEEL JOIST
OPEN WEB
STRUCTURAL
STEEL BEAM - SEE
BRIDGE DWGS
BRIDGE - SEE
LYTTONSVILLE PL
PLAZA
LANDSCAPED
ACCESS TO ROOF
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
305'-0"
PARKING DECK
305'-6"
WALKWAY
305'-8 1/2"
1ST FLR
319'-8 1/2"
2ND FLR
333'-8 1/2"
ROOF
335'-2 1/2"
T.O. PARAPET
217 216 215 220 224 226 229 235
309 310
ATC ATC
STRUCTURAL
STEEL BEAM - SEE
STEEL JOIST
OPEN WEB
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
4
3
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
24
SCALE:
REF: AR-L41
"=1'-0"
1
AR-L43
WALL SECTION
2' 2' 0 4'
SCALE:"=1'-0"
SCALE:
REF:
1"=1'-0"
2
AR-L43
TYP. VEGETATED ROOF
AR-L15, AR-L41
1' 1' 0 2'
SCALE: 1"=1'-0"
OFFICE WALL SECTIONS
DECEMBER 2013
RJH
RJH
DAK

AR-L43
74 3/4"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
L.R. DIRECTOR
TEAM ROOM AND
WEST WALL @
305'-8 1/2"
1ST FLOOR
305'-6"
WALKWAY
305'-0"
PARKING DECK
319'-8 1/2"
2ND FLOOR
INSULATION
RIGID
WALL PANEL
RIBBED METAL
METAL WALL PANEL
STANDING SEAM
STEEL JOIST
OPEN WEB
CONCRETE SLAB
SEE STRUCTURAL
BEYOND -
STEEL COLUMN
INSULATION
RIGID
2 LAYERS 1"
CEILING
TILE
ACOUSTICAL
BOARD
1/2" COVER
SEE STRUCTURAL
CONCRETE SILL WALL -
ARCH FINISH ON
VERTICALLY
Z CLIPS ORIENTED
INSULATION
RIGID EXTERIOR
VAPOR BARRIER
EXTERIOR SHEATHING
BOARD
5/8" GYPSUM
METAL STUD
6" COLD FORMED
INTERIOR RIGID INSULATION
OVERLAPING EXTERIOR/
SPRAY FOAM INSULATION
333'-8 1/2"
ROOF
335'-2 1/2"
T.O. PARAPET
METAL WALL PANEL
STANDING SEAM
CONCRETE SLAB
CEILING
ACOUSTICAL TILE
METAL WALL PANEL
STANDING SEAM
INFILL PANEL
METAL
SEE STRUCTURAL
STEEL BEAM -
SEE STRUCTURAL
BEYOND -
STEEL COLUMN
VERTICALLY
Z CLIPS ORIENTED
1'-0"
T.O. PARAPET
T.O. ROOF
BALAST STONE
WATER RETENTION ELEMENT
FILTER FABRIC
PLANTING MEDIA
ROOF VEGETATION
DETAIL 1/AR-L43
STRUCTURE SEE
TYP. ROOF
BARRIER
COURSE/ ROOT
PROTECTION
SIZE AS INDICATED
RIGID ROOF INSULATION
LINE OF PARAPET BEYOND
1
"
6
"
4
"
WATERPROOFING
APPLIED MEMBRANE
HOT FLUID -
WATERPROOFING
APPLIED MEMBRANE
HOT FLUID -
1/AR-L43
SEE DETAIL
WALL STRUCTURE
TYP. PARAPET AND
PERFORATED DRAIN BAR
WATERPROOFING
A A
13 21 22
26 25
B
A.8
B.6
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
5
0
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
GENERAL NOTES
SCALE:
REF: AR-L10
" = 1'-0"
1
AR-L50
TOILET ROOM 100
SCALE:
REF: AR-L10
" = 1'-0"
2
AR-L50
TOILET ROOMS 109 & 110
SCALE:
REF: AR-L13
" = 1'-0"
3
AR-L50
TOILET ROOM 221
SCALE:
REF: AR-L13
" = 1'-0"
4
AR-L50
TOILET ROOM 210
SCALE:
REF: AR-L13
" = 1'-0"
5
AR-L50
TOILET ROOM 227
SCALE:
REF:
" = 1'-0"
6
AR-L50
AR-L50, AR-L51
TYP. TOILET STALLS
SCALE:
REF:
" = 1'-0"
7
AR-L50
AR-L50, AR-L51
TYP. ADA SHOWER STALL
FOR VANITY TYPICAL DETAILS SEE SHEET AR-L52 2.
FOR TOILET COMPARTMENTS MOUNTING HEIGHT SEE SHEET AR-L51 1.
4' 4' 0 8'
SCALE:"=1'-0"
2' 2' 0 4'
SCALE:"=1'-0"
ENLARGED TOILET ROOM PLANS
DECEMBER 2013
RJH
RJH
DAK

AR-L50
75 AS SHOWN
LYTTONSVILLE YARD FACILITY
1
'
-
2

"
2'-2" 9'-10"
6'-4"
1
3
'
-
1
1

"
100
UNISEX TOILET RM
GB1
SND
TD
GB2
FS
PTD
SD
M
RH
100
1
4
'
-
1
1

"
5
'
-
0
"
3
'
-
1
1

"
5
'
-
0
"
1
4
'
-
1
1

"
10'-8"
1'-10"
8'-11"
5'-1"
1'-9"
7
"
5
'
-
1
0
"
4
'
-
6
"
1'-0"
1
'
-
4

"
2'-2"
1
'
-
3
" 5
'
-
6
"
110
UNISEX TOILET ROOM
UNISEX TOILET RM
109
PTD
M
SD
GB1
SND
GB2
TD
FS
FS
GB1
GB2
TD
SND
SD
M
RH
111
CORRIDOR
109
110
5
'
-
5
"
2
'
-
1
0
"
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
1
0
'
-
1

"
1
'
-
7

"
8'-8"
2
'
-
6
"
2'-5"
1'-2"
UNISEX TOILET ROOM
221
SND
TD
GB2
FS
GB1
SD
M
PTD
221
11'-3" 1'-7"
1'-0"
7'-6"
1'-3"
1'-2"
2
'
-
5
"
UNISEX TOILET ROOM
210
SND
TD
GB2
GB1
FS
PTD
RH
SD
M
210
8
'
-
1
0

"
1
'
-
7

"
5'-0"
1'-4"
4
'
-
0
"
UNISEX TOILET ROOM
227
FS
TD
SND
GB2
GB1
PTD
M
SD
RH
227
6
"
1
'
-
6
"
1'-0"
5'-0"MIN.
5
'
-
0
"
M
I
N
.
5'-0"
E
Q
E
Q
2
'
-
6
"
M
I
N
.
ONLY)
AND WOMEN
SND (UNISEX
WOMEN ONLY)
(UNISEX AND
SHELF (FS)
FOLD DOWN
WOMEN ONLY)
FS (UNISEX AND
POSITION
RESTING
IN 15
HOLDS DOOR
HINGE -
ADJUSTABLE
BALANCED
DOOR WITH
RH
WOMEN ONLY)
(UNISEX AND
DISPOSAL SND
NAPKIN
SANITARY
POSITION
RESTING
IN 15
HOLDS DOOR
HINGE -
ADJUSTABLE
BALANCED
DOOR WITH
(RH)
ROBE HOOK
4
"
2
'
-
8
"
M
I
N
.
M
A
X
GB1
GB2
3'-0" 1'-4"
GRAB BAR
GB 1
GRAB BAR
GB 2
DISPOSAL
NAPKIN
SANITARY
SND
3'-0" 1'-4"
DISPENSER (TD)
TOILET TISSUE
TD
9"
9" 1
'
-
6
"
1
'
-
1
1
"
GRAB BAR
SHOWER HEAD
CHAIR
FOLDING
1'-3"
1
'
-
4

"
FD
UNIT
TOWEL/TRASH
SEMI RECESSED
PTD
DISPOSAL
NAPKIN
SANITARY
SND
3'-0" CLR
3
'
-
0
"

C
L
R
B
B
B
B
B
B
B
A
C
C
25
25
25
24
24
B.8
C.8
A.3
A.4
B.5
B.6
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
5
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
GENERAL NOTES
SCALE:
TYP. TOILET COMPARTMENT'S MOUNTING HEIGHT
N.T.S.
SCALE:
REF: AR-L13
" = 1'-0" AR-L51
1 TOILET ROOM 233
SCALE:
REF: AR-L13
" = 1'-0" AR-L51
2 TOILET ROOM 234
SCALE:
REF: AR-L13
" = 1'-0" AR-L51
3
SCALE:
REF: AR-L14
" = 1'-0" AR-L51
4 TOILET ROOM 303
SCALE:
REF: AR-L14
" = 1'-0" AR-L51
5 TOILET ROOM 314 & 315
FOR TYPICAL VANITY DETAILS SEE SHEET AR-L52 3.
FOR ADA SHOWER STALL MODULAR SEE SHEET AR-L50 2.
FOR TOILET STALL DETAILS SEE SHEET AR-L50 1.
LOCKERS 232
4' 4' 0 8'
SCALE:"=1'-0"
ENLARGED TOILET ROOM PLANS
DECEMBER 2013
RJH
RJH
DAK

AR-L51
76 3/8"=1'-0"
LYTTONSVILLE YARD FACILITY
FS
TD
SND
GB2
GB1
FS
TD
SND
FS
TD
SND
PTD M
SD
M
SND
TD
FS
5
'
-
0
"
1
2
'
-
8
"
2
'
-
1
0
"
2
'
-
6

"
2
'
-
6

"
1
'
-
3
"
6
'
-
1
"
1'-0"
10'-6"
3'-9"
5'-2"
7

"
4
'
-
5

"
2'-11"
7
'
-
9

"
2
5
'
-
9

"
2'-11" 3'-9"
10"
8
'
-
3

1
/
2
"
WOMEN'S TOILET ROOM
233
LOCKERS
233
1
2
"

M
I
N
M
SD
M
PTD
USCR
TD
TD
RH
UR2
UR1
15 16
11"
1'-2"
1
'
-
0
"
10'-6"
4
'
-
5

"
6
'
-
7
"
4
'
-
7
"
8
'
-
0

"
5
'
-
0
"
2
'
-
7
"
2
'
-
3

"
1
'
-
0
"
2
'
-
1
0
"
5'-2"
3'-9"
1'-0"
2'-11"
2
5
'
-
2
"
2'-11" 3'-9"
10"
8
'
-
3

1
/
2
"
8
'
-
3

1
/
2
"
234
MEN'S TOILET ROOM
232
LOCKERS
234
1
2
"

M
I
N
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
1
'
-
8
"
8
'
-
1
1

"
2'-3"
4
'
-
0
"
4
'
-
0
"
4
'
-
0
"
4'-0" 5'-0"
1'-8"
8'-6" 5
'
-
7

"
314
315
UNISEX TOILET RM
UNISEX TOILET RM
FS
TD
SD
M
SND
RH
SD
M
GB2
GB1
PTD
FS
TD
SND
GB2
GB1
PTD
CORRIDOR
316
SINK
314
315
5'-2"
5
'
-
0
"
1
3
'
-
9

"
1'-8"
3'-5" 5'-5"
303
UNISEX TOILET RM
M
SD
FS
TD
GB1
GB2 SND
RH
303
1
'
-
2

"
9

"
5'-0"
GRAB BAR
GB 1
GRAB BAR
GB 2
URINAL
UR 1
ADA URINAL
UR 2
SCREEN
URINAL
USCR
SHELF
DOWN
FOLD
FS
UNIT
TOWEL/TRASH
SEMI RECESSED
PTD
CLOSET
WATER
WC
DISPENSER
SOAP
SD
HOOK
ROBE
RH
DISPENSER
TOILET TISSUE
TD
MIRROR
M
3
'
-
0
"
3'-0"
6"
3
'
-
0
"
1'-0"MAX
2
'
-
0
"
3
'
-
6
"
4
'
-
0
"
3
'
-
3
"
3
'
-
8
"
2'-0"
2'-0"
DISPOSAL
NAPKIN
SANITARY
SND
9"
2
'
-
0
"
1
'
-
6
"
M
A
X
3
'
-
0
"
3
'
-
0
"
1
'
-
7
"
1
'
-
5
"
2
'
-
4
"
TD
O
R

3
5
"

M
A
X
.
A
B
O
V
E

S
I
N
K
3'-6"
A
B
O
V
E

C
O
U
N
T
E
R
2
'
-
1
0
"
PIPE
INSULATED
SINK WITH
3'-0" CLR
5'-0"
8'-1"
6'-0"
1
'
-
9

"
1
0

"
1'-7"
7'-3"
2'-6" 3'-2"
1
2
3
4
5
6
7
8
9
10
11
13 14 15 16
12
2
'
-
1
0

"
7
'
-
9

"
8
'
-
3

"
LOCKERS
11"
1'-2"
1
9
'
-
0
"
1
'
-
0
"
WORK
CASE
1
8
'
-
0
"
1'-2"
2'-6"
232
LOCKERS
B
B
B
A
A
A
A
B
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
5
2
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
GENERAL NOTES
2' 2' 0 4'
SCALE:"=1'-0"
1' 1' 0 2'
SCALE: 1"=1'-0"
SCALE:
REF: AR-L52
" = 1'-0"
1
AR-L52
VANITY ELEVATION
SCALE:
REF: AR-L52
" = 1'-0"
2
AR-L52
VANITY PLAN
SCALE:
REF: AR-L52
1" = 1'-0"
A
AR-L52
SECTION THROUGH COUNTERTOP
SCALE:
REF: AR-L52
1" = 1'-0"
B
AR-L52
END BRACE AT SIDEWALLS
FOR TOILET TYPICAL STALL SEE SHEET AR-L50 2.
FOR TOILET COMPARTMENTS MOUNTING HEIGHT SEE SHEET AR-L51 1.
AR-L52
2
AR-L52
1
AR-L52
A
AR-L52
B
VANITY AND MISCELLANEOUS DETAILS
DECEMBER 2013
RJH
RJH
DAK

AR-L52
77 AS NOTED
LYTTONSVILLE YARD FACILITY
12" 12" 12" 12"
MIRROR
ENDWALL
DISPENSER
SOAP
FINISH
WALL
SCHEDULED
BASE
SCHEDULED
PANELS
REMOVABLE
SIDESPLASH
BACKSPLASH AND
MATERIAL TOP,
SOLID SURFACE
MIRROR
DISPENSER
SOAP
FRAMING
WOOD SIDEWALL
2x4 NO 2 GRADE
SIDESPLASH
BACKSPLASH AND
MATERIAL TOP,
SOLID SURFACE
3'-0"
SEE PLAN
2
'
-
9
"
3
'
-
1
"
6"6"
BRACES AND FRAMING
(2) 2x4 NO 2 GRADE WOOD
FROM 2x4 WOOD
EDGE FRAMING CUT M
A
X
.
2
'
-
0
"
4
"
5
" S
C
H
E
D
U
L
E
D

C
E
I
L
I
N
G
9

"
1"
4
"
5
"
FINISH AND BASE
SCHEDULED WALL
SHIM
BACKSPLASH AND SIDESPLASH
SOLID SURFACE MATERIAL TOP,
SOLID SURFACE MATERIAL
SHIM
MIRROR
SCHEDULED WALL FINISH BEHIND MIRROR
SINGLE 2x4 WOOD FRAMING AT ENDWALLS
SINKS. BOLT TOGETHER W/ 3/8" DIA BOLTS.
(2) 2x4 No 2 GRADE WOOD FRAMING BETWEEN
GLUE MEMBERS
BRACE AT ENDWALLS. DOWEL AND
CENTERED BETWEEN SINKS - SINGLE
(2) 2x4 No 2 GRADE WOOD BRACES.
1

"
3

"
2
'
-
9
"

M
A
X
.
9

"
8"CLR.
CONT 2x4 No 2 GRADE WOOD LEDGER
2
'
-
3
"

M
I
N
.

C
L
E
A
R
GROUNDS W/ 1/2" DIA MACH BOLTS
- BOLT TO STUDS THRU STEEL
CONT 2x4 No 2 GRADE WOOD LEDGER
CONT 16GA 4"STL PLATE GROUNDS
WELD TO METAL STUDS
GROUNDS AT BACK AND SIDES -
CONT 16GA 4" STEEL PLATE
PANEL ATTACHMENT
BLOCKING AT SIDEWALLS FOR
CLIPS. PROVIDE 2x WOOD
WITH STAINLESS STEEL ZEE
PANELS SECURED TO BRACING
(2x)REMOVABLE 3/4" THK PLAM
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
AT 12" O.C.
GROUNDS W/ 1/2" DIA MACH BOLTS
- BOLT TO WALL THRU STEEL
CONT 2x4 No 2 GRADE WOOD LEDGER
AT 12" O.C.
GROUNDS W/ 1/2" DIA MACH BOLTS
- BOLT TO WALL THRU STEEL
CONT 2x4 No 2 GRADE WOOD LEDGER
1
0

"
IN SIDEWALL
METAL GROUNDS
IN SIDEWALL
METAL GROUNDS
1
'
-
1
0
"
1'-5"
GROUNDS AND CONCEALED BLOCKING
BRACE SECURE TO WALL THRU METAL
2x4 No 2 GRADE WOOD ENDWALL
5"
1'-10" MAX
GROUNDS AND CONCEALED BLOCKING
SECURE TO WALL THRU METAL
2x4 No 2 GRADE WOOD BRACING
13 13 13 13 9
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
5
3
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SCALE:
REF: AR-L05
"=1'-0"
1
AR-L53
EMERGENCY REPAIR PIT ENLARGED PLAN
4' 4' 0 8'
SCALE:"=1'-0"
ENLARGED PLANS
DECEMBER 2013
RJH
RJH
DAK

AR-L53
78 AS NOTED
LYTTONSVILLE YARD FACILITY
EMERGENCY REPAIR PIT
117'-0"
1
1
'
-
0
"
1'-0" TYP.
SEE EQUIP. DWGS
ELECTRIC PUMP, TYP. -
SECTION INFORMATION
SEE STRUCTURAL FOR
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
2 3
A
1
A
1 2
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
7
0
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
1 2
A
SCALE:
REF: AR-L06
3
AR-L70 "=1'-0"
SCALE:
REF:
2
AR-L70 "=1'-0" SCALE:
REF: AR-L05
1
AR-L70 "=1'-0"

ENLARGED ELEVATOR E-1/E-2 YARD LEVEL PLAN ENLARGED STAIR S1-1 AND ELEVATOR E-1/E-2 PLAN AT BROOKVILLE RD
ENLARGED STAIR S1-2 AND ELEVATOR E-1/E-2 DECK LEVEL PLAN
4' 4' 0 8'
SCALE:"=1'-0"
ENLARGED STAIR\ELEVATOR PLANS S1 E-1 E-2
DECEMBER 2013
RJH
RJG
DAK

AR-L70
79 1/4"=1'-0"
LYTTONSVILLE YARD FACILITY
85 E-1
85 E-2
130 120
FIRE PROTECTION
VEHICLE YARD
LIGHT RAIL
120
ELEVATOR PIT
ELEVATOR PIT
UNEXCAVATED
1
0
'
-
8
"
8'-0"
12'-7"
8'-0"
5
'
-
1
1

"
11'-4"
PROTECT.
FIRE
245 S1
STAIR S1-1
85 E-1
ELEVATOR
85 E-2
ELEVATOR
135 122
ELEVATOR LOBBY
UP
ROAD SIDEWALK
BROOKVILLE 122
22'-11"
8'-0"
12'-7"
8'-0"
8
'
-
8
"
1
0
'
-
8
"
5'-6"
EQ
EQ
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
245 S1
STAIR S1-2
85 E-1
ELEVATOR
85 E-2
ELEVATOR
DN
PARKING DECK
EDGE OF SLAB
ELEV CONTROL CLOSETS
EDGE OF CANOPY ABOVE
8'-0"
12'-7"
8'-0"
1
0
'
-
8
"
24 25
A A
24 25
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
7
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
A
AA
24 25
AA
A
24 25
A
24 25
AA
SCALE:
REF: AR-L11
2
AR-L71 "=1'-0" SCALE:
REF: AR-L10
1
AR-L71 "=1'-0"
ENLARGED STAIR S2-1 AND ELEVATOR E3 PLAN ENLARGED STAIR S2-2 AND ELEVATOR E3 PLAN
SCALE:
REF: AR-L14
4
AR-L71 "=1'-0"
ENLARGED STAIR S2-4 AND ELEVATOR E3 PLAN
SCALE:
REF: AR-L15
5
AR-L71 "=1'-0"
ENLARGED STAIR S2-5
SCALE:
REF: AR-L13
3
AR-L71 "=1'-0"
ENLARGED STAIR S2-3 AND ELEVATOR E3 PLAN
YARD LEVEL YARD LEVEL ROOF
OFFICE FIRST FLOOR OFFICE SECOND FLOOR
OFFICE ROOF
4' 4' 0 8'
SCALE:"=1'-0"
ENLARGED STAIR\ELEVATOR PLANS S2 E-3
DECEMBER 2013
RJH
RJH
DAK

AR-L71
80 1/4"=1'-0"
LYTTONSVILLE YARD FACILITY
AR-L74
1
AR-L74
1
380
STAIR S2-1
67
ELEVATOR
S2
E-3
S2.1
UP
55 122
ELEVATOR LOBBY
122
380
STAIR S2-2
67
ELEVATOR
S2
E-3
AR-L74 AR-L74
1 1
UP
S2.2
DN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
398
STAIR S2-4
70
ELEVATOR
S2
E-3
UP AR-L74
1
AR-L74
1
S2.5
DN
477
STAIR S2-5
S2
DN
AR-L74
1
AR-L74
1
TO ROOF
SHIP LADDER
DN
S2.6
398
STAIR S2-3
70
ELEVATOR
S2
E-3
UP AR-L74
1
AR-L74
1
S2.3
30 238
ELEV. MACH. CL
238
S2.4
EGRESS GATE
STAIR
DN
26 27
C
B.8
C
B.8
26 27
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
7
2
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SCALE:
REF: AR-L14
2
AR-L72 "=1'-0" SCALE:
REF: AR-L13
1
AR-L72 "=1'-0"
ENLARGED STAIR S3-1 PLAN ENLARGED STAIR S3-2 PLAN
4' 4' 0 8'
SCALE:"=1'-0"
ENLARGED STAIR PLANS S3
DECEMBER 2013
RJH
RJH
DAK

AR-L72
81 1/4"=1'-0"
LYTTONSVILLE YARD FACILITY
UP
265 S3
STAIR S3-1
S3.2
S3.1
DN
250 S3
STAIR S3-2
S3.3
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
7
3
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SCALE:
REF: AR-L12
" = 1'-0"
1
AR-L73
ENLARGED STAIR S4-1 PLAN SCALE:
REF: AR-L12
" = 1'-0"
2
AR-L73
ENLARGED STAIR S4-2 PLAN
4' 4' 0 8'
SCALE:"=1'-0"
ENLARGED STAIR PLANS S4
DECEMBER 2013
RJH
RJH
DAK

AR-L73
82 1/4"=1'-0"
LYTTONSVILLE YARD FACILITY
S4
STAIR 4-1
19 T @ 11" = 17'-5"
UP 20 R @ 7"
3
'
-
8
"
17'-5" 3'-0"
CANOPY ABOVE
280'-0"
YARD ELEVATION
4
'
-
8
"
S4
STAIR 4-2
19 T @ 11" = 17'-5"
UP 20 R @ 7"
CANOPY ABOVE
17'-5" 3'-0" 4'-0" 17'-5"
280'-0"
YARD ELEVATION
= 291'-8"
LANDING ELEVATION
19 T @ 11" = 17'-5"
UP 20 R @ 7"
= 305'-0"
WALKWAY ELEVATION
2 T @ 11" = 1'-10"
UP 3 R @ 7"
CANOPY ABOVE
WALL
CONCRETE KNEE
PARKING DECK
EDGE OF
5
'
-
0
"
5'-2"
3
'
-
8
"
3'-8" 1
9
'
-
1
1
"
= 303'-4"
LANDING ELEVATION
4'-5"
4
'
-
5

"
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
7
4
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SCALE:
REF: AR-L71
" = 1'-0"
1
AR-L74
SECTION STAIR S2
4' 4' 0 8'
SCALE:"=1'-0"
STAIR S2 SECTIONS
DECEMBER 2013
RJH
RJH
DAK

AR-L74
83 1/4"=1'-0"
LYTTONSVILLE YARD FACILITY
305'-6"
WALKWAY
305'-0"
DECK LEVEL
305'-8 1/2"
OFFICE 1ST FLR
312'-8 1/2"
INTERMEDIATE LANDING
319'-8 1/2"
OFFICE 2ND FLR
326'-8 1/2"
INTERMEDIATE LANDING
280'-0 1/2"
YARD LEVEL
284'-8 1/2"
INTERMEDIATE LANDING
333'-8 1/2"
OFFICE ROOF
291'-8 1/2"
YARD LEVEL ROOF
296'-4 1/2"
INTERMEDIATE LANDING
334'-8 1/2"
STAIR S2-5
301'-0 1/2"
INTERMEDIATE LANDING
ROOF BEHIND
ACCESS TO
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
8
0
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
DOOR SCHEDULES
DECEMBER 2013
RJH
RJH
DAK

AR-L80
84 N.T.S.
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
DOOR SCHEDULE NOTES:
1. TYPICAL DOOR HEIGHT: 7'-0" UNLESS NOTED OTHERWISE
2. TYPICAL DOOR THICKNESS: 1 3/4" UNLESS NOTED OTHERWISE
3. HEAD, JAMB AND SILL DETAILS ARE LOCATED ON DRAWING A8.XX UNLESS NOTED OTHERWISE
DOOR SCHEDULE DOOR SCHEDULE
UNISEX TOILET ROOM 100
ELECTRICAL 118
VESTIBULE 200
VESTIBULE 200
CORRIDOR 203
CORRIDOR 204
ELECTRICAL 211
MECHANICAL 212
EQUIPMENT 213
CORRIDOR 215
LIGHT RAIL BREAK ROOM 101
LIGHT RAIL OFFICE 102
LIGHT RAIL MAINTENANCE STORAGE 103
CLEANING SUPPLY STORAGE 104
CLEANING SUPPLY STORAGE 104
ELECTRICAL ROOM 105
BULK FLUID STORAGE 106
FIRE PROTECTION 107
FIRE PROTECTION 108
UNISEX TOILET ROOM 109
UNISEX TOILET ROOM 110
CLEANING BREAK ROOM 112
CLEANING OFFICE 113
WATER SERVICE 114
ELECTRICAL SERVICE 115
EMERGENCY ELECTRICAL SERVICE 116
COMMUNICATIONS CLOSET 119
FIRE PROTECTION 120
COMPRESSOR ROOM 121
STAIR 2 AT YARD LEVEL
STAIR 2 AT YARD LEVEL ROOF
TRANS. SUPERVISOR 206
ASST. TRANS. SUPERVISOR 207
WORK BLOCK COORDINATOR 208
UNISEX TOILET ROOM 210
LOST AND FOUND 214A
YARD MASTER 218
WASH BAY 117
WASH BAY 117
WASH BAY 117
WASH BAY 117
WASH BAY 117
WASH BAY 117
INCIDENT ROOM 219
SUPERVISOR 220
UNISEX TOILET ROOM 221
TECHNICIANS 223
EQUIPMENT 226
EQUIPMENT 226
UNISEX TOILET ROOM 227
CORRIDOR 228
QUIET ROOM 229
VESTIBULE 230
VESTIBULE 230
WOMENS TOILET ROOM
MENS TOILET ROOM
JANITOR CLOSET 236
BUILDING MAINTENANCE 237
ELEVATOR MACHINE CLOSET 238
ELEVATOR LOBBY 300
CORRIDOR 301
UNISEX TOILET ROOM 303
LIGHT RAIL DIRECTOR 306
INCIDENT ROOM 307
CONFERENCE 309
ELECTRICAL 311
COMMUNICATIONS ROOM 312
MECHANICAL 313
UNISEX TOILET ROOM 314
UNISEX TOILET ROOM 315
JANITOR CLOSET 318
CLASSROOM 320
TRAINING OFFICE 321
TRAINING OFFICE 321
STAIR 2 AT ROOF LEVEL
OFFICE 222
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0" I.T
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
4'-0"
3'-0"
3'-0"
NO.
100
101
102
103
105
106
107
108
109
110
112
113
114
115
116
118
119
120
121
S2.1
S2.2
S2.3
S2.4
201
202
203
204
206
207
208
210
211
212
213
214
215
218
SET
HDW
(NOM)
WIDTH
8'-0" X 10'-0"
3'-0" X 2
3'-0" X 2
104.1
104.2
117.1
117.2
117.3
117.4
117.5
117.6
200.1
200.2
DOORS FRAMES
LINT'L REMARKS
LOCATION TYPE MAT'L TYPE MAT'L HEAD JAMB SILL
FIRE RATING
FINISH
DOOR FRAME
D1 HM F1 HM
D1 HM F2 HM
D2 HM F2 HM
D6 HM F3 HM
D1 HM F2 HM
ALUM STL
D1 HM F2 HM
D6 HM F3 HM
D1 HM F2 HM
D1 HM F2 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F2 HM
D2 HM F1 HM
D1 HM F2 HM
D6 HM F3 HM
D1 HM F2 HM
D1 HM F2 HM
D1 HM F2 HM
D1 HM F2 HM
D1 HM F2 HM
ALUM STL
ALUM STL
D6 HM F3 HM
D6 HM F3 HM
D1 HM F2 HM
D6 HM F3 HM
D1 HM F2 HM
D1 HM F2 HM
D1 HM F1 HM
D1 HM F2 HM
D5 AL AL
D5 HM F1 HM
D2 HM F1 HM
D1 HM F1 HM
D2 HM F1 HM
D2 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D6 HM F3 HM
D6 HM F3 HM
D1 HM F1 HM
D1 HM F1 HM
HM HM
D2 HM F1 HM
D1 HM F1 HM
NO.
219 3'-0"
220 3'-0"
221 3'-0"
222 3'-0"
223 3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
227 3'-0"
228 3'-0"
229 3'-0"
3'-0"
3'-0"
233 3'-0"
SET
HDW
(NOM)
WIDTH
224.1
224.2
226.1
226.2
230.1
230.2
DOORS
LOCATION TYPE MAT'L TYPE MAT'L HEAD
FRAMES
LINT'L REMARKS
JAMB SILL
FIRE RATING
FINISH
DOOR FRAME
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D2 HM F1 HM
D1 HM F1 HM
D5 AL AL
D5 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D5 AL AL
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D2 HM F1 HM
D7 HM F3 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D2 HM F1 HM
D6 HM F3 HM
D1 HM F1 HM
D6 HM F3 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D1 HM F1 HM
D2 HM F1 HM
D2 HM F1 HM
D1 HM F1 HM
D11 AL AL
234 3'-0"
235 3'-0"
236 3'-0"
237 3'-0"
238 3'-0"
S3.1 3'-0"
S3.2 3'-0"
S2.5 3'-0"
S3.3 3'-0"
300 3'-0"
301
303 3'-0"
305 3'-0"
306 3'-0"
307 3'-0"
308 3'-0"
309 3'-0"
311
312 3'-0"
313
314 3'-0"
315 3'-0"
318 3'-0"
319 3'-0"
320 3'-0"
321.1 3'-0"
321.2 3'-0"
S2.6 3'-0"
3'-0" X 2
214A
L
O
C
A
T
I
O
N
O
F
F
I
C
E

F
I
R
S
T

F
L
O
O
R

A
T

D
E
C
K

L
E
V
E
L
O
F
F
I
C
E

S
E
C
O
N
D

F
L
O
O
R
P
E
N
T
H
O
U
S
E
L
O
C
A
T
I
O
N
Y
A
R
D


L
E
V
E
L
O
F
F
I
C
E

F
I
R
S
T

F
L
O
O
R

A
T

D
E
C
K

L
E
V
E
L
STAIR 2 AT OFFICE FIRST FLR
STAIR 2 AT OFFICE FIRST FLR
x12'-0"
24'-0"
x12'-0"
24'-0"
X 2
3'-0"
X 2
3'-0"
DISPATCH 214
LOBBY 201
STORAGE 319
I.T. 308
X 2
3'-0"
OPERATIONS CONTROL CTR 224
OPERATIONS CONTROL CTR 224
STAIR 3 AT OFFICE FIRST FL
STAIR 3 AT OFFICE FIRST FL
STAIR 2 AT OFFICE SECOND FL
STAIR 3 AT OFFICE SECOND FL
OPER BREAK RM /KITCHEN 235
LIGHT RAIL DEPUTY DIR 305
X 2
3'-0"
X 2
3'-0"
X 2
3'-0"
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
8
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
H1 H2 H3
J3 J2 J1
SCALE:
REF: AR-L80
" = 1'-0"
TYPICAL DOOR FRAMES AND DOOR TYPES 1
AR-L81
SCALE:
REF: AR-L80
" = 1'-0"
2
AR-L81
DOOR DETAILS
SCALE:
REF: AR-L80
" = 1'-0"
3
AR-L81
TYP. CORNER DETAIL
SCALE:
REF: AR-L80
" = 1'-0"
4
AR-L81
TYP. CORNER DETAIL AT CMU
2' 2' 0 4'
SCALE:"=1'-0"
DOOR AND MISCELLANEOUS DETAILS
DECEMBER 2013
RJH
RJH
DAK

AR-L81
85 AS SHOWN
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
2" 2"
3'-0"
7
'
-
0
"
2
"
F1 F2 F3 F4 F5 F6
D1 D2 D3 D4 D5 D6 D7 D8 D9 D10
2" 2"
3'-0"
4
"
7
'
-
0
"
2" 2"
6'-0"
7
'
-
0
"
2" 2"
2
"
2" 2"
2
"
7
'
-
0
"
2" 2"
6'-0"
2
"
7
'
-
0
"
3'-0"
2
" 1
'
-
1
0
"
1
'
-
1
0
"
2
"
SCHEDULED OPENING
O
P
E
N
I
N
G
S
C
H
E
D
U
L
E
D
D11
S
E
E

S
C
H
E
D
U
L
E
(TYP.)
JAMB ANCHOR
SPOT GROUT AT
DOOR
SCHEDULED
(TYP.)
STUDS AT JAMB
DOUBLE METAL
FRAME
METAL
(TYP.)
SEALANT
(TYP.)
SEALANT
AT HEAD
METAL STUD
JAMB)
(3 PER
ANCHORS
JAMB
WALL
SCHEDULED
GROUT
FILL W/
DOOR
SCHEDULED
(TYP.)
SEALANT
(TYP.)
SEALANT
(3 PER JAMB)
JAMB ANCHORS
WALL
SCHEDULED
LINTEL
SCHEDULED
D.O. 2" BULL NOSE
4"
(TYP.)
SEALANT
METAL FRAME
(TYP.)
JAMB ANCHOR
SPOT GROUT AT
METAL FRAME
PARTITION
SCHEDULED
TYPE JAMB ANCHOR
COMPRESSION LUG
AT JAMB (TYP.)
DOUBLE METAL STUDS
SCHEDULE
PARTITION
CMU - SEE
(4 PER JAMB)
ANCHORS
AND BUTTERFLY
3/8" DIA FH BOLTS
SECURE JAMB WITH
WALL IS ERECTED,
INSTALLING AFTER
JAMB) WHEN
ANCHORS (3 PER
WIRE OR "T"
EACH JAMB
BOTTOM OF
SCREWAT
BUGLE HEAD
FOR TYPE "S"
DIMPLED HOLE
PUNCHED AND
4"
2"
GROUT
WITH
FILL
DOOR
SCHEDULED
(TYP.)
SEALANT
(TYP.)
SEALANT
AT HEAD
METAL STUD
JAMB)
(3 PER
ANCHORS
JAMB
(TYP.)
JAMB ANCHOR
SPOT GROUT AT
(TYP.)
STUDS AT JAMB
DOUBLE METAL
FRAME
METAL
WALL
SCHEDULED
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
8
2
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SCALE:
REF: AR-L82
" = 1'-0"
1
AR-L82
WINDOW DETAIL
SCALE:
REF: AR-L82
" = 1'-0"
2
AR-L82
STOREFRONT DETAIL
4' 4' 0 8'
SCALE:"=1'-0"
WINDOW/ STOREFRONT SCHEDULE & DETAILS
DECEMBER 2013
RJH
RJH
DAK

AR-L82
86 AS SHOWN
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
W1 W2 W3 W4 W5 W6 W7 W8
W9 W10 W11 W12
7
'
-
7
"
2'-4" 8'-2" 5'-3" 5'-3" 8'-2" 8'-2" 6'-0" 6'-0"
7
'
-
8
"
2
'
-
0
"
3
'
-
6

"
4
'
-
1

"
5'-3"
2
'
-
0
"
2'-4" 8'-2"
3
'
-
0
"
3
'
-
0
"
5'-3"
2'-4" 2'-4" 2'-4"2'-11"2'-11"
3
'
-
6
"
1
'
-
2
"
4
'
-
7
"
2
'
-
4
"
2
'
-
5
"
7
'
-
0
"
2
"

T
Y
P
.
2" TYP.
2'-11"
2'-2"
2'-11"
2'-2"
2'-11"2'-11"
2'-0"
2'-11" 2'-11"
2'-2"
2'-11"
2'-2"
2'-11"
2'-2"
2'-11"2'-11" 2'-11"2'-11"
SF1A SF1B
SF2A
SF2B
1
3
'
-
8
"
1
3
'
-
1
"
8'-10" 12'-0" 23'-1" 5'-7"
1
7
'
-
2

"
1
0
'
-
0
"
6'-11" 6'-1" 5'-11" 5'-6" 5'-6" 5'-6" 5'-6" 5'-1"
13'-10"
WINDOW & STORE FRONT SCHEDULE
NO.
W1
W2
W3
W4
W5
W6
W7
W12
W11
W10
W9
W8
SF3
SF4
SF5
SF6
SF2B
SF2A
SF1B
SF1A
MAT'L
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
ALUM
13'-10" X 26'-9"
12'-1/2" X 26'-9"
23'-1" X 17'-2 1/2"
5'7" X 17'-2 1/2"
3'-4" X 24'-2 1/2"
6'-0" X 13'-4"
6'-4" X 10'-0"
5'-4 1/2" X 10'-0"
(WIDTH x HEIGHT)
NOMINAL ROUGH OPENING
DETAILS
HEAD JAMB SILL
LINTEL REMARKS
6'-0" X 7'-8"
6'-0" X 7'-8"
5'-3" X 7'-7"
5'-3" X 7'-7"
2'-4" X 7'-7"
8'-2" X 7'-7"
8'-2" X 7'-7"
8'-2" X 7'-7"
2'-4" X 2'-0"
5'-3" X 2'-0"
5'-3" X 2'-0"
8'-2" X 2'-0"
STORE FRONT
STORE FRONT
STORE FRONT
STORE FRONT
STORE FRONT
STORE FRONT
STORE FRONT
STORE FRONT
1. HEAD, JAMB AND SILL DETAILS ARE LOCATED ON THIS SHEET UNLESS NOTED OTHERWISE
WINDOWSCHEDULE NOTE(S):
SF3 SF4 SF5 SF6
3'-4"
6'-0"
6'-4" 5'-4"
1
0
'
-
0
"
7
'
-
0
"
7
'
-
0
"
7
'
-
0
"
2'-10" 2'-2"
7
'
-
2

"
3'-2" 3'-2"
1
3
'
-
4
"
2
4
'
-
2

"
1
0
'
-
0
"
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
6
8
0
9
\
1
0
4
2
p
A
R
L
A
8
4
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
FINISH SCHEDULE
DECEMBER 2013
RJH
RJH
DAK

AR-L84
87 NONE
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
ROOM FINISH SCHEDULE ROOM FINISH SCHEDULE
UNISEX TOILET ROOM
LIGHT RAIL BREAK ROOM
LIGHT RAIL OFFICE
LIGHT RAIL MAINTENANCE STORAGE
CLEANING SUPPLY STORAGE
ELECTRICAL ROOM
BULK FLUID STORAGE
FIRE PROTECTION
FIRE PROTECTION
UNISEX TOILET ROOM
UNISEX TOILET ROOM
CORRIDOR
CLEANING BREAK ROOM
CLEANING OFFICE
WATER SERVICE
ELECTRICAL SERVICE
EMERGENCY ELECTRICAL SERVICE
WASH BAY
ELECTRICAL
COMMUNICATIONS CLOSET
FIRE PROTECTION
COMPRESSOR ROOM
STAIR 2 AT YARD LEVEL
STAIR 2 AT YARD LEVEL ROOF
STAIR 2 AT OFFICE FIRST FLOOR
STAIR 3 AT OFFICE FIRST FLOOR
VESTIBULE
LOBBY
I.T.
CORRIDOR
CORRIDOR
ADMINISTRATION/COPY
TRANSPORTATION SUPERVISOR
WORK BLOCK COORDINATOR
TEAM ROOM
UNISEX TOILET ROOM
ELECTRICAL
MECHANICAL
EQUIPMENT
DISPATCH
LOST AND FOUND
CORRIDOR
CORRIDOR
TEAM ROOM
YARD MASTER
INCIDENT ROOM
*SEE RCP ON SHEET AR-L20
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*SEE RCP ON SHEET AR-L20
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*SEE RCP ON SHEET AR-L22
*SEE RCP ON SHEET AR-L22
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*SEE RCP ON SHEET AR-L22
SUPERVISOR
UNISEX TOILET ROOM
TECHNICIANS
OPERATIONS CONTROL CENTER
CORRIDOR
EQUIPMENT
UNISEX TOILET ROOM
CORRIDOR
QUIET ROOM
VESTIBULE
CORRIDOR
LOCKERS
WOMENS TOILET ROOM
MENS TOILET ROOM
OPERATOR BREAK ROOM/KITCHENETTE
JANITOR CLOSET
BUILDING MAINTENANCE
ELEVATOR MACHINE CLOSET
STAIR 2 AT OFFICE SECOND FLOOR
STAIR 3 AT OFFICE SECOND FLOOR
ELEVATOR LOBBY
CORRIDOR
CORRIDOR
UNISEX TOILET ROOM
ADMINISTRATION/COPY
LIGHT RAIL DEPUTY DIRECTOR
LIGHT RAIL DIRECTOR
INCIDENT ROOM
CONFERENCE
CORRIDOR
ELECTRICAL
COMMUNICATIONS ROOM
MECHANICAL
UNISEX TOILET ROOM
UNISEX TOILET ROOM
CORRIDOR
CORRIDOR
JANITOR CLOSET
STORAGE
CLASSROOM
TRAINING OFFICE
STAIR 2 AT ROOF LEVEL
*EXPOSED STRUCTURE
*SEE RCP ON SHEET AR-L22
*EXPOSED STRUCTURE
*SEE RCP ON SHEET AR-L22
*SEE RCP ON SHEET AR-L22
*SEE RCP ON SHEET AR-L22
*SEE RCP ON SHEET AR-L22
*SEE RCP ON SHEET AR-L22
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*SEE RCP ON SHEET AR-L23
*SEE RCP ON SHEET AR-L23
*SEE RCP ON SHEET AR-L23
*SEE RCP ON SHEET AR-L23
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*EXPOSED STRUCTURE
*SEE RCP ON SHEET AR-L23
*SEE RCP ON SHEET AR-L23
*EXPOSED STRUCTURE
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
S2
S2
122
S2
S3
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
214A
215
216
217
218
219
EPX EPX PT PT PT PT GYPB/APC* 8'-6"/9-0"*
CS VB PT PT PT PT APC 9'-0"
CS VB PT PT PT PT APC 9'-0"
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX EPX PT PT PT PT GYPB/APC* 8'-6"/9-0"*
EPX EPX PT PT PT PT APC 9'-0"
CS VB PT PT PT PT GYPB 8'-6"
CS VB PT PT PT PT APC 9'-0"
CS VB PT PT PT PT APC 9'-0"
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
EPX N/A PT PT PT PT EXP* EXP*
VB PT PT PT PT EXP* EXP*
VB PT PT PT PT EXP* EXP*
CS VB PT PT PT PT APC 9-0"
VB PT / S/F PT PT PT / S/F EXP* EXP*
VB PT PT PT PT EXP* EXP*
WOM/CS VB PT PT PT PT GYPB 10'-0"
CS VB PT PT PT PT GYPB/APC*
EPX VB PT PT PT PT APC 9-0"
VCT VB PT PT PT PT APC 10'-0"
VCT VB PT PT PT PT APC 10'-0"
VCT VB PT PT PT CW/PT APC 10'-0"
CARP VB PT CW/PT PT PT APC 10'-0"
CARP VB PT CW/PT PT PT APC 10'-0"
CARP VB PT PT PT CW/PT APC 10'-0"
VCT VB PT PT PT PT APC 10'-0"
EPX EPX PT PT PT PT APC/GYPB* 10'-0"
EPX EPX PT PT PT PT EXP* EXP*
EPX EPX PT PT PT PT EXP* EXP*
EPX EPX PT PT PT PT APC 10'-0"
CARP VB CW/PT CW/PT CW/PT PT APC 10'-0"
CARP VB PT PT PT PT GYPB 9-0"
VCT VB PT PT PT PT EXP* EXP*
VCT VB PT PT PT PT EXP* EXP*
VCT VB CW/PT CW/PT PT PT APC/EXP*
CARP VB PT PT CW/PT PT APC 10'-0"
CARP VB PT PT CW/PT PT APC 10'-0"
CARP VB PT PT PT PT APC 10'-0"
EPX EPX PT PT PT PT APC 9'-0"
CARP VB PT PT PT PT APC 10'-0"
CARP VB PT PT PT PT APC 10'-0"
VCT VB PT PT PT PT APC 10'-0"
VCT VB PT PT PT PT EXP* EXP*
VCT VB PT PT PT PT APC 10'-0"
EPX EPX PT PT PT PT GYPB/APC*
VCT VB PT PT PT PT EXP* EXP*
CS VB PT PT PT PT APC 10'-0"
WOM/CS VB PT PT PT PT GYPB 10'-0"
CS VB PT PT PT PT VARIES*
CS VB PT PT PT PT
EPX EPX PT PT PT PT
EPX EPX PT PT PT PT
CS VB PT PT PT PT VARIES*
EPX EPX PT PT PT PT APC 9'-0"
CARP VB PT PT PT PT APC 10'-0"
VCT VB PT PT PT PT EXP* EXP*
VB PT / S/F PT PT PT / S/F EXP* EXP*
VB PT PT PT PT EXP* EXP*
CS VB PT PT PT PT
VCT VB PT PT PT PT GYPB 9'-0"
VCT VB PT PT PT PT GYPB 9'-0"
EPX EPX PT PT PT PT
VCT VB PT PT PT PT APC 10'-0"
CARP VB PT PT PT PT APC 10'-0"
CARP VB PT PT PT PT APC 10'-0"
CARP VB PT PT PT PT
CARP VB PT PT PT PT APC 9'-0"
VCT VB PT PT
VCT VB PT PT PT PT EXP* EXP*
EPX EPX PT PT PT PT EXP* EXP*
EPX EPX PT PT PT PT EXP* EXP*
EPX EPX PT PT PT PT EXP* EXP*
EPX EPX PT PT PT PT
EPX EPX PT PT PT PT APC 9'-0"
VCT VB PT PT PT PT GYPB 9'-0"
VCT VB PT PT PT PT GYPB 9'-0"
EPX EPX PT PT PT PT APC 9'-0"
CARP VB PT PT PT PT APC 9'-0"
CARP VB PT PT PT PT
CARP VB PT PT PT PT APC 10'-0"
VB PT PT PT PT EXP* EXP*
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
S2
S3
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
S2
DESCRIPTION FLOOR BASE
WALLS CEILING
REMARKS
NORTH EAST SOUTH WEST TYPE HEIGHT
DESCRIPTION FLOOR BASE
WALLS CEILING
REMARKS
NORTH EAST SOUTH WEST TYPE HEIGHT
O
F
F
I
C
E

F
I
R
S
T

F
L
O
O
R

A
T

D
E
C
K

L
E
V
E
L
Y
A
R
D

L
E
V
E
L
L
O
C
A
T
I
O
N
L
O
C
A
T
I
O
N
O
F
F
I
C
E

F
I
R
S
T

F
L
O
O
R

A
T

D
E
C
K

L
E
V
E
L
O
F
F
I
C
E

S
E
C
O
N
D

F
L
O
O
R
P
E
N
T
H
O
U
S
E
ELEVATOR LOBBY AT BROOKVILLE RD
EXP*
9'-0"/
EXP
10'-0"/
/EXP*
APC/GYPB
9'-0"*
8'-6"/
EXP*
9'-0"/
/10-0"*
9'-0"
/10-0"*
9'-0"
/EXP*
GYPB
/EXP*
9'-0"
/APC*
GYPB
/9'-0"*
8'-6"
/APC*
GYPB
/10'-0"*
9'-0"
/EXP*
APC
/EXP*
9'-0"
/APC*
GYPB
/9'-0"*
8'-6"
S/F
PT /
S/F
PT /
/10'-0"*
9'-0"
/APC*
GYPB
/EXP*
GYPB
/APC*
GYPB
/APC*
GYPB
/EXP*
APC
NO.
ROOM
NO.
ROOM
OFFICE
I.T.
ASSISTANT TRANSPORTATION SUPERV.
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
4
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
E
q
u
i p
m
e
n
t
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
A
R
L
A
9
0
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
EQUIPMENT LIST

ABBREVIATIONS
KEYED NOTES
A. GENERAL NOTES

B. EQUIPMENT NOTES
1
2
3
LRV = LIGHT RAIL VEHICLE
6. REFER TO CIVIL DRAWINGS FOR EXTERIOR EQUIPMENT
5. FINAL DESIGNER SHOULD VERIFY ALL EQUIPMENT MEETS APPLICABLE CODES AND STANDARDS.
EFFICIENT POSITION AND ORIENTATION.
BE LOCATED NEAR THE LOCATION SHOWN ON DRAWINGS BUT IN THE MOST OPERATIONALLY
UNLESS SPECIFICALLY LOCATED BY DIMENSIONS ON THE DRAWINGS. THE EQUIPMENT SHALL
LOCATION. THE EQUIPMENT LAYOUT IS PROVIDED FOR GENERAL LOCATION OF EQUIPMENT
4. EQUIPMENT PLAN DRAWINGS ARE PREPARED TO SCALE FOR BOTH EQUIPMENT SIZE AND
AND PLUMBING REQUIREMENTS OF EQUIPMENT WITH MANUFACTURERS APPROVED SHOP DRAWINGS.
3. CONTRACTOR TO VERIFY AND COORDINATE ALL STRUCTURAL, MECHANICAL, ELECTRICAL,
2. ALL EQUIPMENT WILL BE CONTRACTOR FURNISHED.
DRAWINGS.
1. FINAL SIZES AND LOCATIONS SHOULD BE VERIFIED WITH APPROVED MANUFACTURER SHOP
EQUIPMENT ID. NO. TR2 AND REMOTE STATION.
CONTRACTOR SHALL COORDINATE CONTROLS, WATER, AND HIGH PRESSURE PIPING BETWEEN
EQUIPMENT IN THE WASH BAY.
ALL INTERCONNECTING PIPING AND ELECTRICAL WORK BETWEEN PANELS, PUMPS, AND WASH
APPROVED WASHER MANUFACTURER. CONTRACTOR AND MANUFACTURER SHALL COORDINATE
AND CHANGING ANY UNDER-SLAB OR EMBEDDED PIPING AND CONDUIT AS REQUIRED BY THE
CLEANING CAPABILITY OF THE WASH SYSTEM. CONTRACTOR IS RESPONSIBLE FOR VERIFYING
IS RESPONSIBLE FOR PROVIDING LAYOUT OF EQUIPMENT IN WASH BAY THAT MAXIMIZES THE
WASHER, LRV, WITH RECLAIM ID. NO. TR3 IS BASED ON A SPECIFIC MANUFACTURER. CONTRACTOR
REFERENCE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR DETAILS.
6" HIGH HOUSEKEEPING PAD FOR COMPRESSOR. COORDINATE SIZE WITH EQUIPMENT,
EQUIPMENT NOTES AND EQUIPMENT LIST
DECEMBER 2013
KAG
KAG
TMD

AR-L90
88 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
A
12 15.1 13 14 15 16 17 18 19
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
4
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
E
q
u
i p
m
e
n
t
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
A
R
L
A
9
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8 8 0 16
SCALE:"=1-0"
N
1
AR-L91 "=1-0" SCALE:

YARD LEVEL EQUIPMENT PLAN
1
NOTES:
DRAWING AR-L90.
FOR EQUIPMENT LIST, REFER TO 2.
AR-L90.
FOR EQUIPMENT NOTES, REFER TO DRAWING 1.
YARD LEVEL - EQUIPMENT PLAN
DECEMBER 2013
KAG
KAG
TMD

AR-L91
89 1/8"=1-0"
LYTTONSVILLE YARD FACILITY
LC1
FOR EXL2
CARTS
SANDING
S
L
1
FOR EXL2
CART
SANDING
EP1 EP1
EP1 EP1
T.R.
UNISEX
ROOM
BREAK
L.R.
OFFICE
L.R. STORAGE
L.R. MAINT.
SUPPLY STORAGE
CLEANING
STORAGE
BULK FLUID
PROTECT.
FIRE
ROOM
LUBE
COMPRESSOR/
EMERGENCY PIT
24-0" 24-0" 24-0" 22-0"
4-0"
22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0" 22-0"
4-0"
22-0" 24-0" 24-0"
LC1
FOR EXL2
CARTS
SANDING
S
L
1
FOR EXL2
CART
SANDING
EP1 EP1
EP1 EP1
T.R.
UNISEX
ROOM
BREAK
L.R.
OFFICE
L.R. STORAGE
L.R. MAINT.
SUPPLY STORAGE
CLEANING
STORAGE
BULK FLUID
PROTECT.
FIRE
ROOM
LUBE
COMPRESSOR/
EMERGENCY PIT
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
4
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
E
q
u
i p
m
e
n
t
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
A
R
L
A
9
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8 8 0 16
SCALE:"=1-0"
N
"=1-0"
1
AR-L92

WASH BUILDING EQUIPMENT PLAN
SCALE:

2
3
NOTES:
DRAWING AR-L90.
FOR EQUIPMENT LIST, REFER TO 2.
AR-L90.
FOR EQUIPMENT NOTES, REFER TO DRAWING 1.
WASH BUILDING - EQUIPMENT PLAN
DECEMBER 2013
KAG
KAG
TMD

AR-L92
90 1/8"=1-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
KEY PLAN
E
F
F.1
31-9" 25-8" 25-8" 23-3" 25-8"
4-4"
15-10"
4

-
0
"
2
2

-
2

"
7.7 8.9 10.1 11.1 12.2 13.1 13 13.3
2
5

-
0
"
2
3

-
8

"
135-0"
4

-
0
"
23-3" 80-0"
TR3
TR2
TR1
TR1 ELEC. COMM. CL.
TRAIN WASH
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
GENERAL STRUCTURAL NOTES - SHEET 1 OF 2
DECEMBER 2013
BT
JE
RG

ST-L01
91 NTS
LYTTONSVILLE YARD FACILITY
I.5
I.4
I.3
I.2
I.1
GENERAL STRUCTURAL NOTES:
III. 13 STEEL GRATING
III. 12 LIGHT GAGE STEEL STUDS
III. 11 HANDRAILS, GUARDRAILS AND LADDERS
III. 10 BACKFILL
III. 9 SLABS ON GRADE
III. 8 FOUNDATION
III. 7 MASONRY

III. 6 SOIL BEARING
III. 5 STRUCTURAL STEEL

III. 4 REINFORCEMENT STEEL

III. 3 CONCRETE PROTECTION FOR REINFORCEMENT AND WELDED WIRE FABRIC(WWF)

III. 2 CONCRETE
III. 1 CEMENT

III. STRUCTURAL MATERIALS

II. 2. 2 WIND LOAD
II. 2. 5 DEAD LOAD
II.2.4 SNOW LOAD
II.2.2 SEISMIC
II.2.1 LIVE LOADS
II.2 DESIGN LOADS
II.1 CODES AND STANDARDS
II DESIGN CRITERIA
I.GENERAL
6.1
6.
5.8
5.7
5.6
5.5
5.4
5.3
5.2
5.1
5.
3.1
3.
2.
1.
OF THE SAME DEPTH AS THE BEARING BARS.
BAND OUTSIDE EDGES OF GRATING AND ALL OPENINGS IN GRATING USING BARS
BBG 531. ATTACH ALL GRATING TO STEEL MEMBERS WITH WELD-ON ANCHORS.
OF ARCHITECTURAL METAL MANUFACTURERS, "METAL BAR GRATING MANUAL" NAAM
FABRICATE ALL STEEL GRATING IN ACCORDANCE WITH THE NATIONAL ASSOCIATION


ASTM A653 AND HAVE A MINIMUM YIELD STRENGTH OF 33 KSI.
SPECIFICATIONS. ALL STEEL SHALL BE GALVANIZED IN ACCORDANCE WITH
DESIGN AND CONSTRUCTION OF STEEL STUDS SHALL CONFORM TO AISC

BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARS.
ALL LADDERS SHALL BE DESIGNED AT A MINIMUM TO SUSTAIN LOADS AS REQUIRED
PER IBC 2012.
AND MEZZANINES, THE DESIGN SHALL BE BASED ON LOADING REQUIREMENTS AS
FOR HANDRAILS AND TOP RAILS OF GUARDS OTHER THAN ON STATION PLATFORM
LOAD OF 100 PLF AT THE TOP.
SIMULTANEOUS APPLICATION OF A HORIZONTAL LOAD OF 150 PLF AND A VERTCAL
RAILINGS ON STATION PLATFORMS AND MEZZANINES SHALL BE DESIGNED FOR THE
TO ASTM A312 GRADE TP321.
ALL GUARDRAILS AND HANDRAILS SHALL CONSIST OF STAINLESS STEEL CONFORMING

OF THE MTA DESIGN CRITERIA AND THE SOIL REPORT.
MATERIALS USED FOR BACKFILL SHALL BE IN ACCORDANCE WITH CHAPTER 13

CONSULTANTS RECOMMENDATION FOR SUB GRADE PREPARATION.
REQUIREMENTS OF MTA DESIGN CRITERIA SECTION 11. 5. 6 - I. SEE SOIL
OVER A 6 IN. LAYER OF WASHED GRAVEL. THE VAPOR BARRIER SHALL MEET THE
SLABS ON GRADE SHALL BE LAID ON A LAYER OF 10 MIL MINIMUM POLYETHYLENE
PROVIDE CONTROL JOINTS EACH WAY IN ALL EXTERIOR SLAB ON GRADE.
ALL EXTERIOR SLABS ON GRADE SHALL BE AIR ENTRAINED WITH 6% + 1%.

SHALL BE LEAST 2-6" BELOWFINISHED GRADE.
BOTTOM OF ALL EXTERIOR FOOTINGS AND FOOTINGS IN UNHEATED SPACES
BY A SOIL CONSULTANT.
THE REQUIRED SOIL BEARING CAPACITY SHALL BE CHECKED AND VERIFIED
DO NOT PLACE CONCRETE OVER FROZEN SOIL.
TO 1 VERTICAL) TO A FOOTING.
NO EXCAVATION SHALL BE CLOSER THAN AT A SLOPE OF 2:1 (2 HORIZONTAL
CONCRETE IS PLACED.
ALL BEARING TRATA SHALL BE ADEQUATELY DRAINED BEFORE FOUNDATION
CONCRETE (fc = 2000 psi).
ALL DISTURBED EARTH UNDER FOOTINGS SHALL BE REPLACED WITH LEAN
FOR SUB GRADE PREPARATION.
LEAST EQUAL TO THAT SPECIFIED IN THE SOIL REPORT. SEE SOIL REPORT
SOIL OR THE COMPACTED CONTROLLED FILL HAVING A BEARING VALUE AT
ALL FOOTINGS SHALL PROJECT AT LEAST 1-0" INTO UNDISTURBED NATURAL

SEE SPECIFICATIONS FOR BRICKS.
IN HORIZONTALLY.
WALL OR STEEL STUD. SPACE TIES AT 16" ON CENTER VERTICALLY AND 24"
PROVIDE MASONRY TIES BETWEEN 4" THICK BRICK VENEER WALL AND MASONRY
PROVIDE DOVETAIL ANCHORS SLOTS INTO MASONRY AT 16" ON CENTER UNO.
OF STRUCTURE.
DOVETAIL ANCHOR SHALL BE 2-0" MAX. ON CENTER WHERE MASONRY ABUTS FACES
DESIGN OF MASONRY IS BASED ON INSPECTED CONSTRUCTION.
ASTM C476 WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS.
HEIGHT, GROUTED WITH PEA GRAVEL CONCRETE. GROUT SHALL CONFORM TO
ALL MASONRY WALLS TO BE REINFORCED WITH #5 @24. IN ON CENTER, FULL
ALL MORTAR JOINTS IN MASONRY WALLS SHALL BE FILLED 100% WITH MORTAR.
CENTER .
PROVIDE VERTICAL CONTROL JOINTS IN ALL MASONRY WALLS AT 30-0" MAX. ON
MASONRY WALLS UNO.
PROVIDE HORIZONTAL MASONRY REINFORCING AT 16" ON CENTER IN ALL
CONSTRUCTION. USE TYPE "M" FOR BELOWGRADE.
ALL MORTAR SHALL BE TYPE "S" CONFORMING TO ASTM C270 FOR ABOVE GRADE
BEARING AND fm = 1500 PSI FOR NON-LOAD BEARING.
COMPRESSIVE STRENGTH OF MASONRY ASSEMBLAGE fm = 2000 PSI FOR LOAD
CONCRETE MASONRY UNITS SHALL BE MADE WITH LIGHTWEIGHT CONCRETE.
ASTM C129 FOR NON-LOAD BEARING UNITS.
CONCRETE MASONRY SHALL CONFORM TO ASTM C90 FOR LOAD-BEARING UNITS AND

SEE SOIL REPORT.
CAN START THEIR WORK.
ALL STEEL ERECTION SHALL BE COMPLETED, INCLUDING ALL BRACING BEFORE OTHER TRADES
ALL STEEL PERMANENTLY EXPOSED TO WEATHER OR SOIL SHALL BE HOT DIP GALVANIZED (G90).
OF THE STRUCTURAL ENGINEER.
NO FIELD CUTTING OF STEEL MEMBERS SHALL BE PERMITTED WITHOUT PRIOR AUTORIZATION
SEE SPECIFICATIONS FOR PAINTING.
WASHERS AND NUTS SHALL CONFORM TO ASTM F436 AND A563 RESPECTIVELY.
ALL FULL PENETRATION WELDS SHALL BE TESTED BY ULTRASONIC METHOD.
ALL ERECTED STEEL AND CONNECTIONS SHALL BE INSPECTED BY A QUALIFIED INSPECTOR.
TEARING.
ESTABLISH SPECIAL PROCEDURES FOR WELDS LARGER THAN " TO PREVENT LAMELLAR
ALL WELDS TO BE " FILLET, MINIMUM 3" LONG UNLESS OTHERWISE REQUIRED.
1-2010 USING ELECTRODES E70XX.
ALL WELDING SHALL MEET THE REQUIREMENTS OF STRUCTURAL WELDING CODE AWS D1.
HIGH STRENGTH BOLTS IN ACCORDANCE WITH ASTM A325.
SHOP AND FIELD CONNECTIONS SHALL BE WELDED OR MADE WITH " DIAMETER MINIMUM,
ASTM A36.
ALL MISCELLANEOUS STEEL (PLATES, ANGLES, CHANNELS AND BARS) SHALL CONFORM TO
SHALL BE ZINC COATED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM F1554.
ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE 36 UNLESS NOTED OTHERWISE AND
STEEL PIPES TO CONFORM TO ASTM A53, GRADE B.
STRUCTURAL TUBING (HSS) TO CONFORM TO ASTM A500, GRADE B.
ALL WIDE FLANGE STRUCTURAL SHAPES SHALL CONFORM TO ASTM A992, GRADE 50.

ALL CONTINUOUS REINFORCING SHALL BE SPLICED AND STAGGERED,UNLESS NOTED OTHERWISE.
DETAILING MANUAL - 2004 (SP-66) AND TECHNICAL SPECIFICATIONS SECTION 03210.
REINFORCEMENT DETAILS SHALL CONFORM TO THE REQUIREMENTS OF ACI 318-11, ACI
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185.
ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60.

SALB ON GRADE: WWF TO BE PLACED AT MID-DEPTH, UNO.
2" FOR REBARS #6 AND GREATER (EXPOSED TO EARTH OR WEATER)
1" FOR REBARS #5 AND SMALLER (EXPOSED TO EARTH OR WEATHER)
SLABS AND WALLS; 1" (NOT EXPOSED TO EARTH AND WEATHER)
BEAMS AND COLUMNS: 1"
REBARS), 2" (TOP REBARS)
FOOTINGS AND OTHER STRUCTURE POURED AGAINST EARTH: 3" (BOTTOM AND SIDE
REINFORCING BARS SHALL HAVE CONCRETE COVER AS FOLLOWS:


ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR ENTRAINED WITH 6% +/- 1%.
f c = 3500 PSI CONCRETE FOR TOPPING ON INTERIOR METAL DECK.
SLABS, WALLS, BEAMS ETC.
f c = 4500 PSI CONCRETE FOR FOOTINGS, SLAB ON GRADE, GRADE BEAMS, FRAMED
28 - DAY CYLINDER COMPRESSIVE STRENGTH SHALL BE AS FOLLOWS:
ALL CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-11

TYPE I, II OR III CEMENT (PER PROJECT SPECIFICATIONS) SHALL BE USED




EXPOSURE CATEGORY C
IMPORTANCE FACTOR (Iw) 1.15
DESIGN WIND PRESSURE (MWFRS) 20 PSF
BASIC WIND SPEED (V) 110 MPH

CHAPTER 11 TABLE 4
STRUCTURAL SYSTEM DEAD LOAD SHALL BE DETERMINED AS PER MTA DESIGN CRITERIA

SNOWDRIFT: WHERE APPLICABLE
IMPORTANCE FACTOR 1.1
EXPOSURE FACTOR 1.2
THERMAL FACTOR 1.0

GROUND SNOWLOAD 20 PSF (MONTGOMERY COUNTY)

IMPORTANCE FACTOR (IE) 1.25
Sd1 0.08
Sds 0.17
S1 0.05
Ss 0.16
SITE CLASSIFICATION D
SEISMIC DESIGN CATEGORY B

REFER TO THE BASIS OF DESIGN FOR THE DESIGN LIVE LOADS REQUIREMENTS.
INTERNATIONAL BUILDING CODE (IBC) 2012 EDITION
ICCS APPLICABLE CODES
COUNTY OF MONTGOMERY
RED AND PURPLE LINE SUSTAINABLE DESIGN CHECKLIST.
FEDERALLY FUNDED PROJECTS ONLY, JUNE 2001.
SUPPLEMENTARY GENERAL PROVISIONS FOR CONSTRUCTION CONTRACTS,

GENERAL PROVISIONS FOR CONSTRUCTION CONTRACTS, OCTOBER 2001.

FEBRUARY 7, 2006.
REQUIREMENTS OF QUALITY MANAGEMENT PLAN FOR A/E DESIGN CONSULTANT,
AUGUST 27, 2007.
OFFICE OF ENGINEERING AND CONSTRUCTION, QUALITY ASSURANCE PROGRAM PLAN,

DRAWING AND CADD STANDARDS FOR MICROSTATION V8 XM, REVISION 1.1 FEBRUARY 25, 2011.
MTA RED/PURPLE LIGHT RAIL DESIGN CRITERIA.
MARYLAND TRANSIT ADMINISTRATION.

INTERNATIONAL BUILDING CODE (IBC) 2012 EDITION.
DEVELOPMENT(DHCD) MODIFICATIONS.
AND COMMUNITY
MARYLAND BUILDING PERFORMANCE STANDARDS (MBPS) WITH THE DEPARTMENT OF HOUSING
STATE OF MARYLAND BUILDING CODE
CODES AND STANDARDS LISTED IN THE BASIS OF DESIGN
INTERNATIONAL BUILDING CODE (IBC) 2012


WITH THE WORK.
CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING
PRIOR TO PROCEEDING WITH WORK. VARIATIONS BETWEEN DRAWINGS AND ACTUAL EXISTING
DESIGN BUILDER SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS
SHOWN ON STRUCTURAL DRAWINGS.
OPENINGS, SLEEVES, EMBEDDED ITEMS, UNDERGROUND PIPING & ELECTRICAL GROUNDING NOT
SEE ARCHITECTURAL, MECHANICAL,PLUMBING & ELECTRICAL DRAWINGS FOR ADDITIONAL
SHALL BE CHANGED ONLY WITH THE APPROVAL OF THE ENGINEER.
DIMENSIONS SHALL BE VERIFIED WITH THE ACTUAL EQUIPMENT PURCHASED.DIMENSIONS
ANCHORAGE HAVE BEEN DETERMINED USING SPECIFIC MANUFACTURERS EQUIPMENT.FINAL
DIMENSIONS OF EQUIPMENT OPENINGS, SUPPORTS, PADS, SLAB DEPRESSIONS, FOUNDATIONS &

APPROVAL.
DESIGN BUILDER. ALTERNATIVES TO THE DETAILS SHOWN MAY BE SUBJECT TO OWNER
DETAILS AND COORDINATION WITH OTHER DISCIPLINES ARE THE RESPONSIBILITY OF THE
EFFORTS AND ARE SUGGESTED STRUCTURAL DESIGN ONLY. FOUNDATION DESIGN, SIZING
THE DESIGN DEPICTED IN THIS SET OF DRAWINGS REPERESENTS PRELIMINARY ENGINEERING
SPECIFICATIONS AND THE ISSUED DRAWINGS.
GENERAL NOTES ARE TO BE READ IN CONJUNCTION WITH PROJECT TECHNICAL



3.
2.
1.
3.
2.
1.
16.
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
III. 13 STEEL GRATING
III. 12 LIGHT GAGE STEEL STUDS
III. 11 HANDRAILS, GUARDRAILS AND LADDERS
III. 10 BACKFILL
III. 9 SLABS ON GRADE
III. 8 FOUNDATION
III. 7 MASONRY

III. 6 SOIL BEARING
III. 5 STRUCTURAL STEEL

III. 4 REINFORCEMENT STEEL

III. 3 CONCRETE PROTECTION FOR REINFORCEMENT AND WELDED WIRE FABRIC(WWF)

III. 2 CONCRETE
III. 1 CEMENT

III. STRUCTURAL MATERIALS

II. 2. 2 WIND LOAD
II. 2. 5 DEAD LOAD
II.2.4 SNOW LOAD
II.2.2 SEISMIC
II.2.1 LIVE LOADS
II.2 DESIGN LOADS
II.1 CODES AND STANDARDS
II DESIGN CRITERIA
I.GENERAL
4.
3.
2.
1.
OF THE SAME DEPTH AS THE BEARING BARS.
BAND OUTSIDE EDGES OF GRATING AND ALL OPENINGS IN GRATING USING BARS
BBG 531. ATTACH ALL GRATING TO STEEL MEMBERS WITH WELD-ON ANCHORS.
OF ARCHITECTURAL METAL MANUFACTURERS, "METAL BAR GRATING MANUAL" NAAM
FABRICATE ALL STEEL GRATING IN ACCORDANCE WITH THE NATIONAL ASSOCIATION


ASTM A653 AND HAVE A MINIMUM YIELD STRENGTH OF 33 KSI.
SPECIFICATIONS. ALL STEEL SHALL BE GALVANIZED IN ACCORDANCE WITH
DESIGN AND CONSTRUCTION OF STEEL STUDS SHALL CONFORM TO AISC

BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARS.
ALL LADDERS SHALL BE DESIGNED AT A MINIMUM TO SUSTAIN LOADS AS REQUIRED
PER IBC 2012.
AND MEZZANINES, THE DESIGN SHALL BE BASED ON LOADING REQUIREMENTS AS
FOR HANDRAILS AND TOP RAILS OF GUARDS OTHER THAN ON STATION PLATFORM
LOAD OF 100 PLF AT THE TOP.
SIMULTANEOUS APPLICATION OF A HORIZONTAL LOAD OF 150 PLF AND A VERTCAL
RAILINGS ON STATION PLATFORMS AND MEZZANINES SHALL BE DESIGNED FOR THE
TO ASTM A312 GRADE TP321.
ALL GUARDRAILS AND HANDRAILS SHALL CONSIST OF STAINLESS STEEL CONFORMING

OF THE MTA DESIGN CRITERIA AND THE SOIL REPORT.
MATERIALS USED FOR BACKFILL SHALL BE IN ACCORDANCE WITH CHAPTER 13

CONSULTANTS RECOMMENDATION FOR SUB GRADE PREPARATION.
REQUIREMENTS OF MTA DESIGN CRITERIA SECTION 11. 5. 6 - I. SEE SOIL
OVER A 6 IN. LAYER OF WASHED GRAVEL. THE VAPOR BARRIER SHALL MEET THE
SLABS ON GRADE SHALL BE LAID ON A LAYER OF 10 MIL MINIMUM POLYETHYLENE
PROVIDE CONTROL JOINTS EACH WAY IN ALL EXTERIOR SLAB ON GRADE.
ALL EXTERIOR SLABS ON GRADE SHALL BE AIR ENTRAINED WITH 6% + 1%.

SHALL BE LEAST 2-6" BELOWFINISHED GRADE.
BOTTOM OF ALL EXTERIOR FOOTINGS AND FOOTINGS IN UNHEATED SPACES
BY A SOIL CONSULTANT.
THE REQUIRED SOIL BEARING CAPACITY SHALL BE CHECKED AND VERIFIED
DO NOT PLACE CONCRETE OVER FROZEN SOIL.
TO 1 VERTICAL) TO A FOOTING.
NO EXCAVATION SHALL BE CLOSER THAN AT A SLOPE OF 2:1 (2 HORIZONTAL
CONCRETE IS PLACED.
ALL BEARING TRATA SHALL BE ADEQUATELY DRAINED BEFORE FOUNDATION
CONCRETE (fc = 2000 psi).
ALL DISTURBED EARTH UNDER FOOTINGS SHALL BE REPLACED WITH LEAN
FOR SUB GRADE PREPARATION.
LEAST EQUAL TO THAT SPECIFIED IN THE SOIL REPORT. SEE SOIL REPORT
SOIL OR THE COMPACTED CONTROLLED FILL HAVING A BEARING VALUE AT
ALL FOOTINGS SHALL PROJECT AT LEAST 1-0" INTO UNDISTURBED NATURAL

SEE SPECIFICATIONS FOR BRICKS.
IN HORIZONTALLY.
WALL OR STEEL STUD. SPACE TIES AT 16" ON CENTER VERTICALLY AND 24"
PROVIDE MASONRY TIES BETWEEN 4" THICK BRICK VENEER WALL AND MASONRY
PROVIDE DOVETAIL ANCHORS SLOTS INTO MASONRY AT 16" ON CENTER UNO.
OF STRUCTURE.
DOVETAIL ANCHOR SHALL BE 2-0" MAX. ON CENTER WHERE MASONRY ABUTS FACES
DESIGN OF MASONRY IS BASED ON INSPECTED CONSTRUCTION.
ASTM C476 WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS.
HEIGHT, GROUTED WITH PEA GRAVEL CONCRETE. GROUT SHALL CONFORM TO
ALL MASONRY WALLS TO BE REINFORCED WITH #5 @24. IN ON CENTER, FULL
ALL MORTAR JOINTS IN MASONRY WALLS SHALL BE FILLED 100% WITH MORTAR.
CENTER .
PROVIDE VERTICAL CONTROL JOINTS IN ALL MASONRY WALLS AT 30-0" MAX. ON
MASONRY WALLS UNO.
PROVIDE HORIZONTAL MASONRY REINFORCING AT 16" ON CENTER IN ALL
CONSTRUCTION. USE TYPE "M" FOR BELOWGRADE.
ALL MORTAR SHALL BE TYPE "S" CONFORMING TO ASTM C270 FOR ABOVE GRADE
BEARING AND fm = 1500 PSI FOR NON-LOAD BEARING.
COMPRESSIVE STRENGTH OF MASONRY ASSEMBLAGE fm = 2000 PSI FOR LOAD
CONCRETE MASONRY UNITS SHALL BE MADE WITH LIGHTWEIGHT CONCRETE.
ASTM C129 FOR NON-LOAD BEARING UNITS.
CONCRETE MASONRY SHALL CONFORM TO ASTM C90 FOR LOAD-BEARING UNITS AND

SEE SOIL REPORT.
CAN START THEIR WORK.
ALL STEEL ERECTION SHALL BE COMPLETED, INCLUDING ALL BRACING BEFORE OTHER TRADES
ALL STEEL PERMANENTLY EXPOSED TO WEATHER OR SOIL SHALL BE HOT DIP GALVANIZED (G90).
OF THE STRUCTURAL ENGINEER.
NO FIELD CUTTING OF STEEL MEMBERS SHALL BE PERMITTED WITHOUT PRIOR AUTORIZATION
SEE SPECIFICATIONS FOR PAINTING.
WASHERS AND NUTS SHALL CONFORM TO ASTM F436 AND A563 RESPECTIVELY.
ALL FULL PENETRATION WELDS SHALL BE TESTED BY ULTRASONIC METHOD.
ALL ERECTED STEEL AND CONNECTIONS SHALL BE INSPECTED BY A QUALIFIED INSPECTOR.
TEARING.
ESTABLISH SPECIAL PROCEDURES FOR WELDS LARGER THAN " TO PREVENT LAMELLAR
ALL WELDS TO BE " FILLET, MINIMUM 3" LONG UNLESS OTHERWISE REQUIRED.
1-2010 USING ELECTRODES E70XX.
ALL WELDING SHALL MEET THE REQUIREMENTS OF STRUCTURAL WELDING CODE AWS D1.
HIGH STRENGTH BOLTS IN ACCORDANCE WITH ASTM A325.
SHOP AND FIELD CONNECTIONS SHALL BE WELDED OR MADE WITH " DIAMETER MINIMUM,
ASTM A36.
ALL MISCELLANEOUS STEEL (PLATES, ANGLES, CHANNELS AND BARS) SHALL CONFORM TO
SHALL BE ZINC COATED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM F1554.
ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE 36 UNLESS NOTED OTHERWISE AND
STEEL PIPES TO CONFORM TO ASTM A53, GRADE B.
STRUCTURAL TUBING (HSS) TO CONFORM TO ASTM A500, GRADE B.
ALL WIDE FLANGE STRUCTURAL SHAPES SHALL CONFORM TO ASTM A992, GRADE 50.

ALL CONTINUOUS REINFORCING SHALL BE SPLICED AND STAGGERED,UNLESS NOTED OTHERWISE.
DETAILING MANUAL - 2004 (SP-66) AND TECHNICAL SPECIFICATIONS SECTION 03210.
REINFORCEMENT DETAILS SHALL CONFORM TO THE REQUIREMENTS OF ACI 318-11, ACI
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185.
ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60.

SALB ON GRADE: WWF TO BE PLACED AT MID-DEPTH, UNO.
2" FOR REBARS #6 AND GREATER (EXPOSED TO EARTH OR WEATER)
1" FOR REBARS #5 AND SMALLER (EXPOSED TO EARTH OR WEATHER)
SLABS AND WALLS; 1" (NOT EXPOSED TO EARTH AND WEATHER)
BEAMS AND COLUMNS: 1"
REBARS), 2" (TOP REBARS)
FOOTINGS AND OTHER STRUCTURE POURED AGAINST EARTH: 3" (BOTTOM AND SIDE
REINFORCING BARS SHALL HAVE CONCRETE COVER AS FOLLOWS:


ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR ENTRAINED WITH 6% +/- 1%.
f c = 3500 PSI CONCRETE FOR TOPPING ON INTERIOR METAL DECK.
SLABS, WALLS, BEAMS ETC.
f c = 4500 PSI CONCRETE FOR FOOTINGS, SLAB ON GRADE, GRADE BEAMS, FRAMED
28 - DAY CYLINDER COMPRESSIVE STRENGTH SHALL BE AS FOLLOWS:
ALL CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-11

TYPE I, II OR III CEMENT (PER PROJECT SPECIFICATIONS) SHALL BE USED




EXPOSURE CATEGORY C
IMPORTANCE FACTOR (Iw) 1.15
DESIGN WIND PRESSURE (MWFRS) 20 PSF
BASIC WIND SPEED (V) 110 MPH

CHAPTER 11 TABLE 4
STRUCTURAL SYSTEM DEAD LOAD SHALL BE DETERMINED AS PER MTA DESIGN CRITERIA

SNOWDRIFT: WHERE APPLICABLE
IMPORTANCE FACTOR 1.1
EXPOSURE FACTOR 1.2
THERMAL FACTOR 1.0

GROUND SNOWLOAD 20 PSF (MONTGOMERY COUNTY)

IMPORTANCE FACTOR (IE) 1.25
Sd1 0.08
Sds 0.17
S1 0.05
Ss 0.16
SITE CLASSIFICATION D
SEISMIC DESIGN CATEGORY B

REFER TO THE BASIS OF DESIGN FOR THE DESIGN LIVE LOADS REQUIREMENTS.
INTERNATIONAL BUILDING CODE (IBC) 2012 EDITION
ICCS APPLICABLE CODES
COUNTY OF MONTGOMERY
RED AND PURPLE LINE SUSTAINABLE DESIGN CHECKLIST.
FEDERALLY FUNDED PROJECTS ONLY, JUNE 2001.
SUPPLEMENTARY GENERAL PROVISIONS FOR CONSTRUCTION CONTRACTS,

GENERAL PROVISIONS FOR CONSTRUCTION CONTRACTS, OCTOBER 2001.

FEBRUARY 7, 2006.
REQUIREMENTS OF QUALITY MANAGEMENT PLAN FOR A/E DESIGN CONSULTANT,
AUGUST 27, 2007.
OFFICE OF ENGINEERING AND CONSTRUCTION, QUALITY ASSURANCE PROGRAM PLAN,

DRAWING AND CADD STANDARDS FOR MICROSTATION V8 XM, REVISION 1.1 FEBRUARY 25, 2011.
MTA RED/PURPLE LIGHT RAIL DESIGN CRITERIA.
MARYLAND TRANSIT ADMINISTRATION.

INTERNATIONAL BUILDING CODE (IBC) 2012 EDITION.
DEVELOPMENT(DHCD) MODIFICATIONS.
AND COMMUNITY
MARYLAND BUILDING PERFORMANCE STANDARDS (MBPS) WITH THE DEPARTMENT OF HOUSING
STATE OF MARYLAND BUILDING CODE
CODES AND STANDARDS LISTED IN THE BASIS OF DESIGN
INTERNATIONAL BUILDING CODE (IBC) 2012


WITH THE WORK.
CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING
PRIOR TO PROCEEDING WITH WORK. VARIATIONS BETWEEN DRAWINGS AND ACTUAL EXISTING
DESIGN BUILDER SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS
SHOWN ON STRUCTURAL DRAWINGS.
OPENINGS, SLEEVES, EMBEDDED ITEMS, UNDERGROUND PIPING & ELECTRICAL GROUNDING NOT
SEE ARCHITECTURAL, MECHANICAL,PLUMBING & ELECTRICAL DRAWINGS FOR ADDITIONAL
SHALL BE CHANGED ONLY WITH THE APPROVAL OF THE ENGINEER.
DIMENSIONS SHALL BE VERIFIED WITH THE ACTUAL EQUIPMENT PURCHASED.DIMENSIONS
ANCHORAGE HAVE BEEN DETERMINED USING SPECIFIC MANUFACTURERS EQUIPMENT.FINAL
DIMENSIONS OF EQUIPMENT OPENINGS, SUPPORTS, PADS, SLAB DEPRESSIONS, FOUNDATIONS &

APPROVAL.
DESIGN BUILDER. ALTERNATIVES TO THE DETAILS SHOWN MAY BE SUBJECT TO OWNER
DETAILS AND COORDINATION WITH OTHER DISCIPLINES ARE THE RESPONSIBILITY OF THE
EFFORTS AND ARE SUGGESTED STRUCTURAL DESIGN ONLY. FOUNDATION DESIGN, SIZING
THE DESIGN DEPICTED IN THIS SET OF DRAWINGS REPERESENTS PRELIMINARY ENGINEERING
SPECIFICATIONS AND THE ISSUED DRAWINGS.
GENERAL NOTES ARE TO BE READ IN CONJUNCTION WITH PROJECT TECHNICAL



16.
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
7.
6.
5.
4.
3.
2.
1.
III. 13 STEEL GRATING
III. 12 LIGHT GAGE STEEL STUDS
III. 11 HANDRAILS, GUARDRAILS AND LADDERS
III. 10 BACKFILL
III. 9 SLABS ON GRADE
III. 8 FOUNDATION
III. 7 MASONRY

III. 6 SOIL BEARING
III. 5 STRUCTURAL STEEL

III. 4 REINFORCEMENT STEEL

III. 3 CONCRETE PROTECTION FOR REINFORCEMENT AND WELDED WIRE FABRIC(WWF)

III. 2 CONCRETE
III. 1 CEMENT

III. STRUCTURAL MATERIALS

II. 2. 2 WIND LOAD
II. 2. 5 DEAD LOAD
II.2.4 SNOW LOAD
II.2.2 SEISMIC
II.2.1 LIVE LOADS
II.2 DESIGN LOADS
II.1 CODES AND STANDARDS
II DESIGN CRITERIA
I.GENERAL
OF THE SAME DEPTH AS THE BEARING BARS.
BAND OUTSIDE EDGES OF GRATING AND ALL OPENINGS IN GRATING USING BARS
BBG 531. ATTACH ALL GRATING TO STEEL MEMBERS WITH WELD-ON ANCHORS.
OF ARCHITECTURAL METAL MANUFACTURERS, "METAL BAR GRATING MANUAL" NAAM
FABRICATE ALL STEEL GRATING IN ACCORDANCE WITH THE NATIONAL ASSOCIATION


ASTM A653 AND HAVE A MINIMUM YIELD STRENGTH OF 33 KSI.
SPECIFICATIONS. ALL STEEL SHALL BE GALVANIZED IN ACCORDANCE WITH
DESIGN AND CONSTRUCTION OF STEEL STUDS SHALL CONFORM TO AISC

BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARS.
ALL LADDERS SHALL BE DESIGNED AT A MINIMUM TO SUSTAIN LOADS AS REQUIRED
PER IBC 2012.
AND MEZZANINES, THE DESIGN SHALL BE BASED ON LOADING REQUIREMENTS AS
FOR HANDRAILS AND TOP RAILS OF GUARDS OTHER THAN ON STATION PLATFORM
LOAD OF 100 PLF AT THE TOP.
SIMULTANEOUS APPLICATION OF A HORIZONTAL LOAD OF 150 PLF AND A VERTCAL
RAILINGS ON STATION PLATFORMS AND MEZZANINES SHALL BE DESIGNED FOR THE
TO ASTM A312 GRADE TP321.
ALL GUARDRAILS AND HANDRAILS SHALL CONSIST OF STAINLESS STEEL CONFORMING

OF THE MTA DESIGN CRITERIA AND THE SOIL REPORT.
MATERIALS USED FOR BACKFILL SHALL BE IN ACCORDANCE WITH CHAPTER 13

CONSULTANTS RECOMMENDATION FOR SUB GRADE PREPARATION.
REQUIREMENTS OF MTA DESIGN CRITERIA SECTION 11. 5. 6 - I. SEE SOIL
OVER A 6 IN. LAYER OF WASHED GRAVEL. THE VAPOR BARRIER SHALL MEET THE
SLABS ON GRADE SHALL BE LAID ON A LAYER OF 10 MIL MINIMUM POLYETHYLENE
PROVIDE CONTROL JOINTS EACH WAY IN ALL EXTERIOR SLAB ON GRADE.
ALL EXTERIOR SLABS ON GRADE SHALL BE AIR ENTRAINED WITH 6% + 1%.

SHALL BE LEAST 2-6" BELOWFINISHED GRADE.
BOTTOM OF ALL EXTERIOR FOOTINGS AND FOOTINGS IN UNHEATED SPACES
BY A SOIL CONSULTANT.
THE REQUIRED SOIL BEARING CAPACITY SHALL BE CHECKED AND VERIFIED
DO NOT PLACE CONCRETE OVER FROZEN SOIL.
TO 1 VERTICAL) TO A FOOTING.
NO EXCAVATION SHALL BE CLOSER THAN AT A SLOPE OF 2:1 (2 HORIZONTAL
CONCRETE IS PLACED.
ALL BEARING TRATA SHALL BE ADEQUATELY DRAINED BEFORE FOUNDATION
CONCRETE (fc = 2000 psi).
ALL DISTURBED EARTH UNDER FOOTINGS SHALL BE REPLACED WITH LEAN
FOR SUB GRADE PREPARATION.
LEAST EQUAL TO THAT SPECIFIED IN THE SOIL REPORT. SEE SOIL REPORT
SOIL OR THE COMPACTED CONTROLLED FILL HAVING A BEARING VALUE AT
ALL FOOTINGS SHALL PROJECT AT LEAST 1-0" INTO UNDISTURBED NATURAL

SEE SPECIFICATIONS FOR BRICKS.
IN HORIZONTALLY.
WALL OR STEEL STUD. SPACE TIES AT 16" ON CENTER VERTICALLY AND 24"
PROVIDE MASONRY TIES BETWEEN 4" THICK BRICK VENEER WALL AND MASONRY
PROVIDE DOVETAIL ANCHORS SLOTS INTO MASONRY AT 16" ON CENTER UNO.
OF STRUCTURE.
DOVETAIL ANCHOR SHALL BE 2-0" MAX. ON CENTER WHERE MASONRY ABUTS FACES
DESIGN OF MASONRY IS BASED ON INSPECTED CONSTRUCTION.
ASTM C476 WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS.
HEIGHT, GROUTED WITH PEA GRAVEL CONCRETE. GROUT SHALL CONFORM TO
ALL MASONRY WALLS TO BE REINFORCED WITH #5 @24. IN ON CENTER, FULL
ALL MORTAR JOINTS IN MASONRY WALLS SHALL BE FILLED 100% WITH MORTAR.
CENTER .
PROVIDE VERTICAL CONTROL JOINTS IN ALL MASONRY WALLS AT 30-0" MAX. ON
MASONRY WALLS UNO.
PROVIDE HORIZONTAL MASONRY REINFORCING AT 16" ON CENTER IN ALL
CONSTRUCTION. USE TYPE "M" FOR BELOWGRADE.
ALL MORTAR SHALL BE TYPE "S" CONFORMING TO ASTM C270 FOR ABOVE GRADE
BEARING AND fm = 1500 PSI FOR NON-LOAD BEARING.
COMPRESSIVE STRENGTH OF MASONRY ASSEMBLAGE fm = 2000 PSI FOR LOAD
CONCRETE MASONRY UNITS SHALL BE MADE WITH LIGHTWEIGHT CONCRETE.
ASTM C129 FOR NON-LOAD BEARING UNITS.
CONCRETE MASONRY SHALL CONFORM TO ASTM C90 FOR LOAD-BEARING UNITS AND

SEE SOIL REPORT.
CAN START THEIR WORK.
ALL STEEL ERECTION SHALL BE COMPLETED, INCLUDING ALL BRACING BEFORE OTHER TRADES
ALL STEEL PERMANENTLY EXPOSED TO WEATHER OR SOIL SHALL BE HOT DIP GALVANIZED (G90).
OF THE STRUCTURAL ENGINEER.
NO FIELD CUTTING OF STEEL MEMBERS SHALL BE PERMITTED WITHOUT PRIOR AUTORIZATION
SEE SPECIFICATIONS FOR PAINTING.
WASHERS AND NUTS SHALL CONFORM TO ASTM F436 AND A563 RESPECTIVELY.
ALL FULL PENETRATION WELDS SHALL BE TESTED BY ULTRASONIC METHOD.
ALL ERECTED STEEL AND CONNECTIONS SHALL BE INSPECTED BY A QUALIFIED INSPECTOR.
TEARING.
ESTABLISH SPECIAL PROCEDURES FOR WELDS LARGER THAN " TO PREVENT LAMELLAR
ALL WELDS TO BE " FILLET, MINIMUM 3" LONG UNLESS OTHERWISE REQUIRED.
1-2010 USING ELECTRODES E70XX.
ALL WELDING SHALL MEET THE REQUIREMENTS OF STRUCTURAL WELDING CODE AWS D1.
HIGH STRENGTH BOLTS IN ACCORDANCE WITH ASTM A325.
SHOP AND FIELD CONNECTIONS SHALL BE WELDED OR MADE WITH " DIAMETER MINIMUM,
ASTM A36.
ALL MISCELLANEOUS STEEL (PLATES, ANGLES, CHANNELS AND BARS) SHALL CONFORM TO
SHALL BE ZINC COATED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM F1554.
ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE 36 UNLESS NOTED OTHERWISE AND
STEEL PIPES TO CONFORM TO ASTM A53, GRADE B.
STRUCTURAL TUBING (HSS) TO CONFORM TO ASTM A500, GRADE B.
ALL WIDE FLANGE STRUCTURAL SHAPES SHALL CONFORM TO ASTM A992, GRADE 50.

ALL CONTINUOUS REINFORCING SHALL BE SPLICED AND STAGGERED,UNLESS NOTED OTHERWISE.
DETAILING MANUAL - 2004 (SP-66) AND TECHNICAL SPECIFICATIONS SECTION 03210.
REINFORCEMENT DETAILS SHALL CONFORM TO THE REQUIREMENTS OF ACI 318-11, ACI
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185.
ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60.

SALB ON GRADE: WWF TO BE PLACED AT MID-DEPTH, UNO.
2" FOR REBARS #6 AND GREATER (EXPOSED TO EARTH OR WEATER)
1" FOR REBARS #5 AND SMALLER (EXPOSED TO EARTH OR WEATHER)
SLABS AND WALLS; 1" (NOT EXPOSED TO EARTH AND WEATHER)
BEAMS AND COLUMNS: 1"
REBARS), 2" (TOP REBARS)
FOOTINGS AND OTHER STRUCTURE POURED AGAINST EARTH: 3" (BOTTOM AND SIDE
REINFORCING BARS SHALL HAVE CONCRETE COVER AS FOLLOWS:


ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR ENTRAINED WITH 6% +/- 1%.
f c = 3500 PSI CONCRETE FOR TOPPING ON INTERIOR METAL DECK.
SLABS, WALLS, BEAMS ETC.
f c = 4500 PSI CONCRETE FOR FOOTINGS, SLAB ON GRADE, GRADE BEAMS, FRAMED
28 - DAY CYLINDER COMPRESSIVE STRENGTH SHALL BE AS FOLLOWS:
ALL CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-11

TYPE I, II OR III CEMENT (PER PROJECT SPECIFICATIONS) SHALL BE USED




EXPOSURE CATEGORY C
IMPORTANCE FACTOR (Iw) 1.15
DESIGN WIND PRESSURE (MWFRS) 20 PSF
BASIC WIND SPEED (V) 110 MPH

CHAPTER 11 TABLE 4
STRUCTURAL SYSTEM DEAD LOAD SHALL BE DETERMINED AS PER MTA DESIGN CRITERIA

SNOWDRIFT: WHERE APPLICABLE
IMPORTANCE FACTOR 1.1
EXPOSURE FACTOR 1.2
THERMAL FACTOR 1.0

GROUND SNOWLOAD 20 PSF (MONTGOMERY COUNTY)

IMPORTANCE FACTOR (IE) 1.25
Sd1 0.08
Sds 0.17
S1 0.05
Ss 0.16
SITE CLASSIFICATION D
SEISMIC DESIGN CATEGORY B

REFER TO THE BASIS OF DESIGN FOR THE DESIGN LIVE LOADS REQUIREMENTS.
INTERNATIONAL BUILDING CODE (IBC) 2012 EDITION
ICCS APPLICABLE CODES
COUNTY OF MONTGOMERY
RED AND PURPLE LINE SUSTAINABLE DESIGN CHECKLIST.
FEDERALLY FUNDED PROJECTS ONLY, JUNE 2001.
SUPPLEMENTARY GENERAL PROVISIONS FOR CONSTRUCTION CONTRACTS,

GENERAL PROVISIONS FOR CONSTRUCTION CONTRACTS, OCTOBER 2001.

FEBRUARY 7, 2006.
REQUIREMENTS OF QUALITY MANAGEMENT PLAN FOR A/E DESIGN CONSULTANT,
AUGUST 27, 2007.
OFFICE OF ENGINEERING AND CONSTRUCTION, QUALITY ASSURANCE PROGRAM PLAN,

DRAWING AND CADD STANDARDS FOR MICROSTATION V8 XM, REVISION 1.1 FEBRUARY 25, 2011.
MTA RED/PURPLE LIGHT RAIL DESIGN CRITERIA.
MARYLAND TRANSIT ADMINISTRATION.

INTERNATIONAL BUILDING CODE (IBC) 2012 EDITION.
DEVELOPMENT(DHCD) MODIFICATIONS.
AND COMMUNITY
MARYLAND BUILDING PERFORMANCE STANDARDS (MBPS) WITH THE DEPARTMENT OF HOUSING
STATE OF MARYLAND BUILDING CODE
CODES AND STANDARDS LISTED IN THE BASIS OF DESIGN
INTERNATIONAL BUILDING CODE (IBC) 2012


WITH THE WORK.
CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING
PRIOR TO PROCEEDING WITH WORK. VARIATIONS BETWEEN DRAWINGS AND ACTUAL EXISTING
DESIGN BUILDER SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS
SHOWN ON STRUCTURAL DRAWINGS.
OPENINGS, SLEEVES, EMBEDDED ITEMS, UNDERGROUND PIPING & ELECTRICAL GROUNDING NOT
SEE ARCHITECTURAL, MECHANICAL,PLUMBING & ELECTRICAL DRAWINGS FOR ADDITIONAL
SHALL BE CHANGED ONLY WITH THE APPROVAL OF THE ENGINEER.
DIMENSIONS SHALL BE VERIFIED WITH THE ACTUAL EQUIPMENT PURCHASED.DIMENSIONS
ANCHORAGE HAVE BEEN DETERMINED USING SPECIFIC MANUFACTURERS EQUIPMENT.FINAL
DIMENSIONS OF EQUIPMENT OPENINGS, SUPPORTS, PADS, SLAB DEPRESSIONS, FOUNDATIONS &

APPROVAL.
DESIGN BUILDER. ALTERNATIVES TO THE DETAILS SHOWN MAY BE SUBJECT TO OWNER
DETAILS AND COORDINATION WITH OTHER DISCIPLINES ARE THE RESPONSIBILITY OF THE
EFFORTS AND ARE SUGGESTED STRUCTURAL DESIGN ONLY. FOUNDATION DESIGN, SIZING
THE DESIGN DEPICTED IN THIS SET OF DRAWINGS REPERESENTS PRELIMINARY ENGINEERING
SPECIFICATIONS AND THE ISSUED DRAWINGS.
GENERAL NOTES ARE TO BE READ IN CONJUNCTION WITH PROJECT TECHNICAL



PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
GENERAL STRUCTURAL NOTES - SHEET 2 OF 2
DECEMBER 2013
BT
JE
RG

ST-L02
92 NTS
LYTTONSVILLE YARD FACILITY
7.
6.
5.
4.
3.
2.
1.
2.
1.
4.
3.
2.
1.
III. 13 STEEL GRATING
III. 12 LIGHT GAGE STEEL STUDS
III. 11 HANDRAILS, GUARDRAILS AND LADDERS
III. 10 BACKFILL
III. 9 SLABS ON GRADE
III. 8 FOUNDATION
III. 7 MASONRY

III. 6 SOIL BEARING
III. 5 STRUCTURAL STEEL

III. 4 REINFORCEMENT STEEL

III. 3 CONCRETE PROTECTION FOR REINFORCEMENT AND WELDED WIRE FABRIC(WWF)

III. 2 CONCRETE
III. 1 CEMENT

III. STRUCTURAL MATERIALS

II. 2. 2 WIND LOAD
II. 2. 5 DEAD LOAD
II.2.4 SNOW LOAD
II.2.2 SEISMIC
II.2.1 LIVE LOADS
II.2 DESIGN LOADS
II.1 CODES AND STANDARDS
II DESIGN CRITERIA
I.GENERAL
OF THE SAME DEPTH AS THE BEARING BARS.
BAND OUTSIDE EDGES OF GRATING AND ALL OPENINGS IN GRATING USING BARS
BBG 531. ATTACH ALL GRATING TO STEEL MEMBERS WITH WELD-ON ANCHORS.
OF ARCHITECTURAL METAL MANUFACTURERS, "METAL BAR GRATING MANUAL" NAAM
FABRICATE ALL STEEL GRATING IN ACCORDANCE WITH THE NATIONAL ASSOCIATION


ASTM A653 AND HAVE A MINIMUM YIELD STRENGTH OF 33 KSI.
SPECIFICATIONS. ALL STEEL SHALL BE GALVANIZED IN ACCORDANCE WITH
DESIGN AND CONSTRUCTION OF STEEL STUDS SHALL CONFORM TO AISC

BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARS.
ALL LADDERS SHALL BE DESIGNED AT A MINIMUM TO SUSTAIN LOADS AS REQUIRED
PER IBC 2012.
AND MEZZANINES, THE DESIGN SHALL BE BASED ON LOADING REQUIREMENTS AS
FOR HANDRAILS AND TOP RAILS OF GUARDS OTHER THAN ON STATION PLATFORM
LOAD OF 100 PLF AT THE TOP.
SIMULTANEOUS APPLICATION OF A HORIZONTAL LOAD OF 150 PLF AND A VERTCAL
RAILINGS ON STATION PLATFORMS AND MEZZANINES SHALL BE DESIGNED FOR THE
TO ASTM A312 GRADE TP321.
ALL GUARDRAILS AND HANDRAILS SHALL CONSIST OF STAINLESS STEEL CONFORMING

OF THE MTA DESIGN CRITERIA AND THE SOIL REPORT.
MATERIALS USED FOR BACKFILL SHALL BE IN ACCORDANCE WITH CHAPTER 13

CONSULTANTS RECOMMENDATION FOR SUB GRADE PREPARATION.
REQUIREMENTS OF MTA DESIGN CRITERIA SECTION 11. 5. 6 - I. SEE SOIL
OVER A 6 IN. LAYER OF WASHED GRAVEL. THE VAPOR BARRIER SHALL MEET THE
SLABS ON GRADE SHALL BE LAID ON A LAYER OF 10 MIL MINIMUM POLYETHYLENE
PROVIDE CONTROL JOINTS EACH WAY IN ALL EXTERIOR SLAB ON GRADE.
ALL EXTERIOR SLABS ON GRADE SHALL BE AIR ENTRAINED WITH 6% + 1%.

SHALL BE LEAST 2-6" BELOWFINISHED GRADE.
BOTTOM OF ALL EXTERIOR FOOTINGS AND FOOTINGS IN UNHEATED SPACES
BY A SOIL CONSULTANT.
THE REQUIRED SOIL BEARING CAPACITY SHALL BE CHECKED AND VERIFIED
DO NOT PLACE CONCRETE OVER FROZEN SOIL.
TO 1 VERTICAL) TO A FOOTING.
NO EXCAVATION SHALL BE CLOSER THAN AT A SLOPE OF 2:1 (2 HORIZONTAL
CONCRETE IS PLACED.
ALL BEARING TRATA SHALL BE ADEQUATELY DRAINED BEFORE FOUNDATION
CONCRETE (fc = 2000 psi).
ALL DISTURBED EARTH UNDER FOOTINGS SHALL BE REPLACED WITH LEAN
FOR SUB GRADE PREPARATION.
LEAST EQUAL TO THAT SPECIFIED IN THE SOIL REPORT. SEE SOIL REPORT
SOIL OR THE COMPACTED CONTROLLED FILL HAVING A BEARING VALUE AT
ALL FOOTINGS SHALL PROJECT AT LEAST 1-0" INTO UNDISTURBED NATURAL

SEE SPECIFICATIONS FOR BRICKS.
IN HORIZONTALLY.
WALL OR STEEL STUD. SPACE TIES AT 16" ON CENTER VERTICALLY AND 24"
PROVIDE MASONRY TIES BETWEEN 4" THICK BRICK VENEER WALL AND MASONRY
PROVIDE DOVETAIL ANCHORS SLOTS INTO MASONRY AT 16" ON CENTER UNO.
OF STRUCTURE.
DOVETAIL ANCHOR SHALL BE 2-0" MAX. ON CENTER WHERE MASONRY ABUTS FACES
DESIGN OF MASONRY IS BASED ON INSPECTED CONSTRUCTION.
ASTM C476 WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AT 28 DAYS.
HEIGHT, GROUTED WITH PEA GRAVEL CONCRETE. GROUT SHALL CONFORM TO
ALL MASONRY WALLS TO BE REINFORCED WITH #5 @24. IN ON CENTER, FULL
ALL MORTAR JOINTS IN MASONRY WALLS SHALL BE FILLED 100% WITH MORTAR.
CENTER .
PROVIDE VERTICAL CONTROL JOINTS IN ALL MASONRY WALLS AT 30-0" MAX. ON
MASONRY WALLS UNO.
PROVIDE HORIZONTAL MASONRY REINFORCING AT 16" ON CENTER IN ALL
CONSTRUCTION. USE TYPE "M" FOR BELOWGRADE.
ALL MORTAR SHALL BE TYPE "S" CONFORMING TO ASTM C270 FOR ABOVE GRADE
BEARING AND fm = 1500 PSI FOR NON-LOAD BEARING.
COMPRESSIVE STRENGTH OF MASONRY ASSEMBLAGE fm = 2000 PSI FOR LOAD
CONCRETE MASONRY UNITS SHALL BE MADE WITH LIGHTWEIGHT CONCRETE.
ASTM C129 FOR NON-LOAD BEARING UNITS.
CONCRETE MASONRY SHALL CONFORM TO ASTM C90 FOR LOAD-BEARING UNITS AND

SEE SOIL REPORT.
CAN START THEIR WORK.
ALL STEEL ERECTION SHALL BE COMPLETED, INCLUDING ALL BRACING BEFORE OTHER TRADES
ALL STEEL PERMANENTLY EXPOSED TO WEATHER OR SOIL SHALL BE HOT DIP GALVANIZED (G90).
OF THE STRUCTURAL ENGINEER.
NO FIELD CUTTING OF STEEL MEMBERS SHALL BE PERMITTED WITHOUT PRIOR AUTORIZATION
SEE SPECIFICATIONS FOR PAINTING.
WASHERS AND NUTS SHALL CONFORM TO ASTM F436 AND A563 RESPECTIVELY.
ALL FULL PENETRATION WELDS SHALL BE TESTED BY ULTRASONIC METHOD.
ALL ERECTED STEEL AND CONNECTIONS SHALL BE INSPECTED BY A QUALIFIED INSPECTOR.
TEARING.
ESTABLISH SPECIAL PROCEDURES FOR WELDS LARGER THAN " TO PREVENT LAMELLAR
ALL WELDS TO BE " FILLET, MINIMUM 3" LONG UNLESS OTHERWISE REQUIRED.
1-2010 USING ELECTRODES E70XX.
ALL WELDING SHALL MEET THE REQUIREMENTS OF STRUCTURAL WELDING CODE AWS D1.
HIGH STRENGTH BOLTS IN ACCORDANCE WITH ASTM A325.
SHOP AND FIELD CONNECTIONS SHALL BE WELDED OR MADE WITH " DIAMETER MINIMUM,
ASTM A36.
ALL MISCELLANEOUS STEEL (PLATES, ANGLES, CHANNELS AND BARS) SHALL CONFORM TO
SHALL BE ZINC COATED IN ACCORDANCE WITH THE REQUIREMENTS OF ASTM F1554.
ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE 36 UNLESS NOTED OTHERWISE AND
STEEL PIPES TO CONFORM TO ASTM A53, GRADE B.
STRUCTURAL TUBING (HSS) TO CONFORM TO ASTM A500, GRADE B.
ALL WIDE FLANGE STRUCTURAL SHAPES SHALL CONFORM TO ASTM A992, GRADE 50.

ALL CONTINUOUS REINFORCING SHALL BE SPLICED AND STAGGERED,UNLESS NOTED OTHERWISE.
DETAILING MANUAL - 2004 (SP-66) AND TECHNICAL SPECIFICATIONS SECTION 03210.
REINFORCEMENT DETAILS SHALL CONFORM TO THE REQUIREMENTS OF ACI 318-11, ACI
WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185.
ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60.

SALB ON GRADE: WWF TO BE PLACED AT MID-DEPTH, UNO.
2" FOR REBARS #6 AND GREATER (EXPOSED TO EARTH OR WEATER)
1" FOR REBARS #5 AND SMALLER (EXPOSED TO EARTH OR WEATHER)
SLABS AND WALLS; 1" (NOT EXPOSED TO EARTH AND WEATHER)
BEAMS AND COLUMNS: 1"
REBARS), 2" (TOP REBARS)
FOOTINGS AND OTHER STRUCTURE POURED AGAINST EARTH: 3" (BOTTOM AND SIDE
REINFORCING BARS SHALL HAVE CONCRETE COVER AS FOLLOWS:


ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR ENTRAINED WITH 6% +/- 1%.
f c = 3500 PSI CONCRETE FOR TOPPING ON INTERIOR METAL DECK.
SLABS, WALLS, BEAMS ETC.
f c = 4500 PSI CONCRETE FOR FOOTINGS, SLAB ON GRADE, GRADE BEAMS, FRAMED
28 - DAY CYLINDER COMPRESSIVE STRENGTH SHALL BE AS FOLLOWS:
ALL CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 318-11

TYPE I, II OR III CEMENT (PER PROJECT SPECIFICATIONS) SHALL BE USED




EXPOSURE CATEGORY C
IMPORTANCE FACTOR (Iw) 1.15
DESIGN WIND PRESSURE (MWFRS) 20 PSF
BASIC WIND SPEED (V) 110 MPH

CHAPTER 11 TABLE 4
STRUCTURAL SYSTEM DEAD LOAD SHALL BE DETERMINED AS PER MTA DESIGN CRITERIA

SNOWDRIFT: WHERE APPLICABLE
IMPORTANCE FACTOR 1.1
EXPOSURE FACTOR 1.2
THERMAL FACTOR 1.0

GROUND SNOWLOAD 20 PSF (MONTGOMERY COUNTY)

IMPORTANCE FACTOR (IE) 1.25
Sd1 0.08
Sds 0.17
S1 0.05
Ss 0.16
SITE CLASSIFICATION D
SEISMIC DESIGN CATEGORY B

REFER TO THE BASIS OF DESIGN FOR THE DESIGN LIVE LOADS REQUIREMENTS.
INTERNATIONAL BUILDING CODE (IBC) 2012 EDITION
ICCS APPLICABLE CODES
COUNTY OF MONTGOMERY
RED AND PURPLE LINE SUSTAINABLE DESIGN CHECKLIST.
FEDERALLY FUNDED PROJECTS ONLY, JUNE 2001.
SUPPLEMENTARY GENERAL PROVISIONS FOR CONSTRUCTION CONTRACTS,

GENERAL PROVISIONS FOR CONSTRUCTION CONTRACTS, OCTOBER 2001.

FEBRUARY 7, 2006.
REQUIREMENTS OF QUALITY MANAGEMENT PLAN FOR A/E DESIGN CONSULTANT,
AUGUST 27, 2007.
OFFICE OF ENGINEERING AND CONSTRUCTION, QUALITY ASSURANCE PROGRAM PLAN,

DRAWING AND CADD STANDARDS FOR MICROSTATION V8 XM, REVISION 1.1 FEBRUARY 25, 2011.
MTA RED/PURPLE LIGHT RAIL DESIGN CRITERIA.
MARYLAND TRANSIT ADMINISTRATION.

INTERNATIONAL BUILDING CODE (IBC) 2012 EDITION.
DEVELOPMENT(DHCD) MODIFICATIONS.
AND COMMUNITY
MARYLAND BUILDING PERFORMANCE STANDARDS (MBPS) WITH THE DEPARTMENT OF HOUSING
STATE OF MARYLAND BUILDING CODE
CODES AND STANDARDS LISTED IN THE BASIS OF DESIGN
INTERNATIONAL BUILDING CODE (IBC) 2012


WITH THE WORK.
CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING
PRIOR TO PROCEEDING WITH WORK. VARIATIONS BETWEEN DRAWINGS AND ACTUAL EXISTING
DESIGN BUILDER SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS
SHOWN ON STRUCTURAL DRAWINGS.
OPENINGS, SLEEVES, EMBEDDED ITEMS, UNDERGROUND PIPING & ELECTRICAL GROUNDING NOT
SEE ARCHITECTURAL, MECHANICAL,PLUMBING & ELECTRICAL DRAWINGS FOR ADDITIONAL
SHALL BE CHANGED ONLY WITH THE APPROVAL OF THE ENGINEER.
DIMENSIONS SHALL BE VERIFIED WITH THE ACTUAL EQUIPMENT PURCHASED.DIMENSIONS
ANCHORAGE HAVE BEEN DETERMINED USING SPECIFIC MANUFACTURERS EQUIPMENT.FINAL
DIMENSIONS OF EQUIPMENT OPENINGS, SUPPORTS, PADS, SLAB DEPRESSIONS, FOUNDATIONS &

APPROVAL.
DESIGN BUILDER. ALTERNATIVES TO THE DETAILS SHOWN MAY BE SUBJECT TO OWNER
DETAILS AND COORDINATION WITH OTHER DISCIPLINES ARE THE RESPONSIBILITY OF THE
EFFORTS AND ARE SUGGESTED STRUCTURAL DESIGN ONLY. FOUNDATION DESIGN, SIZING
THE DESIGN DEPICTED IN THIS SET OF DRAWINGS REPERESENTS PRELIMINARY ENGINEERING
SPECIFICATIONS AND THE ISSUED DRAWINGS.
GENERAL NOTES ARE TO BE READ IN CONJUNCTION WITH PROJECT TECHNICAL



PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
NOTES:
A
PART
B
PART
KEY PLAN
AND TRACK DRAWINGS.
VERIFY ALL DIMENSIONS WITH ARCHITECTURAL

CONCRETE STRENGTH fc = 5000 PSI.

ALL CAISSONS TO BE 3-0" DIAMETER.
3.
2.
1.
16 16 0 32
SCALE:"=1-0"
16 16 0 32
SCALE:"=1-0"
PILE LAYOUT PLAN
DECEMBER 2013
BT
JE
RG

ST-L03
93 1 / 16"=1-0"
LYTTONSVILLE YARD FACILITY
Y1 9+00
Y2 3+00
Y3 4+00
Y1 8+00
Y2 1+00 Y2 2+00
Y3 3+00 Y3 2+00
Y1 7+00
Y2 0+00
10-SHOP-B-17
10-SHOP-B-21
10-SHOP-B-6
10-SHOP-B-16
1 2 3 4 5 6 7 8 9 10 11 12 13 14
A
B
7.1
624-0"
24-0" 24-0" 24-0" 24-0" 24-0" 22-0" 22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0"
4-0"
6
0

-
0

"
4
8

-
1
1

"
11-0"
N
SCALE: " = 1-0"
PARTIAL PILE LAYOUT PLAN
CAISSON (TYP)
W24 (TYP)
FOOTING
FACE OF
A
-
A

T
H
I
S

S
H
E
E
T
M
A
T
C
H
L
I
N
E

S
E
E
ST-L18
A
C TRACK 1
L
CONC. WALL
FACE OF
ST-L20
A
2-6"
C
L
C
L
(TYP.)
OPENINGS
ELEVATOR PIT
S
E
E

D
W
G

N
0
.

S
T
-
L
0
4
M
A
T
C
H
L
I
N
E

Y2 7+00
Y3 8+00
Y1 13+00
Y2 6+00
Y3 7+00
Y1 12+00
Y2 5+00
Y3 6+00
Y1 11+00
Y2 4+00
Y3 5+00
Y1 10+00
10-SHOP-B-20
1-BR-LV-B-2
10-SHOP-B-7
10-SHOP-B-18
10-SHOP-B-3
10-SHOP-B-19
624-0"
11-0"
4-0"
22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0" 22-0" 22-0" 24-0" 24-0" 24-0"
4-0"
75.09
3-0"
15 16 17 18 19 20 21 22 23 24 25 26 27 15.1 23.1 N
SCALE: " = 1-0"
PARTIAL PILE LAYOUT PLAN
CAISSON (TYP)
W24 (TYP)
FOOTING
FACE OF
WALL
FACE OF CONC.
A
-
A

T
H
I
S

S
H
E
E
T
M
A
T
C
H
L
I
N
E

S
E
E
ST-L19
A
C TRACK 1 L
L C
L C
SEE ST1T01
BRIDGE ABUTMENT
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
281
285
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
0
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
16 16 0 32
SCALE:"=1-0"
16 16 0 32
SCALE:"=1-0"
RETAINING WALL GENERAL PLAN & ELEVATION
DECEMBER 2013
BT
JE
RG

ST-L04
94 1 / 16"=1-0"
LYTTONSVILLE YARD FACILITY
N
SCALE: " = 1-0"
PLAN
W
A
L
L

C
O
P
I
N
G
S
T
A
.

Y
1

4
+
2
9
.
5
8
B
E
G
I
N
N
I
N
G

O
F

W
A
L
L
S
E
E

D
W
G

N
O
.

S
T
-
L
0
5
M
A
T
C
H
L
I
N
E

-

S
T
A
.

6
+
6
8
.
1
8
A
B
A
10-SHOP-B-8
10-SHOP-B-15
Y1 4+00
Y1 5+00 Y1 6+00
SCALE: " = 1-0"
RETAINING WALL - ELEVATION (FROM BROOKVILLE ROAD)
DATUM EL. = 250.00
STA. Y1 4+29.58
BEGINNING OF WALL
T/RAIL
GRADE
EXISTING
S
E
E

D
W
G

N
O
.

S
T
-
L
0
6
M
A
T
C
H
L
I
N
E

-

S
T
A
.

6
+
6
8
.
1
8
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
285
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
2
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
0
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
M
A
T
C
H
L
I
N
E

S
E
E

D
W
G

N
O
.

S
T
-
L
0
4
M
A
T
C
H
L
I
N
E

A
-
A


T
H
I
S

S
H
E
E
T
M
A
T
C
H
L
I
N
E

A
-
A


T
H
I
S

S
H
E
E
T

SCALE: " = 1-0"
SCALE: " = 1-0"
PARTIAL PLAN
PARTIAL PLAN
ST-L06
A
ST-L06
A
12 12 0 24
SCALE:"=1-0"
RETAINING WALL GENERAL PLAN
BT
JE
RG

ST-L05
3/32" = 1-0"
LYTTONSVILLE YARD FACILITY
DECEMBER 2013























95


ST-L18
A
W
A
L
L

C
O
P
I
N
G
N
COPING (TYP.)
CAISSON BELOW
10-SHOP-B-17
FOOTING
FACE OF
Y1 9+00 Y1 10+00 Y1 8+00
Y1 7+00
1607+00
1606+00
1605+00
10-SHOP-B-7
10-SHOP-B-16
10-SHOP-B-1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 7.1
ST-L19
A
W
A
L
L

C
O
P
I
N
G
N
FOOTING
FACE OF Y1 10+00 Y1 12+00 Y1 11+00
Y1 13+00
1611+00
1610+00
1609+00
1608+00
10-SHOP-B-20
10-SHOP-B-3
10-SHOP-B-18
10-SHOP-B-7
10-SHOP-B-19
COPING (TYP.)
CAISSON BELOW
15 16 17 18 19 20 21 22 23 24 25 26 27 15.1 23.1
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
S
T
L
A
7
5
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
0
6
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
16 16 0 32
SCALE:"=1-0"
16 16 0 32
SCALE:"=1-0"
RETAINING WALL ELEVATION
DECEMBER 2013
BT
JE
RG

ST-L06
96 1 / 16"=1-0"
LYTTONSVILLE YARD FACILITY
15 16 17 18 19 20 21 22 23 24 25 26 27 15.1 23.1
624-0"
11-0"
4-0"
22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0" 22-0" 22-0" 24-0" 24-0" 24-0"
4-0"
DATUM EL. = 250.00
A
SCALE: " = 1-0"
EL. = 280.00
T/RAIL
RETAINING WALL - ELEVATION (FROM BROOKVILLE ROAD)
ST-L06
EL. = 305.00
T/SLAB
EL. = VARIES
T/SIDEWALK
EL. = 305.50
T/SLAB
T
H
I
S

S
H
E
E
T
M
A
T
C
H
L
I
N
E

A
-
A

S
E
E
GRADE
EXISTING
REF: ST-L05
LyttDeckWall
624-0"
24-0" 24-0" 24-0" 24-0" 24-0" 22-0" 22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0"
4-0"
11-0"
1 2 3 4 5 6 7 8 9 10 11 12 13 14 7.1
DATUM EL. = 250.00
A
SCALE: " = 1-0" ST-L06
EL. = 305.00
T/SLAB
EL. = VARIES
T/SIDEWALK
T
H
I
S

S
H
E
E
T
M
A
T
C
H
L
I
N
E

A
-
A


S
E
E
RETAINING WALL - ELEVATION (FROM BROOKVILLE ROAD)
EXISTING GRADE
EL. = 280.00
T/RAIL
D
W
G

N
O
.

S
T
-
L
0
4
M
A
T
C
H
L
I
N
E

S
E
E
REF: ST-L05
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
NOTES:
3.
2.
1.
A
PART
B
PART
KEY PLAN
AND TRACK DRAWINGS.
VERIFY ALL DIMENSIONS WITH ARCHITECTURAL

CONCRETE STRENGTH fc = 5000 PSI.

3-0" DIAMETER.
ALL ROUND CONCRETE COLUMNS TO BE
FOUNDATION PLAN - SHEET 1 OF 3
DECEMBER 2013
BT
JE
RG

ST-L07
97 1 / 16"=1-0"
LYTTONSVILLE YARD FACILITY
CLTRACK 9
16 16 0 32
SCALE:"=1-0"
10-SHOP-B-11
10-SHOP-B-10
10-SHOP-B-23
10-SHOP-B-24
10-SHOP-B-25
10-SHOP-B-21 10-SHOP-B-6
10-SHOP-B-17
10-SHOP-B-16
10-SHOP-B-1
1 2 3 4 5 6 7 8 9 10 11 12 13 14
A
B
C
D
7.1
1
6
8

-
5

"
624-0"
24-0" 24-0" 24-0" 24-0" 24-0" 22-0" 22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0"
4-0"
5
9

-
5

"
6
0

-
0

"
4
8

-
1
1

"
11-0"
SCALE: " = 1-0"
N
CL
CL
CL
CL
CL
CL
CL
TRACK 1
TRACK 2
TRACK 4
TRACK 5
TRACK 6
TRACK 7
TRACK 8
NO. ST-L09
MATCHLINE SEE DWG.
1
0

-
0
"
2
0

-
3

"
E
CLTRACK 3
N
O
.

S
T
-
L
0
8
M
A
T
C
H
L
I
N
E

S
E
E

D
W
G
.
ST-L18
A
PARTIAL FOUNDATION PLAN
ST-L17
A
PIT
MAINTENANCE
(TYP)
DRILLED SHAFT
ST-L26
A
ST-L20
A
(TYP)
COLUMN
CONCRETE
(TYP)
PILE CAP
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
2
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
0
7
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
NOTES:
3.
2.
1.
A
PART
B
PART
KEY PLAN
AND TRACK DRAWINGS.
VERIFY ALL DIMENSIONS WITH ARCHITECTURAL

CONCRETE STRENGTH fc = 5000 PSI.

3-0" DIAMETER.
ALL ROUND CONCRETE COLUMNS TO BE
FOUNDATION PLAN - SHEET 2 OF 3
DECEMBER 2013
BT
JE
RG

ST-L08
98 1 / 16"=1-0"
LYTTONSVILLE YARD FACILITY
16 16 0 32
SCALE:"=1-0"
SEE ST1T01
BRIDGE ABUTMENT
10-SHOP-B-28
10-SHOP-B-5
10-SHOP-B-27
1-BR-LV-B-2
10-SHOP-B-20
10-SHOP-B-19
10-SHOP-B-3
10-SHOP-B-18
10-SHOP-B-7
10-SHOP-B-22
10-SHOP-B-26
BLP-2
15 16 17 18 19 20 21 22 23 24 25 26 27 15.1 23.1
624-0"
11-0"
4-0"
22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0" 22-0" 22-0" 24-0" 24-0" 24-0"
4-0"
A
B
C
D
1
8
3

-
5
"
5
9

-
5

"
6
0

-
0

"
4
8

-
1
1

"
75.09
1
4

-
1
1

"
3-0"
SCALE: " = 1-0"
N
PARTIAL COLUMN LAYOUT PLAN
CL
CL
CL
CL
CL
CL
CL
CLTRACK 1
TRACK 2
TRACK 4
TRACK 5
TRACK 6
TRACK 7
TRACK 8
TRACK 9
CLTRACK 3
ST-L19
A
ST-L17
A
N
O
.

S
T
-
L
0
7
M
A
T
C
H
L
I
N
E

S
E
E

D
W
G
.
(TYP)
DRILLED SHAFT
(TYP.)
COLUMN
CONCRETE
(TYP.)
PILE CAP
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
0
8
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
0
9
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
NOTES:
N
A
PART
B
PART
KEY PLAN
AND TRACK DRAWINGS.
VERIFY ALL DIMENSIONS WITH ARCHITECTURAL 1.
FOUNDATION PLAN - SHEET 3 OF 3
DECEMBER 2013
BT
JE
RG

ST-L09
99 1 / 8"=1-0"
LYTTONSVILLE YARD FACILITY
8 8 0 16
SCALE:"=1-0"
E
F
F.1
31-9" 25-8" 25-8" 23-3" 25-8"
4-4"
15-10" 15-4"
4

-
0
"
2
2

-
2

"
7.7 8.9 10.1 11.1 12.2 13.1 14 14.2 15 15.1 13 13.3
6-7"
4-0"
SCALE: " = 1-0"
8

-
5
"
NO. ST-L07
MATCHLINE SEE DWG.
TRACK 10 CL
FOUNDATION PLAN
APRON SLAB
APRON SLAB
(TYP)
FOUNDATION WALL
(TYP)
SPREAD FOOTING
(STAIR SUPPORT)
CAISSON
(STAIR SUPPORTS)
CONC. WALL
(TYP)
FOOTING
1
0

-
3
"
(TYP)
FOOTING
TRENCH DRAIN
(TYP)
W14
A
ST-L22
B
ST-L22
A
ST-L23
10-SHOP-B-4
10-SHOP-B-24
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
1
0
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
NOTES:
6.
5.
4.
3.
2.
1.
DRAIN (RD) TO BE MINIMUM 1%.
SLOPE AT ANY POINT ON THE DECK TO THE ROOF
THE ADMIN. BUILDING.
SEE DESIGN CRITERIA FOR DESIGN LIVE LOAD OF
DESIGN LIVE LOAD = 40 PSF FOR THE DECK AREA.

fc = 5000 PSI.
COMPRESSIVE STRENGTH OF CONCRETE

CONCRETE.
ALL TRANSVERSE BEAMS TO BE REINFORCED
CONCRETE.
ALL LONGITUDINAL BEAMS TO BE POST TENSIONED
SLAB.
FLOOR TO BE 12" THICK REINFORCED CONCRETE
A
PART
B
PART
KEY PLAN
FRAMING AND SLAB PLAN - SHEET 1 OF 2
DECEMBER 2013
BT
JE
RG

ST-L10
100 1 / 16"=1-0"
LYTTONSVILLE YARD FACILITY
16 16 0 32
SCALE:"=1-0"
1 2 3 4 5 6 7 8 9 10 11 12 13 14
A
B
C
D
7.1
1
6
8

-
5

"
624-0"
24-0" 24-0" 24-0" 24-0" 24-0" 22-0" 22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0"
4-0"
5
9

-
5

"
6
0

-
0

"
4
8

-
1
1

"
11-0"
SCALE: " = 1-0"
SLOPE SLOPE
RD
S
L
O
P
E
S
L
O
P
E
N
RD RD RD
RD RD RD
SLOPE
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
SLOPE SLOPE
SLOPE SLOPE SLOPE
SLOPE SLOPE SLOPE SLOPE
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
EXP. JOINT EDGE OF SLAB
EDGE OF SLAB
ELEVATOR OPENINGS
(TYP)
BEAM
CONC.
(TYP)
COLUMN
PARTIAL PLAN - DECK LEVEL (ELEV. 350.00 LOW POINT)
ST-L18
A
ST-L17
A
H.P H.P H.P
H.P
SLOPE
N
O
.

S
T
-
L
1
1
M
A
T
C
H
L
I
N
E

S
E
E

D
W
G
.
ST-L26
B
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
1
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
NOTES:
6.
5.
4.
3.
2.
1.
DRAIN (RD) TO BE MINIMUM 1%.
SLOPE AT ANY POINT ON THE DECK TO THE ROOF
THE ADMIN. BUILDING.
SEE DESIGN CRITERIA FOR DESIGN LIVE LOAD OF
DESIGN LIVE LOAD = 40 PSF FOR THE DECK AREA.

fc = 5000 PSI.
COMPRESSIVE STRENGTH OF CONCRETE

CONCRETE.
ALL TRANSVERSE BEAMS TO BE REINFORCED
CONCRETE.
ALL LONGITUDINAL BEAMS TO BE POST TENSIONED
SLAB.
FLOOR TO BE 12" THICK REINFORCED CONCRETE
A
PART
B
PART
KEY PLAN
FRAMING AND SLAB PLAN - SHEET 2 OF 2
DECEMBER 2013
BT
JE
RG

ST-L11
101 1 / 16"=1-0"
LYTTONSVILLE YARD FACILITY
16 16 0 32
SCALE:"=1-0"
W/25 FOOT POLE (TYPICAL)
TYPE P PARKING LOT LIGHTING
15 16 17 18 19 20 21 22 23 24 25 26 27 15.1 23.1
624-0"
11-0"
4-0"
22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0" 22-0" 22-0" 24-0" 24-0" 24-0"
4-0"
A
B
C
D
1
8
3

-
5
"
5
9

-
5

"
6
0

-
0

"
4
8

-
1
1

"
75.09
1
4

-
1
1

"
3-0"
SCALE: " = 1-0"
PARTIAL PLAN - DECK LEVEL
RD RD
RD RD
EXP. JOINT EXP. JOINT EDGE OF SLAB
EDGE OF SLAB
N
S
L
O
P
E
SLOPE SLOPE SLOPE SLOPE SLOPE
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
S
L
O
P
E
SLOPE SLOPE SLOPE SLOPE SLOPE
N
O
.

S
T
-
L
1
0
M
A
T
C
H
L
I
N
E

S
E
E

D
W
G
.
(TYP)
BEAM
CONC.
ELEVATOR OPENING
STAIR OPENING
305.00
ELEV.
T/SLAB
305.50
ELEV.
T/SLAB
(TYP)
COLUMN
(TYP)
COLUMN
OUTLINE
BUILDING
(TYP)
BEAM
CONC.
WALL
CONC.
ST-L17
A
ST-L19
A
SLAB
EDGE OF
S
L
O
P
E
SEE ST1T01
SIDE WALK ABOVE
ST-L26
B
ST-L26
B
S
L
O
P
E
R
A
M
P

D
O
W
N
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
1
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
LEGEND:
OPEN WEB STEEL JOIST
NOTES:
3.
2.
1.
A
PART
B
PART
KEY PLAN
fc = 3500 PSI.
CONCRETE TOPPING ON METAL DECK
FLOOR DECK TO BE COMPOSITE.
DRAWINGS.
VERIFY ALL DIMENSIONS WITH ARCHITECTURAL
N N
COLUMN LAYOUT & 2ND FLOOR FRAMING PLAN
DECEMBER 2013
BT
JE
RG

ST-L12
102 1/16" = 1-0"
LYTTONSVILLE YARD FACILITY
16 16 0 32
SCALE:"=1-0"
24 25 26 27
A
B
C
D
AA
A.3
A.4
B.8
C.8
B.6
A.8
B.5
24-0" 24-0" 24-0"
1
8
2

-
2

"
5
9

-
5

"
6
0

-
0

"
4
8

-
1
1

"
4
0

-
7

"
8

-
9
"
1
7

-
4
"
3
1

-
1
1

"
2
1

-
3
"
1
6

-
1
0

"
1
3

-
9

"
72-0"
1
8

-
1
0

"
2

-
9
"
8

-
0

"
2

-
0
"
SCALE: " = 1-0"
ELEVATOR OPENING
STAIR OPENING
EDGE OF SLAB
2ND FLOOR FRAMING PLAN
STAIR OPENING
W12
W
2
4
W
1
2
W12
W12
W12
W12 W12
W12 W12 W12
W12 W12 W12
W12 W12 W12
W12
W12
W12
W12 W12
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
2
4
W
2
4
W
2
4
W
1
8
W
2
4
W
2
4
W
1
8
W
2
4
W
2
4
W
2
4
W
1
8
W
2
4
W
2
4
W
2
4
W
1
2
W
2
4
W
2
4
W
2
4
ST-L17
A
ST-L27
B
ST-L27
A
W12 (TYP)
16 16 0 32
SCALE:"=1-0"
24 25 26 27
A
B
C
D
AA
A.3
A.4
B.8
C.8
B.6
A.8
B.5
24-0" 24-0" 24-0"
1
8
2

-
2

"
5
9

-
5

"
6
0

-
0

"
4
8

-
1
1

"
4
0

-
7

"
8

-
9
"
1
7

-
4
"
3
1

-
1
1

"
2
1

-
3
"
1
6

-
1
0

"
1
3

-
9

"
72-0"
1
8

-
1
0

"
2

-
9
"
8

-
0

"
2

-
0
"
SCALE: " = 1-0"
EDGE OF SLAB
W12 (TYP)
ELEVATOR OPENING
STAIR OPENING
305.50
ELEV.
T/SLAB
DECK LEVEL - COLUMN LAYOUT (ELEV. 350.00)
ST-L17
A
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
1
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
KEY PLAN
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
METAL ROOF
METAL ROOF
METAL ROOF
A
ST-L17
A
B
C
D
AA
A.3
A.4
B.8
C.8
B.6
A.8
24 25 26 27 24 25 27
W12 W12
W12
W12 W12 W12
W12
W12 W12 W12
W12 W12 W12
W12 W12
W12 W12
W
2
4
W
1
8
W
1
2
W
1
2
W
1
2
W
1
2
W
1
8
W
1
8
W
1
8
W
1
8
W
1
8
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
4
0

-
7

"
1
8

-
1
0

"
2
1

-
3
"
1
6

-
1
0

"
1
3

-
9

"
24-0" 24-0" 24-0"

2

-
9
"
B.5
W
1
8
W
1
8
W
1
2
W
1
2
W
1
2
W12
W12
W
1
8
W
2
4
W
2
4
8

-
9
"
1
7

-
4
"
8

-
0

"
2

-
0
"
3
1

-
1
1

"
T-1042-0220
PRELIMINARY ENGINEERING
443
N
16 16 0 32
SCALE: 1/16"=1-0"
SCALE: " = 1-0"
OFFICE ROOF FRAMING PLAN
OPEN WEB STEEL JOIST
LEGEND:
NOTE:
1-VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
OFFICE ROOF FRAMING PLAN
DECEMBER 2013
BT
JE
RG

ST-L13
103 1/16"=1-0"
LYTTONSVILLE YARD FACILITY
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
1
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
LEGEND:
OPEN WEB STEEL JOIST
MOMENT CONNECTION
NOTES:
N
A
PART
B
PART
METAL.
THE ROOF DECK SHALL CONSIST OF GALVANIZED
DRAWINGS.
VERIFY ALL DIMENSIONS WITH ARCHITECTURAL
2.
1.
KEY PLAN
WASH BUILDING ROOF FRAMING PLAN
DECEMBER 2013
BT
JE
RG

ST-L14
104 1 / 8"=1-0"
LYTTONSVILLE YARD FACILITY
8 8 0 16
SCALE:"=1-0"
SEE DWG NO. ST-L15
E
F
F.1
31-9" 25-8" 25-8" 23-3" 25-8"
4-4"
15-10" 15-4"
4

-
0
"
2
2

-
2

"
7.7 8.9 10.1 11.1 12.2 13.1 14 14.2 15 15.1 13 13.3
6-7"
4-0"
SCALE: " = 1-0"
ROOF FRAMING PLAN
FACE OF BUILDING
W18
W18 W18 W18
W18
W18
W18 W18 W18 W18
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
W
1
2
EDGE SEE DWG NO. ST-L10
PARKING GARAGE SLAB
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
1
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
NOTES:
N
A
PART
B
PART
KEY PLAN
AND TRACK DRAWINGS.
VERIFY ALL DIMENSIONS WITH ARCHITECTURAL 1.
4 4 0 8
SCALE:"=1-0"
STAIR S4 FRAMING PLAN
DECEMBER 2013
BT
JE
RG

ST-L15
105 1 / 4"=1-0"
LYTTONSVILLE YARD FACILITY
H
S
S

3
X
3
SCALE: " = 1-0"
TRACK 10
HSS 12X3
HSS 12X3
HSS 12X3
HSS 12X3
HSS 3X3
HSS 3X3
H
S
S

1
2
X
3
H
S
S

1
2
X
3
H
S
S

1
2
X
3
H
S
S

1
2
X
3
PIER CAP
CONC. WALL
(TYP.)
HSS 6X6
EXP. JOINT
CORBEL
STAIR S4 FRAMING PLAN
13 13.3
15-4" 6-7" 15-10" 8-1"
5-11"
4

-
4

"
1
4

-
1
0

"
4-4" 3-6" 17-7"
4-0"
13.1 14 14.2 15 15.1

H
S
S

3
X
3
H
S
S

3
X
3
HSS 3X3
HSS 3X3
H
S
S

3
X
3
PIER CAP
D
18-6"
2

-
3
"
9

-
4

"
HSS 3X3
DWG. N0. STL10
SLAB EDGE SEE
COL. TYP.
CANOPY SUPPORT
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
1
6
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
A
PART
B
PART
KEY PLAN
6 6 0 12
SCALE:"=1-0"
BRACE ELEVATIONS
DECEMBER 2013
BT
JE
RG

ST-L16
106 3 / 16"=1-0"
LYTTONSVILLE YARD FACILITY
W12X W12X
W
1
2
X
24-0" 24-0"
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
W
1
2
X
24-0" 24-0" 24-0"
26-1" 13-9" 33-11" 8-9"
ROOF
2ND FLOOR
1ST FLOOR
2ND FLOOR
ROOF
1ST FLOOR
2ND FLOOR
ROOF
1ST FLOOR
2ND FLOOR
ROOF
1ST FLOOR
2ND FLOOR
ROOF
1ST FLOOR
2ND FLOOR
ROOF
1ST FLOOR
ROOF
2ND FLOOR
1ST FLOOR
AT COLUMN LINE "AA"
AT COLUMN LINE "24" AT COLUMN LINE "25" AT COLUMN LINE "27"
AT COLUMN LINE "A" AT COLUMN LINE "C"
24
B.6 B.6
25 26 24 25 26 27 24 25
C AA A B C B.8
AT COLUMN LINE "C"
AT COLUMN LINE "25"
W
1
2
X
W
1
2
X
24 25
AT COLUMN LINE "C.8"
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
1
7
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
A
PART
B
PART
KEY PLAN
16 16 0 32
SCALE:"=1-0"
16 16 0 32
SCALE:"=1-0"
LONGITUDINAL SECTION ALONG COLUMN "C"
DECEMBER 2013
BT
JE
RG

ST-L17
107 1 / 16"=1-0"
LYTTONSVILLE YARD FACILITY
624-0"
24-0" 24-0" 24-0" 24-0" 24-0" 22-0" 22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0"
4-0"
11-0"
1 2 3 4 5 6 7 8 9 10 11 12 13 14 7.1
DATUM EL. = 250.00
A
SCALE: " = 1-0"
LONGITUDINAL SECTION AT COL. "C"
ST-L17
REF:
A
-
A

T
H
I
S

S
H
E
E
T
M
A
T
C
H
L
I
N
E

S
E
E
EL. = 280.00
T/RAIL
L.P L.P L.P H.P H.P H.P H.P
EL. = 305.00
T/SLAB
ST-L08
ST-L07
ST-L12
ST-L10
EL. = 276.00
T/DRILLED SHAFT
LyttDeckWall
15 16 17 18 19 20 21 22 23 24 25 26 27 15.1 23.1
624-0"
11-0"
4-0"
22-0" 24-0" 24-0" 24-0" 24-0" 24-0" 24-0" 22-0" 22-0" 24-0" 24-0" 24-0"
4-0"
EL. = 280.00
T/RAIL
DATUM EL. = 250.00
A
SCALE: " = 1-0"
LONGITUDINAL SECTION AT COL. "C"
ST-L17
REF:
ST-L13
ST-L12
ST-L11
ST-L08
A
-
A

T
H
I
S

S
H
E
E
T
M
A
T
C
H
L
I
N
E

S
E
E
L.P H.P H.P L.P H.P
EL. = 305.00
T/SLAB
EL. = 305.00
PLACE BRIDGE
LYTTONSVILLE
EL. = 276.00
T/PILE CAP
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
1
8
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8 8 0 16
SCALE:"=1-0"
CROSS SECTION OF PARKING GARAGE
DECEMBER 2013
BT
JE
RG

ST-L18
108 1 / 8"=1-0"
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
Y10 Y9 Y8 Y7 Y6 Y5 Y4 Y3 Y2 Y1
A B C D
DATUM EL. = 250.00
A
ST-L18 SCALE: " = 1-0"
REF:
SECTION AT STA. Y9 16+75
ST-L10
ST-L07
ST-L05
ST-L03
EL. 280.00
T/RAIL
T/SIDEWALK
EL. 305.00
T/SLAB
PARAPET
16-5" 48-11" 60-0" 59-5"
21-0" 18-6" 18-6" 18-6" 18-6" 18-6"
2
0

-
0
"
16-6" 15-11" 14-6" 8-6" 14-6" 8-6" 14-0" 9-0"
EL. 276.00
T/DRILLED SHAFT
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
1
9
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8 8 0 16
SCALE:"=1-0"
CROSS SECTION OF PARKING GARAGE
DECEMBER 2013
BT
JE
RG

ST-L19
109 1/8" = 1-0"
LYTTONSVILLE YARD FACILITY
443
Y10 Y9 Y8 Y7 Y6 Y5 Y4 Y3 Y2 Y1
A B C D
A
DATUM EL. = 250.00
ST-L19 SCALE: " = 1-0"
REF:
ST-L11
ST-L08
ST-L05
ST-L03
SECTION AT STA. Y9 19+10
18-6" 18-6" 18-6" 14-6" 8-6" 18-6" 18-6"
59-5" 60-0" 48-11" 16-5"
2
0

-
0
"
1
9

-
1
"
16-6" 15-11" 14-6" 8-6" 14-0"
EL. 305.00
T/SLAB BEYOND
EL. 280.00
T/RAIL
SLAB
ROOF
S.O.G.
RAMP
VEHICLE
HP
LP
EL. 305.00
T/SLAB
PARAPET
EL. 276.00
T/DRILLED SHAFT
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
2
0
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
2 2 0 4
SCALE:"=1-0"
2 2 0 4
SCALE:"=1-0"
2 2 0 4
SCALE:"=1-0"
2 2 0 4
SCALE:"=1-0"
SECTIONS AND DETAILS
DECEMBER 2013
BT
JE
RG

ST-L20
110 AS SHOWN
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
CL
SLOPE SLOPE
2
DETAILS (TYP.)
SEE ARCH. DWG. FOR
SLEEVE FOR HANDRAIL
6" (TYP.)
2

-
0
"
2-5" 2-5"
ELEV 0.00
T/SLAB
SCALE:
REF:
SECTION A
9-0" 4-0"
1
ST-L21
ST-L20 " = 1-0"
ST-L03
ST-L07
4-0"
TRACK 1 AND MAINTENANCE PIT
ELEV -5.00
ST-L20
SCALE:
REF: ST-L20
2
" = 1-0"
DETAIL AT TRENCH DRAIN
FOR TRENCH DRAIN DETAIL.
SEE PLUMBING DRAWING
TRENCH DRAIN
10 MIL VAPOR BARRIER
6" GRANULAR FILL
ST-L20
SCALE:
REF: ST-L20
1
" = 1-0"
SUMP PIT REINFORCEMENT
2-0"
2

-
0
"
2-5"
2-5"
TYP.
TYP.
1-0"
TYP.
ST-L20 SCALE:
REF: ST-L20
B
" = 1-0"
TYPICAL THICKENED
SLAB AT CMU PARTITION
#5 @ 24" O.C.
WALL
8" MASONRY
3 #5 CONT.
1
1
WALL AND FOOTING
GRAVEL CONCRETE
REBAR WITH PEA
CELL CONTAINING
#5 @ 24" O.C. FILL
2

-
0
"
2-0"
ST-L20
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
2
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
1 1 0 2
SCALE: 1"=1-0"
1 1 0 2
SCALE: 1"=1-0"
1 1 0 2
SCALE: 1"=1-0"
1 1 0 2
SCALE: 1"=1-0"
1 1 0 2
SCALE: 1"=1-0"
1 1 0 2
SCALE: 1"=1-0"
RAIL PEDESTAL DETAIL
DECEMBER 2013
BT
JE
RG

ST-L21
111 AS SHOWN
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
1-2" 1-2"
TYP.
SEE PLAN
FL ELEV
SEE PLAN
T/R ELEV
5" 5" 5" 5"
ST-L21
A
@1.12#
1"xCS
TWO FOR EACH SIDE, TYP.
REVERSABLE FILLERS,
SINGLE RAIL CLAMP WITH
STRAY CURRENT
BARS TO MAINTAIN
TO LONGITUDINAL
SHALL BE BONDED
PEDESTAL FRAMES
(TYP.)
4-0"
G
R
O
U
T
M
I
N
.
1

-
6
"
1

"


SUPPORT FRAME
ANCHOR BOLTS
SCALE:
REF: ST-L20
1" = 1-0" ST-L21
1 TYPICAL RAIL POST DETAIL
OF RAIL POST (TYP.)
ST-L21
C
1-2"x1-4"
(TYP.)
W12 POST
1-6"x1-4"
BASE
DRAIN IN THE PIT.
CONFLICT WITH TRENCH
NECESSARY TO AVOID
CUT 1"xCS WHERE
BOLTS AT EACH BRACED POST
PROVIDE (4) A307 ANCHOR
G
R
O
U
T
(TYP.)
M
I
N
.
TYP.
4-0"
5" 5" 5" 5"
136 RE RAIL
1-2" 7"
1

-
6
"
1-2" 7"
ST-L21
B
SEE PLAN
T/R ELEV
OF RAIL POST OF RAIL POST
SEE PLAN
FL ELEV
BRACING EVERY 80.
NOTE: PROVIDE LATERAL
SUPPORT FRAME
ANCHOR BOLTS
1

"


@1.12#
1"xCS
SCALE:
REF:
1" = 1-0" ST-L21
2
TYPICAL RAIL POST
CROSS BRACING DETAIL
SCALE:
REF: ST-L21
1" = 1-0"
TYPICAL RAIL POST
WITH WASHER
PROVIDE BOLT
BRACING ANGLE
(TYP.)
GUSSET
1-2"x1-4"
(TYP.)
W12 POST
EACH BRACED POST
ANCHOR BOLTS AT
PROVIDE (6) A307
SCALE:
REF:
SECTION
ST-L21
A
GROUT HOLE
1" DIA.
TRACK
BASE
OF POST AND
1

-
4
"
1
0
"
3
"
3
"
2

-
5

"2" 7" 7" 2"


1-6"
5
"
1" = 1-0"
W12
BASE
1-6"x1-4"
ST-L21 SCALE:
REF:
SECTION
ST-L21
B
TYP.
RAIL POST
POST
RAIL
2-1"
7" 7" 7" 2" 2"
1

-
4
"
5
"
5
"
1" = 1-0" ST-L21
TYP. BRACING ANGLE
2-" BOLTS
L3x3xWITH
ANCHOR BOLTS
HOLES FOR
W12
AS REQUIRED)
(CLIP CORNER
GUSSET
ST-L21
C
SCALE:
REF:
TOP VIEW
RAIL BASE
OF POST AND RAIL
3"
2
"
2
"
1

-
2
"
1
0
"
4" 7"
1-4"
4"
5"
1" = 1-0"
FOR BOLTS (TYP.)
SLOTTED HOLES
1"x"
ST-L21
ST-L20
1
SCALE:
REF:
TYPICAL RAIL POST DETAIL
RAIL
SEE PLAN
T/R ELEV
OF POST AND RAIL
PIT (SYM.)
TRACK AND
9"
4"
7"
2-5"
2-4"
1" = 1-0"
CONDUCTIVE RAIL SEAT
EXTRUDED RUBBER NON-
3 PIECES, 1-2"x 9"
(TYP.)
W12 POST
CAP 1-2"x1-4"
ST-L21
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
2
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SECTIONS AND DETAILS
DECEMBER 2013
BT
JE
RG

ST-L22
112 NONE
LYTTONSVILLE YARD FACILITY
ISOLATION JOINT
SLAB ON GRADE
6
"

M
I
N
.
SCALE:
REF:
A
ST-L09
NTS
TYPICAL EXTERIOR WALL DETAILS
ST-L22
SEE ARCH. DWG
SCALE:
REF:
B
ST-L09
TYPICAL EXTERIOR COLUMN DETAILS
CONCRETE PIER
NTS
BRACING
STEEL COLUMN
BASE PLATE
ISOLATION JOINT
BENT PLATE
ST-L22
SEE ARCH. DWG
C
ST-L22
BASE PLATE DETAIL
B
/
2
B
/
2
D
D
A/2 A/2
C C
C
L COLUMN
C
L COLUMN
(TYP UNO)
SCALE:
REF:
NTS
C
ST-L22
A
B
ST-L22
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
2
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
4 4 0 8
SCALE:"=1-0"
4 4 0 8
SCALE:"=1-0"
1 1 0 2
SCALE: 1"=1-0"
4 4 0 8
SCALE:"=1-0"
DETAILS
DECEMBER 2013
BT
JE
RG

ST-L23
113 AS SHOWN
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
SCALE:
REF:
SECTION
" = 1-0"
B
SLOPE
FOR RAILS
TRACK
1-10"
9"x1-2" 1-2"
4-3" 4-3"
3
"

C
L
.
SLOPE
1-10"
1
ST-L23
ST-L23
ST-L23
SCALE:
REF:
SECTION
ST-L23
" = 1-0"
C
4-8"
8-6"
BALLASTED TRACK WITH TRANSITION SLAB
TRACK
BALLAST
1

-
1
0

"
1

-
2

"
6

"
8-3" CONCRETE TIE
ST-L23
ST-L09
" = 1-0"
A
SCALE:
REF:
TYPICAL TRANSITION SLAB DETAIL
8
"

S
U
B
-
B
A
L
L
A
S
T
9
"
2

-
2
"
1-0"
B C
3

-
2
"
2

-
2
"
JOINT FILLER
BUILDING
FACE OF
SUBGRADE
RAIL
BALLAST
" EXP.
8"
ELEV 0.00
FOR TRENCH DRAIN DETAIL
SEE PLUMBING DRAWING
APRON SLAB APPROACH SLAB
ST-L23 ST-L23
ST-L23
ST-L23
1
1" = 1-0"
T/SLAB BEYOND
9
"
T/R EL. = 0.00
T/RAIL
ELEV 0.00
ST-L23 SCALE:
REF:
DETAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
2
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
TYPICAL DETAILS
DECEMBER 2013
BT
JE
RG

ST-L24
114 NONE
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
SQUARE COLUMNS
RECTANGULAR COLUMNS
DETAIL 5
4 BARS 8 BARS 12 BARS
4 BARS 6 BARS 8 BARS
COLUMN TIES - SIZE & SPACING
4.
3.
2.
1.
SCALE: NTS
TIES (TYP.)
1 1/2" CL. TO
1 1/2" CL. TO
TIES (TYP.)
#4 TIES
6
"
M
IN
.
SUPPORT BAR.
FARTHER THAN 6" CLEAR ON EACH SIDE ALONG TIE FROM SUCH A LATERAL
SUPPORT PROVIDED BY THE CORNER OF A TIE AND NO BAR SHALL BE
HOWEVER, EVERY CORNER & ALTERNATE VERT. BAR SHALL HAVE LATERAL
RECOMMENDED COLUMN TIE DETAILS ARE SHOWN ON THIS DRAWING.
PROVIDE ADDITIONAL TIES AS SHOWN ON COLUMN DETAIL
c. 16 VERTICAL BAR DIAMETERS
b. 48 TIE BAR DIAMETERS
a. LEAST COLUMN DIMENSION
COLUMN TIE VERTICAL SPACING SHALL NOT EXCEED:
SMALLER & #4 BARS FOR #11.
ALL COLUMN TIES SHALL BE #3 BARS FOR VERT. REINF. OF # 10 OR
443
T-1042-0220
PRELIMINARY ENGINEERING
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
2
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
TYPICAL DETAILS
DECEMBER 2013
BT
JE
RG

ST-L25
115 NONE
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
TOP BARS F.L.
BOT. BARS
SEE SCHEDULE (TYP.)
COLUMN
TIES
STEEL COL.
L C
(
T
Y
P
.)
2
"

C
L
R
.
60-0"
1
SCALE:

TYPICAL POST - TENSION BEAM

4 #4 4 #5
4 #4
6
"
S
E
E

S
C
H
E
D
U
L
E3"
(TYP.)
N.T.S.
NOTE: FOR INFORMATION NOT SHOWN, SEE DETAIL BELOW.
3" 3"
ST-L25
3" 6"
TOP BARS F.L. STD. HOOK
INTO CANT. BEAM
OF ADJACENT BEAM
TOP & BOT. BARS
EXTEND AND HOOK
WHERE OCCURS
CANTILER BEAM
SEE SCHEDULE
COLUMN
BOT. BARS
COL.
BARS
OR PROVIDE CONT.
CLASS B SPLICE
CL
WHEN D> 36" U.N.O.
#4 @ 12" O.C. E.F.
TYPICAL BEAM ELEVATION
SCALE:

COL. CL
BOT. BARS
STIRRUP SPACING SEE SCHEDULE
L1 = 24-0" L2
D
3-0"
(MIN.) (TYP.)
2
N.T.S.
3" 3"
ST-L25
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
2
6
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
TYPICAL DETAILS
DECEMBER 2013
BT
JE
RG

ST-L26
116 NONE
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
SEE SCHEDULE
COLUMN
ROOF SLAB
3
0

D
IA
.
30 DIA.
3
"
COL. REINF.
DOWELS TO MATCH

1 1/2" TO TIES
GRADE (TYP.)
FINISHED
TYPICAL COLUMN
SCALE:

S
L
A
B
T
H
IC
K
N
E
S
S
A
REF. ST-L07
ST-L26 NTS
BOT. BARS
TOP BARS
(TYP.)
CONC. BEAM
TEMP. BARS
1
-
0
"
6" MIN.
SECTION PERPENDICULAR TO SLAB SPAN
S
L
A
B

T
H
IC
K
N
E
S
S
TOP BARS
TEMP. BARS BOT. BARS
1
SECTION PARALLEL TO SLAB SPAN
CONC. BEAM
NTS SCALE:

TYPICAL ONE WAY SLAB DETAILS
ST-L26
3
-
0
"
1
2
"
SLOPE DOWN
SEE ARCH. DWG.
EXP. JT ASSEMBLY
B
SLOPE DOWN

WIDTH
GAP
EXP. JT.

(TYP.)
CONC. SLAB
(TYP.)
CONC. BEAM
L C L C
SCALE:

EXPANSION JOINT DETAIL
ST-L11
REF. ST-L10
ST-L26 NTS
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
S
t
r
u
c
t
u
r
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
S
T
L
A
2
7
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
TYPICAL DETAILS
DECEMBER 2013
BT
JE
RG

ST-L27
117 NONE
LYTTONSVILLE YARD FACILITY
6" U.N.O.
FLUTE
PUDDLE WELD PER
PER PLAN
STEEL REINFORCEMENT
PER PLAN
METAL DECK
CONCRETE COVER TOPPING
POUR STOP
POUR STOP & BEAM
WELD BETWEEN
PLAN
BEAM PER
"
@ 12" O.C.
"
@ 12" O.C. POUR STOP & BEAM
WELD BETWEEN
SCALE:
REF:
A
ST-L12
METAL DECK SUPPORT
TYPICAL STEEL BEAM
NTS ST-L27 SCALE:
REF:
B
ST-L12
OF BEAM PROVIDE 2" EXTENSION
FOR JOISTS BEARING ON ONE SIDE
STEEL JOIST
FOR SIZE
BEAM RE: PLAN
TYP.
2
0"
2

"
TYPICAL JOIST BEAM CONNECTION
NTS ST-L27 SCALE:
REF:
I
ST-L27
TYPICAL RIGID MOMENT CONNECTION
BEAM PER PLAN
CONNECTION
STANDARD SHEAR
THICKNESS
SIDE TO MATCH BEAM FLANGE
PLATES TOP AND BOTTOM, EACH
FULL WIDTH COLUMN STIFFENER
TYP.
tf
2
C
L COLUMN
M
(TYP.)
TOP AND BOTTOM
FULL PEN WELD
(DENOTES AS ON PLANS)
NTS ST-L27
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
M
e
c
h
a
n
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
M
E
L
A
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PAULCO
Engineering, Inc.
Columbia, MD
GENERAL NOTES AND ABBREVIATIONS
DECEMBER 2013
VH
GK
VH

ME-L01
118 NONE
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
OR
DENOTES
EQUIPMENT DESIGNATION
SYMBOL DESCRIPTION
OR
DUCT < 12"
WHERE EACH
A+B
B A
IS TAKEN OR DRAWN
DRAWING NUMBER WHERE ELEVATION OR SECTION
INDICATES DIRECTION OF CUTTING PLANE
INDICATES SECTION OR ELEVATION DESIGNATION
WIDTH < 12"
DUCTWORK WITH
FOR RECTANGULAR
LONG RADIUS ELBOW
PCH-X
NUMERICAL DESIGNATION
COMBINATION BALANCING VALVE & FLOWMETER FITTING
CHS(G)
CHR(G)
CHILLED WATER (GLYCOL) SUPPLY PIPE
CHILLED WATER (GLYCOL) RETURN PIPE
WATER PRESSURE DROP
WITHOUT
WITH
WATER GAGE
WATER COLUMN
WET BULB
WIDTH
VENT THRU ROOF
VENT PIPE
VARIABLE FREQUENCY CONTROLLER
VELOCITY
VARIABLE AIR VOLUME
VOLT AMPERES
VOLTS
UNDERGROUND STORAGE TANK
UNLESS OTHERWISE NOTED
DOOR UNDER CUT
TYPICAL
TOTAL STATIC PRESSURE
THERMODYNAMIC TRAP
TRENCH DRAIN
TOTAL HEAT
TEMPERATURE
STRUCTURAL
STEEL
STAINLESS STEEL
SECONDARY (OVERFLOW) RAIN LEADER
SECONDARY (OVERFLOW) ROOF DRAIN
SQUARE
SPECIFICATION/PROJECT MANUAL
STATIC PRESSURE
SOUND LINING
SENSIBLE HEAT
SQUARE FEET
SUPPLY AIR
REMOVE EXISTING
REDUCED PRESSURE ZONE
REVOLUTIONS PER MINUTE
RELIEF AIR
RAINLEADER
RADIANT HEATING PANEL
RELATIVE HUMIDITY
REQUIRED
ROOF DRAIN
RADIATED
RETURN AIR
RADIUS
QUANTITY
POLYVINYL CHLORIDE
PROPELLER UNIT HEATER
POUNDS PER SQUARE INCH (GAGE)
PRESSURE REDUCING VALVE
PRESSURE
PARTS PER MILLION
POUNDS PER HOUR (STEAM)
PLUMBING
PHASE
PROPYLENE GLYCOL
POWER FACTOR
PRESSURE DROP
OUTSIDE SCREWAND YOKE
OPEN END DUCT
ON CENTER
OUTDOOR AIR
NUMBER
NORMALLY OPEN
NOT IN CONTRACT
NORMALLY CLOSED
NOISE CRITERIA
NATURAL
MOUNTED
MOTOR OPERATOR
MINIMUM
MANUFACTURER
THOUSAND BTU'S PER HOUR
MECHANICAL
MAXIMUM
LEAVING WATER TEMPERATURE
LEAVING WET BULB
LEAVING
LOWPRESSURE
LINEAR FEET
LEAVING DRY BULB
POUND(S)
LEAVING AIR TEMPERATURE
LENGTH
KILOWATT
KILOVOLT AMPERES
INVERT ELEVATION
INCH OR INCHES
INVERTED BUCKET TRAP
WPD
W/O
W/
WG
WC
WB
W
VTR
VP
VFC
VEL
VAV
VA
V
UST
UON
UC
TYP
TSP
THD
TD
TH
TEMP
STRUCT
STL
S/S
SRL
SRD
SQ
SPEC
SP
SL
SH
SF
SA
RX
RPZ
RPM
RLF
RL
RHP
RH
REQ'D
RD
RAD
RA
R
QTY
PVC
PUH
PSI(G)
PRV
PRESS.
PPM
PPH
PLBG
PH
PG
PF
PD
OS&Y
OED
OC
OA
NO.
N.O.
NIC
N.C.
NC
NAT
MTD
MO
MIN
MFR
MBH
MECH
MAX
LWT
LWB
LVG
L.P.
LF
LDB
LB(S)
LAT
L
KW
KVA
INV
IN
IB
HERTZ
DOMESTIC HOT WATER RECIRCULATING PIPE
DOMESTIC HOT WATER PIPE
HEATING, VENTILATING & AIR CONDITIONING
HIGH PRESSURE
HORSEPOWER
HORIZONTAL
HOSE END DRAIN
HEIGHT
GALLONS PER MINUTE
GALLONS PER HOUR
GALVANIZED
GALLON
GAGE
FINNED TUBE RADIATION
FEET OF HEAD PRESSURE
FLOOR SINK
FEET PER SECOND
FEET PER MINUTE
FINS PER INCH
FLAT ON TOP
FLAT ON BOTTOM
FLOOR
FIRE HOSE CABINET
FINISHED FLOOR
FIRE DEPARTMENT VALVE
FIRE DEPARTMENT CONNECTION
FLOOR DRAIN
FLOOR CONTROL VALVE ASSEMBLY
FAN COIL UNIT
FLOAT & THERMOSTATIC TRAP
DEGREES FAHRENHEIT
EXPOSED
EXISTING
ENTERING WATER TEMPERATURE
ENTERING WET BULB
ET CETERA
EXTERNAL STATIC PRESSURE
ENTERING
ELEVATION OR ELEVATOR
ELECTRICAL, ELECTRIC
EXPANSION JOINT
ETHYLENE GLYCOL
EFFICIENCY
ENTERING DRY BULB
ENTERING AIR TEMPERATURE
EXHAUST AIR
DRAWING
DOMESTIC WATER
DOWN
DIFFUSER
DIAMETER
DRAINAGE FIXTURE UNITS
DESIGNATION
DIRECT DIGITAL CONTROL
DIGITAL CONTROL PANEL
DOUBLE
DECIBEL (REFERENCE "A" SCALE)
DRY BULB OR DECIBEL
DRAIN OR DEPTH
DOMESTIC COLD WATER PIPE
CONNECT TO EXISTING
CABINET UNIT HEATER
CUBIC FEET
CONDENSATE RETURN UNIT
CONTINUATION
CONNECTION, CONNECT
CONCRETE
COMPRESSED
CARBON DIOXIDE
CLEANOUT
CEILING
CUBIC FEET PER MINUTE
CEILING DIFFUSER
CONSTANT AIR VOLUME
DEGREES CELSIUS
BACKFLOWPREVENTER
BRITISH THERMAL UNITS PER HOUR
BOTTOM
BOTTOM OF PIPE
BUILDING
BRAKE HORSEPOWER
BACK WATER VALVE
AVERAGE WATER TEMPERATURE
AVERAGE
AIR TERMINAL UNIT
AIR TEMPERATURE RISE
ATMOSPHERE
AUTOMATIC TEMPERATURE CONTROL
ABOVEGROUND STORAGE TANK
ARRANGEMENT
ARCHITECT, ARCHITECTURAL
APPROXIMATE
AIR PRESSURE DROP
ALUMINUM
AIR HANDLING UNIT
ABOVE FINISHED FLOOR
ACCESS DOOR
AIR CONDITIONING
ABOVE
ABBREVIATION
HZ
HWR
HW
HVAC
H.P.
HP
HORIZ
HED
H
GPM
GPH
GALV
GAL
GA
FTR
FT HD
FS
FPS
FPM
FPI
FOT
FOB
FL
FHC
FF
FDV
FDC
FD
FCVA
FCU
F&T
EXP
EX
EWT
EWB
ETC
ESP
ENT
ELEV
ELEC
EJ
EG
EFF
EDB
EAT
EA
DWG
DW
DN
DIFF
DIA
DFU
DESIG
DDC
DCP
DBL
DBA
DB
D
CW
CX
CUH
CU FT
CRU
CONT
CONN
CONC
COMP
CO2
CO
CLG
CFM
CD
CAV
C
BFP
BTUH
BTM
BOP
BLDG
BHP
BWV
AWT
AVG
ATU
ATR
ATM
ATC
AST
ARRG
ARCH
APPROX
APD
ALUM
AHU
AFF
AD
A/C
ABV
ABBREV
DUCT MOUNTED CARBON DIOXIDE SENSOR/TRANSMITTER
DUCT MOUNTED HUMIDITY SENSOR/TRANSMITTER
DUCT OR PIPE MOUNTED TEMPERATURE SENSOR/TRANSMITTER
FAN POWERED AIR TERMINAL UNIT WITH HEATING COIL
EXHAUST AIR DEVICE
RETURN AIR DEVICE
WITH ACCESS DOOR
COMBINATION FIRE AND SMOKE DAMPER
WATER MOTOR GONG
FIRE DEPARTMENT SIAMESE FREESTANDING CONNECTION
FIRE DEPARTMENT SIAMESE WALL CONNECTION
DTS
DTR DUAL TEMPERATURE RETURN
DUAL TEMPERATURE SUPPLY
OXYGEN GAS PIPE O
NITROUS OXIDE GAS PIPE
DIR DEIONIZED WATER RETURN PIPE
VENT PIPE
DOMESTIC COLD WATER PIPE
DOMESTIC HOT WATER PIPE (TEMP. IF INDICATED)
DOMESTIC HOT WATER RECIRCULATING PIPE
RR REFRIGERANT RELIEF PIPE
FIRE SUPPRESSION PRESSURE SWITCH
FIRE SUPPRESSION FLOWSWITCH
PREACTION VALVE
DELUGE VALVE
DRY PIPE VALVE W/ACCELERATOR
DRY PIPE VALVE
ALARM CHECK VALVE
FIRE SUPPRESSION DOUBLE CHECK BACKFLOWPREVENTER
FIRE SUPPRESSION INDICATING VALVE W/TAMPER SWITCH
FLAT OVAL
FLOOR SINK
A
V
SG
N
HG
CR
CS
PHR
PHS
RS
RL
SANPD
SWPD
VV
G
FND
NP
F
P/A
DP
ROR
ROS
CHR
LPS
TRW
FOR
FOS
DIS
STM(H)
PCR
LPR
MPR
HPR
MPS
HPS
HS
HR
CHS
SW
CRV
CRW
D
SSW
24/12 24x12
ABBREVIATIONS
STEAM TRAP
VOLUME DAMPER FOR ROUND DUCT
"LO-LOSS" OR CONICAL TEE WITH
DAMPER FOR RECTANGULAR DUCTS;
SPIN-IN FITTING WITH VOLUME
RECTANGULAR OR ROUND DUCT
DOMESTIC WATER BACKFLOWPREVENTER
BACK WATER VALVE (ARROWINDICATES DIRECTION OF FLOW)
SHOCK ABSORBER
FIRE DEPARTMENT VALVE
FLOWMETER FITTING
PRESSURE AND TEMPERATURE PLUG
MANUAL AIR VENT
AUTOMATIC AIR VENT
CHECK VALVE (ARROWINDICATES DIRECTION OF FLOW)
MANUAL BALANCING VALVE
ECCENTRIC REDUCER
CONCENTRIC REDUCER
HOSE END DRAIN
FLANGED CONNECTION
CENTER LINE
CUBIC FEET PER MINUTE
INVERT ELEVATION
DOMESTIC WATER RISER DESIGNATION
DIAMETER
PIPE DOWN
PIPE/DUCT CAP
PIPE UP
PIPE ANCHOR
PIPE GUIDE
HOSE BIBB
DIFFUSER INLET
SHARP BENDS, FULL SIZE OF
LONG. KEEP FREE OF KINKS &
INSULATED FLEX DUCT, MAX 6 FT
SUPPLY AIR DEVICE
F
L
O
W
A
IR
MIN 6"
LENGTH = 1/4 WIDTH,
DUCTWORK
FOR ROUND
LONG RADIUS ELBOW
MIN 12" DAMPER
VOLUME
DRAWING CONVENTIONS
DUCTWORK CONVENTIONS
FLEXIBLE CONNECTION (DUCT)
SECONDARY (OVERFLOW) STORM WATER PIPE
NON-POTABLE WATER PIPE
SPECIALTY GAS PIPE
NITROGEN GAS PIPE
COMPRESSED AIR PIPE
CONDENSER WATER RETURN PIPE
CONDENSER WATER SUPPLY PIPE
PRIMARY HEATING WATER RETURN PIPE
PRIMARY HEATING WATER SUPPLY PIPE
REFRIGERANT SUCTION PIPE
SANITARY PUMPED DISCHARGE PIPE
CHEMICAL RESISTANT VENT PIPE
FOUNDATION DRAIN PIPE
CHEMICAL RESISTANT WASTE PIPE
DRY-PIPE FIRE SUPPRESSION PIPE
SANITARY/WASTE PIPE
STORM WATER PIPE
A/C CONDENSATE AND EQUIPMENT DRAIN PIPE
PREACTION FIRE SUPPRESSION PIPE
FIRE SUPPRESSION AND WET-PIPE SPRINKLER PIPE
REVERSE OSMOSIS WATER RETURN PIPE
REVERSE OSMOSIS WATER SUPPLY PIPE
FLOWDIRECTION ARROW
PRESSURE RELIEF VALVE
PRESSURE REDUCING VALVE
PRESSURE GAGE WITH ISOLATION VALVE
SHUTOFF VALVE (IN HORIZONTAL / IN VERTICAL)
CLEANOUT IN VERTICAL
CLEANOUT IN HORIZONTAL
NATURAL GAS PIPE
STORM WATER PUMPED DISCHARGE PIPE
REFRIGERANT LIQUID PIPE
HOT GAS REFRIGERANT PIPE
STEAM VAPOR VENT PIPE
FLOOR DRAIN
AREA DRAIN
TRENCH DRAIN
ROOF DRAIN/SECONDARY (OVERFLOW) ROOF DRAIN
SANITARY RISER DESIGNATION
SUPPLY AIR FLOWDIRECTION
TEMPERATURE GAGE/THERMOMETER
RETURN AIR FLOWDIRECTION
NON-FREEZE CONCEALED OUTLET WALL HYDRANT
TRAP PRIMER PIPE
SUPPLY AIR TERMINAL UNIT
DUCT MOUNTED REHEAT COIL
SUPPLY AIR TERMINAL UNIT WITH REHEAT COIL
FINNED TUBE RADIATION OR RADIANT HEATING PANEL
P-X PLUMBING FIXTURE DESIGNATION,
THROTTLING VALVE
STRAINER WITH VALVE
UNION
VACUUM PIPE
DUCT OFFSET DOWN IN DIRECTION OF ARROW
DUCT (SIZE IN INCHES; FIRST FIGURE IS SIDE SHOWN)
LINEAR SLOT DIFFUSER WITH PLENUM
SOUND LINED DUCT (DIMENSIONS SHOWN ARE AIR-SIDE)
DUCT MOUNTED SMOKE DETECTOR
FLEXIBLE CONNECTION (PIPING)
ROUND FLEXIBLE DUCT
DUCT OFFSET UP IN DIRECTION OF ARROW
SOUND ATTENUATOR
TRANSITION ROUND TO RECTANGULAR
SPACE TEMPERATURE SENSOR OR THERMOSTAT
SPACE CARBON DIOXIDE SENSOR
SUPPLY AIR DEVICE
FABRICATED PLENUM
SIDEWALL DIFFUSER W/ FIELD
DUCT OR WALL MOUNTED AIR DEVICE
SPACE HUMIDITY SENSOR OR HUMIDISTAT
SINGLE-LINE
PLAN VIEW...
SYMBOL
HUMIDIFICATION STEAM PIPE
DEIONIZED WATER SUPPLY PIPE
TREATED WATER PIPE
FUEL OIL RETURN PIPE
FUEL OIL SUPPLY PIPE
PUMPED CONDENSATE RETURN PIPE
MEDIUM PRESSURE CONDENSATE RETURN PIPE
HIGH PRESSURE CONDENSATE RETURN PIPE
HIGH PRESSURE STEAM PIPE (_PSIG)
CHILLED WATER RETURN PIPE
CHILLED WATER SUPPLY PIPE
HEATING WATER SUPPLY PIPE
HEATING WATER RETURN PIPE
LOWPRESSURE STEAM PIPE (_PSIG)
MEDIUM PRESSURE STEAM PIPE (_PSIG)
LOWPRESSURE CONDENSATE RETURN PIPE
RETURN/OUTDOOR/RELIEF AIR DUCT (UP,DOWN)
SUPPLY AIR DUCT (UP,DOWN)
EXHAUST AIR DUCT (UP,DOWN)
MANUAL VOLUME DAMPER
SMOKE DAMPER WITH ACCESS DOOR
FIRE DAMPER WITH ACCESS DOOR
PROPELLER UNIT HEATER
SYMBOLS
BOUNDARY LINE
DUCTWORK OF 12" OR GREATER IN WIDTH
ELBOWW/TURNING VANES FOR RECTANGULAR
MIN 6"
WIDTH, 4
1 TAP LENGTH =
ACTUAL FITTING...
TO REMAIN
LIGHT LINE WEIGHT DESIGNATES EXISTING WORK
DEMOLITION PLANS
NEWWORK PLANS, AND REMOVAL WORK ON
HEAVY LINE WEIGHT DESIGNATES NEWWORK ON
ITEM
NOTE LIST ON DRAWING FOR DESCRIPTION OF
SPECIAL NOTE DESIGNATION. REFER TO SPECIAL
SIZE AND TYPE
AIR DEVICE DESIGNATION. REFER TO SCHEDULE FOR
DEMOLITION WORK TERMINATION POINT
POINT OF CONNECTION, NEWTO EXISTING
DESCRIPTION
INDICATES AIR DEVICE
INDICATES SPECIAL NOTE
SAN
TEMPERED WATER PIPE TW
ENERGY RECOVERY SUPPLY PIPE ERS
ERR ENERGY RECOVERY RETURN PIPE
AUTOMATIC BALANCING VALVE

WH
SA
HB
CO
CO
C
/
CONTROL DAMPER
STATIC PRESSURE SENSOR/AIR FLOWSTATION
THREE WAY CONTROL VALVE
TWO WAY CONTROL VALVE
FAN INLET AIR FLOWMEASURING STATION
CURRENT SENSING RELAY
FLOWSWITCH
FREEZESTAT
DIFFERENTIAL PRESSURE SWITCH
DIFFERENTIAL PRESSURE TRANSMITTER
OR
MAGNAHELIC PRESSURE GAGE
MANUAL OVERRIDE SWITCH
OR OR
O
N
MX
X
S
X
W
X
X
X
DN DN
UP UP
L C
XX.XX
TP
T

H

C

S S
T


INDICATES CUT LINE
MXX
X
INDICATES DETAIL DESIGNATION
DRAWING WHERE DETAIL IS DRAWN
EQUIPMENT TYPE DESIGNATION
PAULCO
Engineering, Inc.
Columbia, MD
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
M
e
c
h
a
n
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
M
E
L
A
1
0
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8' 8' 0 16'
SCALE:"=1'-0"
N
1
1
1
1

AND CONTROL WIRES.
ROOF. PROVIDE ALL ASSOCIATED PIPING
MOUNT ASSOCIATED CONDENSING UNIT ON
DRAWING NOTES:
YARD LEVEL FLOOR PLAN - HVAC
DECEMBER 2013
VH
GK
VH

ME-L10
119 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
UH6
UH7A
UH7B UH8
AC-5
AC-4
UH9 1" 1" 1" "
'UP
6" DIA.
UH6A
"UP
EF-9
UH-10
EF-70
EF-1 EF-2 EF-3
EF-11
SUPPLY STORAGE
CLEANING
STORAGE
BULK FLUID
100
T.R.
UNISEX
101
ROOM
BREAK
L.R.
102
OFFICE
L.R.
103
STORAGE
L.R. MAINT.
104
105
ELEC.
106
107
PROTECT.
FIRE
121
ROOM
COMPRESSOR
M
A
T
C
H

L
I
N
E
UH1
UH2
UH3
AC-1
AC-2
UH4
UH5
1" UP
1"
1"
6" DIA.
1" UP
UH5A
"
EF-4 EF-5
EF-6
EF-7
EF-8
CORRIDOR
BREAK ROOM
CLEANING
E-3
SERVICE
WATER
SERVICE
ELECTRICAL
SERVICE
ELECTRICAL
EMERGENCY
108
PROTECT.
FIRE
111
109
T.R.
UNISEX 110
T.R.
UNISEX
112
113
OFFICE
CLEANING
S2
S2-1
STAIR
114
ELEV.
115 116
PROTECT.
FIRE
T.R.
UNISEX
T.R.
UNISEX
CORRIDOR
M
A
T
C
H

L
I
N
E
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
PAULCO
Engineering, Inc.
Columbia, MD
15 15.1 14 13 12 16 17 18 19 20
A
23 23.1 20 15 15 15 15 15 15
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
M
e
c
h
a
n
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
M
E
L
A
1
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8' 8' 0 16'
SCALE:"=1'-0"
N
YARD LEVEL ROOF PLAN - HVAC
DECEMBER 2013
VH
GK
VH

ME-L11
120 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
(AC-5)
CU-5-1
M
A
T
C
H

L
I
N
E
(AC-4)
CU-4-1
(AHU-1)
CU-1-2
(AHU-1)
CU-1-1 (AHU-2)
CU-2-1
(AHU-3)
CU-3-2
(AHU-3)
CU-3-1
M
A
T
C
H

L
I
N
E
S3
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
PAULCO
Engineering, Inc.
Columbia, MD
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
M
e
c
h
a
n
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
M
E
L
A
1
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8' 8' 0 16'
SCALE:"=1'-0"
N
SCALE:
WASH BUILDING FLOOR PLAN
"=1'-0"
SCALE: "=1'-0"
WASH BUILDING ROOF PLAN
WASH BLDG FLOOR AND ROOF PLANS - HVAC
DECEMBER 2013
VH
GK
VH

ME-L12
121 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
KEY PLAN
117
WASH BAY
118
ELEC.
119
COMM. CL.
UH-13
UH-14
UH-12
UH-11
ELEC. COMM. CL.
TRAIN WASH
24 25 26 27
AA
A
B
A.3
A.4
A.8
C
B.6
B.8
C.8
B.5
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
M
e
c
h
a
n
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
M
E
L
A
1
3
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PAULCO
Engineering, Inc.
Columbia, MD
KEY PLAN
AHU-1
AHU-2
RA
RA
RA
T
6"DIA.
150
150
8
10
6"DIA.
6"DIA.
6"DIA.
6"DIA.
6"DIA. 6"DIA.
6"DIA.
130 155
T
T
8
10
T
T
T
T
50
50
10
6
10
10
6"DIA.
6"DIA. 6"DIA.
100
100
50
75
50
110
110
150
6"DIA. 6"DIA.
10
8
10
14

100
100
EG-1
75
6
10
T
6"DIA. 6"DIA.
110
160
6
10
100
EG-1
1" UP 1" UP
50
50
125
125
6"DIA. 6"DIA. 6"DIA.
8
10
6"DIA.
6"DIA. 6"DIA.
90
120
"
8
10
8
8
8
8
6"DIA. 6"DIA.
100
100
T
T
T
6"DIA.
100
CD-1
" "
10"DIA.
400
10"DIA.
14
20 10"DIA. 10"DIA.
400
90
CD-1
8
8
AC-11
VAV-2
VAV-1
VAV-3
VAV-4
AC-10
T
VAV-5
VAV-8
VAV-9
VAV-10
VAV-7
VAV-6
AC-7
AC-6
AC-8
226 214
214A
213
211
212
224
225
209
210
204
208
207
206
205
200
202
216
217
220
221
222
218 219
223
215
E-3
203
201
LOBBY
S2-3
STAIR
ROOM
TEAM
VEST.
ELEV.
I.T.
CORR.
MASTER
YARD
ROOM
INCIDENT
CORR.
CORR.
CORR.
S2
SUPER.
TRANS.
COPY
ADMIN./
SUPER.
TRANS.
ASST.
COORD.
WORK BLK
CORR.
ROOM
TEAM
T.R.
UNISEX
ELEC.
MECH.
EQUIP.
LOST/FND
DISPATCH
CONTROL CNTR
OPERATIONS
SUPER.
T.R.
UNISEX
OFFICE
EQUIP.
TECH.
238
MACHINE CL
ELEVATOR
MATCH LINE
AHU-2
RA
6"DIA. 6"DIA.
8
10
8
8
8
8
6"DIA. 6"DIA.
100
100
T
T
6"DIA.
100
CD-1
" "
1" 1"
" "
10"DIA.
400
10"DIA.
400
14
20 10"DIA. 10"DIA.
400
400
90
CD-1
8
8
9
10
150
EC-1
6
12
UP 12
14
160
CD-1
" "
6"DIA. 6"DIA.
160
CD-1
160
CD-1
160
CD-1
160
CD-1
160
CD-1
160
CD-1
95
CD-1
95
CD-1
95
CD-1
95
CD-1
75
CD-1
50
CD-1
T
T
T
T
6"DIA.
6"DIA.
6"DIA.
6"DIA.
6"DIA.
6"DIA. 6"DIA.
6"DIA.
6"DIA. 6"DIA.
6"DIA. 6"DIA.
10
10
10
18
10
10
10
10
95
6"DIA.
10
6
8
12
350
EG-1
350
EG-1
VAV-8
VAV-9
VAV-10
VAV-7
AC-7
AC-8
AC-9
VAV-12
VAV-11
237
236
234
232
233
235
S3
228
227
229
226 214
231
214A
230
213
203
CORR.
CORR.
S3-1
STAIR
VEST.
EQUIP.
LOST/FND
DISPATCH EQUIP.
ROOM
QUIET
T.R.
UNISEX
CORR.
T.R.
WOMENS
T.R.
MENS
LOCKERS
JAN. CL.
MAINT.
BLDG.
KITCHENETTE
OPER. BRK RM/
MATCH LINE
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
N
8' 8' 0 16'
SCALE: 1/8"=1'-0"
SCALE:
OFFICE FIRST FLOOR PLAN - HVAC
"=1'-0"
1

AND CONTROL WIRES.
ROOF. PROVIDE ALL ASSOCIATED PIPING
MOUNT ASSOCIATED CONDENSING UNIT ON
DRAWING NOTES:
1
1
11
1
11
1
OFFICE FIRST FLOOR PLAN - HVAC
DECEMBER 2013
VH
GK
VH

ME-L13
122 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
PAULCO
Engineering, Inc.
Columbia, MD
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
M
e
c
h
a
n
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
M
E
L
A
1
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
N
8' 8' 0 16'
SCALE:"=1'-0"
SCALE:
SECOND FLOOR PLAN - HVAC
"=1'-0"
1

BOILER FLUE THROUGH ROOF (TYPICAL).
DRAWING NOTES:
1
OFFICE SECOND FLOOR PLAN - HVAC
DECEMBER 2013
VH
GK
VH

ME-L14
123 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
316
313
310
312
307
302
306
305
303
311
301
308
S2
304
300
309
E-3
S2-4
STAIR
ELEV.
CONF.
CORR.
CORR.
CORR.
LOBBY
ELEV.
COPY
ADMIN./
CORR.
I.T.
DIRECTOR
L.R. DEP.
DIR.
L.R.
T.R.
UNISEX
ELEC.
ROOM
INCIDENT
ROOM
COMM.
MECH.
T.R.
UNISEX
T.R.
UNISEX
AHU-3
1" DN 1" DN
EF
P-1
P-2
TANK
EXPANSION
SEPARATOR
AIR
RA
B-1 B-2 B-3
8" DIA.
10" DIA.
410
410
10" DIA.
" "
90
6" DIA.
6" DIA.
6" DIA.
6" DIA.
200
200
225
225
" "
130
10
10
10
10
10
12
10
12
200
EG-1
320 300
EG-2
6
10
100
EG-1
8"DIA. 8"DIA.
8"DIA.
285
8"DIA.
285
270
8"DIA.
1" 1'
300
EG-2
1" DN 1" DN
8"DIA.
2'
1" 1"
320
12
14
6
10
100
EG-1
VAV-14
VAV-13
VAV-15 VAV-15
VAV-16
FRESH AIR
OUTSIDE
MATCH LINE
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
S3
321
320
317
319 318
314
315
316
CORR.
CORR.
T.R.
UNISEX
T.R.
UNISEX
JAN. CL. STOR.
CLASSROOM
OFFICE
TRAIN.
S3-2
STAIR
AHU-3
EF
8" DIA.
100
EG-1
100
EG-1
DN FD 12
4
100
EG-1
100
EG-1
100
EG-1
90
CD-1
210
CD-2
6" DIA.
8" DIA.
8" DIA.
210
CD-2
210
CD-2
210
CD-2
8" DIA.
8" DIA.
8" DIA. 8" DIA.
6" DIA.
310
CD-2
310
CD-2
75
CD-1
T
320
T
2'
1" 1"
6
10 6
10
2
3
6
12
VAV-17
VAV-18
FRESH AIR
OUTSIDE
MATCH LINE
PAULCO
Engineering, Inc.
Columbia, MD
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
M
e
c
h
a
n
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
M
E
L
A
8
0
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
CD-1 SUPPLY LAY-IN 24x24 6" DIA STEEL DIFFUSER, 4-WAY, ADJUSTABLE 1-230 30 0.1 TITUS TMSA 1
CD-2 SUPPLY LAY-IN 24x24 8" DIA STEEL DIFFUSER, 4-WAY, ADJUSTABLE 231-340 30 0.1 TITUS TMSA 1
CD-3 SUPPLY LAY-IN 24x24 10" DIA STEEL DIFFUSER, 4-WAY, ADJUSTABLE 341-430 30 0.1 TITUS TMSA 1
CD-4 SUPPLY LAY-IN 24x24 12" DIA STEEL DIFFUSER, 4-WAY, ADJUSTABLE 431-620 30 0.1 TITUS TMSA 1
CR-1 RETURN LAY-IN 24x24 10x6 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 1-270 30 0.1 TITUS 50F 1
CR-2 RETURN LAY-IN 24x24 10x10 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 271-470 30 0.1 TITUS 50F 1
CR-3 RETURN LAY-IN 24x24 12x12 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 471-700 30 0.1 TITUS 50F 1
CR-4 RETURN LAY-IN 24x24 14x14 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 701-970 30 0.1 TITUS 50F 1
CR-5 RETURN LAY-IN 24x24 16x16 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 971-1,290 30 0.1 TITUS 50F 1
CR-6 RETURN LAY-IN 24x24 18x18 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 1,291-1,650 30 0.1 TITUS 50F 1
EG-1 EXHAUST SURFACE 12X8 10x6 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 1-270 30 0.1 TITUS 50F 1
EG-2 EXHAUST SURFACE 12X12 10x10 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 271-470 30 0.1 TITUS 50F 1
EG-3 EXHAUST SURFACE 14X14 12x12 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 471-700 30 0.1 TITUS 50F 1
EG-4 EXHAUST SURFACE 16x16 14x14 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 701-970 30 0.1 TITUS 50F 1
TG-1 TRANSFER SURFACE 14x14 12x12 ALUMINUM 1/2" x 1/2" EGGCRATE GRID, FIXED 291-440 - 0.04 TITUS 50F 1
SR-1 SUPPLY SURFACE 12x8 10x6 STEEL BAR GRILLE, DOUBLE DEFLECTION, ADJ. 1-290 30 0.1 TITUS 300RS-HD 1, 2
WG-1 TRANSFER SURFACE 20x12 18x10 ALUMINUM BAR GRILLE, 0-DEG FIXED 291-600 15 0.04 TITUS 60FL-HD 1
RETURN SURFACE 36x12 18x18 STEEL BAR GRILLE, 0-DEG FIXED 1,281-1,370 20 0.1 TITUS 350RL-HD 1
1 - WHITE FINISH
2 - WITH OPPOSED BLADE DAMPER
DIFFUSER, REGISTER, AND GRILLE SCHEDULE
DESIGNATION SERVICE MOUNTING
(IN.)
FACE SIZE
(IN.)
NECK SIZE
MATERIAL PATTERN CFM RANGE MAX. NC
(IN. WG)
MAX. APD
BASIS OF DESIGN COMMENTS
CFM
OA
930
CFM
MAX
7600
LOCATION
MECH ROOM
TYPE
VERTICAL
FAN SECTION
ID NO.
AHU-1
AIR HANDLING UNIT SCHEDULE
TRANE 17
TRANE 3
TRANE 17
16.8
280.1 231.0 506 78.4 53.6 63.4 52.0 147.5 0.52 0.99 59 14.8 0.61 2.2 450 2 - -
BASIS OF DESIGN WEIGHT
lbs
UNIT
MAX
-
-
THICK
(IN.) INITAL
-
-
2
2
(IN. WC)
RATING
MERV
ASHRAE
FILTERS
VEL.
MAX
FACE
8 & 15 402
300
FPM
TYPE
GPM
11.8 0.4
PRESSURE DROP
(IN. WC)
FINAL
2.2
2.2
LWT EWT
0.34
120
1.7
140
LAT EAT
AIR SIDE
75 61
60
HOT WATER HEATING COIL
0.073
0.045
MAX
APD
(IN. WC)
APD
MAX
0.28
IN. WC
MBH
TOTAL
118.1
WBT
LAT
WBT
EAT
AIRSIDE
DBT
LAT
53.1 64.7 54.4
EAT
DBT
MAX
VEL. PPM
FACE
COOLING COIL
78.4 343
MBH
SENSIBLE
26.3
TOTAL
MBH
34.4
MIN
ROWS
WATER SIDE
AHU-2 1000 160
AHU-3 8500 1500
SUPPLY
FAN
RPM
2817 AIR FOIL
IN.
FIN PER
MAX
7.8
8.67
MAX
FACE
VEL. PPM
MIN
ROWS
MAX
FIN PER
IN.
400
567
507 1
7.7
6.7
6.7
(FT. WC)
MAX
WPD
ACCESS
DRAWTHRU
SIDE
ESP IN.
2.0
BHP
12.2 SIDE 244.1 4 201.5 452 10.2 77.6 63.3 53.4 52.2 0.4
MHP
15 460-3-60
V-PH-HZ
INTERNAL FACE & BYPASS DAMPERS FOR COIL PROVIDE MIXING BOX WITH ANGLED FILTER
- 2526
2488
1.5
2.0
1.94
12.9
3
15
REMARKS
1 2 3
MOTOR COMPATIBLE WITH VFD HEATING COIL PERFORMANCE IS BASED ON MIN OA
4
1ST FLOOR
MECH ROOM
1ST FLOOR
MECH ROOM
2ND FLOOR
VERTICAL
DRAWTHRU
VERTICAL
DRAWTHRU AIR FOIL
460-3-60
460-3-60
4
4
REFRIGERANT
R410A
R410A
R410A
1
1
75
75
140
140
120
120
6
6
6
8 & 15
8 & 15
SIDE
SIDE
5 6 7
1 2 3 4 5 6
1 2 3 4 5 6 7
DX COOLING COIL PROVIDE MERV 8 PREFILTER, MERV 15 12" CARTRIDGE FINAL FILTER FOUR SEPARATE DISTRIBUTION CIRCUITS IN COOLING COIL
INPUT
BOILER SCHEDULE
DESIGNATION
B-3
B-2
B-1
BASIS OF DESIGN
BOILER ROOM
BOILER ROOM
BOILER ROOM
LOCATION
FULTON
FULTON
FULTON
MODEL
PHW300
PHW300 300
300
300
(MBH) V/PH/HZ AMPS(MAX/RUN)
4.2/0.6
4.2/0.6
4.2/0.6
120/1/60
120/1/60
120/1/60
MAT. GAS
MAT. GAS
MAT. GAS
PRIMARY
11
11
11
FUEL
PHW300
REMARKS
PROVIDE WITH EXHAUST MUFFLER
MANUFACTURER
AGA RATED
OUPUT
(MBH)
AGA RATED
270
270
270
TEMP
RANGE
WATER
OPERATING
PRESSURE
MAX.
60 PSIG
60 PSIG
60 PSIG
CHARACTERISTICS
BURNER MOTOR
PRESSURE
(IN.)
MAX. FUEL
PUMP SCHEDULE
DESIGNATION DESCRIPTION LOCATION MANUFACTURER
-
HP
MOTOR COMPATIBLE WITH VFD
COMMENTS
END SUCTION -
MOTOR
RPM V/PH/HZ
460/3/60
END SUCTION BOILER ROOM BELL & GOSSETT - -
BOILER ROOM BELL & GOSSETT
MODEL GPM
HEAD
MAX
(FT.)
1510-
1510- 460/3/60
TERMINAL UNIT SCHDULE
ID NO. SYSTEM TYPE ACTUATOR
MAX
CFM
MIN
CFM
MIN INLET
SP
IN. WG
MIN INLET
SIZE
IN.
REHEAT COIL SOUND DATA
CFM TOTAL
MBH
EAT

LAT
F
MAX
APD
IN. WG
EWT
F
MAX
GPM
MIN
ROWS
MAX
WPD
FT
DISCHARGE
NC
RAD
NC
MANUFACTURER REMARKS
VAV-1 VAV DDC 1.0 140 TITUS DESV-
VAV-2 VAV DDC 1.0 140 TITUS DESV-
VAV-3 VAV DDC 1.0 140 TITUS DESV-
VAV-4 VAV DDC 1.0 140 TITUS DESV-
VAV-5 VAV DDC 1.0 140 TITUS DESV-
VAV-6 VAV DDC 1.0 140 TITUS DESV-
VAV-7 VAV DDC 1.0 140 TITUS DESV-
VAV-8 VAV DDC 1.0 140 TITUS DESV-
VAV-9 VAV DDC 1.0 140 TITUS DESV-
VAV-10 VAV DDC 1.0 140 TITUS DESV-
VAV-11 VAV DDC 1.0 140 TITUS DESV-
VAV-12 VAV DDC 1.0 140 TITUS DESV-
VAV-13 VAV DDC 1.0 140 TITUS DESV-
VAV-14 VAV DDC 1.0 140 TITUS DESV-
VAV-15 VAV DDC 1.0 140 TITUS DESV-
VAV-16 VAV DDC 1.0 140 TITUS DESV-
P-1
P-2
WG-2
1
1
1
1
1
1
1
1
7 6 5 4 3 2 1
MECHANICAL SCHEDULES AND DETAILS
DECEMBER 2013
VH
GK
VH

ME-L80
124 NONE
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
M
e
c
h
a
n
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
M
E
L
A
8
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PAULCO
Engineering, Inc.
Columbia, MD
NO
FAN
LOCATION SERVING CFM ESP (IN)
HP MAX BHP VOLTS PHASE
RPM
DIA
FAN
MIN
TYPE
WHEEL
CLASS
TYPE
DRIVE
CONTROL
METHOD OF
MANUFACTURER / MODEL
EF-1
STORAGE
LR MAINTENANCE
- - - - - - - - - - - - -
- - - - - - - - -
- - - - - - - - -
- - - - - - - - -
- - - - - - - - -
- - - - - - - - -
MOTOR
FAN SCHEDULE
-
-
-
-
-
SIZES OF REFRIGERANT PIPING SHALL BE AS RECOMMENDED BY MANUFACTURER.
PROVIDE DOUBLE SUCTION REFRIGERANT PIPING RISERS AND TRAPS AS RECOMMENDED BY MANUFACTURER. QUANTITY AND NOTE:
SERVED
AREA
CFM
TYPE
UNIT
DUCTLESS SPLIT SYSTEM AIR CONDITIONING UNIT SCHEDULE
COOLING
TOTAL MBH
MIN AMPACITY
INDOOR
ELECTRICAL CHARACTERISTICS
MFS MIN AMPACITY
OUTDOOR
MFS
MANUFACTURER / MODEL
- - - - - - - -
-
-
-
-
-
-
-
-
-
-
- - -
- - -
DESIG LOCATION MOUNTING KW BTU / HR VOLTS PHASE CFM
EAT LAT
MANUFACTURER / MODEL
UH-1 CEILING HUNG - - - - - - - -
UH-2 - - - - - - - -
UH-3 - - - - - - - -
UH-4 - - - - - - - -
UH-5 - - - - - - - -
UNIT HEATER SCHEDULE
UH-5A
UH-6 - - - - - - - -
UH-6A - - - - - - - -
UH-7A - - - - - - - -
- - - - - - - -
EMERGENCY ELECTRICAL
ELECTRICAL SERVICE
WATER SERVICE
UNISEX
UNISEX
FIRE PROTECTION
BULK FLUID STOAGE
FIRE PROTECTION
UH-7B - - - - - - - -
UH-8 - - - - - - - -
UH-9 - - - - - - - -
UH-10 - - - - - - - -
UH-11 - - - - - - - -
UH-12 - - - - - - - -
UH-13 - - - - - - - -
ELECTRI CAL
CLEANING SUPPLY STORAGE
EF-2 - - -
EF-3 - - -
EF-4 - - -
EF-5 - - -
UNISEX - - -
- - - - - - - - - - COMPRESSOR RM - - -
- - - - - - - - - - EF-8
ELECTRICAL ROOM
EMERGENCY
- - -
- - - - - - - - - - EF-7 - - -
- - - - - - - - - - EF-6 - - -
STORAGE
CLEANING SUPPLY
STORAGE
BULK FLUID
ELEVATOR
ROOM
ELECT SERVICE
HEATING
TOTAL MBH
LOCATION
PLANNING OFFICE
BREAK ROOM
CLEANING
NOT USED
EF-9
EF-10
EF-11
EF-12
EF-13
- - - - - - - -
OFFICE
MOWFOREMAN
- - - - - - - - OFFICE
-
-
-
-
-
- - - - - - - -
CONTROL
OPERATION
-
- - - - - - - - -
- - - - - - - - -
- - - - - - - -
- - - - - - - -
-
- - - - - - - -
UH-14
UH-15
UH-16
UNIT
INDOOR
UNIT
OUTDOOR
DESIGNATION
ROOF
ON
AC-1
AC-2
AC-3
AC-4
AC-5
AC-6
AC-7
- - - - - - - - - - - - -
- - - - - - - - -
- - - - - - - - -
-
-
- - -
- - -
- - - - - - - - -
- - - - - - - - -
-
-
-
-
-
-
-
-
-
-
- -
- -
- -
- -
- -
-
-
-
-
-
-
-
-
-
-
AC-8
AC-9
AC-10
EQUIPMENT
ROOF
ON
ROOF
ON
ROOF
ON
ROOF
ON
ROOF
ON
QUIET ROOM
QUIET ROOM
-
-
-
-
-
-
-
-
-
-
-
-
-
ELECTRICAL RM
LR MAINTENANCE STORAGE
UNISEX
COMPRESSOR
WASH BUILDING
CEILING HUNG
CEILING HUNG
CEILING HUNG
CEILING HUNG
CEILING HUNG
CEILING HUNG
CEILING HUNG
CEILING HUNG
CEILING HUNG
CEILING HUNG
CEILING HUNG
CEILING HUNG
NOT USED
CEILING HUNG
CEILING HUNG
CEILING HUNG
NOT USED
NOT USED
-
-
-
-
-
WASH BUILDING
WASH BUILDING
UNISEX TOILET
UNISEX TOILET
NOT USED
NOT USED
AC-11 IT ROOM
ROOF
ON
ROOF
ON
ROOF
ON
ROOF
ON
EQUIPMENT
MECHANICAL SCHEDULES AND DETAILS
DECEMBER 2013
VH
GK
VH

ME-L81
125 NONE
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
PAULCO
Engineering, Inc.
Columbia, MD
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION
ABBREVIATIONS ABBREVIATIONS (CONTINUED) LEGEND
DESCRIPTION SYMBOL
CD
BFP
GENERAL NOTES
A
AF
DO
MO
CG
WW
N
ATF
SW
HWR
SSW
TW
,
NOTE: ALL THE SYMBOLS AND ABBREVIATIONS INDICATED HERE MAY NOT APPEAR ON THE CONTRACT DRAWINGS.
,
X
WAF
GAS WATER HEATER GWH
GALLONS PER MINUTE GPM
GALLONS PER HOUR GPH
GALVANIZED GALV
GALLON GAL
GAUGE GA
GAS G
FLOOR SINK FSK
FLOWSWITCH FS
FIRE STAND PIPE FSP
FEET FT OR '
FEET PER SECOND FPS
FEET PER MINUTE FPM
FLOOR FLR
FLEXIBLE FLEX
FIRE HOSE CABINET FHC
FINISHED FLOOR FF
FOUNDATION DRAIN TILE FDT
FLOOR DRAIN FD
FLOOR CLEAN OUT FCO
FAHRENHEIT F
EXISTING EX
ENTERING WATER TEMPERATURE EWT
ELECTRICAL WATER HEATER EWH
ELECTRICAL WATER COOLER EWC
EXPANSION TANK OR EXTERIOR EXT
EXPANSION EXP
EXISTING TO REMAIN ETR
ELEVATION ELEV
ELECTRICAL ELEC
DOMESTIC WATER HEATER DWH
DRAWING DWG
DOWNSPOUT DS
DOWN DN
DIAMETER DIA
DRINKING FOUNTAIN DF
DEGREE DEG
DRY BULB DB
CONNECT TO EXISTING CX
CHASSIS WASH
COLD WATER (DOMESTIC) OR CW
CONTINUATION CONT
CONNECTION CONN
CONCRETE CONC
CLEAN OUR CO
CEILING CLG
CENTER LINE CL
CAST IRON CI
CUBIC FEET CFT
CUBIC FEET PER MINUTE CFM
CONDENSATE DRAIN CD
COMPRESSED AIR STATION CAS
COMPRESSED AIR CA
COMMON C
FLOWMETER FITTING
BALANCING & SHUT OFF VALVE WITH BVF
BALANCING & SHUT OFF VALVE BV
BELOW BLW
BUILDING BLDG
BRAKE HORSE POWER BHP
BACK FLOWPREVENTER BFP
BOTTOM ELEVATION BE
BACK DRAFT DAMPER BDD
BALANCE BAL
ARCHITECTURAL ARCH
APPROXIMATE APPROX
AIR MEASURING DEVICE/STATION AMD
AIR HANDLING UNIT AHU
ABOVE FINISHED FLOOR AFF
AREA DRAIN ADR
ACCESS DOOR OR AREA DRAIN AD
AIR COOLED CONDENSING UNIT ACCU
AIR CONDITIONING AC
ABANDON ABAN
AUTOMATIC AIR VENT AAV
FOR ALL THE PLUMBING WORK TO THE OWNER.
CONTRACTOR SHALL FURNISH "AS-BUILT" RECORD DRAWINGS
AT THE COMPLETION OF THE PROJECT THE PLUMBING PGN-13
TO THE FULL SATISFACTION OF THE OWNER.
CHARACTERISTICS, AS WELL AS WARRANTY CERTIFICATION,
QUALITY, DIMENSIONAL LIMITATIONS AND PERFORMANCE
IS RESPONSIBLE FOR PROVIDING THE SAME LEVEL OF
MAY BE OFFERED FOR APPROVAL. HOWEVER, THE CONTRACTOR
CHARACTERISTICS. PRODUCTS OF OTHER MANUFACTURERS
QUALITY, DIMENSIONAL LIMITATIONS, AND PERFORMANCE
MAKE AND MODEL NUMBER TO ESTABLISH A LEVEL OF
PLUMBING FIXTURES AND EQUIPMENT ARE SPECIFIED BY PGN-12
INSULATION TO MINIMUM 1" THICK.
WHERE WATER PIPING DROPS IN EXTERIOR WALLS, INCREASE PGN-11
WORK, AT NO ADDITIONAL COST TO THE OWNER.
APPROVED BY OWNER, SHALL BE PROVIDED TO COMPLETE THE
EQUIPMENT LOCATIONS OR OTHER JOB CONDITIONS AND AS
OFFSETS AS REQUIRED BY VERTICAL AND HORIZONTAL
WORK. ADDITIONAL BENDS, VERTICAL AND HORIZONTAL
THAT MAY BE REQUIRED FOR PROPER INSTALLATION OF THE
OFFSETS, BENDS, ELBOWS, OR OTHER SPECIFIC ELEMENTS
DRAWINGS ARE DIAGRAMMATIC AND DO NOT SHOWALL PGN-10
WHERE SHOWN ON PLANS/RISERS.
WATER PIPING AS REQUIRED PER PDI GUIDELINES AND
PROVIDE WATER HAMMER ARRESTORS/SHOCK ABSORBERS IN PGN-9
MODIFICATIONS.
ALLOWANCE OF 50 FEET OF 4" STORM WATER PIPING
DUCTWORK, ETC. PLUMBING CONTRACTOR SHALL INCLUDE AN
SHALL BE MODIFIED AS REQUIRED, TO ACCOMMODATE
PROVIDED WITH SLOPE OF MINIMUM 1/4" PER FOOT, AND
NEWRAIN LEADERS/STORM WATER PIPING SHALL BE PGN-8
OR STRUCTURAL WORK.
INCREASED IN COORDINATION WITH OTHER PIPING, DUCTS,
OF 1/8" PER FOOT. WHERE POSSIBLE, THE SLOPE SHALL BE
NEWSANITARY DRAIN PIPING SHALL HAVE A MINIMUM SLOPE PGN-7
CONSTRUCTION.
FOR BUILDING WALL, CEILING, FLOOR AND ROOF
REFER TO ARCHITECTURAL AND/OR STRUCTURAL DRAWINGS PGN-6
DETAILS FOR OPENINGS AND PENETRATIONS.
SPECIFICATIONS. COORDINATE WITH ARCHITECTURAL
DONE IN STRICT ACCORDANCE WITH PROJECT
ALL CUTTING AND PATCHING, WHERE REQUIRED, SHALL BE PGN-5
FIXTURES, ELECTRICAL PANELS, ETC.
DRAWINGS FOR TYPES OF CEILINGS, CONDUITS, LIGHTING
COORDINATE WITH ARCHITECTURAL AND ELECTRICAL PGN-4
MINIMUM ACCESS DOOR SIZE SHALL BE 18" X 18".
FULL ACCESSIBILITY TO VALVES, DAMPERS, FILTERS, ETC.
AND CEILINGS SHALL BE SIZED AS REQUIRED TO PERMIT
UNLESS NOTED OTHERWISE, THE ACCESS DOORS IN WALLS PGN-3
THE EXTENT WHERE SHOWN ON PLANS.
CONSTRUCTION. ACCESS DOORS/PANELS ARE NOT LIMITED TO
ARCHITECTURAL DRAWINGS FOR EXTENT AND TYPE OF WALLS
BEHIND DRYWALL, PLASTER OR MASONRY WALLS. REFER TO
PROVIDE ACCESS DOORS TO SERVICE DAMPERS, VALVES, ETC PGN-2
TO THE EXTENT WHERE INDICATED ON PLANS.
CONSTRUCTION. ACCESS DOORS/ PANELS ARE NOT LIMITED
DRAWINGS FOR EXTENT AND TYPE OF CEILING
INACCESSIBLE CEILINGS. REFER TO ARCHITECTURAL
VALVES, EQUIPMENT ABOVE PLASTER, DRYWALL, AND/OR
PROVIDE ACCESS DOORS TO SERVICE DAMPERS, OPERATORS, PGN-1
[XXX]
[XXX]
BALANCING VALVE/CIRCUIT SETTER
ROOM NUMBER
DRAWING KEY NOTE
PIPE REDUCER
PIPE INCREASER
FLEX PIPE
UNION
PIPE ELBOWTURNED DOWN
PIPE ELBOWTURNED UP
VALVE IN VERTICAL
CHECK VALVE
CAP OR PLUG PIPE END
BALL/GATE/GLOBE SHUT-OFF VALVE
BACK FLOWPREVENTER ASSEMBLY
AREA DRAIN
[TRIBUTARY ROOF AREA IN S.F.]
ROOF DRAIN
FLOOR DRAIN
FLOOR CLEAN OUT
CLEAN OUT, WALL CLEAN OUT
NITROGEN PIPING
WASTE ANTIFREEZE FLUID PIPING
WINDSHIELD WASHER FLUID
CHASSIS GREASE PIPING
AUTOMATIC TRANSMISSION FLUID PIPING
MOTOR OIL PIPING
DIFFERENTIAL OIL PIPING
ANTI-FREEZE PIPING
COMPRESSED AIR PIPING
CONDENSATE PIPING
NATURAL GAS PIPING
[TRIBUTARY ROOF AREA IN S.F.]
SECONDARY (OVERFLOW) STORM WATER PIPING
[TRIBUTARY ROOF AREA IN S.F.]
STORM WATER PIPING
STORM WATER DRAINAGE PIPING
VENT PIPING
SANITARY/WASTE DRAINAGE PIPING
TEMPERED WATER PIPING - DOMESTIC
HOT WATER PIPING - RECIRCULATING
HOT WATER PIPING - DOMESTIC
COLD WATER PIPING - DOMESTIC
[XXX]
XXXX
WASTE OIL BOILER WOB
WATER HYDRANT WH
WALL CLEAN OUT WCO
WET BULB WB
WITH W/
WIDTH W
VENT THROUGH ROOF VTR
CLEAN OUT IN VERTICAL PIPE VC OR VCO
VOLT V
UNDERGROUND SANDFILTER USF
TW
TRANSFER SWITCH TS
TYPICAL TYP
TRANSITION TRANS
TRAP PRIMING LINE TP OR TPL
TRAP PRIMER PANEL TPP
STORM WATER SW
SECONDARY (OVERFLOW) STORM WATER SSW
SECONDARY (OVERFLOW) RAIN LEADER SRL
SECONDARY (OVERFLOW) ROOF DRAIN SRD
STAINLESS STEEL SS
SQUARE FEET SQFT
SPRINKLER SPKR
SUMP PUMP DISCHARGE SPD
STATIC PRESSURE SP
SHOCK ABSORBER SHK
SQUARE FEET SF
STORM DRAIN SD
SCHEDULE SCHD
SANITARY SAN
REDUCED PRESSURE BACK FLOWPREVENTER RPBFP
REMOVE EXISTING RX
RAIN LEADER RL
REQUIRED REQD
RECTANGULAR RECT
ROOF DRAIN RD
PRESSURE WASH WATER SUPPLY PWW
POUNDS PER SQUARE INCH PSI
PRESSURE PRES
PHASE PH
PRESSURE DROP PD
OIL/WATER PUMP OWP
ON CENTER OC
NOT TO SCALE NTS
NUMBER NO. OR #
NORMALLY OPEN NO
NOT IN CONTRACT NIC
NORMALLY CLOSED NC
MANHOLE MH
MANUAL AIR VENT MAV
LENGTH L
INVERT ELEVATION INV
INCH IN OR "
INSULATED METAL CASING IMC
HERTZ HZ
HOT WATER RECIRCULATING HWR OR HWC
HOT WATER MIXING VALVE HWMV
HW
HOT WATER SUPPLY HS
HOT WATER RETURN HR
HORSE POWER HP
HOSE END DRAIN HED
HEADER HDR
HOSE BIBB HB
HEIGHT H
GENERAL NOTES AND ABBREVIATIONS
DECEMBER 2013
VH
GK
VH

PL-L01
126 NONE
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
PAULCO
Engineering, Inc.
Columbia, MD
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
0
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
1
A
B
C
D
15 15.1 2 3 4 5 6 8 9 10 14 13 12 11 7 7.1 23 23.1 16 17 18 19 20 21 22 24 25 26 27
C
A
C
A
N
SCALE:
YARD LEVEL COMPOSITE PLAN
1" = 30'
30' 30' 0 60'
SCALE:1"=30'
CIVIL DRAWINGS
BELOWGRADE, REFER TO
BUILDING. FOR CONTINUATION
SANITARY/CWUP TO S
YARD LEVEL COMPOSITE PLAN - PLUMBING
DECEMBER 2013
VH
GK
VH

PL-L05
127 1"=30'
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
SUPPLY STORAGE CLEANING STORAGE BULK FLUID
CORRIDOR
BREAK ROOM
CLEANING
E-3
SERVICE WATER SERVICE ELECTRICAL SERVICE ELECTRICAL
EMERGENCY
100
T.R. UNISEX
101
ROOM BREAK L.R.
102
OFFICE L.R.
103
STORAGE L.R. MAINT.
104
105
ELEC.
106 107
PROTECT.
FIRE
108
PROTECT.
FIRE
111
109
T.R. UNISEX 110
T.R. UNISEX
112
113
OFFICE CLEANING
S2
S2-1 STAIR
114
ELEV.
115 116
117
WASH BAY
118
ELEC.
119
COMM. CL.
120
PROTECT. FIRE
121
ROOM
COMPRESSOR
1
1
PL-L10
PL-L12
PAULCO
Engineering, Inc.
Columbia, MD
CD
CD
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
1
0
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
8' 8' 0 16'
SCALE:"=1'-0"
N

"=1'-0"
1
PL-L10 SCALE:
REF: PL-L05
YARD LEVEL FLOOR PLAN - PLUMBING
YARD LEVEL FLOOR PLAN - PLUMBING
DECEMBER 2013
VH
GK
VH

PL-L10
128 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
CA SYSTEM
STANDBY
AIR DRYER
W/ RECEIVER &
COMPRESSOR
DUPLEX ROTARY
P-3
P-1
P-6
FD
FD
AC-4
AC-3
P-7
CO
CHECK VALVE
BACKWATER
ABOVE PARKING LOT LEVEL
DISCHARGE 10FT
V UP,
DRAWINGS FOR CONTINUATION
SW, REFER TO CIVIL
FD
ELECTRIC HWHEATER
30 GALLON
SHOP ROOMS
TO "WEST" YARD
REFER TO YARD LEVEL DRAWING FOR CONTINUATION
CA TO TRAIN YARD & TRAIN WASH BUILDING,
FOR CONTINUATION
TO CIVIL DRAWINGS
4"SAN, REFER
SUPPLY STORAGE
CLEANING
STORAGE
BULK FLUID
100
T.R.
UNISEX
101
ROOM
BREAK
L.R.
102
OFFICE
L.R.
103
STORAGE
L.R. MAINT.
104
105
ELEC.
106
107
PROTECT.
FIRE
121
ROOM
COMPRESSOR
M
A
T
C
H

L
I
N
E
FD
FD
P-3
P-3
P-1
P-1 FD
P-7
FD
P-8
ABOVE PARKING LOT LEVEL
DISCHARGE 10FT
V UP,
P-6
ELECTRIC HWHEATER
30 GALLON
VTR
FD
SHOP BUILDING
TO WEST YARD
CW (HEAT TRACED)
AC-2
AC-1
DRAWINGS FOR CONTINUATION
SW, REFER TO CIVIL CHECK VALVE
BACKWATER
DRAWINGS FOR CONTINUATION
4"SAN, REFER TO CIVIL
TO SW
OIL-MONITORING/ALARM PANEL
W/ PROBES AND
AUTO ON-OFF FLOAT SWITCH
SUMP PUMP PIT/PUMP W/
G UP
CWUP
RFBFP
W/TS
OSY
WATER/FIRE SERVICE
INCOMING COMBINED
WASHINGTON GAS
GAS METER BY
FOR CONTINUATION
REFER TO CIVIL DRAWINGS
CORRIDOR
BREAK ROOM
CLEANING
E-3
SERVICE
WATER
SERVICE
ELECTRICAL
SERVICE
ELECTRICAL
EMERGENCY
108
PROTECT.
FIRE
111
109
T.R.
UNISEX 110
T.R.
UNISEX
112
113
OFFICE
CLEANING
S2
S2-1
STAIR
114
ELEV.
115 116
PROTECT.
FIRE
T.R.
UNISEX
T.R.
UNISEX
CORRIDOR
M
A
T
C
H

L
I
N
E
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
PAULCO
Engineering, Inc.
Columbia, MD
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
1
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SAN SAN SAN
8' 8' 0 16'
SCALE:"=1'-0"
N

"=1'-0"
1
PL-L12 SCALE:
REF: PL-L05
WASH BUILDING FLOOR PLAN - PLUMBING
WASH BLDG FLOOR PLAN - PLUMBING
DECEMBER 2013
VH
GK
VH

PL-L12
129 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
KEY PLAN
CO
CO CO CO
DRAWING FOR CONTINUATION
REFER TO YARD LEVEL
& CA DROPS
CA TO EQUIPMENT
W/ VACUUM BREAKER
3/4" HOSE BIBB
BELOWSLAB
PIPING LOCATED
BELOWSLAB
PIPING LOCATED
& CWDROPS
CWTO EQUIPMENT DN
CW
FOR CONTINUATION
TO CIVIL DRAWINGS
INTERCEPTOR, REFER
SAN TO SAND/OIL
FOR CONTINUATION
REFER TO CIVIL DRAWINGS
CW TO WASH BUILDING,
117
118 119
TR3
TR2
TR1
TR1
S
A
N
G
S
A
N
G
S
A
N
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
1
3
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PAULCO
Engineering, Inc.
Columbia, MD
KEY PLAN
UP
SW
P-1A P-3 FD
P-7
FD
STATION
PRIMING
TRAP
G UP
P-1A
P-3
SW
TO RD
SW UP
S
W
TO RD
SW UP
P-6
DN
SW
UP
SW
DN
SW
CW UP
HW &
HWR,
G DN
CW DN
226 214
214A
213
211
212
224
225
209
210
204
208
207
206
205
200
202
216
217
220
221
222
218 219
223
215
E-3
203
201
LOBBY
S2-3
STAIR
ROOM
TEAM
VEST.
ELEV.
I.T.
CORR.
MASTER
YARD
ROOM
INCIDENT
CORR.
CORR.
CORR.
S2
SUPER.
TRANS.
COPY
ADMIN./
SUPER.
TRANS.
ASST.
COORD.
WORK BLK
CORR.
ROOM
TEAM
T.R.
UNISEX
ELEC.
MECH.
EQUIP.
LOST/FND
DISPATCH
CONTROL CNTR
OPERATIONS
SUPER.
T.R.
UNISEX
OFFICE
EQUIP.
TECH.
238
MACHINE CL
ELEVATOR
MATCH LINE
P-6
FD
P-1A
P-1
FD
FD
FD
P-2A
P-2
P-3A
P-3A
P-3A
P-3A
P-1
P-1
P-1
P-1A
P-6
P-4
P-8
V UP
P-1A
FD
P-6
P-3A
UP
SW
STATION
PRIMING
TRAP
VALVE
BALANCING
TO RD
SWUP
CO
CWDN
237
236
234
232
233
235
S3
228
227
229
226 214
231
214A
230
213
203
CORR.
CORR.
S3-1
STAIR
VEST.
EQUIP.
LOST/FND
DISPATCH EQUIP.
ROOM
QUIET
T.R.
UNISEX
CORR.
T.R.
WOMENS
T.R.
MENS
LOCKERS
JAN. CL.
MAINT.
BLDG.
KITCHENETTE
OPER. BRK RM/
MATCH LINE
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
N
8' 8' 0 16'
SCALE: 1/8"=1'-0"
ASSOCAITED WITH FIXTURES ON FIRST FLOOR.
A. REFER TO YARD LEVEL PLUMBING DRAWING, FOR SANITARY PIPING
DRAWING NOTE:

"=1'-0"
1
PL-L13
OFFICE FIRST FLOOR PLAN - PLUMBING
SCALE:
OFFICE FIRST FLOOR PLAN - PLUMBING
DECEMBER 2013
VH
GK
VH

PL-L13
130 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
PAULCO
Engineering, Inc.
Columbia, MD
G
24 25 26 27
AA
A
B
A.3
A.4
A.8
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
1
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
24 25 26 27 24 25 26 27
C
B.6
B.8
C.8
B.5
N
8' 8' 0 16'
SCALE:"=1'-0"
SCALE:

"=1'-0"
1
PL-L14
OFFICE SECOND FLOOR PLAN - PLUMBING
OFFICE SECOND FLOOR PLAN - PLUMBING
DECEMBER 2013
VH
GK
VH

PL-L14
131 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
316
313
310
312
307
302
306
305
303
311
301
308
S2
304
300
309
E-3
S2-4
STAIR
ELEV.
CONF.
CORR.
CORR.
CORR.
LOBBY
ELEV.
COPY
ADMIN./
CORR.
I.T.
DIRECTOR
L.R. DEP.
DIR.
L.R.
T.R.
UNISEX
ELEC.
ROOM
INCIDENT
ROOM
COMM.
MECH.
T.R.
UNISEX
T.R.
UNISEX
P-3A
P-6
P-1A
HWG-1
SWDN
TO RD
SW UP
& CWDN
G, HWR, HW,
FD
FD
HOUSEKEEPING PAD
4" HIGH
TYPE, DIRECT VENTED WATER HEATER
50 GALLON GAS-FIRED, CONDENSING
TO RD
SWUP
SWDN
P-7
MATCH LINE
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
S3
321
320
317
319 318
314
315
316
CORR.
CORR.
T.R.
UNISEX
T.R.
UNISEX
JAN. CL. STOR.
CLASSROOM
OFFICE
TRAIN.
S3-2
STAIR
TYPE, DIRECT VENTED WATER HEATER
50 GALLON GAS-FIRED, CONDENSING
V DN
VTR,
P-3A
P-6
P-1A
P-1A P-3
P-4
TO RD
SW UP
SWDN
TO RD
SW UP
FD
MATCH LINE
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
1
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PAULCO
Engineering, Inc.
Columbia, MD
KEY PLAN
4"RD
4"RD
4"RD
4"RD
DRAWINGS
ARCHITECTURAL
REFER TO
SWOVERFLOW,
SCUPPER FOR
4"VTR
MATCH LINE
4"RD 4"RD
4"RD
4"RD
MATCH LINE
REFER TO ARCHITECTURAL DRAWINGS
SCUPPER FOR SWOVERFLOW,
S2
S2-5
STAIR
DN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
N
8' 8' 0 16'
SCALE:"=1'-0"
SCALE:
OFFICE ROOF PLAN
"=1'-0"
SCALE: "=1'-0"
OFFICE ROOF STAIR PLAN
TO ARCHITECTURAL DRAWINGS
SCUPPER FOR SWOVERFLOW. REFER
OFFICE ROOF PLAN - PLUMBING
DECEMBER 2013
VH
GK
VH

PL-L15
132 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
24 25 26 27
AA
A
B
A.3
A.4
A.8
S
A
N
S
W
SAN
S
A
N
C
B.6
B.8
C.8
B.5
SAN
S
A
N
S
A
N
S
W
S
A
N
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
1
6
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PAULCO
Engineering, Inc.
Columbia, MD
KEY PLAN
UP
SW
CO
226 214
213
211
212
224
225
209
210
204
208
207
206
205
200
202
216
217
220
221
222
218 219
223
215
E-3
203
201
LOBBY
S2-3
STAIR
ROOM
TEAM
VEST.
ELEV.
I.T.
CORR.
MASTER
YARD
ROOM
INCIDENT
CORR.
CORR.
CORR.
S2
SUPER.
TRANS.
COPY
ADMIN./
SUPER.
TRANS.
ASST.
COORD.
WORK BLK
CORR.
ROOM
TEAM
T.R.
UNISEX
ELEC.
MECH.
EQUIP.
LOST/FND
DISPATCH
CONTROL CNTR
OPERATIONS
SUPER.
T.R.
UNISEX
OFFICE
EQUIP.
TECH.
238
MACHINE CL
ELEVATOR
CO
CO
CO
FOR CONTINUATION
TO CIVIL DRAWINGS
SLAB/GRADE, REFER
BELOW YARD LEVEL
CW UP & DN TO
FOR CONTINUATION
TO CIVIL DRAWINGS
SLAB/GRADE, REFER
BELOW YARD LEVEL
SW UP & DN TO
FOR CONTINUATION
TO CIVIL DRAWINGS
SLAB/GRADE, REFER
YARD LEVEL
4"SAN DN TO BELOW
237
236
234
232
233
235
S3
228
227
229
226 214
231
214A
230
213
203
CORR.
CORR.
S3-1
STAIR
VEST.
EQUIP.
LOST/FND
DISPATCH EQUIP.
ROOM
QUIET
T.R.
UNISEX
CORR.
T.R.
WOMENS
T.R.
MENS
LOCKERS
JAN. CL.
MAINT.
BLDG.
KITCHENETTE
OPER. BRK RM/
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
N
8' 8' 0 16'
SCALE: 1/8"=1'-0"
TRAPS AND TRAP PRIMER PIPING.
ALL CW, SW, AND SANITARY PIPING SHALL BE HEAT TRACED INCLUDING
A. ALL PIPING SHOWN IS LOCATED BELOWFIRST FLOOR SLAB EXPOSED.
DRAWING NOTE:

"=1'-0"
1
PL-L16
OFFICE YARD LEVEL PLAN - PLUMBING
SCALE:

OFFICE YARD LEVEL PLAN - PLUMBING
DECEMBER 2013
VH
GK
VH

PL-L16
133 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
A A
13 21 22
26 25
B
A.8
B.6
PAULCO
Engineering, Inc.
Columbia, MD
SAN
SAN
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
5
0
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
SAN
S
A
N
SAN
SAN
4' 4' 0 8'
SCALE:"=1'-0"
SCALE:
REF:
1
SCALE:
REF:
2
SCALE:
REF:
3
SCALE:
REF:
4
SCALE:
REF:
5
" = 1'-0" " = 1'-0"
TOILET ROOM 221
" = 1'-0"
TOILET ROOM 210 TOILET ROOM 227
" = 1'-0" " = 1'-0"
TOILET ROOM 100 TOILET ROOMS 109 & 111
YARD LEVEL YARD LEVEL
FIRST FLOOR PLAN
FIRST FLOOR PLAN FIRST FLOOR PLAN
2' 2' 0 4'
SCALE:"=1'-0"
PL-L50 PL-L50
PL-L50 PL-L50
PL-L50
ENLARGED TOILET ROOM PLANS - PLUMBING
DECEMBER 2013
VH
GK
VH

PL-L50
134 AS SHOWN
LYTTONSVILLE YARD FACILITY
P-3A
P-6
P-1A
FD W/TP
SLAB
BELOW
CHASE
IN
CHASE
IN
V DN
SLAB
BELOW
SLAB
BELOW
V DN
SLAB
BELOW
SAN DN
CLG
ABOVE
CLG
ABOVE
CLG
ABOVE
P-3A SLAB
BELOW
P-6
P-1A
P-1A
P-3
FD W/TP
SLAB
BELOW
CO
V DN V DN
IN CHASE

CLG
ABOVE
CLG
ABOVE
CLG
ABOVE
SAN DN

T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
P-1A
P-3
SAN DN
SLAB
BELOW
CO IN CEILING


IN CHASE

P-1A
P-3 P-6
FD W/TP
SAN UP SLAB
BELOW
V DN

SAN DN
SLAB
BELOW
SLAB
BELOW
P-1A
P-1A
P-3A
SAN DN
FD W/TP
CEILING
ABOVE

V DN
CHASE
IN

SLAB
BELOW

V DN
C
25
25
24
24
B.8
C.8
A.3
A.4
B.5
B.6
PAULCO
Engineering, Inc.
Columbia, MD
S
A
N
SAN
HWR
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
5
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
5
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
S
W
S
A
N
SW
S
W
S
A
N
4' 4' 0 8'
SCALE:"=1'-0"
SCALE:
REF:
1
SCALE:
REF:
2
SCALE:
REF:
3
SCALE:
REF:
4
TOILET ROOM 233
" = 1'-0"
FIRST FLOOR PLAN
TOILET ROOM 234
" = 1'-0"
FIRST FLOOR PLAN
TOILET ROOM 303
" = 1'-0"
TOILET ROOM 313 & 314
" = 1'-0"
SECOND FLOOR PLAN
SECOND FLOOR PLAN
FOR SANITARY PIPING)
(REFER TO SECOND FLOOR
FOR SANITARY PIPING)
(REFER TO SECOND FLOOR
PL-L51
PL-L51
PL-L51
PL-L51
ENLARGED TOILET ROOM PLANS - PLUMBING
DECEMBER 2013
VH
GK
VH

PL-L51
135 3/8"=1'-0"
LYTTONSVILLE YARD FACILITY
P-6
P-1A
P-1
P-2A
P-2
P-3A
P-3A
P-4
V DN
BELOWSLAB
FD W/TP
FD W/TP
V DN
SAN DN
BELOWSLAB
BELOWSLAB
IN CHASE
IN CHASE


T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
P-3A
P-6
P-1A
P-1A
P-3
SWDN
FD W/TP
V DN
SAN DN
V DN
SAN DN
P-3A
P-6
P-1A
SWDN
FD W/TP
SAN DN
IN CHASE
V DN

P-3A
P-3A
P-1
P-1
P-1
P-1A
P-6
FD W/TP
V DN
V DN
BELOWSLAB
BELOWSLAB
FD W/TP
CO
CO
SAN DN
BELOWSLAB
V DN
BELOWSLAB
IN CHASE
CW
HW
V
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
9
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
P
l u
m
b
i n
g
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
P
L
L
A
8
0
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
PAULCO
Engineering, Inc.
Columbia, MD
PLUMBING FIXTURE SCHEDULE
P # DESCRIPTION CW REMARKS SAN VENT TRAP HW
P-1 1"
-
4" 2" INT. WATER CLOSET
P-1A
P-2A
P-3
P-3A
P-4
P-5
P-6
P-7
P-8
HB
2" FD
3" FD
4" FD
WATER CLOSET 1"
-
2" 4" INT. SEE NOTE No. 6
LAVATORY 1/2" 1 1/2" 'P'
LAVATORY SEE NOTE No. 4
1/2" 1 1/2"
1/2" 1/2" 1 1/2" 1 1/2" 'P'
INT. 2" 1 1/2"
-
3/4" URINAL
WATER COOLER 1/2" 1 1/2" 1 1/2" 'P'
-
COUNTERTOP SINK 1/2" 1/2" 1 1/2" 'P'
3/4" MOP BASIN 3/4" 3" 1 1/2" 'P'
-
1 1/4"
EYE WASH/SHOWER
EMERGENCY
1 1/2" 1 1/2" 'P'
HOSE BIBB 1/2"
- - - -
FLOOR DRAIN (3")
FLOOR DRAIN (4")
- -
- -
-
-
4"
3" 'P'
'P'
-
NOTES:
PROVIDE CAST IRON TRAP W/ CLEANOUT 8.
HANDICAPPED, WATER COOLER SPOUT SHALL BE 36" ABOVE FINISHED FLOOR 7.
HANDICAPPED, WALL HUNG 6.
WALL HUNG 5.
HANDICAPPED, COUNTERTOP MOUNTED 4.
COUNTERTOP MOUNTED 3.
HANDICAPPED, RIM OF FIXTURE SHALL BE 17" ABOVE FINISHED FLOOR 2.
FIXTURE PROVIDED UNDER ANOTHER DIVISION. UNDER THIS DIVISION, PROVIDE ROUGH-IN AND FINAL CONNECTION. 1.
SEE NOTE No. 6
SEE NOTE No. 6
SHOWER 2" 2" 'P' 1/2" 1/2"
FLOOR DRAIN (2")
- - -
2" 'P'
P-2 INT. 2" 1 1/2"
-
3/4" URINAL SEE NOTE No. 5
SEE NOTE No. 7
PLUMBING SCHEDULE
DECEMBER 2013
VH
GK
VH

PL-L80
136 NONE
LYTTONSVILLE YARD FACILITY
PURPLE LINE LIGHT RAIL
T-1042-0220
PRELIMINARY ENGINEERING
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
LSH
LTG
LO
LP
LT/FMC
LS
DISTRIBUTION PANEL
DRAWING
ABBREVIATIONS


60A - 3P 4#6 & 1#10 GND - 1"C
50A - 3P 4#6 & 1#10 GND - 1"C
40A - 3P 4#8 & 1#10 GND - 3 /4"C
30A - 3P 4#10 & 1#10 GND - 3 /4"C
20A - 3P 4#12 & 1#12 GND - 3 /4"C
CIRCUIT BREAKER CONDUCTOR
120/208 AND 277/480 VOLT, 3 PH, 4WCIRCUITS.
60A - 3P 3#6 & 1#10 GND - 1"C
50A - 3P 3#6 & 1#10 GND - 1"C
40A - 3P 3#8 & 1#10 GND - 3 /4"C
30A - 3P 3#10 & 1#10 GND - 3 /4"C
20A - 3P 3#12 & 1#12 GND - 3 /4"C
CIRCUIT BREAKER CONDUCTOR
208 OR 480 VOLT, 3 PH, 3W CIRCUITS.
60A - 2P 2#6 & 1#10 GND - 1"C
50A - 2P 2#6 & 1#10 GND - 1"C
40A - 2P 2#8 & 1#10 GND - 3 /4"C
30A - 2P 2#10 & 1#10 GND - 3 /4"C
20A - 2P 2#12 & 1#12 GND - 3 /4"C
CIRCUIT BREAKER CONDUCTOR
208 VOLT, 1 PH, 2W CIRCUITS.
60A - 1P 2#6 & 1#10 GND - 1"C
50A - 1P 2#6 & 1#10 GND - 1"C
40A - 1P 2#8 & 1#10 GND - 3 /4"C
30A - 1P 2#10 & 1#10 GND - 3 /4"C
20A - 1P 2#12 & 1#12 GND - 3 /4"C
CIRCUIT BREAKER CONDUCTOR
120 OR 277 VOLT, 1 PH, 2W CIRCUITS.

FEEDER/CONDUIT SCHEDULE
GENERAL NOTES
AIC
AIR HANDLING UNIT
AC
AMPERES A
AHU
AFG
AFF ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE HZ
ICCB
IDS
HPS
HTR
HV
IMC
KVA
HIGH PRESSURE SODIUM
HEATER
JB
KAIC
KV
MIN
MLO
MOD
MCC
MCP
MH
MO
MAIN LUGS ONLY
MINIMUM
MOUNTING HEIGHT
LEVEL SWITCH HIGH
METAL OXIDE
MOTOR OPERATED DAMPER
MOTOR CIRCUIT PROTECTOR
MULTI/CONDUCTOR
MAKE ALL FINAL CONNECTIONS
MOTOR CONTROL CENTER
MOLDED CASE CIRCUIT BREAKER
MAIN CIRCUIT BREAKER
INTRUSION DETECTION SYSTEM
INTERMEDIATE METALLIC CONDUIT
JUNCTION BOX
HIGH VOLTAGE
HERTZ
INSULATED CASE CIRCUIT BREAKER
KILOVOLT
LIMIT SWITCH
KILOVOLT AMPERE
LIGHTING
LOCKOUT
CC1
CKT
COMB
BFG
C
CB
CLG
CU
ALUMINUM
ANNUNCIATOR
CP
CPT
CT
ATC
ATS
AUTO
AL
ANNUN
AS
AUX
BFI
BKR
BLDG
AWG
BCSD
BFC
CEILING
CONTROL PANEL
CONTROL POWER TRANSFORMER
CIRCUIT BREAKER
CIRCUIT
COMBINATION
CURRENT TRANSFORMER
M/C
MCB
MCCB
COPPER
MAFC
AMMETER SWITCH
AUTOMATIC TEMPERATURE CONTROL
AMERICAN WIRE GAUGE
AUTOMATIC
AUXILIARY
AUTOMATIC TRANSFER SWITCH
BARE COPPER SOFT DRAWN
BUILDING
BREAKER
CONDUIT
BELOWFINISHED CEILING
BLOWN FUSE INDICATOR
BELOWFINISHED GRADE
CAPACITY
THOUSAND AMPERES INTERRUPTING
LIGHTING AND APPLIANCE PANEL
CABLE RUN NUMBER AS INDICATED.
POWER/CONTROL/INSTRUMENTATION
ALTERNATING CURRENT
(SYM, RMS AMPS)
AMPERES INTERRUPTING CAPACITY,
ELECTRIC MANHOLE
ELECTRIC METALLIC TUBING
ENCLOSURE
EXHAUST FAN
ELECTRIC HEATER
EMERGENCY
ELEVATION
EXISTING TO REMAIN
ELECTRIC UNIT HEATER
ELECTRIC WATER COOLER
ELECTRICALLY/OPERATED
EQUIPMENT
ELAPSED TIME METER
DIRECT CURRENT
OUTDOOR
DISCONNECT
CONNECT TO EXISTING
CLOSED CIRCUIT TELEVISION
DATA ACQUISITION SYSTEM
DOWN
EACH
EMPTY CONDUIT
ELEMENTARY CONTROL DIAGRAM
ELECTRIC WATER HEATER
FULL VOLTAGE REVERSING
GROUND
FLOWSWITCH
FUSED SAFETY SWITCH
FOOT OR FEET
GROUND FAULT PROTECTION
FULL VOLTAGE NON-REVERSING
HIGH INTENSITY DISCHARGE
HANDHOLE
HAND OFF AUTOMATIC
FRAME AMPS
FIRE ALARM
EXISTING
EXPLOSION PROOF
FUSE
FLOOR
FLEXIBLE
FLEXIBLE METAL CONDUIT
SEPARATE CONTRACT
FURNISHED BY OTHERS UNDER
FAN COIL UNIT
FEEDER
EMERG.
EMH
EMT
EF
EH
ELEV
ENCL
ETR
EUH
EWC
E/O
EQUIP
ETM
DC
O/D
DISC
CX
CCTV
DAS
DN
EA
EC
ECD
DP
DPC
DWG
EWH
FVNR
FVR
G
FS
FSS
FT
GFI
HID
HH
HOA
GFCI
GFGI
GFP
FA
FA
FAAP
EX, EXIST
EXP
F
FACP
FL
FLEX
FMC
FBO
FC
FDR
GROUND FAULT INTERRUPTER
INSTALLED
GOVERNMENT FURNISHED CONTRACTOR
INSTALLED
GOVERNMENT FURNISHED GOVERNMENT
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
HP HORSEPOWER
DISTRIBUTED PROCESS CONTROLLER
REMOTE CONTROL
POLYVINYL CHLORIDE
REQUIRED
RECEPTACLE
POTENTIAL TRANSFORMER
PANELBOARD
PROGRAMMABLE LOGIC CONTROLLER
PRESSURE SWITCH HIGH
PRESSURE SWITCH
REMOVE EXISTING
REDUCED VOLTAGE AUTOTRANSFORMER
SUPPLY FAN
SERVICE
REMOTE TERMINAL UNIT
ROOM
RIGID GALVANIZED STEEL
RESISTANCE TEMPERATURE DETECTOR
ROOT MEAN SQUARE
PILOT LIGHT
NATIONAL ELECTRICAL CODE
NEUTRAL
NON FUSED SAFETY SWITCH
NORMALLY OPEN
MOUNTING
MANUFACTURER'S ASSOCIATION
NATIONAL ELECTRICAL
MOUNTED
MOTOR STARTER PANEL
POLE OR POLES
OVERLOAD
PHASE
PUSH BUTTON
NOT TO SCALE
NORMALLY CLOSED
NUMBER
NIGHT LIGHT
NOT IN CONTRACT
OL
NL
NC
NIC
NTS
PH
PL
P
PB
MTG
N
MSP
MTD
NEC
NO
NO
NEMA
NFSS
PLC
RTD
RTU
RM
RMS
RVAT
SF
SG1-1A/P
RX
SER.
PSH
PT
PNL
PS
PVC
REQ'D
RGS
RC
RECEPT
INDICATED
SWGR NUMBER AND UNIT NUMBER AS
SWGR POWER WIRE RUN NUMBER -
CONDUIT
LIQUID TIGHT/FLEXIBLE METAL
UNIT HEATER
TYPICAL
UNDERGROUND
UNINTERRUPTIBLE POWER SUPPLY
UNLESS OTHERWISE NOTED
TIME DELAY OPEN
TIME DELAY CLOSE
TELEPHONE MANHOLE
TWISTED PAIR SHIELDED
TWISTED PAIR
CENTER LINE
TRANSFORMER
PHASE
NUMBER
AT
WEATHERPROOF
VARIABLE FREQUENCY DRIVE
VOLTS OR VOLTAGE
WATTS
WITH
WIRE
SHUNT TRIP
SAFETY SWITCH
STATION
STARTER
SHIELDED TWISTED PAIR
STAINLESS STEEL
SOUND POWERED PHONE SYSTEM
SPACE OR POLE NUMBER
TRIP AMPS
SYSTEM
TIME CLOCK
TIME DELAY ENERGIZED (ON)
TIME DELAY DE-ENERGIZED (OFF)
SYMMETRICAL
SOLID NEUTRAL
SHIELDED TWISTED TRIPLE
SWITCH
SWITCHGEAR
SWITCHBOARD
SWGR
SYM
SWBD
S/N
SW
SYS
TDE
TDC
TDD
TA
TC
SS
SS
SPPS
SIC
SOPN
ST
STR
STT
STPS
STA
STP
W
W/
W
V
VFD
WP

#
XFMR
@
TPS
TST
TP
TDO
TMH
TTB/TTC
UON
UPS
UG
TYP
UH
SHIELD
SHIELDED TWISTED PAIR OVER ALL
AUTO-TRANSFORMER STARTER
THERMOSTAT SWITCH IN
CURRENT
SYMMETRICAL INTERRUPTING
BOARD/CABINET
TELEPHONE TERMINAL
FOLLOWMETHODS UNDER UL LISTING.
20. SEAL ALL PENETRATION OF SMOKE AND FIRE RATED WALLS. PENETRATIONS ARE TO
EQUIPMENT GROUNDING CONDUCTORS, MAIN BONDING JUMPERS AS REQUIRED.
19. PROVIDE GROUNDING CONDUCTORS INCLUDING GROUNDING ELECTRODE CONDUCTOR,
18. INSTALL A NYLON OR POLYESTER PULL-LINE IN EACH CONDUIT AS APPROVED BY THE ENGINEER.
TO TOP OF THE DUCTBANK.
17. ALL TRACTION POWER CONDUIT DUCT BANKS IN THE VICINITY OF TRACK SHALL BE A MINIMUM OF 4'-4" FROM TOP OF RAIL
OTHERWISE NOTED.
16. ALL DUCT BANK CONDUITS SHALL BE ENCASED IN 3" OF CONCRETE WITH MINIMUM OF 2" CONDUIT SEPARATION UNLESS
C. CONDUITS SHALL BE SWABBED AND PROOFED BEFORE INSTALLATION OF CAP SEALS.
AS A SEAL.
CONDUIT OVER 1-1/2". FOR CONDUITS UNDER 1-1/2" USE HEAVY WALL SHRINK TUBING
CSB1-300-P1 CABLE SEALS RESPECTIVELY WITH BLANK. PRESSURE DISC OR EQUAL FOR
B. POSITIVE AND NEGATIVE TRACTION POWER CONDUITS USE. TYPE CSBE-300-P1 CABLE SEALS AND
A. NON- TRACTION POWER SERVICE CONDUITS, O-Z GEDNEY PUSH-PULL TAB CAPS TYPE PPC OE EQUAL.
15. CAP EACH CONDUIT STUB-UP TO PREVENT ANY FOREIGN MATERIAL FROM ENTERING INTO THE CONDUIT. CAP SHALL BE:
TO EXITING THE FLOOR OR WALL (EXCEPT TRACTION POWER SUPPLY).
14. ALL EMBEDDED PVC CONDUIT SHALL BE PROVIDED WITH PVC-GRS CONDUIT ADAPTERS TO TRANSITION TO GRS CONDUITS PRIOR
U.O.N. CONDUIT PLACEMENT IN STRUCTURE CONCRETE SHALL COMPLY WITH ACI 318 REQUIREMENT.
13. ALL EMBEDDED CONDUITS SHALL BE PVC SCHEDULE 40 IN CONCRETE UNDERGROUND DUCT BANKS OR OUTSIDE OF STRUCTURE WALLS.
ELEMENTS.
OF BENDS AND ELBOWS. EXPOSED CONDUIT AND CABLE RUNS SHALL BE RUN PARALLEL/ PERPENDICULAR TO BUILDING
12. CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY. RUN ALL CONDUITS USING SHORTEST AND MOST DIRECT PATH WITH A MINIMUM
11. USE MAXIMUM OF 6 FEET OF FLEXIBLE CONDUIT FOR MOTOR CONNECTIONS FOR VIBRATION ISOLATION.
10. MINIMUM CONDUIT SIZE SHALL BE 3/4" GALVANIZED RIGID STEEL TYPE, UNLESS OTHERWISE NOTED ON DRAWINGS.
RUNS 75 FEET AND LONGER.
EXCEPT FOR CONTROL WIRING WHICH SHALL BE A MINIMUM #14AWG. USE # 10 AWG MINIMUM FOR 12 VOLT BRANCH CIRCUIT
9. WIRING SHALL BE SINGLE COPPER INSULATED CONDUCTOR CABLE IN CONDUIT MINIMUM WIRE SIZE SHALL BE #12 AWG,
WIRING SHALL BE IN CONDUITS.
8. ALL WIRING INCLUDING FIRE ALARM, SECURITY, TELEPHONE/DATA, PUBLIC ADDRESS SYSTEM, AND HVAC CONTROLLER GENERAL
DRAWINGS OR PANEL SCHEDULES ADJUST FEEDER AND CIRCUIT BREAKER SIZES ACCORDINGLY.
7. IN THE EVENT THAT POWER REQUIREMENT FOR MECHANICAL EQUIPMENT DIFFERS FROM THAT SHOWN ON ELECTRICAL
OF BENDS WHERE CONDUITS CROSS THE BUILDING EXPANSION JOINTS, PROVIDE SPECIAL EXPANSION FITTINGS.
BY ENGINEER. PROVIDE ADDITIONAL JUNCTION BOXES OR PULL BOXES NOT SHOWN BUT REQUIRED BY CODE DUE TO NUMBER
6. PROVIDE CONNECTORS AND APPROPRIATE FITTINGS AT ALL LOCATIONS WHERE REQUIRED BY CODE AND/ OR REQUESTED
AVOID INTERFERENCE.
5. COORDINATE ELECTRICAL WORK INCLUDING LIGHTING FIXTURE LOCATIONS WITH ALL MECHANICAL PIPING AND DUCT WORK TO
ANY DAMAGE AS A RESULT OF THIS WORK.
THE PROPOSED WORK UNDER THE PROJECT. TAKE EVERY PRECAUTION TO PREVENT DAMAGE TO EXISTING WORK AND REPAIR
4. VERIFY EXACT LOCATION, SIZE, AND EXTENT OF ALL EXISTING OBSTRUCTIONS AND/OR CONDITIONS WHICH MAY AFFECT
WILL AFFECT THE CONTEMPLATED WORK.
3. EXAMINE THE SITE AND OBSERVE THE CONDITIONS OR OTHER CIRCUMSTANCES UNDER WHICH THE WORK WILL BE DONE WHICH
SHALL BE AT NO ADDITIONAL COST TO THE AUTHORITY.
MAY BE REQUIRED. FURNISHING SUCH FITTINGS AND ACCESSORIES AS MAY BE REQUIRED TO MEET SUCH CONDITIONS
THE SMALL SCALE OF THE DRAWINGS IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS AND ACCESSORIES WHICH
AND EQUIPMENT AT EACH LOCATION AS INDICATED. IN AS MUCH AS THE DRAWINGS ARE GENERALLY DIAGRAMMATIC BECAUSE OF
2. CAREFULLY EXAMINE ALL CONTRACT DRAWINGS/SPECIFICATIONS AND BE RESPONSIBLE FOR THE PROPER FITTING OF MATERIALS
REGULATIONS OF AUTHORITIES HAVING JURISDICTION OVER THE WORK.
1. ALL WORK SHALL COMPLY WITH THE LATEST NATIONAL ELECTRICAL CODE AND THE REQUIREMENTS OF ALL LOCAL CODES AND
GENERAL NOTES AND ABBREVIATIONS
DECEMBER 2013
MB
DP
LJ

EL-L01
137 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
GEC
PC
2
TS
200
225
VFD
SS
VFD
2
H
J J
E E
VAV
DWH
CUH
34
MOD
CP
TC
T7
S
SPD
ATS
12
E7.02
1
12
ACV
F
F
F
PS
FS
TS
H
FAAP
J
G
MH
HH
"A"
2 1
A
D
S
3
S
4
S
M
S
a
S
D
S
K
3S
3K
S
P
S
RC
S
OS OS
PP
OS
S
C
PC
F
FACP
F
BP
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
A
IG

FLUORESCENT LIGHTING FIXTURE. SEE LIGHTING FIXTURE SCHEDULE FOR FIXTURE TYPE.
LINEAR FLUORESCENT LIGHTING FIXTURE. SEE LIGHTING FIXTURE SCHEDULE

4 FT PYLON/BOLLART LIGHT
125V, 20A, DUPLEX RECEPTACLE WITH ISOLATED GROUND. ORANGE IN COLOR.
QUADRUPLEX RECEPTACLE, NEMA 5-20R, GROUNDING TYPE.
20A, 125VAC, SINGLE RECEPTACLE RATING AS INDICATED.
208V, 3 POLE, 4 WIRE, CIRCUIT BREAKING WELDING RECEPTACLE, RATING AS INDICATED.
480V, 3 POLE, 4 WIRE, CIRCUIT BREAKING WELDING RECEPTACLE,RATING AS INDICATED.
SPECIAL PURPOSE RECEPTACLE RECEPTACLE, SINGLE, RATING AS INDICATED.
VARIABLE FREQUENCY DRIVE, INDIVIDUALLY MOUNTED
SOLID STATE STARTER, INDIVIDUALLY MOUNTED
VARIABLE FREQUENCY DRIVE WITH BYPASS STARTER
ENCLOSED CIRCUIT BREAKER, SIZE AS INDICATED
SINGLE POLE SWITCH, 20A, 120-277V WITH PILOT LIGHT
PUSH BUTTON
LIGHTING CONTACTOR (X POLE) 277V
PHOTO CELL
MOTOR, NUMBER INDICATES HORSEPOWER
ELECTRIC UNIT HEATER
JUNCTION BOX
DOMESTIC WATER HEATER
EQUIPMENT CONNECTION AS NOTED
VARIABLE AIR VOLUME BOX
CABINET UNIT HEATER
SEE EQUIPMENT SCHEDULE ON DWG. E-XX FOR DETAIL.
SHOP EQUIPMENT, NUMERAL INDICATES EQUIPMENT NUMBER.
MOTOR OPERATED DAMPER
CONTROL PANEL
GROUNDING
EQUIPMENT CONNECTION
WIRING
MISCELLANEOUS
ELECTRICAL SYMBOLS LIST
LIGHTING
RECEPTACLES
SWITCHES
SAFETY SWITCHES / BREAKERS / STARTERS
TOGGLE SWITCH, SINGLE POLE 120 /277V, 20A, SWITCH MOUNTED 4'-0" AFF, U.O.N.
3-WAY SWITCH, 120/277V, 20A, MOUNTED 4'-0" AFF, U.O.N..
4-WAY SWITCH, 120/277V, 20A, SWITCH MOUNTED 4'-0" AFF, U.O.N.
TOGGLE SWITCH WITH OCCUPANCY SENSOR DUAL - TECHNOLOGY TYPE.
MANUAL MOTOR STARTER WITH MOTOR THERMAL OVERLOAD PROTECTION.
FIXTURES CONTROLLED
SINGLE POLE SWITCH, 20A, 120-277V, LOWER CASE SUBSCRIPT WHEN USED INDICATES
DIMMING BALLAST FOR THE FIXTURES INDICATED TO BE DIMMED
SINGLE POLE SWITCH, 20A, 120-277V, SUBSCRIPT D INDICATES DIMMER. PROVIDE
SINGLE POLE SWITCH, 20A, 120-277V, KEY OPERATED
THREE WAY SWITCH, 20A, 120-277V, KEY OPERATED
WITH CENTRAL NEUTRAL POSITION
THREE-WAY SWITCH 20A,120-277V REMOTE CONTROL-MOMENTARY CONTACT TOGGLE TYPE
HEIGHT AS NOTED.
125V, 20A, DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER MOUNTING
125V, 20A, DUPLEX RECEPTACLE, MOUNTED 1'-6" AFF, U.O.N.
POLES
NON-FUSED DISCONNECT SWITCH, SUBSCRIPT INDICATES AMPACITY AND NUMBER OF
MANUAL MOTOR STARTER SWITCH WITH OVERLOAD. PROVIDE HOA AS REQUIRED
STARTER UON. 60 = SWITCH SIZE AND 3 = NO. OF POLE. 30AMPS, 3 POLES UON
MAGNETIC MOTOR STARTER, SUBSCRIPT INDICATES NEMA SIZE 2, NEMA SIZE 1
STARTER UON
MAGNETIC MOTOR STARTER, SUBSCRIPT INDICATES NEMA SIZE 2, NEMA SIZE 1
POLES
FUSED DISCONNECT SWITCH, SUBSCRIPT INDICATES FUSED SIZE AND NUMBER OF
MOUNTING HEIGHT.
BLACK-LIT LED EXIST SIGN - WALL OR CEILING MOUNTED SEE PLAN NOTES FOR FIXTURE
SCHEDULE FOR FIXTURE MOUNTING HEIGHT AND TYPE.
FLUORESCENT LIGHTING FIXTURE - SURFACE OR PENDANT MOUNTED. SEE LIGHTING FIXTURE
PROTECTIVE RING, NEMA 4 ENCLOSURE MH 48" AFF.
EMERGENCY STOP PUSHBUTTON, MUSHROOM TYPE CAP WITH
24 HOUR ADJUSTABLE TIMER.
TRANSFORMER.
CIRCUIT BREAKER.
FUSE.
EXOTHERMIC WELD BONDING GROUND CONNECTION.
SYSTEM GROUND OR EQUIPMENT GROUND.
GROUNDING ROD.
GROUNDING ELECTRODE INSULATED CONDUCTOR. SIZE AS INDICATED.
GROUND BUS 1/ 4" THICK X 2" WIDE, LENGTH AS INDICATED ON PLANS.
24 HOUR ADJUSTABLE TIMER.

PHOTO ELECTRIC CONTROL.
POINT OF CONNECTION
CONDUIT OR CABLE TURNING UPWARD OR TOWARDS VIEWER.
CONDUIT OR CABLE TURNING AWAY OR DOWN.
CONDUIT CONCEALED IN FLOOR OR UNDERGROUND.
CONDUIT EXPOSED.
CONDUIT CONCEALED IN WALL OR CEILING.
SHOWN ON EACH SEPARATELY.
ARROWARE CONNECTED TO CIRCUIT NO. 2 UNLESS CIRCUIT NUMBER IS
ARROWAND NUMERAL 2 INDICATE THAT ALL DEVICES BEHIND


3/4" CONDUIT.
RUNS WITHOUT HATCH LINES INDICATE 2#12 + 1#12 GROUND IN
CIRCUITS. NUMBER OF HATCH LINES INDICATES NUMBER OF WIRES.HOME
HOMERUN TO PANEL. NUMBER OF ARROWHEADS INDICATES NUMBER OF
15
15
C
T T7
HANDHOLE
MANHOLE
HANDHOLE
CEILING/WALL MOUNTED OCCUPANCY SENSOR. PROVIDE POWER PACK AS REQUIRED.
LIGHTING POWER PACK
HOA
PLAN NOTES FOR FIXTURE MOUNTING.
CEILING/WALL MOUNTED COMPACT FLUORESCENT LIGHTING FIXTURE ON EMERGENCY CIRCUIT.SEE
FOR FIXTURE TYPE.
FLUORESCENT LIGHTING FIXTURE ON EMERGENCY CIRCUIT. SEE LIGHTING FIXTURE SCHEDULE
LIGHTING FIXTURE SCHEDULE FOR FIXTURE MOUNTING HEIGHT AND TYPE.
FLUORESCENT LIGHT FIXTURE ON EMERGENCY CIRCUIT - SURFACE OR PENDANT MOUNTED. SEE
AS FIXTURE TYPE ON THE PLANS. SEE PLANS NOTES FOR FIXTURE MOUNTING HEIGHT.
COMPACT FLUORESCENT LIGHTING FIXTURE - CEILING/WALL MOUNTED. LETTER "A" INDICATE
POLE LIGHTING. SEE LIGHTING FIXTURE SCHEDULE FOR POLE HEIGHT.
AIR TERMINAL
REVISION DESIGNATION.
KEYED SPECIFIC NOTE DESIGNATION.
SHEET WHERE DETAIL IS DRAWN.
DETAIL DESIGNATION.
DETAIL NUMBER.
FIRE ALARM SYSTEM
PANELBOARDS
FIRE ALARM ANNUNCIATOR PANEL (FAAP)
FIRE ALARM CONTROL PANEL (FACP)
FIRE ALARM SYSTEM DUCT SMOKE DETECTOR
FIRE ALARM SYSTEM HEAT DETECTOR. MOUNT ON CEILING (UON)
FIRE ALARM SYSTEM SMOKE DETECTOR. MOUNT ON CEILING (UON)
SPRINKLER SYSTEM AUTOMATIC CHECK VALVE
SPRINKLER SYSTEM TAMPER SWITCH
SPRINKLER SYSTEM FLOWSWITCH
SPRINKLER SYSTEM PRESSURE SWITCH
DENOTES THE CANDELA VALUE.
FIRE ALARM STROBE. MOUNT 7'-0" AFF (UON). THE SUBSCRIPT 15
FIRE ALARM, AUDIO/VISUAL CEILING MOUNTED
15 DENOTES THE CANDELA VALUE.
FIRE ALARM AUDIO/VISUAL. MOUNT 7'-0" AFF (UON). THE SUBSCRIPT
GROUND CONDUCTOR
DENOTES EXISTING TO BE REMOVED U.N.O.
SPECIFIC DUCTBANK SECTION DETAIL - SECTION SHOWN DASHED
SPARE DUCT (TYPICAL)
HEAVY LINE INDICATES BOTTOM OF DUCTBANK
EXISTING HANDHOLE
NEWCABLE DESIGNATION (TYPICAL) SEE CABLE SCHEDULE
DUCTBANK SECTION, LOOKING IN DIRECTION OF ARROWS
UNDERGROUND/SITE WORK
FIRE ALARM MANUAL PULL STATION, MOUNT 54" AFF.
60
3
2
3
60
15
2
3
SURGE PROTECTION DEVICE.
AUTOMATIC TRANSFER SWITCH
DEVICE OR EQUIPMENT INDICATED.
JUNCTION BOX CEILING/WALL MOUNTED WITH CONNECTION TO
NUMBER. RATING AS INDICATED ON DRAWING.
DRY-TYPE TRANSFORMER. LETTER "T7" INDICATES TRANSFORMER
APPLIANCE PANELBOARD FLUSH/SURFACE MOUNTED 120/208VAC.
DISTRIBUTION PANELBOARD FLUSH/SURFACE MOUNTED, 277/480VAC.
ELECTRICAL SYMBOL LIST
DECEMBER 2013
MB
DP
LJ

EL-L02
138 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
E
l e
c
t
r
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
E
L
L
A
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
40' 40' 0 80'
SCALE:1"=40'
SCALE: SCALE: 1" = 40'
SCALE: SCALE:
SHEET NOTES
TRANSFORMER - 6-WAY PVC CONCRETE ENCASED DUCTBANK DETAIL GENERATOR - 3-WAY PVC CONCRETE ENCASED DUCTBANK DETAIL
YARD LEVEL SITE PLAN - LIGHTING AND POWER
NOT TO SCALE NOT TO SCALE
22 1/2"
2
2

1
/
2
"
6
"

(
Y
T
P
)
6" (TYP)
4" SCHED 40 PVC (TYP)
2
2

1
/
2
"
22 1/2"
6
"

(
T
Y
P
)
6
"

(
T
Y
P
)
6" (TYP) 4" SCHED 40 PVC (TYP)
EL-E20.
FOR LIGHTING FIXTURES SCHEDULE, SEE SHEET D.
INDICATING THEIR VOLTAGE AND USAGE.
LABEL ALL JUNCTION BOXES AND PULL BOXES C.
OTHER EQUIPMENT.
CONDUIT INSTALLATION WITH TRACKS AND
COORDINATE ELECTRICAL LIGHT POLE AND B.
GENERAL NOTES.
ELECTRICAL ABBREVIATIONS, SYMBOLS AND
REFER TO DRAWING EL-E01 AND EL-E02 FOR A.
YARD LEVEL SITE PLAN - LIGHTING/POWER
DECEMBER 2013
MB
DP
MB

EL-L03
139 1"=40'
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
A
B
C
D
15.1 7.1 23.1
PAD
TRANSFORMER
GENERATOR PAD
SEE DETAIL IN THIS SHEET.
DUCTBANK FOR GENERATOR FEEDER.
25-FOOT POLE (TYPICAL)
TYPE P1 SITE LIGHTING WITH
THIS SHEET
SEE DETAILS
FEEDERS -
TRANSFORMER
DUCTBANK FOR
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
E
l e
c
t
r
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
E
L
L
A
0
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
SCALE:
YARD STORAGE PLAN - LIGHTING
1" = 30'
1
SHEET NOTES
SPECIFIC NOTES
FOR WIRING CONNECTION, SEE DETAIL X/ EL-E21
EL-E20.
FOR LIGHTING FIXTURES SCHEDULE, SEE SHEET E.
CONNECTIONS, SEE PANELBOARD SCHEDULES.
FOR NEWWIRING CONDUIT, AND FEEDER D.
INDICATING THEIR VOLTAGE AND USAGE.
LABEL ALL JUNCTION BOXES AND PULL BOXES C.
OTHER EQUIPMENT.
WORK, OVERHEAD PLUMBING PIPING, AND
CONDUIT INSTALLATION WITH MECHANICAL
COORDINATE ELECTRICAL EQUIPMENT AND B.
GENERAL NOTES.
ELECTRICAL ABBREVIATIONS, SYMBOLS AND
REFER TO DRAWING EL-E01 AND EL-E02 FOR A.
40' 40' 0 80'
SCALE:1"=40'
YARD STORAGE PLAN - LIGHTING
DECEMBER 2013
MB
DP
LJ

EL-L04
140 1"=30'
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
A
B
C
D
15.1 7.1 23.1
WASH BUILDING PLAN ENLARGED
REFER TO DRAWING EL-E09 FOR
EL-E05
1
EL-E09
1
(TYPICAL)
SUSPENDED FROM SLAB OVERHEAD
TYPE K LIGHTING FIXTURE
A
A
12 15.1 13 14 15 16 17 18 19 20
O
S
S
PP
PP S OS
S
O
S
S
S S
OS
PP S
OS
PP PP
PP
OS OS
OS
S
12 15.1 13 14 15 16 17 18 19 20
23.1 20 21 22 23 24 25 26 27
O
S
S
OS
S
OS
S
PP
O
S
S
OS
S
OS
S
O
S
S
PP
OS
OS
23.1 20 21 22 23 24 25 26 27
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
E
l e
c
t
r
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
E
L
L
A
0
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
1
2
SHEET NOTES
SPECIFIC NOTES
SCALE:
REF: EL-E04
"=1'-0"
1
EL-E05
YARD LEVEL PARTIAL FLOOR PLAN - LIGHTING
EL-E20.
FOR LIGHTING FIXTURES SCHEDULE, SEE SHEET E.
CONNECTIONS, SEE PANELBOARD SCHEDULES.
FOR NEWWIRING CONDUIT, AND FEEDER D.
INDICATING THEIR VOLTAGE AND USAGE.
LABEL ALL JUNCTION BOXES AND PULL BOXES C.
OTHER EQUIPMENT.
WORK, OVERHEAD PLUMBING PIPING, AND
CONDUIT INSTALLATION WITH MECHANICAL
COORDINATE ELECTRICAL EQUIPMENT AND B.
GENERAL NOTES.
ELECTRICAL ABBREVIATIONS, SYMBOLS AND
REFER TO DRAWING EL-E01 AND EL-E02 FOR A.
AND ACCESSIBLE.
PROVIDE JUNCTION BOX PANEL FOR LED DRIVER
FOR WIRING CONNECTION, SEE DETAIL X/ EL-E21
8' 8' 0 16'
SCALE:"=1'-0"
YARD LEVEL FLOOR PLAN - LIGHTING
DECEMBER 2013
MB
DP
LJ

EL-L05
141 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
LC1
FOR EXL2
CARTS
SANDING
EP1
EP1
100
T.R.
UNISEX
PROTECT.
FIRE
STORAGE
BULK FLUID
SUPPLY STORAGE
CLEANING
STORAGE
L.R. MAINT.
ROOM
BREAK
L.R.
OFFICE
L.R.
ROOM
COMPRESSOR
ELEC.
101
102
122 103 104 107 106
105







G3
B1
F1
F1
F1
G
G
C
C1
G1
F1
F (TYP)
B (TYP)
1 1 1 1
C
M
A
T
C
H

L
I
N
E
UP
S2-1
STAIR
OFFICE
CLEANING
BREAK ROOM
CLEANING
SERVICE
WATER
CORRIDOR
PROTECT.
FIRE
SERVICE
ELECTRICAL
SERVICE
ELECTRICAL
EMERGENCY
115
116
114 S2 113 112
108
111
110
T.R.
UNISEX
109
T.R.
UNISEX
ELEV.
E-3









F1
G3
G1
C1
C1
G1
G3
G3
B1
D1
D1
M
RECEPTACLE BELOW
CONNECT TO 120V
B (TYP)
F (TYP)
G (TYP)
C (TYP)
F1 (TYP)
1
M
A
T
C
H

L
I
N
E
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
0
6
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
SCALE:
PARKING DECK LEVEL PLAN - LIGHTING
1" = 30'
1
SHEET NOTES
SPECIFIC NOTES
N

FOR WIRING CONNECTION, SEE DETAIL X/ EL-E21
EL-E20.
FOR LIGHTING FIXTURES SCHEDULE, SEE SHEET E.
INDICATING THEIR VOLTAGE AND USAGE.
LABEL ALL JUNCTION BOXES AND PULL BOXES D.
OTHER EQUIPMENT.
CONDUIT INSTALLATION WITH STRUCTURE, AND
COORDINATE ELECTRICAL LIGHT POLE AND C.
GENERAL NOTES.
ELECTRICAL ABBREVIATIONS, SYMBOLS AND
REFER TO DRAWING EL-E01 AND EL-E02 FOR B.
FOUNDATION.
SQUARE POLE ON 3'-0" CONCRETE POLE
SHALL BE MOUNTED ON 15'-0" DARK BRONZE
DISTRIBUTION. THE LIGHTING FIXTURES
WITH ACCU LED OPTICS AND TYPE 4
VTS-B10-LED-E1-T4, WITH (10) 21 LED BARS
COOPER LIGHTING, CATALOG #
HEAD LED LIGHTING FIXTURE MANUFACTURED BY
THE PARKING AREA LIGHTING SHALL BE DUAL A.
30' 30' 0 60'
SCALE:1"=30'
PARKING DECK LEVEL PLAN - LIGHTING
DECEMBER 2013
MB
DP
LJ

EL-L06
142 1"=30'
LYTTONSVILLE YARD FACILITY
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
A
B
C
D
15.1 7.1 23.1
1
EL-E07
1
EL-E08
3 FOOT POLE FOUNDATION
W/15 FOOT POLE (TYPICAL) AND
TYPE P PARKING LOT LIGHTING
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
AA
A
B
C
A.3
A.4
A.8
B.6
B.8
B.5
24 25 26 27
O
S
S
PP P
P
S
OS
S
O
S
S
S
S
O
S
S
OS
S
O
S
S
O
S
S
OS
S
O
S
S
3
S
OS
S
3
S
OS
PP P
P
3
S
4
S
3
S
3
S
OS
S
O
S
S
3
S
OS
S
OS
S
OS
C
C.8
O
S
S
O
S
S
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
0
7
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
24 25 26 27
KEY PLAN
UP
DN
DN
UP
201
LOBBY
S2-3
STAIR
ROOM
TEAM
VEST.
ELEV.
I.T.
CORR.
MASTER
YARD
ROOM
INCIDENT
CORR.
CORR.
CORR.
CORR.
S2
S3-1
STAIR
SUPER.
TRANS.
COPY
ADMIN./
SUPER.
TRANS.
ASST.
COORD.
WORK BLK
CORR.
ROOM
TEAM
VEST.
T.R.
UNISEX
ELEC.
MECH.
EQUIP.
LOST/FND
DISPATCH
CONTROL CNTR
OPERATIONS
SUPER.
T.R.
UNISEX
OFFICE
TECH.
ROOM
QUIET
T.R.
UNISEX
CORR.
T.R.
WOMENS
233
S3
228
227
229
214
231
214A
230
213
211
212
224
225
209
210
204
208
207
206
205
200
202
216
217
220
221
222
218 219
223
215
E-3
203
EQUIP.
226

























D1
D1
L G3 G
G
G3
B1
(TYP)
TYPE B
A1
G3
G
C C
C C B1
G3 G3
A1
A1
G3
F1
F
F
F
F
F
F1
F1
1
L
G3
G
G1
G3
G
C
C
C D1 D1
G3
G3
G1 G1
C
B1
B1
G3
A1
A1
TYPE A (TYP)
(TYP)
TYPE G
G1
MATCH LINE
UP
LOCKERS
MAINT.
BLDG.
KITCHENETTE
OPER. BRK RM/
237 236
232
233
235

CL.
JAN.
T.R.
MENS
234



(TYP)
TYPE B
L
G
D1 D1
G1
G
G3
G
G3
G3
G1
G1
G1
G1
G1
G1
C
C
C
MATCH LINE
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
24'-0" 24'-0" 24'-0"
72'-0"
N
8' 8' 0 16'
SCALE: 1/8"=1'-0"
1
2
1
SHEET NOTES SPECIFIC NOTES
SCALE:
REF: EL-L06
"=1'-0"
1
EL-L07
OFFICE FIRST FLOOR PLAN - LIGHTING
EL-E20.
FOR LIGHTING FIXTURES SCHEDULE, SEE SHEET E.
CONNECTIONS, SEE PANELBOARD SCHEDULES.
FOR NEWWIRING CONDUIT, AND FEEDER D.
INDICATING THEIR VOLTAGE AND USAGE.
LABEL ALL JUNCTION BOXES AND PULL BOXES C.
OTHER EQUIPMENT.
WORK, OVERHEAD PLUMBING PIPING, AND
CONDUIT INSTALLATION WITH MECHANICAL
COORDINATE ELECTRICAL EQUIPMENT AND B.
GENERAL NOTES.
ELECTRICAL ABBREVIATIONS, SYMBOLS AND
REFER TO DRAWING EL-E01 AND EL-E02 FOR A.
NOT USED
FOR WIRING CONNECTION, SEE DETAIL X/ EL-E21
OFFICE FIRST FLOOR PLAN - LIGHTING
DECEMBER 2013
MB
DP
LJ

EL-L07
143 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
AA
A
B
C
A.3
A.4
A.8
B.6
B.8
B.5
24 25 26 27
O
S
S
OS
S
S
O
S
S
OS
S
O
S
S
OS
S
OS
PP
PP
O
S
S
3
S
S
O
S
S
OS
S
3
S
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
0
8
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
24 25
AA
A
S
N
SHEET NOTES SPECIFIC NOTES
1
2
SCALE:
REF: EL-L06
"=1'-0"
1
EL-L08
OFFICE SECOND FLOOR PLAN - LIGHTING
SCALE:
REF:
"=1'-0"
2
EL-L08

ROOF STAIR PLAN - LIGHTING
EL-E20.
FOR LIGHTING FIXTURES SCHEDULE, SEE SHEET E.
CONNECTIONS, SEE PANELBOARD SCHEDULES.
FOR NEWWIRING CONDUIT, AND FEEDER D.
INDICATING THEIR VOLTAGE AND USAGE.
LABEL ALL JUNCTION BOXES AND PULL BOXES C.
OTHER EQUIPMENT.
WORK, OVERHEAD PLUMBING PIPING, AND
CONDUIT INSTALLATION WITH MECHANICAL
COORDINATE ELECTRICAL EQUIPMENT AND B.
GENERAL NOTES.
ELECTRICAL ABBREVIATIONS, SYMBOLS AND
REFER TO DRAWING EL-E01 AND EL-E02 FOR A.
NOT USED
FOR WIRING CONNECTION, SEE DETAIL X/ EL-E21
8' 8' 0 16'
SCALE:"=1'-0"
OFFICE SECOND FLOOR PLAN - LIGHTING
DECEMBER 2013
MB
DP
LJ

EL-L08
144 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
UP
DN
DN
S3
321
317
319
318
314
315
316
313
310
312
307
302
306
305
303
311
301
308
S2
304
300
309
E-3
S2-4
STAIR
ELEV.
CONF.
CORR.
CORR.
CORR.
CORR.
LOBBY
ELEV.
COPY
ADMIN./
CORR.
I.T.
DIRECTOR
L.R. DEP.
DIR.
L.R.
T.R.
UNISEX
ELEC.
ROOM
INCIDENT
ROOM
COMM.
MECH.
T.R.
UNISEX
T.R.
UNISEX
STOR.
OFFICE
TRAIN.
S3-2
STAIR
CLASSROOM
320
CL.
JAN.



















1
D1
D1
G3 G3
G3
G3
B1
G1
G1 G3
G3
G
G
G
G
G
C
C1
TYPE B (TYP)
TYPE F (TYP)
TYPE F1 (TYP)
G G3 G3
G3
G1
G1
G
G
C C
G G G3

D1
D1
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
S2-4
STAIR
S2

LANDING
MOUNT 7'-0" AFF
F
F1
D1
F F1
F F
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
0
9
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
OS
S
OS
S
4
S
3
S
3
S
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
AND ACCESSIBLE.
PROVIDE JUNCTION BOX PANEL FOR LED DRIVER
FOR WIRING CONNECTION, SEE DETAIL X/ EL-E21 1
2
SHEET NOTES
SPECIFIC NOTES
SCALE:
REF: EL-L04
WASH BUILDING PLAN - LIGHTING
"=1'-0" EL-L09
1
EL-E20.
FOR LIGHTING FIXTURES SCHEDULE, SEE SHEET E.
CONNECTIONS, SEE PANELBOARD SCHEDULES.
FOR NEWWIRING CONDUIT, AND FEEDER D.
INDICATING THEIR VOLTAGE AND USAGE.
LABEL ALL JUNCTION BOXES AND PULL BOXES C.
PLUMBING PIPING, AND OTHER EQUIPMENT.
INSTALLATION WITH MECHANICAL WORK, OVERHEAD
COORDINATE ELECTRICAL EQUIPMENT AND CONDUIT B.
GENERAL NOTES.
ELECTRICAL ABBREVIATIONS, SYMBOLS AND
REFER TO DRAWING EL-E01 AND EL-E02 FOR A.
8' 8' 0 16'
SCALE:"=1'-0"
WASH BUILDING PLAN - LIGHTING
DECEMBER 2013
MB
DP
LJ

EL-L09
145 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
KEY PLAN
117
WASH BAY
119
COMM. CL.
118
ELEC.


F
F1 F1
TYPE H (TYP)
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
E
l e
c
t
r
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
E
L
L
A
1
0
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
SCALE:
YARD LEVEL FLOOR PLAN - POWER
" = 1'-0"
11
1
SPECIFIC NOTES
10
6 5 4 3 2
12
13
14
15
8 9 7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
16
16 BUSWAY 480V,3P
PANEL EMP - EMERGENCY ROOM
EMERGENCY ROOM
AUTOMATIC TRANSFER SWITCH (ATS3) -
EMERGENCY ROOM
AUTOMATIC TRANSFER SWITCH (ATS1) -
PANEL EPL - EMERGENCY ROOM
EMERGENCY ROOM
AUTOMATIC TRANSFER SWITCH (ATS2) -
PANEL EPP - EMERGENCY ROOM
OWNER METERING NO#1 - SWITCHGEAR
DISTRIBUTION NO#1 - SWITCHGEAR
MAIN BREAKER BK1 480V - SWITCHGEAR
UTILITY INCOMING NO#1
TIE BREAKER - SWITCHGEAR
DISTRIBUTION NO#2 - SWITCHGEAR
OWNER METERING NO#2 - SWITCHGEAR
MAIN BREAKER BK2 480V - SWITCHGEAR
UTILITY INCOMING NO#2 - SWITCHGEAR
8' 8' 0 16'
SCALE:"=1'-0"
YARD LEVEL FLOOR PLAN - POWER
DECEMBER 2013
MB
DP
LJ

EL-L10
146 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
D1
SUPPLY STORAGE
CLEANING
STORAGE
BULK FLUID
100
T.R.
UNISEX
101
ROOM
BREAK
L.R.
102
OFFICE
L.R.
103
STORAGE
L.R. MAINT.
104
105
ELEC.
106
107
PROTECT.
FIRE
121
ROOM
COMPRESSOR
12 13 14 15 16 17 18 19 20 15.1 12 13 14 15 16 17 18 19 20 15.1
M
A
T
C
H

L
I
N
E
CORRIDOR
BREAK ROOM
CLEANING
E-3
SERVICE
WATER
SERVICE
ELECTRICAL
SERVICE
ELECTRICAL
EMERGENCY
108
PROTECT.
FIRE
111
109
T.R.
UNISEX 110
T.R.
UNISEX
112
113
OFFICE
CLEANING
S2
S2-1
STAIR
114
ELEV.
115 116
20 21 22 23 24 25 26 27 23.1 20 21 22 23 24 25 26 27 23.1
M
A
T
C
H

L
I
N
E
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
AA
A
B
C
A.3
A.4
A.8
B.6
B.8
B.5
24 25 26 27
C
B.8
C.8
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
1
1
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
24 25 26 27
KEY PLAN
UP
DN
DN
UP
WP
WP
D2
+42"
WP
201
LOBBY
S2-3
STAIR
ROOM
TEAM
VEST.
ELEV.
I.T.
CORR.
MASTER
YARD
ROOM
INCIDENT
CORR.
CORR.
CORR.
CORR.
S2
S3-1
STAIR
SUPER.
TRANS.
COPY
ADMIN./
SUPER.
TRANS.
ASST.
COORD.
WORK BLK
CORR.
ROOM
TEAM
VEST.
T.R.
UNISEX
ELEC.
MECH.
EQUIP.
LOST/FND
DISPATCH
CONTROL CNTR
OPERATIONS
SUPER.
T.R.
UNISEX
OFFICE
TECH.
ROOM
QUIET
T.R.
UNISEX
CORR.
T.R.
WOMENS
LOCKERS
233
S3
228
227
229
214
231
214A
230
213
211
212
224
225
209
210
204
208
207
206
205
200
202
216
217
220
221
222
218 219
223
215
E-3
203
EQUIP.
226

























MATCH LINE
UP
UP
WP
WP
CORR.
S3-1
STAIR
T.R.
WOMENS
LOCKERS
MAINT.
BLDG.
KITCHENETTE
OPER. BRK RM/
237 236
232
233
235
S3
228
227


CL.
JAN.
T.R.
MENS
234



MATCH LINE
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
24'-0" 24'-0" 24'-0"
72'-0"
N
8' 8' 0 16'
SCALE: 1/8"=1'-0"
SCALE: " = 1'-0"
ZONE#8
ZONE#8
OFFICE FIRST FLOOR PLAN - POWER
OFFICE FIRST FLOOR PLAN - POWER
DECEMBER 2013
MB
DP
LJ

EL-L11
147 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
AA
A
B
C
A.3
A.4
A.8
B.6
B.8
B.5
24 25 26 27
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
1
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
SHEET NOTES
INDICATING THEIR VOLTAGE AND USAGE.
LABEL ALL JUNCTION BOXES AND PULL BOXES C.
OTHER EQUIPMENT.
WORK, OVERHEAD PLUMBING PIPING, AND
CONDUIT INSTALLATION WITH MECHANICAL
COORDINATE ELECTRICAL EQUIPMENT AND B.
ABBREVIATIONS, SYMBOLS AND GENERAL NOTES.
REFER TO DRAWING EL-L01 FOR ELECTRICAL A.
SCALE: " = 1'-0"
OFFICE SECOND FLOOR PLAN - POWER
8' 8' 0 16'
SCALE:"=1'-0"
OFFICE SECOND FLOOR PLAN - POWER
DECEMBER 2013
EUI
DP
LJ

EL-L12
148 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
UP
DN
DN
+42"
D3
S3
321
317
319
318
314
315
316
313
310
312
307
302
306
305
303
311
301
308
S2
304
300
309
E-3
S2-4
STAIR
ELEV.
CONF.
CORR.
CORR.
CORR.
CORR.
LOBBY
ELEV.
COPY
ADMIN./
CORR.
I.T.
DIRECTOR
L.R. DEP.
DIR.
L.R.
T.R.
UNISEX
ELEC.
ROOM
INCIDENT
ROOM
COMM.
MECH.
T.R.
UNISEX
T.R.
UNISEX
STOR.
OFFICE
TRAIN.
S3-2
STAIR
CLASSROOM
320
CL.
JAN.




















T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
1
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
SCALE: "=1'-0"
WASH BUILDING PLAN - POWER
LEGEND
UPS, 208/120V, 3 PHASE, 5 WIRE PANEL DC
100A, 208/120V, 3 PHASE, 4 WIRE PANEL D8
+ GROUND
ELECTRICAL DISTRIBUTION PANEL, 600A, 480/277V, 3 PHASE, 4 WIRE D4
208/120V, 3 PH, 150C TEMPERATURE RISE
30KVA DRY TYPE TRANSFORMER, PRIMARY: 480V, 3 PH; SECONDARY: TW
8' 8' 0 16'
SCALE:"=1'-0"
WASH BUILDING PLAN - POWER
DECEMBER 2013
MB
DP
LJ

EL-L13
149 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
KEY PLAN
WP
WP WP WP WP WP WP
WP WP
+42" (TYP)
WP WP
WP
D8 DC
D4
TW
118
ELEC.
119
COMM. CL.

117
WASH BAY
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
E
l e
c
t
r
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
E
L
L
A
1
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
F
F F
F F
F
F
F
F
F
F
F F
F
S S S S S S S
S S S S S S S
S S S S S S S
A
B
C
D
1 15 15.1 2 3 4 5 6 8 9 10 14 13 12 11 7 7.1 23 23.1 16 17 18 19 20 21 22 24 25 26 27
N
SCALE: 1" = 30'
YARD STORAGE PLAN - FIRE ALARM
30' 30' 0 60'
SCALE:1"=30'
YARD STORAGE PLAN - FIRE ALARM
DECEMBER 2013
MB
DP
LJ

EL-L14
150 1"=30'
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
110 C
150 C 150 C
110 C 110 C
150 C
110 C
150 C
110 C
150 C
110 C
150 C 110 C
110
C
A
A
12 15.1 13 14 15 16 17 18 19 20
S
S
F
S
S
F
12 15.1 13 14 15 16 17 18 19 20
23.1 20 21 22 23 24 25 26 27
F
S
S S
F
F
F
F
F
S F
F
F
F
F
23.1 20 21 22 23 24 25 26 27
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
E
l e
c
t
r
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
E
L
L
A
1
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
SCALE: SCALE
YARD LEVEL PLAN - FIRE ALARM
8' 8' 0 16'
SCALE:"=1'-0"
YARD LEVEL FLOOR PLAN - FIRE ALARM
DECEMBER 2013
MB
DP
LJ

EL-L15
151 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
15
15
100
T.R.
UNISEX
PROTECT.
FIRE
STORAGE
BULK FLUID
SUPPLY STORAGE
CLEANING
STORAGE
L.R. MAINT.
ROOM
BREAK
L.R.
OFFICE
L.R.
ROOM
COMPRESSOR
ELEC.
101
102
122 103 104 107 106
105







M
A
T
C
H

L
I
N
E
UP
15
15
15
E
15
15
S2-1
STAIR
OFFICE
CLEANING
BREAK ROOM
CLEANING
SERVICE
WATER
CORRIDOR
PROTECT.
FIRE
SERVICE
ELECTRICAL
SERVICE
ELECTRICAL
EMERGENCY
115
116
114 S2 113 112
108
111
110
T.R.
UNISEX
109
T.R.
UNISEX
ELEV.
E-3









15
M
A
T
C
H

L
I
N
E
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
AA
A
B
C
A.3
A.4
A.8
B.6
B.8
B.5
24 25 26 27
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
S
S
F
F
F
S
S
FAAP
F
F
F
F
F
F
C
B.8
C.8
F
F
F
F
F
F
F
F
F
F
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
1
6
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
24 25 26 27
KEY PLAN
UP
DN
DN
UP
15
E
30
60
15
30
15
30
15
30
15
30
30
60
15
30
30
75
30
60
60
15
15
30
15
15
75
15
201
LOBBY
S2-3
STAIR
ROOM
TEAM
VEST.
ELEV.
I.T.
CORR.
MASTER
YARD
ROOM
INCIDENT
CORR.
CORR.
CORR.
CORR.
S2
S3-1
STAIR
SUPER.
TRANS.
COPY
ADMIN./
SUPER.
TRANS.
ASST.
COORD.
WORK BLK
CORR.
ROOM
TEAM
VEST.
T.R.
UNISEX
ELEC.
MECH.
EQUIP.
LOST/FND
DISPATCH
CONTROL CNTR
OPERATIONS
SUPER.
T.R.
UNISEX
OFFICE
TECH.
ROOM
QUIET
T.R.
UNISEX
CORR.
T.R.
WOMENS
LOCKERS
233
S3
228
227
229
214
231
214A
230
213
211
212
224
225
209
210
204
208
207
206
205
200
202
216
217
220
221
222
218 219
223
215
E-3
203
EQUIP.
226

























MATCH LINE
UP
UP
30
15
75
15
75
30
30
15
CORR.
S3-1
STAIR
T.R.
WOMENS
LOCKERS
MAINT.
BLDG.
KITCHENETTE
OPER. BRK RM/
237 236
232
233
235
S3
228
227


CL.
JAN.
T.R.
MENS
234



MATCH LINE
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
24'-0" 24'-0" 24'-0"
72'-0"
N
8' 8' 0 16'
SCALE: 1/8"=1'-0"
SCALE: " = 1'-0"
ZONE#8
ZONE#8
OFFICE FIRST FLOOR PLAN - FIRE ALARM
OFFICE FIRST FLOOR PLAN - FIRE ALARM
DECEMBER 2013
EUI
DP
LJ

EL-L16
152 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
AA
A
B
C
A.3
A.4
A.8
B.6
B.8
B.5
24 25 26 27
FS
S
S
S
S
S
FS
F
S
S
F
F
F
F
F
F
F
H H
F
F
F
F
F
F
F
F
F
F
F
F
TS
TS
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
1
7
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
24 25
AA
A
F F
N
SHEET NOTES
SCALE:
OFFICE SECOND FLOOR PLAN - FIRE ALARM
" = 1'-0"
SCALE: " = 1'-0"
ROOF STAIR PLAN - FIRE ALARM
OTHER EQUIPMENT.
WORK, OVERHEAD PLUMBING PIPING, AND
CONDUIT INSTALLATION WITH MECHANICAL
COORDINATE ELECTRICAL EQUIPMENT AND B.
ABBREVIATIONS, SYMBOLS AND GENERAL NOTES.
REFER TO DRAWING EL-L01 FOR ELECTRICAL A.
8' 8' 0 16'
SCALE:"=1'-0"
OFFICE SECOND FLOOR PLAN - FIRE ALARM
DECEMBER 2013
EUI
DP
LJ

EL-L17
153 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
UP
DN
DN
E
30
30
60
60
75
15
15
15
60
15
15
15
60
15
15
75 15
60
S3
321
317
319
318
314
315
316
313
310
312
307
302
306
305
303
311
301
308
S2
304
300
309
E-3
S2-4
STAIR
ELEV.
CONF.
CORR.
CORR.
CORR.
CORR.
LOBBY
ELEV.
COPY
ADMIN./
CORR.
I.T.
DIRECTOR
L.R. DEP.
DIR.
L.R.
T.R.
UNISEX
ELEC.
ROOM
INCIDENT
ROOM
COMM.
MECH.
T.R.
UNISEX
T.R.
UNISEX
STOR.
OFFICE
TRAIN.
S3-2
STAIR
CLASSROOM
320
CL.
JAN.



















T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
S2-4
STAIR
S2

15
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
1
8
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
F F F F
F
F
F F
S S
F
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
SCALE: "=1'-0"
WASH BUILDING - FIRE ALARM
8' 8' 0 16'
SCALE:"=1'-0"
WASH BUILDING - FIRE ALARM
DECEMBER 2013
EUI
DP
LJ

EL-L18
154 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
KEY PLAN
60
60 60 60
60
60
60
WASH BAY
117

118
ELEC.
119
COMM. CL.

MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
2
0
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.

NOTES
HOUSING STANDARD LENGHTS.
FILL-IN. COORDINATE WITH MANUFACTURER FOR LIGHTING FIXTURE
4. PROVIDE LIGHTING FIXTURE LENGHT WITH ROOM DIMENSION TO
REQUIRED.
TO ACTIVE LIGHTING FIXTURE DURING DAYTIME HOURS AND
DURING OVERNIGHT SECURITY HOURS. DAY-LIGHTING PHOTO SENSOR
3. LIGHTING FIXTURE TO BE DIMED TO 90% DURING EVENING AND 50%
2. ALL LAMPS SHALL BE LOW-MERCURY TYPE.
SEE DETAILS FOR LIGHTING FIXTURE SUPPORTING.
1. COORDINATE LIGHTING FIXTURE INSTALLATION WITH CEILING TYPE.
TYPE SYMBOL DESCRIPTIONS MANUFACTURER/CATALOG NO EQUAL MANUFACTURER LAMP VOLT WATTS MOUNTING REMARKS
FOR CORRIDORS RECESSED
RECESSED
RECESSED
RECESSED
RECESSED
SURFACES
FLUORESCENT LIGHTING FIXTURE
4-FT. SURFACE WALL MOUNTED
FOR OFFICES
FOR OFFICES
FOR TOILETS
LIGHTING FIXTURE
4-FT. COVE PERIMETER FLUORESCENT
SEE NOTE 4.
FOR TOILETS
FLUORESCENT LIGHTING FIXTURE
VARIOUS LENGHT COVE PERIMETER
SURFACES
PENDANT
SURFACES /
FOR STAIRS
FIXTURE ON EMERGENCY POWER
4-FT. WALL MOUNTED FLUORESCENT LIGHTING
2'X2' FLUORESCENT LIGHTING FIXTURE
2'X4' FLUORESCENT LIGHTING FIXTURE
EMERGENCY POWER
2'X4' FLUORESCENT LIGHTING FIXTURE ON
4-FT. INDUSTRIAL STRIP LIGHT
PENDANT
SURFACES /
4-FT. STRIP LIGHT ON EMERGENCY POWER
RECESSED FOR VESTIBULES 6" RECESSED DOWNLIGHT
6" RECESSED DOWNLIGHT WITH CLEAR LENS RECESSED FOR TOILETS / SHOWERS
RECESSED 6" DOWNLIGHT ON EMERGENCY POWER
LED EXIT SIGNS
CEILING
WALL /
SURFACE
RECESSED /
ENTRANCE / EXIT ROUTES 6" EXTERIOR LIGHTING FIXTURE
LED CANOPY LIGHTING FIXTURE FOR YARD STORAGE AREAS PENDANT
TRACK AREAS
FOR PARKING, YARD AND
POLE
25 FT.
WITH 25 FT. POLE
LED YARD / TRACK LIGHT SINGLE LIGHT UNIT
EMERGENCY POWER
2'X2' FLUORESCENT LIGHTING FIXTURE ON
A
A1
B
B1
C
C1
D
D1
E
F
F1
G
G1
G2
G3
H
K
L
M
P
FOR CORRIDORS RECESSED 277
-MVOLT-ACNS-LP835
LITHONIA 2SP8-G-2-CF40-A12125
277
277
277
277
277
277
277
277
277
277
277
277
277
277
277
277
120
277
277
120-
MECHANICAL ROOM
STORAGE / ELECTRICAL /
MECHANICAL ROOM
ELECTRICAL /
FOR WASH AREAS
ELEVATOR PIT
CONFERENCE ROOM
PENDANT
RECESSED
SURFACES
LED BARS
(8)
LED
CF
CF
CF
CF
LED
LED BARS
(3) 21
(2) T5
(2) T5
(2) T5
(2) T5
835
(3) 54T5HO
835
(3) 54T5HO
CF40 835
(2)
CF40 835
(2)
-MVOLT-EL
LITHONIA 2SP8-G-2-CF40-A12125
-MVOLT-GEB10PS-LB835
LITHONIA 2SP5-G-3-54T5HO-RA125
-MVOLT-GEB10PS-EL14
LITHONIA 2SP5-G-3-54T5HO-RA125
70-2-T5-UNV-EB-SI-S72
COPPER NEORAY
70-2-T5-UNV-EB-SI-S72
COPPER NEORAY
COPPER STAIRLITE 2 SL2-4-7
LITHONIA EJS-2-32-MVOLT-BPHP
LITHONIA EJS-2-32-MVOLT-EL
LITHONIA LP6FN-26TRT-609AZ-MVOLT
LP6FN-26TRT-609AZ-CGL-MVOLT
LITHONIA
LP6FN-26TRT-609AZ-CGL-MVOLT-ECOS
LITHONIA
LP6FN-26TRT-609AZ-CGL-MVOLT
LITHONIA
COPPER SURE-LITE EU-S-60-R
COPPER CONCISE CNC-B03-LED-E1-RW
HBLED-LD2-24-N-CL-UNIV-L850-CD3
COPPER METALUX
COPPER VENTUR VTS-B10-LED-E1-T4
COPPER PL-VS-W-GG-32-UNV
LED HIGHBAY LIGHTING FIXTURE
BALLAST
6" RECESSED DOWNLIGHT WITH DIMMING
FIXTURE
VAPORTIGHT COMPACT FLUORESCNT LIGHTING
LIGHTING FIXTURE SCHEDULE
LIGHTING FIXTURE SCHEDULE
DECEMBER 2013
MB
DP
LJ

EL-L20
155 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
3" 4.5" 3" 4.5" 3"
3"
4.5"
3"
4.5"
3"
4.5"
3"
































































MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
2
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
SCALE:
TYPICAL 9 AND 6-WAY - 4" PVC CONCRETE ENCASED DETAIL
NOT TO SCALE
22 1/2"
2
2

1
/
2
"
6" (TYP)
6
"

(
T
Y
P
)
(
T
Y
P
)
5

1
/
4
"
22 1/2"
2
2

1
/
2
"
6
"

(
T
Y
P
)
6" (TYP)
4" SCHED 40 PVC (TYP)
SCALE: NOT TO SCALE
TYPICAL 6-WAY DUCTBANK
30". PROVIDE CONDUIT SPACERS.
NOMINAL COVER TO TOP OF ENVELOP SHALL BE
ENTERING BUILDINGS, OR ENTERING MANHOLES.
PLACING IN ROADWAYS, CROSSING ROADWAYS,
PROVIDE REINFORCING RODS ON TOP OF DUCTS
SPECIFIED.
CONCRETE SHALL BE 3,000 PSI @ 28 DAYS OR AS
SCALE:
FRONT VIEW
NOT TO SCALE
SCALE:
SECTION A-A
NOT TO SCALE
SCALE:
SECTION A-A
NOT TO SCALE
GROUND GRID
TO BUILDING
GROUND BUS
TO SWITCHBOARD
BUILDING STEEL
CONNECTION TO
EXOTHERMIC
(TYPICAL FOR 2)
SEE SECTION "A-A" ABOVE
INSULATOR MOUNTING BOLT.
INSULATORS.
MOUNTED TO WALL WITH
COPPER BUS SERVICE
1/4" X 2" X 2'-0" LONG
GROUNDING TRIPOD.
IN 1 1/4"C. TO EXTERIOR
500 KCMIL GROUND CONDUCTOR
SERVICE PIPE
WATER
TO BUILDING
PADS
AND GENERATOR
TO TRANSFORMER
1/4"C. (TYP)
CONDUCTOR IN 1
#4/0 CU GROUND

1/4"C. (TYP)
CONDUCTOR IN 1
#4/0 CU GROUND

1/4"
1 1/2"
1/4"
1 1/2"
BUS
COPPER GROUND
BUS
COPPER GROUND
INTERIOR/EXTERIOR WALL
MOUNTING METHOD
APPROVED
SHIELD OR
LEAD EXPASION
INSULATOR
POLYESTER FIBERGLASS
FINISHED FLOOR
1
2
"

A
F
FBUS
COPPER GROUND
INSULATOR
POLYESTER FIBERGLASS
BUS
COPPER GROUND
INTERIOR/EXTERIOR WALL
MOUNTING METHOD
APPROVED
SHIELD OR
LEAD EXPASION
ELECTRICAL DETAILS - 1
DECEMBER 2013
EUI
DP
LJ

EL-L21
156 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443




MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
2
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
SCALE:
POWER RISER DIAGRAM
NOT TO SCALE
SECOND FLOOR
ROOF
YARD LEVEL
FIRST FLOOR
EPL
DOUBLE ENDED MAIN SWITCHBOARD
480/277V, 2PH, 4W, 1000A
EMERGENCY ELECTRICAL ROOM
UPS EPP
D1
D2
D3
MAIN ELECTRICAL ROOM
D5 D4
N
ATS1
E


E N
ATS3
EMP
N
ATS2
E
T1 T2
480/277V FEEDERS
UTILITY FEEDERS
100A
400A
200KW/250KVA AT 0.8 POWER FACTOR
EMERGENCY GENERATOR OUTDOOR
CIRCUIT BREAKER WITH SHUNT TRIP FOR GENERATOR MOBIL LOAD TEST
LEGEND
D6
D7
UPSB
PANEL
SEE DRAWING EL-L23.
POWER RISER DIAGRAM
DECEMBER 2013
EUI
DP
LJ

EL-L22
157 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
~
~
~
~
~
~
T2
SPD
T1
FT
CT
PT
BK2 GFP
UTILITY SERVICE MEDIUM VOLTAGE
SPD
UTILITY SERVICE MEDIUM VOLTAGE
SPD
FT
SPD F F
PT PT
N.O.
F
GFP
CT
TIE BK BKI
PMD
D4 D3 D1 D5 D2
PMD
MAIN SWITCHBOARD 2000A,480V,3 PH, 4-W
D6 D7
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
2
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
SCALE:
POWER SINGLE LINE DIAGRAM - DOUBLE ENDED FEED
NOT TO SCALE
EMP
UPS EPP EPL
E N E E N N
LEGEND
E
METERING
UTILITY
METERING
UTILITY
ATS1 ATS2 ATS3
UPSB
DEVICE
WITH SHUNT TRIP
CIRCUIT BREAKER
GENERATOR TEST
AT 0.8 POWER FACTOR
200KW, 3PH, 480V
EMERGENCY GENERATOR
208/120V, 3 PHASE, 5 WIRE UPS PANEL
208/120V, 3 PHASE, 5 WIRE UPS PANEL
PANEL
MAIN UPS PANEL, 208/120V, 3 PHASE, 5 WIRE UPS
4 WIRE + GROUND. (STAND BY POWER).
EMERGENCY ELECTRICAL PANEL, 225A, 480V, 3 PH,
SYSTEM 100A, 480V, 3 PH, 4-WIRE + GROUND.
EMERGENCY ELECTRICAL PANEL FOR LIFE SAFETY
4-WIRE + GROUND.
MAIN EMERGENCY PANEL, 400A, 480V, 3 PH,
3 PH, 4 WIRE + GORUND.
ELECTRICAL DISTRIBUTION PANEL SPARE. 225A, 480V,
600A, 480V, 3 PH, 4-WIRE + GROUND.
ELECTRICAL DISTRIBUTION PANEL FOR WASH BUILDING.
LEVEL. 225A, 480V, 3 PH, 4-WIRE + GROUND.
ELECTRICAL DISTRIBUTION PANEL FOR SECOND FLOOR
LEVEL. 400A, 480V, 3 PH, 4- WIRE + GROUND.
ELECTRICAL DISTRIBUTION PANEL FOR FIRST FLOOR
LEVEL STORAGE AREAS---400A, 3PH, 4-WIRE + GROUND.
ELECTRICAL DISTRIBUTION PANEL FOR SPACE IN YARD
TIE CIRCUIT BREAKER.
CURRENT TRANSFORMER.
POTENCIAL TRANSFORMER.
LOWVOLTAGE FUSE.
GROUND FAULT PROTECTION RELAY.
2000A, 600V, 3PH.
SECONDARY 480 /277, 3PH.
1500 KVA, TRANSFORMER, PRIMARY MEDIUM VOLTAGE,
SURGE PROTECTION DEVICE.
MEDIUM VOLTAGE FUSE.
D7
D6
UPSB
UPS
EPP
EPL
EMP
D5

D4

D3


D2

D1
TIE BK
CT
PT
F
GFP
BK1, BK2

T1 AND T2
SPD
FT
POWER SINGLE LINE DIAGRAM
DECEMBER 2013
MB
DP
LJ

EL-L23
158 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
E
l e
c
t
r
i c
a
l \
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
E
L
L
A
2
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
24 25 26 27
AA
A
B
C
A.3
A.4
A.8
B.6
B.8
C.8
B.5
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
SILENCE
TROUBLE
TEST
LAMP
RESET
SYSTEM
KEY
ALARM LOCATION
R
R
SECOND FLLOR
R FIRST FLOOR
YARD LEVEL
G
Y
R
POWER STATUS
NORMAL POWER ON
BATTERY POWER ON
SYSTEM TROUBLE
R
R
R
Y
Y
Y
R
Y
Y
MANUAL PULL STATION
SMOKE DETECTOR
HEAT DETECTOR
DUCT SMOKE DETECTOR
TAMPER SWITCH
WATER FLOOR SWITCH
ELEVATOR ROOM SMOKE DETECTOR
BEAM DETECTOR
ELEVATOR ROOM HEAT DETECTOR
R
G FIRE CURTAIN OPEN
FIRE CURTAIN CLOSED
R
Y
G
LED YELLOW
LED RED
LED GREEN
NOTES
SHOP AND YARD
LYTTONSVILLE
ANNUNCIATOR PANEL
FIRE ALARM
SECOND FLOOR FIRST FLOOR YARD LEVEL
SCALE:
FIRE ALARM ANNUNCIATOR PANEL
1" = 40'
DEVICE TYPE
FIRE ALARM ANNUNCIATOR PANEL DIAGRAM
DECEMBER 2013
MB
DP
LJ

EL-L24
159 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
S3 321
320 317
319 318
314 315
316
313
310
312
307
302
306
305
303
311
301 308
S2
304
300
309
E-3 S2-4 STAIR ELEV.
CONF.
CORR.
CORR.
CORR.
CORR.
LOBBY ELEV.
COPY ADMIN./
CORR. I.T.
DIRECTOR L.R. DEP.
DIR. L.R.
T.R. UNISEX ELEC.
ROOM INCIDENT
ROOM COMM.
MECH.
T.R. UNISEX
T.R. UNISEX
JAN. CL. STOR.
CLASSROOM
OFFICE TRAIN.
S3-2 STAIR
237
236
234
232
233
235
S3
228
227 229
226 214
231
214A
230
213
211
212
224
225
209
210
204
208 207
206
205
200
202 216
217
220 221 222
218 219
223
215
E-3
203
201 LOBBY
S2-3 STAIR
ROOM TEAM
VEST.
ELEV.
I.T. CORR. MASTER YARD ROOM INCIDENT
CORR.
CORR.
CORR.
CORR.
S2
S3-1 STAIR
SUPER. TRANS. COPY ADMIN./
SUPER. TRANS. ASST. COORD. WORK BLK
CORR.
ROOM TEAM
VEST.
T.R. UNISEX
ELEC.
MECH.
EQUIP.
LOST/FND
DISPATCH
CONTROL CNTR OPERATIONS
SUPER. T.R. UNISEX OFFICE
EQUIP.
TECH.
ROOM QUIET
T.R. UNISEX
CORR.
T.R. WOMENS
T.R. MENS
LOCKERS
JAN. CL.
MAINT. BLDG.
KITCHENETTE OPER. BRK RM/
238 MACHINE CL ELEVATOR
FS PS TS H S F
F F
S
ACV
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
2
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
SCALE:
FIRE ALARM RISER AND ANNUNCIATOR PANEL DIAGRAM
NOT TO SCALE
LEGEND
LOCATED AT SECOND FLOOR FATC (4)
LOCATED AT FIRST FLOOR FATC (3)
LOCATED AT YARD LEVEL EAST FATC (2)
LOCATED AT YARD LEVEL WEST FATC (1)
FIRE ALARM TERMINAL CABINET FATC
FIRE ALARM NOTES
(TYP)
FATC
15 15
YARD LEVEL
PANEL
CONTROL
FIRE ALARM
(4)
FATC
120V
FIRST FLOOR
PANEL
ANNUNCIATOR
FIRE ALRM
SECOND FLOOR
(2)
FATC
(1)
FATC
(3)
FATC
SCALE: NOT TO SCALE
FIRE ALARM TERMINAL CABINET TYPICAL CONNECTIONS
17.
16.
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
ACTUAL COUNTS OF FIRE ALARM DEVICES IS PER PLANS.
SHOP DRAWINGS SHALL INCLUDE INSTALLATION AND PROGRAMMING INSTRUCTIONS.
COMPLETION OF THE PROJECT.
SHALL BE RESPONSIBLE TO SUPPLY THESE SPARE PARTS TO THE OWNER AT THE
SHOP DRAWINGS SHALL INCLUDE THE LIST OF SPARE PARTS. THE CONTRACTOR
OF DEVICE, CURRENT REQUIREMENTS AND LOCATION.
SPECIFICATIONS. BATTERY CALCULATIONS SHALL INDICATE NUMBER OF EACH TYPE
SHOP DRAWING SHALL INCLUDE BATTERY CALCULATIONS IN ACCORDANCE WITH
ACCORDANCE WITH NFPA 72 AND CITY OF BALTIMORE FIRE MARSHALL.
THE FLOOR PLANS, EXITS AND ALL INDICATING LIGHTS AND CONTROLS ETC. IN
SHOP DRAWINGS SHALL INCLUDE THE FIRE ALARM ANNUNCIATION PANEL INDICATING
EQUIPMENT AND/OR DEVICE.
SHOP DRAWINGS SHALL CLEARLY INDICATE THE PHYSICAL DIMENSIONS OF EACH
THE SIZE OF CONDUIT.
DEVICE WIRING DETAILS CLEARLY INDICATING THE NUMBER OF CONDUCTORS AND
SUBMIT FIRE ALARM WIRING RISER DIAGRAM, PANEL WIRING DIAGRAM AND EACH
HEIGHT ON THE FLOOR PLANS.
THE CANDELA POWER AND SOUND LEVEL WITH EACH DEVICE AND THEIR MOUNTING
COMPONENTS SUCH AS JUNCTION BOXES. SHOP DRAWINGS SHALL CLEARLY INDICATE
ZONES AND THE LOCATIONS OF ALL FIRE ALARM EQUIPMENT, DEVICES AND OTHER
SHOP DRAWINGS SHALL INCLUDE ALL BUILDING FLOOR PLANS INDICATING THE
BOTH AT ANNUNCIATION PANEL AND AT FIRE ALARM CONTROL PANEL.
PROVIDE SHUT OFF SWITCHES FOR HVAC UNITS IN ACCORDANCE WITH NFPA 72,
AND "OFF"
PROVIDE EMERGENCY GENERATOR STATUS INDICATING FOR EMERGENCY POWER "ON"
COORDINATING WITH APPROVED SHOP DRAWINGS OF FIRE PROTECTION SYSTEM.
PREPARING ZONES. THE FIRE ALARM SHOP DRAWINGS SHALL BE SUBMITTED AFTER
FIRE ALARM SYSTEM SHALL BE COORDINATED WITH FIRE PROTECTION SYSTEM IN
OF DETECTORS TO COVER ALL POCKETS CREATED BY EXPOSED CEILING BEAMS.
NUMBER REQUIRED TO MEET NFPA72 REQUIREMENTS. PROVIDE A SUFFICIENT NUMBER
NUMBER OF SMOKE DETECTORS SHOWN IN EACH ROOM MAYBE LESS THAN THE ACTUAL
SHEET FOR MOUNTING HEIGHT OF FIRE ALARM DEVICES.
IS IN THE LINE OF SIGHT AND ADA REQUIREMENTS. SEE DETAIL 2/E5.05 ON THIS
DOORS. ALL FIRE ALARM VISUAL DEVICES SHALL BE MOUNTED AT A HEIGHT WHICH
ALL MANUAL PULL STATIONS SHALL BE LOCATED WITHIN 5 FEET OF THE EXIT
FIRE ALARM SYSTEM DEVICES AND EQUIPMENT ARE SHOWN ON THE PLANS.
ANY INSTALLATION OF THE SYSTEM WORK.
APPROVAL PRIOR TO ANY SUBMISSION TO ARCHITECT OF RECORD AND ENGINEER AND
DRAWINGS TO STATE OF MARYLAND FIRE MARSHALL AND OBTAIN FIRE MARSHAL'S
THE CONTRACTOR SHALL BE RESPONSIBLE TO SUBMIT THE FIRE ALARM SYSTEM SHOP
MANUFACTURER AND MARYLAND STATE FIRE MARSHAL'S REQUIREMENTS.
FIELD. THE INSTALLATION OF THE FIRE ALARM SYSTEM SHALL MEET SYSTEM'S
THE MANNER OF CONNECTIONS SHALL BE DETERMINED BY THE CONTRACTOR IN
FIRE ALARM SYSTEM RISER DIAGRAM IS DIAGRAMMATIC. RUNS OF RACEWAYS AND
INSTALLED IN EMT RACEWAYS.
CITY OF BALTIMORE FIRE MARSHAL REQUIREMENTS. ALL WIRING SHALL BE
IN ACCORDANCE WITH THE FIRE ALARM MANUFACTURER'S RECOMMENDATIONS AND
ALL WIRING SIZES, RACEWAY SIZES, AND THEIR QUANTITIES SHALL BE STRICTLY
RISER AND NOTES - FIRE ALARM
DECEMBER 2013
MB
DP
LJ

EL-L25
160 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
4
7
2
\
1
0
4
2
p
E
L
L
A
2
6
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent













S


S
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
ELECTRICAL DETAILS - 2
DECEMBER 2013
EUI
DP
LJ

EL-L26
161 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
G
N
SCALE:
REF:
NOT TO SCALE
1
EL-L26
NEUTRAL
GROUND
PHASE LIGHTING LOAD
PHASE
GROUND
NEUTRAL
SENSOR
OCCUPANCY
LIGHTING LOAD
SCALE:
REF:
NOT TO SCALE
2
EL-L26
G
N
N
PP
N
N N
N
N
C
N
TO LIGHTING
CEILING
SCALE:
REF:
NOT TO SCALE
4
EL-L26
SCALE:
REF:
NOT TO SCALE
5
EL-L26
WITH DAYLIGHTING CONTROLLER AND OCCUPANCY SENSOR
AUTOMATIC DAYLIGHTING CIRCUIT CONTROL (ON-OFF)

OCCUPANCY SENSOR LIGHTING CONTROL DIAGRAM
AUTOMATIC CEILING/WALL MOUNTED DUAL-TECHNOLOGY

SENSOR WIRING DIAGRAM (SMALL ROOM)
SINGLE LEVEL WALL - SWITCH WITH
CONTROL WIRING DIAGRAM (LARGE ROOM)
LIGHTING SWITCHING WITH OCCUPANCY SENSOR
C
C
SCALE:
REF:
NOT TO SCALE
3
EL-L26
PARKING LOT/YARD LIGHTING CONTROL DIAGRAM
LIHGT
PARKING
LIGHTING
YARD
PANEL LCP1
ROOM 003
3PH, 4W
277/480V
PANEL
ROOM
A B C N
PANEL FEEDER
277 VAC CONTROL PANEL
AND KEYPAD DISPLAY LOCATED IN LIGHTING
CONNECT TO TIME CLOCK SYSTEM NETWORK
PP N
C
N
N
N
C
TO LIGHTING
N
CEILING
DAY LIGHT
NATURAL
SWITCH
MANUAL TOGGLE
CONTROLLER RELAY UNIT
POWER PACK AND
DUAL - TECHNOLOGY SENSOR
AUTOMATIC WALL SWITCH WITH
SENSING
SWITCHES
MANUAL TOGGLE
(TYPICAL)
OCCUPANCY SENSOR
DUAL-TECHNOLOGY
CEILING MOUNTED
(TYPICAL)
OCCUPANCY SENSOR
DUAL-TECHNOLOBY
WALL MOUNTED
(TYPICAL)
FIXTURE
PENDANT LIGHTING
ON/OFF AUTOMATIC LIGHTING CONTROLLER
POWER PACK AND CONTROLLER RELAY UNIT
(TYPICAL)
RECESSED LIGHTING FIXTURE
IS RATED AT 30A CONTINUOUS.
LIGHTING CONTROL PANEL. EACH RELAY

(TYPICAL)
RECESSED LIGHTING FIXTURE
SENSOR
DAYLIGHTING
CEILING MOUNTED
OCCUPANCY SENSOR
DUAL-TECHNOLOGY
CEILING MOUNTED
(TYPICAL)
FIXTURE
LIGHTING
PENDANT
SWITCHES
MANUAL TOGGLE

PHOTOCELL MOUNTED ON ROOF

TO 277 VAC

TO 277 VAC

TO 277 VAC
TO 277 VAC
CIRCUIT ON 60 AVERAGE FOOTCANDLES AND ABOVE)
ON 0-10 AVERAGE FOOTCANDLES ON FLOOR AND TURNS "OFF"
ON/OFF AUTOMATIC LIGHTING CONTROLLER (TURN "ON" CIRCUIT
POWER PACK AND DAY LIGHTING CONTROLLER RELAY UNIT
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
5
4
4
\
1
0
4
2
p
F
P
L
A
0
1
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.

FLOWDETECTOR / SWITCH
PIPE HANGER
ALARM CHECK VALVE
BRANCH LINE
SPRINKLER PIPING AND
TAMPER DETECTOR / SWITCH
TAMPER DETECTOR / SWITCH
VALVE WITH
FIRE DEPARTMENT CONNECTION
FIRE HOSE CABINET
STANDPIPE
SIAMESE
FHC
DOUBLE CHECK TYPE
FIRE HOSE VALE/
BACKFLOWPREVENTER
CHECK VALVE
PRIVATE HYDRANT
ONE HOSE OUTLET
OS&Y VALVE W/TS
POST INDICATOR VALVE
VALVE (GENERAL)
PHASE PH
EQUAL EQ
MIN
FLEX FLEXIBLE
FIN
FL
FA
FB
FINISHED
FLANGE
FROM BELOW
FROM ABOVE
EXT
EQUIV
ETC
EQUIP
EXTERNAL
ET CETERA
EQUIVALENT
EQUIPMENT
NIC
NPW
NOM
NTS
NO
No
NC
MISC
MTD
DEGREES CENTIGRADE
ID
DOWN DN
ENT
ELEV
EA
(E)
DWG
ENTERING
ELEVATION
EACH
EXISTING
DRAWING
DIW
DISCH
DIAG
DIA
DOWN IN WALL
DISCHARGE
DIAGRAM
DIAMETER
MED
MFR
MC
MAX
INCL
INV
CONTR
CONT'N
CONC
CONN
CONTRACTOR
CONCRETE
CONTINUATION
CONNECTION
COL
COMP
CLG
COMPRESSOR
COLUMN
CEILING
HP
HD
HT
GPM
GA
GALV
GC
MINIMUM
REINFORCED CONCRETE PIPE
NOT IN CONTRACT
NON-POTABLE WATER
NOMINAL
NOT TO SCALE
NUMBER
NORMALLY OPEN
NORMALLY CLOSED
MOUNTED
MISCELLANEOUS
SCHEDULE
SCHEMATIC
REVOLUTION PER MINUTES
SCH
SCHEM
RPM
RELIEF
REQUIRED REQD
RCP
REL
RUN BELOWCEILING
PRESSURE INDICATOR
PRESSURE GAUGE
POUNDS PER SQUARE INCH GAUGE
POUNDS PER SQUARE INCH
RUN BETWEEN JOIST
INTERNAL DIAMETER
MECHANICAL CONTRACTOR
MANUFACTURER
MEDIUM
MAXIMUM
INCLUDING
INVERT
RUN BELOWFLOOR
RUN AT CEILING
RUN ABOVE FLOOR
RBF
RBJ
RAF
RBC
RATC
RUN ABOVE CEILING
QUANTITY
QUICK DISCONNECT QD
RAC
QT.
PI
HEAD (SEE SCHEDULES)
HORSE POWER
HEIGHT
GENERAL CONTRACTOR
GALLONS PER MINUTE
GALVANIZED
GAUGE
PG
POSITIVE
PRESSURE
PRESSURE SWITCH
PSIG
PSI
PS
POS
PRESS
TEMPERATURE
TYPICAL
TOTAL PRESSURE
WITHOUT
W/
W/O
W
WITH
WIDTH
TYP
TP
TEMP
SQUARE
SPECIFICATION
STANDARD
SYSTEM
SUPPLY
STRAINER
TOTAL DYNAMIC HEAD
SUPPORT STEEL
STAINLESS STEEL
TDH
SYS
SUP
STR
STD
STL
SST
STEEL
SQ
SS
SPEC
BACKFLOWPREVENTER
ABOVE FINISHED FLOOR
CUBIC FEET PER HOUR
BUILDING BLDG
CFH
BLW BELOW
BFP
AMPS
ABV
AFF
AMPERES
ABOVE
FS
FXC
FTB
FT
FDC
FP
FLR
FLOWSWITCH
FLOOR TO BOTTOM
FLEXIBLE CONNECTION
FIRE DEPARTMENT CONNECTION
FEET
FIRE PROTECTION
FLOOR
PARTIAL PART
OPENING
OUTSIDE DIMENSION
OFF TOP
OPEN SITE
OPG
OS
OT
OD
F
X
FIRE PROTECTION RISER NUMBER
WATER DENSITY = 0.10 GPM/SQ. FT.
MAXIMUM SPRINKLER COVERAGE = 225 SQ. FT.
MAXIMUM SPRINKLER COVERAGE = 130 SQ. FT.
WATER DENSITY = 0.15 GPM/SQ. FT.
DESIGN AREA = 1500 SQ. FT.
ORDINARY HAZARD - GROUP 1 B.
DESIGN AREA = 1500 SQ. FT.
LIGHT HAZARD A.
FHV FIRE HOSE VALVE
FHVC FIRE HOSE VALVE CABINET
TAMPER SWITCH TS
PRESSURE REGULATING VALVE PRV
PRESSURE REDUCING VALVE
FS
TS
TS TS
TS TS
STR
STRAINER
PS
PRESSURE SWITCH
PG
PRESSURE GAUGE
OS&Y VALVE
PRV
"REDUCER 2
1
1 "FHV W/ 2
1
2
STANDPIPE
FDC FDC
TS
PRV
STR
ORDINARY HAZARD - GROUP 2 C.
MAXIMUM SPRINKLER COVERAGE = 130 SQ. FT.
WATER DENSITY = 0.20 GPM/SQ. FT.
DESIGN AREA = 1500 SQ. FT.
DESIGN CRITERIA
ORDINARY HAZARD - GROUP 1
LIGHT HAZARD
ORDINARY HAZARD - GROUP 2
LH
OHGR-1
OHGR-2
FP01
FP02
FIRE PROTECTION - GENERAL NOTES, SYMBOLS AND ABRREVIATIONS
DESIGN CRITERIA AND HAZZARD CLASSIFICATIONS
DRAWING LISTS GENERAL NOTES
FIRE PROTECTION GENERAL NOTES SYMBOLS AND ABBREVIATIONS
FIRE PROTECTION DETAILS FP12
FIRE PROTECTION EQUIPMENT SCHEDULE FP11
FIRE PROTECTION RISER FP10
DETAILS AND SCHEDULE FP09
WASH BUILDING FP08
SECOND FLOOR PLAN FP07
FIRST FLOOR PLAN FP06
YARD LEVELFLOOR PLAN - 2 FP05
YARD LEVELFLOOR PLAN - 1 FP04
ZONE LAYOUT PLAN FP03
GPM PER SQ FT AND 1500 SQ FT PROTECTION AREA. SPRINKLER HEAD COVERAGE OF 130 SQ FT IN COMPLIANCE WITH NFPA 13,
AUTHORITIES HAVING JURISDICTION.
OF THE WORK OF ALL OTHER TRADES WHICH MAY REQUIRE COORDINATION.
ARRANGEMENT. THE CONTRACTOR SHALL FABRICATE PIPING SYSTEM BASED ON FIELD MEASUREMENTS TO ENSURE THE PROPER ROUTING
AND FIT.
MARSHALL, OR AUTHORITY HAVING JURISDICTION.
ANY CONFLICT, OMISSIONS OR DISCREPANCIES.
AND SHALL PROVIDE ALL REQUIRED OFFSETS IN PIPING TO ACCOMPLISH THE WORK AT NO ADDITIONAL COST TO THE OWNER.
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH NFPA 13, NFPA 14, AND NFPA 20. 1.
SPRINKLER WATER DEMAND SHALL BE BASED ON ORDINARY HAZARD (GROUP 1) OCCUPANCY REQUIREMENTS. WATER DENSITY OF 0.15 2.
THE SPRINKLER CONTRACTOR SHALL OBTAIN A FULL SET OF PLANS AND SPECIFICATIONS FOR THIS PROJECT AND SHALL BE AWARE 3.
ALL FIRE PROTECTION PLANS ARE DIAGRAMMATIC IN FORM AND ARE FOR INFORMATION ONLY TO SHOWPOTENTIAL FIELD 4.
SPRINKLER CONTRACTOR SHALL PROVIDE HYDRAULIC CALCULATIONS FOR SIZING THE SPRINKLERS, SHALL BE APPROVED BY FIRE 5.
SPRINKLER CONTRACTOR IS REQUIRED TO INSPECT THE SITE AND ALL RELATED DOCUMENTS PRIOR TO START OF WORK. 6.
SPRINKLER CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BEGINNING WORK AND SHALL NOTIFY THE OWNER OF 7.
CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND PAY ALL FEES RELATIVE TO THE INSTALLATION OF HIS WORK. 8.
INSTALL DRAIN VALVE AT EVERY LOWPOINT ON HORIZONTAL PIPING. 9.
IT SHALL BE THE RESPONSIBILITY OF THE SPRINKLER CONTRACTOR TO COORDINATE HIS WORK WITH THAT OF ALL OTHER TRADES 10.
INSTALL HORIZONTAL PIPING WITH MINIMUM PITCH OF ONE INCH IN 40 FEET. 11.
INSTALL SLEEVES WHERE VERTICAL PIPING PASSING THROUGH ANY SLAB. 12.
PROTECTION NOTES, SYMBOLS & ABBREVIATIONS
DECEMBER 2013
BK
DP
LJ

FP-L01
162 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
5
4
4
\
1
0
4
2
p
F
P
L
A
0
2
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
AREA/LOCATION SYSTEM
OCCUPANCY
ZONE
WET LH
CLASSIFICATION
DENSITY
GPM/SF
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
0.10 2
OHGR-1
WET
WET
WET
WET ELEVATOR LOBBY
YARD STORAGE
OHGR-1
OHGR-1
LH
LH
LH
LH
LH
LH
LH
LH
0.10
0.10
0.15
0.15
0.20
0.10 3
0.10
0.10
0.10
0.10
0.10
0.15
0.15
0.15
0.15
WET
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
NO.
ROOM
OHGR-1
OHGR-1
OHGR-2
OHGR-1
UNISEX TOILET ROOM
BREAK ROOM
LIGHT RAIL
2
2
2
2
2
2
LIGHT RAIL OFFICE
3
3
3
3
3
3
3
3
MAINTENANCE STORAGE
LIGHT RAIL
SUPPLY STORAGE
CLEANING
ELECTRICAL ROOM
BULK FLUID STORAGE
UNISEX TOILET ROOM
UNISEX TOILET ROOM
CORRIDOR
CLEANING BREAK ROOM
CLEANING OFFICE
CORRIDOR
WATER SERVICE
ELECTRICAL SERVICE
ELECTRICAL SERVICE
EMERGENCY
WET
WET
118
119
WET OHGR-1 0.15 3
WASH BAY
ELECTRICAL
COMM. CLOSET
AT YARD LEVEL
STAIR #1
AREA/LOCATION SYSTEM
OCCUPANCY
ZONE
WET
CLASSIFICATION
DENSITY
GPM/SF
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
OHGR-1
WET
WET
WET
WET
FIRST FLOOR
OHGR-1
OHGR-1
LH
LH
LH
LH
LH
LH
LH
0.10
0.10
0.15
0.20
0.10
0.10
0.10
0.10
0.10
0.10
0.15
0.15
0.15
0.15
WET
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
NO.
ROOM
OHGR-1
8
TRANS. SUPERVISOR
WET
WET
216
217
WET
WET INCIDENT ROOM
218
219
CORRIDOR
AREA/LOCATION SYSTEM
OCCUPANCY
ZONE
WET
CLASSIFICATION
DENSITY
GPM/SF
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
WET
SECOND FLOOR
OHGR-1
LH
LH
LH
LH
LH
0.15
0.15
0.15
0.10
0.10
0.15
0.15
WET
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
NO.
ROOM
OHGR-1
OHGR-1
9
CORRIDOR
WET
WET
316
317
WET 0.15
WET
318
319
CORRIDOR
S1
S1
S2
LEVEL/ FIRST FLOOR
STAIR #1 AT DECK
LEVEL/ FIRST FLOOR
STAIR #2 AT DECK
S1
S2
SECOND FLOOR
STAIR #1 AT
SECOND FLOOR
STAIR #2 AT
WET 220
WET 221
WET 222
WET 223
WET 0.15 224
WET 0.10 225
WET 0.15 226
WET 227
WET 228
WET 229
WET 230
WET 231
WET 232
WET 233
WET 234
WET 235
WET JANITOR CLOSET 236
WET 0.15 237
VESTIBULE
LOBBY
I.T.
CORRIDOR
CORRIDOR
ADMIN./ COPY
SUPERVISOR
ASST. TRANS.
COORDINATOR
WORK BLOCK
TEAM ROOM
UNISEX TOILET ROOM
ELECTRICAL
MECHANICAL
EQUIPMENT
DISPATCH
CORRIDOR
TEAM ROOM
YARD MASTER
SUPERVISOR
UNISEX TOILET ROOM
OFFICE
TECHNICIANS
CONTROL ROOM
CORRIDOR
EQUIPMENT
UNISEX TOILET ROOM
CORRIDOR
QUIET ROOM
VESTIBULE
WOMEN'S TOILET ROM
CORRIDOR
LOCKERS
MEN'S TOILET ROOM
ROOM/ KITCHENETTE
OPERATOR BREAK
MAINTENANCE
BUILDING
LH 8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
LH
LH
OHGR-1 0.10
LH
LH
LH
LH
LH
LH
LH
LH
LH
OHGR-1
OHGR-1
OHGR-1
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
8 LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
LH
WET 320
AREA/LOCATION SYSTEM
OCCUPANCY
ZONE
WET
CLASSIFICATION
DENSITY
GPM/SF NO.
ROOM
S1
AT PENTHOUSE
STAIR #1
PENTHOUSE
ELEVATOR LOBBY
CORRIDOR
CORRIDOR
UNISEX TOILET ROOM
ADMIN./ COPY
DEPUTY DIRECTOR
LIGHT RAIL
LIGHT RAIL DIRECTOR
INCIDENT ROOM
I.T.
CONFERENCE
ELECTRICAL
MECHANICAL
UNISEX TOILET ROOM
UNISEX TOILET ROOM
JANITOR CLOSET
CORRIDOR
STORAGE
CLASS ROOM
LH
LH
LH
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
0.10
0.10
0.10
0.10
0.10
0.10
OHGR-1
OHGR-1
LH
LH
LH
LH
LH
LH
OHGR-1
LH 0.10
0.10
0.10
0.10
0.10
0.10
0.10
OHGR-1 0.15 9
OHGR-1 0.15 9
0.15 9 OHGR-1
OHGR-1 0.15 8
OHGR-1 0.15 8
OHGR-1 0.15 3
OHGR-1 0.15 3
OHGR-1 0.15 3
OHGR-1 0.15 3
TRAINING OFFICE
BETWEEN THE DRY PIPE SPRINKLER RISER AND THE QUICK-OPENING DEVICE.
- A LISTED ANTI-FLOODING DEVICE SHALL BE INSTALLED IN THE CONNECTION
AND THE INTERMEDIATE CHAMBER OF THE DRY PIPE VALVE.
- A CHECK VALVE SHALL BE INSTALLED BETWEEN THE QUICK-OPENING DEVICE
BETWEEN DRY PIPE SPRINKLER RISER AND QUICK-OPENING DEVICE.
- A SOFT DISC GLOBE OR ANGIE VALVE SHALL BE INSTALLED IN THE CONNECTION
DEVICE WHERE CAPACITY EXCEEDS 500 GAL.
- DRY PIPE VALVES SHALL BE PROVIDED WITH A LISTED QUICK-OPENING
- GRIDDED DRY PIPE SYSTEM SHALL NOT BE INSTALLED.
BY ONE DRY PIPE VALVE.
- NOT MORE THAN 750 GAL. SYSTEM CAPACITY SHALL BE CONTROLLED
- ONLY UPRIGHT SPRINKLERS SHALL BE INSTALLED ON DRY PIPE.
: NOTE
SYSTEM = DRY
DENSITY = 0.15 GPM/SQ. FT
OH-GP-I
HAZARD / OCCUPANCY CLASSIFICATION
ZONE #4, 5 & 6
DESIGN CRITERIA AND HAZARD CLASSIFICATION
DECEMBER 2013
BK
DP
LJ

FP-L02
163 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
F
i r
e

P
r
o
t
e
c
t
i o
n
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
F
P
L
A
0
3
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
SCALE: SCALE: 1" = 40'
ZONES LAYOUT PLAN
ZONE#1
ZONE#2 ZONE#3
ZONE#7
ZONE#4 ZONE#5 ZONE#6
30' 30' 0 60'
SCALE:1"=30'
ZONES LAYOUT PLAN
DECEMBER 2013
BK
DP
LJ

FP-L03
164 1"=40'
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
A
B
C
D
15.1 7.1 23.1
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
2
/
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
F
i r
e

P
r
o
t
e
c
t
i o
n
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
F
P
L
A
0
4
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
SCALE:
YARD LEVEL PLAN - FIRE PROTECTION (SHEET 1 OF 2)
1" ="
ZONE#2
ZONE#3
PART OF ZONE#6
PART OF ZONE#5
8' 8' 0 16'
SCALE:"=1'-0"
YARD LEVEL FIRE PROTECTION PLAN
DECEMBER 2013
BK
DP
LJ

FP-L04
165 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
SUPPLY STORAGE
CLEANING
STORAGE
BULK FLUID
100
T.R.
UNISEX
101
ROOM
BREAK
L.R.
102
OFFICE
L.R.
103
STORAGE
L.R. MAINT.
104
105
ELEC.
106
107
PROTECT.
FIRE
121
ROOM
COMPRESSOR
12 13 14 15 16 17 18 19 20 15.1 12 13 14 15 16 17 18 19 20 15.1 12 13 14 15 16 17 18 19 20 15.1
M
A
T
C
H

L
I
N
E
AIR COMPRESSOR
4 WATTS / FOOT
& HEAT TRACED @
6"FIRE MAIN INSULATED
(DRY-PIPE VALVE)
VALVE CONTROL ZONE
ZONE-5
DRY SPRINKLERS
ZONE-2
TO SPRINKLERS
ZONE CONTROL VALVE
BFP
CORRIDOR
BREAK ROOM
CLEANING
E-3
SERVICE
WATER
SERVICE
ELECTRICAL
SERVICE
ELECTRICAL
EMERGENCY
108
PROTECT.
FIRE
111
109
T.R.
UNISEX 110
T.R.
UNISEX
112
113
OFFICE
CLEANING
S2
S2-1
STAIR
114
ELEV.
115 116
20 21 22 23 24 25 26 27 23.1 20 21 22 23 24 25 26 27 23.1 20 21 22 23 24 25 26 27 23.1
M
A
T
C
H

L
I
N
E
4 WATTS / FOOT
& HEAT TRACED @
6"FIRE MAIN INSULATED
FHV
BFP
ZONE-3A
DRY SPRINKLERS
AIR COMPRESSOR
INCOMING
8"WATER MAIN
WATER MAIN
DOMESTIC
6"
ZONE #3
SPRINKLERS
OF THE BUILDING
FLOOR 2ND TO UP 4"
VALVE
ZONE CONTROL
VALVE (DRY-PIPE VALVE)
ZONE CONTROL
VALVE
ZONE CONTROL
ZONE-6
DRY SPRINKLERS
6"
4"
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
2
6
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
F
i r
e

P
r
o
t
e
c
t
i o
n
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
F
P
L
A
0
5
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
SCALE:
YARD LEVEL PLAN - FIRE PROTECTION (SHEET 2 OF 2)
" = 1'-0"
8' 8' 0 16'
SCALE:"=1'-0"
YARD LEVEL FIRE PROTECTION PLAN
DECEMBER 2013
BK
DP
LJ

FP-L05
166 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
4 WATTS / FOOT
& HEAT TRACED @
6"FIRE MAIN INSULATED
REQUIRED PER NFPA-13
WITH ALL ACCESSORIES
DRY PIPE VALVE ASSEMBLY
ZONE -1
CONTROL VALVE
AIR COMPRESSOR
ZONE-1
TO SPRINKLERS
SYSTEM = WET
DENSITY = 0.15 GPM/SQ. FT
OH-GP-I
CLASSIFICATION
HAZARD/OCCUPANCY
FHV
ZONE-1
SPRINKLERS
120
PROTECT.
FIRE
1 2 3 4 5 6
A
PROTECT.
FIRE
1 2 3 4 5 6
A
KEY PLAN
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
AA
A
B
C
A.3
A.4
A.8
B.6
B.8
B.5
24 25 26 27
C
B.8
C.8
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
5
4
4
\
1
0
4
2
p
F
P
L
A
0
6
.
d
g
n
Maryland
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
24 25 26 27
KEY PLAN
UP
DN
DN
UP
201
LOBBY
S2-3
STAIR
ROOM
TEAM
VEST.
ELEV.
I.T.
CORR.
MASTER
YARD
ROOM
INCIDENT
CORR.
CORR.
CORR.
CORR.
S2
S3-1
STAIR
SUPER.
TRANS.
COPY
ADMIN./
SUPER.
TRANS.
ASST.
COORD.
WORK BLK
CORR.
ROOM
TEAM
VEST.
T.R.
UNISEX
ELEC.
MECH.
EQUIP.
LOST/FND
DISPATCH
CONTROL CNTR
OPERATIONS
SUPER.
T.R.
UNISEX
OFFICE
TECH.
ROOM
QUIET
T.R.
UNISEX
CORR.
T.R.
WOMENS
LOCKERS
233
S3
228
227
229
214
231
214A
230
213
211
212
224
225
209
210
204
208
207
206 205
200
202
216
217
220
221 222
218 219
223
215
E-3
203
EQUIP.
226













TO ZONE-8
SPRINKLERS
MAIN
4" FIRE
ZONE-8
CONTROL VALVE
4" RISER
CHECK VALVE
FHV
ZONE-8
CONTROL VALVE
CHECK VALVE
FHV
FIRE RISER
TO ZONE-8
SPRINKLERS
MAIN
4" FIRE
MAIN
4" FIRE
MATCH LINE
UP
UP
CORR.
S3-1
STAIR
T.R.
WOMENS
LOCKERS
MAINT.
BLDG.
KITCHENETTE
OPER. BRK RM/
237
236
232
233
235
S3
228
227

CL.
JAN.
T.R.
MENS
234

ZONE-8
CONTROL VALVE
CHECK VALVE
FHV
FIRE RISER
TO ZONE-8
SPRINKLERS
MAIN
4" FIRE
MATCH LINE
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
architect under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
443
24'-0" 24'-0" 24'-0"
72'-0"
N
8' 8' 0 16'
SCALE: 1/8"=1'-0"
OFFICE FIRST FLOOR PLAN - FIRE PROTECTION
SCALE: " = 1'-0"
ZONE#8
ZONE#8
OFFICE FIRST FLOOR PLAN - FIRE PROTECTION
DECEMBER 2013
MB
DP
LJ

FP-L06
167 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
24 25 26 27
AA
A
B
C
A.3
A.4
A.8
B.6
B.8
B.5
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
9
/
2
0
1
3
p
w
:
\
\
0
0

-

C
u
r
r
e
n
t

P
r
o
j
e
c
t
s
\
1
0
4
2

-

P
u
r
p
l e

L
i n
e

L
i g
h
t

R
a
i l \
1
3
0

G
E
C

C
A
D
D

F
i l e
s
\
Z
o
n
e

1
0
\
S
t
r
u
c
t
u
r
e
s
\
A
-
L
y
t
t
o
n
s
v
i l l e

Y
a
r
d

a
n
d

S
h
o
p
\
F
i r
e

P
r
o
t
e
c
t
i o
n
\
S
h
e
e
t

F
i l e
s
\
1
0
4
2
p
F
P
L
A
0
7
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
24 25
AA
A
24 25
AA
A
N
SCALE: " = 1'-0"
OFFICE SECOND FLOOR PLAN - FIRE PROTECTION
SCALE:
ROOF STAIR PLAN - FIRE PROTECTION
= 1'=0"
ZONE#9
ZONE#10
8' 8' 0 16'
SCALE:"=1'-0"

OFFICE SECOND FLOOR PLAN-FIRE PROTECTION
DECEMBER 2013
BK
DP
LJ

FP-L07
168 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
CHECK VALVE
FHV
4" RISER
TO ZONE-9
SPRINKLERS
ZONE-9
CONTROL VALVE
TO ZONE-9
SPRINKLERS
CHECK VALVE
FIRE MAIN RISER
FHV
ZONE-9
CONTROL VALVE
COPY
ADMIN./
304
303
T.R.
UNISEX
307
302
305 CORR.
DIRECTOR
L.R. DEP.
ROOM
INCIDENT
306
DIR.
L.R.
308
I.T.
CORR.
301
ELEC.
311
312
ROOM
COMM.
CORR.
310
313
MECH.
314
315
316
CORR.
T.R.
UNISEX
T.R.
UNISEX
STOR.
319 318
CLASSROOM
320
OFFICE
TRAIN.
321
S3-2
STAIR
S3
ELEV.
E-3
S2-4
STAIR
S2
LOBBY
ELEV.
300
309
CONF.
JAN. CL.
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
KEY PLAN
443
S2-4
STAIR
S2

FHV
ZONE-10
TO SPRINKLERS
VALVE
CONTROL
ZONE
4" RISER
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
5
4
4
\
1
0
4
2
p
F
P
L
A
0
8
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
N
SCALE:
WASH BUILDING FLOOR PLAN
"=1'-0"
ZONE#5
ZONE#7
8' 8' 0 16'
SCALE:"=1'-0"
WASH BUILDING PLAN - FIRE PROTECTION
DECEMBER 2013
BK
DP
LJ

FP-L08
169 1/8"=1'-0"
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443
KEY PLAN
SYSTEM = WET
DENSITY = 0.20 GPM/SQ. FT
OH-GP-I
HAZARD/OCCUPANCY CLASSIFICATION
4 WATTS / FOOT
& HEAT TRACED @
4"FIRE MAIN INSULATED
117
WASH BAY
118
ELEC.
119
COMM. CL.
ELEC. COMM. CL.
TRAIN WASH
FHV
ZONE-7
DRY SPRINKLERS
ZONE-7
CONTROL VALVE
MARYLAND DEPARTMENT OF TRANSPORTATION
ADMINISTRATION
MARYLAND TRANSIT
DATE: SCALE: OF
DRAWING NO.
CONTRACT NO.
SHEET NO.
1
1
/
1
3
/
2
0
1
3
c
:
\
p
w
w
o
r
k
i n
g
\
m
t
a
p
w
\
w
r
a
-
r
y
a
n

h
a
u
s
m
a
n
n
\
d
m
s
9
3
5
4
4
\
1
0
4
2
p
F
P
L
A
0
9
.
d
g
n
Maryland
PROFESSIONAL CERTIFICATION
License No. Expiration Date
the State of Maryland
engineer under the laws of
am a duly licensed professional
approved by me, and that I
documents were prepared or
I hereby certify that these
A
P
P
R
C
H
E
C
K
D
R
A
W
N
D
E
S
G
N
of its draft status.
any of these plans is made with full understanding
the completion of the design phase. Any reliance upon
further revision pending refinements to the plans during
preliminary engineering plans and may be subject to
DRAFT: Information shown is based on 30 percent
E
D SILVER SPRING, MARYLAND
DIVERSIFIED ENGINEERING, INC.
ROOF
YARD STORAGE LEVEL
FIRST FLOOR
SECOND FLOOR
SCALE:
FIRE PROTECTION RISER
NTS
F
FHV
ZONE-1
VALVE
CONTROL
ZONE-4
VALVE
DRY-PIPE
DV
PANEL
CONTROL
PIPE MOUNTED
AIR COMPRESSOR
4"
HEAT TRACED
AND INSULATED
MAIN FIRE 6"
HEAT TRACED
AND INSULATED
MAIN FIRE 6"
FIRE ALARM
FROM
F
FHV
ZONE-2
VALVE
CONTROL
DV
F
FHV
ZONE-3
VALVE
CONTROL
DV
4" 4"
4"
ZONE-5
VALVE
DRY-PIPE
PANEL
CONTROL
PIPE MOUNTED
AIR COMPRESSOR
FIRE ALARM
FROM
ZONE-6
VALVE
DRY-PIPE
PANEL
CONTROL
PIPE MOUNTED
AIR COMPRESSOR
4"
FIRE ALARM
FROM
4"
BFP
ZONE-3A
VALVE
CONTROL
FHV
DV
ZONE-8
VALVE
CONTROL
ZONE-8
VALVE
CONTROL CV CV
8" WATER MAIN
DOMESTIC WATER
ZONE-9
VALVE
CONTROL
ZONE-9
VALVE
CONTROL
CV CV
4"
4"
4"
FHV FHV
FHV
SP SPRINKLERS
ZONE-4
TO SP
ZONE-2
TO SP
ZONE-3
TO SP
ZONE-5
TO SP
ZONE-6
TO SP
ZONE-1
TO SP
4"
YARD YARD YARD F
FHV
ZONE-7
VALVE
CONTROL
DV
4"
ZONE-7
TO SP
WASH BUILDING
STAIR S2-2 STAIR S3-1
STAIR S3-2 STAIR S2-3
PARKING
STAIR S2-1
FHV
ZONE-10
VALVE
CONTROL
4"
4"
MAIN
FIRE 6"
FIRE PROTECTION RISER
DECEMBER 2013
BK
DP
LJ

FP-L09
170 NTS
LYTTONSVILLE YARD FACILITY
T-1042-0220
PRELIMINARY ENGINEERING
PURPLE LINE LIGHT RAIL
443

You might also like