Flextable: Pipe Table (Red de Agua Sector 03.Wtg) Active Scenario: Verificacion Hidraulica de Redes de Agua Potable Sector 03

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Active Scenario: VERIFICACION HIDRAULICA DE REDES DE AGUA POTABLE SECTOR 03

FlexTable: Pipe Table (red de agua sector 03.wtg)


Current Time: 0.000 hours
Label

Start Node

P-1
RAE 05 SAHAUNAY
P-2
J-8
P-3
J-10
P-4
J-12
P-5
J-14
P-8
J-18
P-9
J-20
P-10
J-23
P-11
J-25
P-12
J-27
P-13
J-28
P-14
J-30
P-15
J-32
P-16
J-35
P-17
J-36
P-18
J-39
P-19
J-40
P-20
J-29
P-21
J-44
P-22
J-26
P-23
J-47
P-24
J-49
P-25
J-50
P-26
J-52
P-27
J-55
P-28
J-32
P-29
J-38
P-30
J-43
P-31
J-6003.wtg
red
de agua sector
SETARIP
S.R.LJ-63
P-32
P-33
J-64
P-34
J-48
P-35
J-67
P-36
J-68
P-37
J-22
P-38
J-71
P-39
J-74

Stop Node

J-175
J-7
J-9
J-11
J-13
J-2
J-21
J-22
J-24
J-26
J-29
J-31
J-33
J-34
J-37
J-38
J-41
J-42
J-43
J-45
J-46
J-48
J-51
J-53
J-54
J-56
J-58
J-59
J-61
J-62
J-18
J-65
J-66
J-69
J-70
J-72
J-73

Diameter
(mm)
185.4
99.4
102.0
99.4
99.4
81.4
99.4
148.4
81.4
148.4
99.4
83.4
100.0
83.4
81.4
81.4
81.4
99.4
144.6
81.4
148.4
99.4
83.4
83.4
83.4
100.0
81.4
99.4
99.4
148.4
81.4
83.4
99.4
83.4
99.4
83.4
148.4

Material

Length
(Scaled)
(m)

HazenWilliams
C

Flow
(L/s)

Velocity
(m/s)

PVC
537.09
150.0
19.17
0.71
PVC
1.09
150.0
1.17
0.15
PVC
1.29
150.0
1.96
0.24
PVC
1.33
150.0
1.30
0.17
PVC
1.37
150.0
0.39
0.05
PVC
2.32
150.0
0.02
0.00
PVC
2.44
150.0
0.16
0.02
PVC
2.63
150.0
0.43
0.03
PVC
2.67
150.0
0.32
0.06
PVC
2.69
150.0
1.05
0.06
PVC
2.86
150.0
2.63
0.34
PVC
2.88
150.0
0.02
0.00
PVC
2.96
150.0
0.12
0.02
PVC
3.09
150.0
2.01
0.37
PVC
3.10
150.0
0.81
0.15
PVC
3.17
150.0
3.09
0.59
PVC
3.26
150.0
0.04
0.01
PVC
3.36
150.0
2.53
0.33
PVC
3.40
150.0
0.45
0.03
PVC
3.53
150.0
1.05
0.20
PVC
3.63
150.0
0.71
0.04
PVC
3.67
150.0
0.04
0.01
PVC
3.96
150.0
0.00
0.00
PVC
4.00
150.0
1.83
0.33
PVC
4.07
150.0
0.02
0.00
PVC
4.13
150.0
0.06
0.01
PVC
4.36
150.0
0.26
0.05
PVC
4.45
150.0
0.06
0.01
PVC Bentley Systems, Inc. 4.74
150.0Solution 0.20
0.03
Haestad Methods
Center
27
Siemon Company Drive Suite
200 W Watertown,
PVC
4.84
150.0 CT 06795
6.41 USA +1-0.37
203-755-1666
PVC
4.98
150.0
0.02
0.00
PVC
5.10
150.0
0.02
0.00
PVC
5.29
150.0
0.77
0.10
PVC
5.46
150.0
0.00
0.00
PVC
5.57
150.0
0.01
0.00
PVC
6.14
150.0
0.22
0.04
PVC
6.14
150.0
0.14
0.01

Headloss
Gradient
(m/km)
2.412
0.273
0.691
0.336
0.000
0.000
0.061
0.057
0.111
0.000
1.249
0.000
0.000
1.833
0.384
4.511
0.000
1.196
0.000
0.633
0.000
0.000
0.000
1.488
0.000
0.000
0.068
0.000
0.000
0.923
0.000
0.000
0.141
0.000
0.000
0.024
0.000

Headloss
(m)
1.295
0.000
0.001
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.004
0.000
0.000
0.006
0.001
0.014
0.000
0.004
0.000
0.002
0.000
0.000
0.000
0.006
0.000
0.000
0.000
0.000
0.000
0.004
0.000
0.000
0.001
0.000
0.000
0.000
0.000

Bentley WaterCAD V8i


[08.11.00.30]
Page 1 of 8

P-15
J-32
J-33
100.0 PVC
2.96
150.0
0.12
0.02
0.000
0.000
P-16
J-35
J-34
83.4 PVC
3.09
150.0
2.01
0.37
1.833
0.006
P-17
J-36
J-37
81.4 PVC
3.10
150.0
0.81
0.15
0.384
0.001
P-18
J-39
J-38
81.4 PVC
3.17
150.0
3.09
0.59
4.511
0.014
P-19
J-40
J-41
81.4 PVC
3.26
150.0
0.04
0.01
0.000
0.000
P-20
J-29
J-42
99.4 PVC
3.36
150.0
2.53
0.33
1.196
0.004
P-21
J-44
J-43
144.6 PVC
3.40
150.0
0.45
0.03
0.000
0.000
Active Scenario:
VERIFICACION
HIDRAULICA
DE
REDES
POTABLE
SECTOR 03
P-22
J-26
J-45
81.4 PVC
3.53
150.0
1.05 DE AGUA
0.20
0.633
0.002
P-23
J-47
J-46
148.4 PVC
3.63
150.0
0.71
0.04
0.000
0.000
FlexTable:
Pipe Table 3.67
(red de
agua 0.04
sector0.01
03.wtg)
P-24
J-49
J-48
99.4 PVC
150.0
0.000
0.000
P-25
J-50
J-51
83.4 PVC
3.96
150.0
0.00
0.00
0.000
0.000
Current
Time: 0.0004.00
hours150.0
P-26
J-52
J-53
83.4 PVC
1.83
0.33
1.488
0.006
P-27
J-55 Start Node
J-54
83.4 PVC Material
4.07
150.0
0.02 Velocity
0.00 Headloss
0.000
0.000
Label
Stop Node
Diameter
Length
HazenFlow
Headloss
P-28
J-32
J-56
100.0
PVC
4.13
150.0
0.06
0.01
0.000
(mm)
(Scaled)
Williams
(L/s)
(m/s)
Gradient
(m)0.000
(m)4.36
C
(m/km)
P-29
J-38
J-58
81.4 PVC
150.0
0.26
0.05
0.068
0.000
P-30
J-43
J-59
99.4 PVC
4.45
150.0
0.06
0.01
0.000
0.000
P-31
J-60
J-61
99.4 PVC
4.74
150.0
0.20
0.03
0.000
0.000
P-32
J-63
J-62
148.4 PVC
4.84
150.0
6.41
0.37
0.923
0.004
P-33
J-64
J-18
81.4 PVC
4.98
150.0
0.02
0.00
0.000
0.000
P-34
J-48
J-65
83.4 PVC
5.10
150.0
0.02
0.00
0.000
0.000
P-35
J-67
J-66
99.4 PVC
5.29
150.0
0.77
0.10
0.141
0.001
P-36
J-68
J-69
83.4 PVC
5.46
150.0
0.00
0.00
0.000
0.000
P-37
J-22
J-70
99.4 PVC
5.57
150.0
0.01
0.00
0.000
0.000
P-38
J-71
J-72
83.4 PVC
6.14
150.0
0.22
0.04
0.024
0.000
P-39
J-74
J-73
148.4 PVC
6.14
150.0
0.14
0.01
0.000
0.000
P-40
J-62
J-75
148.4 PVC
6.16
150.0
4.24
0.24
0.435
0.003
P-41
J-77
J-76
99.4 PVC
6.29
150.0
0.78
0.10
0.118
0.001
P-42
J-78
J-79
57.0 PVC
6.59
150.0
0.02
0.01
0.000
0.000
P-43
J-80
J-67
83.4 PVC
6.36
150.0
0.77
0.14
0.304
0.002
P-44
J-81
J-82
81.4 PVC
6.38
150.0
0.00
0.00
0.000
0.000
P-45
J-27
J-23
148.4 PVC
6.55
150.0
5.18
0.30
0.613
0.004
P-46
J-83
J-84
99.4 PVC
6.55
150.0
0.87
0.11
0.159
0.001
P-47
J-28
J-85
99.4 PVC
6.65
150.0
0.71
0.09
0.112
0.001
P-48
J-34
J-52
83.4 PVC
6.79
150.0
1.93
0.35
1.688
0.011
P-49
J-87
J-86
148.4 PVC
7.13
150.0
4.11
0.24
0.418
0.003
P-50
J-88
J-28
99.4 PVC
7.15
150.0
3.34
0.43
1.977
0.014
P-51
J-89
J-90
99.4 PVC
7.15
150.0
0.25
0.03
0.021
0.000
P-52
J-74
J-91
148.4 PVC
7.42
150.0
0.12
0.01
0.000
0.000
P-53
J-92
J-93
102.0 PVC
13.47
150.0
0.14
0.02
0.011
0.000
P-54
J-89
J-94
99.4 PVC
8.38
150.0
0.00
0.00
0.000
0.000
P-55
J-95
J-14
99.4 PVC
8.51
150.0
0.43
0.05
0.035
0.000
P-56
J-25
J-78
81.4 PVC
8.75
150.0
0.35
0.07
0.085
0.001
P-57
J-96
J-97
57.0 PVC
8.77
150.0
0.04
0.02
0.000
0.000
Bentley WaterCAD V8i
P-58
J-9503.wtg
J-98
99.4 PVC Bentley Systems, Inc. 8.89
150.0Solution 1.00
0.13
0.201
0.002
[08.11.00.30]
red
de agua sector
Haestad Methods
Center
SETARIP
S.R.LJ-99
Siemon Company Drive Suite
200 W Watertown,
Page 2 of 8
P-59
J-100
185.4 27
PVC
9.30
150.0 CT 06795
0.24 USA +1-0.01
0.000
0.000
203-755-1666
P-60
J-85
J-101
99.4 PVC
9.53
150.0
0.53
0.07
0.062
0.001
P-61
J-30
J-102
99.4 PVC
12.43
150.0
0.32
0.04
0.024
0.000
P-62
J-92
J-103
102.0 PVC
10.50
150.0
1.77
0.22
0.539
0.006
P-63
J-105
J-104
81.4 PVC
10.32
150.0
0.08
0.02
0.000
0.000
P-64
J-106
J-107
81.4 PVC
10.84
150.0
0.06
0.01
0.000
0.000
P-65
J-90
J-108
83.4 PVC
10.71
150.0
0.25
0.05
0.042
0.000
P-66
J-109
J-35
148.4 PVC
10.78
150.0
2.03
0.12
0.110
0.001

P-42
J-78
J-79
57.0 PVC
6.59
150.0
0.02
0.01
0.000
0.000
P-43
J-80
J-67
83.4 PVC
6.36
150.0
0.77
0.14
0.304
0.002
P-44
J-81
J-82
81.4 PVC
6.38
150.0
0.00
0.00
0.000
0.000
P-45
J-27
J-23
148.4 PVC
6.55
150.0
5.18
0.30
0.613
0.004
P-46
J-83
J-84
99.4 PVC
6.55
150.0
0.87
0.11
0.159
0.001
P-47
J-28
J-85
99.4 PVC
6.65
150.0
0.71
0.09
0.112
0.001
P-48
J-34
J-52
83.4 PVC
6.79
150.0
1.93
0.35
1.688
0.011
Active Scenario:
VERIFICACION
HIDRAULICA
DE
REDES
POTABLE
SECTOR 03
P-49
J-87
J-86
148.4 PVC
7.13
150.0
4.11 DE AGUA
0.24
0.418
0.003
P-50
J-88
J-28
99.4 PVC
7.15
150.0
3.34
0.43
1.977
0.014
FlexTable:
Pipe Table 7.15
(red de
agua 0.25
sector0.03
03.wtg)
P-51
J-89
J-90
99.4 PVC
150.0
0.021
0.000
P-52
J-74
J-91
148.4 PVC
7.42
150.0
0.12
0.01
0.000
0.000
Current
Time: 0.000
hours150.0
P-53
J-92
J-93
102.0 PVC
13.47
0.14
0.02
0.011
0.000
P-54
J-89 Start Node
J-94
99.4 PVC Material
8.38
150.0
0.00 Velocity
0.00 Headloss
0.000
0.000
Label
Stop Node
Diameter
Length
HazenFlow
Headloss
P-55
J-95
J-14
99.4
PVC
8.51
150.0
0.43
0.05
0.035
(mm)
(Scaled)
Williams
(L/s)
(m/s)
Gradient
(m)0.000
(m)8.75
C
(m/km)
P-56
J-25
J-78
81.4 PVC
150.0
0.35
0.07
0.085
0.001
P-57
J-96
J-97
57.0 PVC
8.77
150.0
0.04
0.02
0.000
0.000
P-58
J-95
J-98
99.4 PVC
8.89
150.0
1.00
0.13
0.201
0.002
P-59
J-99
J-100
185.4 PVC
9.30
150.0
0.24
0.01
0.000
0.000
P-60
J-85
J-101
99.4 PVC
9.53
150.0
0.53
0.07
0.062
0.001
P-61
J-30
J-102
99.4 PVC
12.43
150.0
0.32
0.04
0.024
0.000
P-62
J-92
J-103
102.0 PVC
10.50
150.0
1.77
0.22
0.539
0.006
P-63
J-105
J-104
81.4 PVC
10.32
150.0
0.08
0.02
0.000
0.000
P-64
J-106
J-107
81.4 PVC
10.84
150.0
0.06
0.01
0.000
0.000
P-65
J-90
J-108
83.4 PVC
10.71
150.0
0.25
0.05
0.042
0.000
P-66
J-109
J-35
148.4 PVC
10.78
150.0
2.03
0.12
0.110
0.001
P-67
J-45
J-70
81.4 PVC
12.24
150.0
0.50
0.10
0.158
0.002
P-68
J-111
J-110
81.4 PVC
11.39
150.0
1.70
0.33
1.490
0.017
P-69
J-112
J-15
57.0 PVC
11.71
150.0
0.00
0.00
0.000
0.000
P-70
J-110
J-77
81.4 PVC
12.45
150.0
0.80
0.15
0.371
0.005
P-71
J-75
J-87
148.4 PVC
12.68
150.0
4.24
0.24
0.434
0.006
P-72
J-115
J-114
148.4 PVC
16.01
150.0
0.69
0.04
0.019
0.000
P-73
J-116
J-117
81.4 PVC
16.10
150.0
0.00
0.00
0.000
0.000
P-74
J-118
J-119
83.4 PVC
17.02
150.0
0.08
0.01
0.009
0.000
P-75
J-121
J-120
81.4 PVC
17.37
150.0
0.00
0.00
0.000
0.000
P-76
J-122
J-123
81.4 PVC
18.47
150.0
0.28
0.05
0.048
0.001
P-77
J-45
J-124
81.4 PVC
18.06
150.0
0.54
0.10
0.173
0.003
P-78
J-124
J-125
81.4 PVC
21.39
150.0
0.21
0.04
0.035
0.001
P-79
J-127
J-126
148.4 PVC
19.42
150.0
6.36
0.37
0.920
0.018
P-80
J-128
J-39
144.6 PVC
26.76
150.0
9.98
0.61
2.419
0.065
P-81
J-129
J-4
81.4 PVC
20.98
150.0
0.01
0.00
0.000
0.000
P-82
J-125
J-122
81.4 PVC
21.00
150.0
0.14
0.03
0.014
0.000
P-83
J-126
J-27
148.4 PVC
21.43
150.0
6.34
0.37
0.924
0.020
P-84
J-130
J-63
148.4 PVC
21.52
150.0
6.41
0.37
0.941
0.020
Bentley WaterCAD V8i
P-85
J-108
J-69
83.4 PVC Bentley Systems, Inc.23.06
150.0Solution 0.25
0.05
0.039
0.001
[08.11.00.30]
red
de agua sector
03.wtg
Haestad Methods
Center
SETARIP
S.R.LJ-131
Siemon Company Drive Suite
200 W Watertown,
Page 3 of 8
P-86
J-40
81.4 27
PVC
24.03
150.0 CT 06795
0.06 USA +1-0.01
0.000
0.000
203-755-1666
P-87
J-132
J-133
57.0 PVC
33.06
150.0
0.18
0.07
0.135
0.004
P-88
J-81
J-134
57.0 PVC
25.14
150.0
0.04
0.02
0.012
0.000
P-89
J-102
J-20
99.4 PVC
25.42
150.0
0.45
0.06
0.047
0.001
P-90
J-135
J-44
99.4 PVC
25.75
150.0
0.47
0.06
0.052
0.001
P-91
J-137
J-138
81.4 PVC
25.99
150.0
0.02
0.00
0.000
0.000
P-92
J-85
J-106
99.4 PVC
27.23
150.0
0.16
0.02
0.005
0.000
P-93
J-139
J-140
81.4 PVC
27.40
150.0
0.10
0.02
0.011
0.000

P-69
J-112
J-15
57.0 PVC
11.71
150.0
0.00
0.00
0.000
0.000
P-70
J-110
J-77
81.4 PVC
12.45
150.0
0.80
0.15
0.371
0.005
P-71
J-75
J-87
148.4 PVC
12.68
150.0
4.24
0.24
0.434
0.006
P-72
J-115
J-114
148.4 PVC
16.01
150.0
0.69
0.04
0.019
0.000
P-73
J-116
J-117
81.4 PVC
16.10
150.0
0.00
0.00
0.000
0.000
P-74
J-118
J-119
83.4 PVC
17.02
150.0
0.08
0.01
0.009
0.000
P-75
J-121
J-120
81.4 PVC
17.37
150.0
0.00
0.00
0.000
0.000
Active Scenario:
VERIFICACION
HIDRAULICA
DE
REDES
POTABLE
SECTOR 03
P-76
J-122
J-123
81.4 PVC
18.47
150.0
0.28 DE AGUA
0.05
0.048
0.001
P-77
J-45
J-124
81.4 PVC
18.06
150.0
0.54
0.10
0.173
0.003
FlexTable:
Pipe Table21.39
(red de
agua 0.21
sector0.04
03.wtg)
P-78
J-124
J-125
81.4 PVC
150.0
0.035
0.001
P-79
J-127
J-126
148.4 PVC
19.42
150.0
6.36
0.37
0.920
0.018
Current
Time: 0.000
hours150.0
P-80
J-128
J-39
144.6 PVC
26.76
9.98
0.61
2.419
0.065
P-81
J-129Start Node
J-4
81.4 PVC Material
20.98
150.0
0.01 Velocity
0.00 Headloss
0.000
0.000
Label
Stop Node
Diameter
Length
HazenFlow
Headloss
P-82
J-125
J-122
81.4
PVC
21.00
150.0
0.14
0.03
0.014
(mm)
(Scaled)
Williams
(L/s)
(m/s)
Gradient
(m)0.000
(m)
C
(m/km)
P-83
J-126
J-27
148.4 PVC
21.43
150.0
6.34
0.37
0.924
0.020
P-84
J-130
J-63
148.4 PVC
21.52
150.0
6.41
0.37
0.941
0.020
P-85
J-108
J-69
83.4 PVC
23.06
150.0
0.25
0.05
0.039
0.001
P-86
J-131
J-40
81.4 PVC
24.03
150.0
0.06
0.01
0.000
0.000
P-87
J-132
J-133
57.0 PVC
33.06
150.0
0.18
0.07
0.135
0.004
P-88
J-81
J-134
57.0 PVC
25.14
150.0
0.04
0.02
0.012
0.000
P-89
J-102
J-20
99.4 PVC
25.42
150.0
0.45
0.06
0.047
0.001
P-90
J-135
J-44
99.4 PVC
25.75
150.0
0.47
0.06
0.052
0.001
P-91
J-137
J-138
81.4 PVC
25.99
150.0
0.02
0.00
0.000
0.000
P-92
J-85
J-106
99.4 PVC
27.23
150.0
0.16
0.02
0.005
0.000
P-93
J-139
J-140
81.4 PVC
27.40
150.0
0.10
0.02
0.011
0.000
P-94
J-62
J-141
148.4 PVC
27.66
150.0
2.13
0.12
0.124
0.003
P-95
J-47
J-115
148.4 PVC
27.95
150.0
3.95
0.23
0.383
0.011
P-96
J-142
J-49
99.4 PVC
27.96
150.0
0.07
0.01
0.000
0.000
P-98
J-145
J-146
81.4 PVC
28.17
150.0
0.34
0.07
0.074
0.002
P-99
J-148
J-147
99.4 PVC
28.53
150.0
0.00
0.00
0.000
0.000
P-100
J-116
J-30
83.4 PVC
29.74
150.0
0.36
0.07
0.075
0.002
P-101
J-71
J-150
83.4 PVC
30.45
150.0
0.00
0.00
0.000
0.000
P-102
J-146
J-81
81.4 PVC
31.57
150.0
0.10
0.02
0.009
0.000
P-103
J-151
J-152
83.4 PVC
31.64
150.0
0.25
0.05
0.038
0.001
P-104
J-93
J-153
83.4 PVC
33.43
150.0
0.04
0.01
0.000
0.000
P-105
J-118
J-154
83.4 PVC
33.82
150.0
0.03
0.01
0.000
0.000
P-106
J-152
J-118
83.4 PVC
34.83
150.0
0.13
0.02
0.013
0.000
P-107
J-46
J-151
83.4 PVC
42.17
150.0
0.63
0.12
0.212
0.009
P-108
J-155
J-49
99.4 PVC
35.91
150.0
0.01
0.00
0.000
0.000
P-109
J-151
J-154
83.4 PVC
36.34
150.0
0.27
0.05
0.045
0.002
P-110
J-21
J-156
83.4 PVC
37.32
150.0
0.14
0.03
0.012
0.000
P-111
J-42
J-36
81.4 PVC
37.65
150.0
2.53
0.49
3.127
0.118
P-112
J-99
J-91
148.4 PVC
38.10
150.0
4.99
0.29
0.590
0.022
Bentley WaterCAD V8i
P-113
J-6003.wtg
J-157
99.4 PVC Bentley Systems, Inc.38.57
150.0Solution 0.06
0.01
0.000
0.000
[08.11.00.30]
red
de agua sector
Haestad Methods
Center
SETARIP
Siemon Company Drive Suite
200 W Watertown,
Page 4 of 8
P-114 S.R.LJ-69
J-4
83.4 27
PVC
38.66
150.0 CT 06795
0.25 USA +1-0.05
0.038
0.001
203-755-1666
P-115
J-72
J-158
81.4 PVC
38.83
150.0
0.14
0.03
0.015
0.001
P-116
J-101
J-145
81.4 PVC
39.00
150.0
0.49
0.09
0.149
0.006
P-117
J-132
J-91
99.4 PVC
39.42
150.0
1.46
0.19
0.427
0.017
P-118
J-96
J-1
81.4 PVC
40.06
150.0
0.06
0.01
0.000
0.000
P-119
J-73
J-131
99.4 PVC
43.07
150.0
0.10
0.01
0.003
0.000
P-120
J-123
J-159
57.0 PVC
43.17
150.0
0.20
0.08
0.165
0.007
P-121
J-120
J-160
81.4 PVC
43.54
150.0
0.64
0.12
0.246
0.011

P-96
J-142
J-49
99.4 PVC
27.96
150.0
0.07
0.01
0.000
0.000
P-98
J-145
J-146
81.4 PVC
28.17
150.0
0.34
0.07
0.074
0.002
P-99
J-148
J-147
99.4 PVC
28.53
150.0
0.00
0.00
0.000
0.000
P-100
J-116
J-30
83.4 PVC
29.74
150.0
0.36
0.07
0.075
0.002
P-101
J-71
J-150
83.4 PVC
30.45
150.0
0.00
0.00
0.000
0.000
P-102
J-146
J-81
81.4 PVC
31.57
150.0
0.10
0.02
0.009
0.000
P-103
J-151
J-152
83.4 PVC
31.64
150.0
0.25
0.05
0.038
0.001
Active Scenario:
VERIFICACION
HIDRAULICA
DE
REDES
POTABLE
SECTOR 03
P-104
J-93
J-153
83.4 PVC
33.43
150.0
0.04 DE AGUA
0.01
0.000
0.000
P-105
J-118
J-154
83.4 PVC
33.82
150.0
0.03
0.01
0.000
0.000
FlexTable:
Pipe Table34.83
(red de
agua 0.13
sector0.02
03.wtg)
P-106
J-152
J-118
83.4 PVC
150.0
0.013
0.000
P-107
J-46
J-151
83.4 PVC
42.17
150.0
0.63
0.12
0.212
0.009
Current
Time: 0.000
hours150.0
P-108
J-155
J-49
99.4 PVC
35.91
0.01
0.00
0.000
0.000
P-109
J-151Start Node
J-154
83.4 PVC Material
36.34
150.0
0.27 Velocity
0.05 Headloss
0.045
0.002
Label
Stop Node
Diameter
Length
HazenFlow
Headloss
P-110
J-21
J-156
83.4
PVC
37.32
150.0
0.14
0.03
0.012
(mm)
(Scaled)
Williams
(L/s)
(m/s)
Gradient
(m)0.000
(m)
C
(m/km)
P-111
J-42
J-36
81.4 PVC
37.65
150.0
2.53
0.49
3.127
0.118
P-112
J-99
J-91
148.4 PVC
38.10
150.0
4.99
0.29
0.590
0.022
P-113
J-60
J-157
99.4 PVC
38.57
150.0
0.06
0.01
0.000
0.000
P-114
J-69
J-4
83.4 PVC
38.66
150.0
0.25
0.05
0.038
0.001
P-115
J-72
J-158
81.4 PVC
38.83
150.0
0.14
0.03
0.015
0.001
P-116
J-101
J-145
81.4 PVC
39.00
150.0
0.49
0.09
0.149
0.006
P-117
J-132
J-91
99.4 PVC
39.42
150.0
1.46
0.19
0.427
0.017
P-118
J-96
J-1
81.4 PVC
40.06
150.0
0.06
0.01
0.000
0.000
P-119
J-73
J-131
99.4 PVC
43.07
150.0
0.10
0.01
0.003
0.000
P-120
J-123
J-159
57.0 PVC
43.17
150.0
0.20
0.08
0.165
0.007
P-121
J-120
J-160
81.4 PVC
43.54
150.0
0.64
0.12
0.246
0.011
P-122
J-51
J-116
83.4 PVC
46.69
150.0
0.36
0.07
0.077
0.004
P-124
J-78
J-122
81.4 PVC
46.42
150.0
0.27
0.05
0.051
0.002
P-125
J-163
J-162
99.4 PVC
46.77
150.0
0.46
0.06
0.048
0.002
P-126
J-110
J-25
81.4 PVC
46.79
150.0
0.71
0.14
0.296
0.014
P-127
J-160
J-164
81.4 PVC
46.82
150.0
0.02
0.00
0.000
0.000
P-128
J-141
J-109
148.4 PVC
47.27
150.0
2.05
0.12
0.113
0.005
P-129
J-24
J-96
81.4 PVC
47.34
150.0
0.28
0.05
0.053
0.003
P-130
J-34
J-165
83.4 PVC
48.65
150.0
0.08
0.01
0.003
0.000
P-131
J-146
J-112
81.4 PVC
49.20
150.0
0.16
0.03
0.021
0.001
P-132
J-29
J-166
99.4 PVC
50.76
150.0
0.08
0.01
0.003
0.000
P-133
J-13
J-167
99.4 PVC
51.98
150.0
0.26
0.03
0.020
0.001
P-134
J-76
J-163
99.4 PVC
52.04
150.0
0.64
0.08
0.094
0.005
P-135
J-145
J-168
57.0 PVC
53.73
150.0
0.08
0.03
0.030
0.002
P-136
J-43
J-169
144.6 PVC
57.61
150.0
0.24
0.01
0.003
0.000
P-137
J-84
J-7
99.4 PVC
56.25
150.0
0.73
0.09
0.119
0.007
P-138
J-12
J-170
102.0 PVC
58.44
150.0
0.10
0.01
0.003
0.000
P-139
J-36
J-132
99.4 PVC
58.81
150.0
1.73
0.22
0.582
0.034
P-140
J-37
J-120
81.4 PVC
60.04
150.0
0.70
0.14
0.293
0.018
Bentley WaterCAD V8i
P-141
J-113
J-139
81.4 PVC Bentley Systems, Inc.60.29
150.0Solution 0.16
0.03
0.017
0.001
[08.11.00.30]
red
de agua sector
03.wtg
Haestad Methods
Center
SETARIP
Siemon Company Drive Suite
200 W Watertown,
Page 5 of 8
P-142 S.R.LJ-106
J-171
99.4 27
PVC
68.01
150.0 CT 06795
0.06 USA +1-0.01
0.002
0.000
203-755-1666
P-143
J-55
J-172
81.4 PVC
62.26
150.0
0.06
0.01
0.002
0.000
P-144
J-11
J-10
102.0 PVC
64.06
150.0
0.28
0.03
0.019
0.001
P-145
J-148
J-173
102.0 PVC
64.98
150.0
0.60
0.07
0.071
0.005
P-146
J-8
J-174
99.4 PVC
65.07
150.0
0.06
0.01
0.000
0.000
P-147
J-103
J-176
81.4 PVC
66.09
150.0
0.08
0.02
0.007
0.000
P-148
J-61
J-177
57.0 PVC
68.16
150.0
0.10
0.04
0.046
0.003
P-149
J-86
J-92
102.0 PVC
70.94
150.0
1.96
0.24
0.646
0.046

P-125
J-163
J-162
99.4 PVC
46.77
150.0
0.46
0.06
0.048
0.002
P-126
J-110
J-25
81.4 PVC
46.79
150.0
0.71
0.14
0.296
0.014
P-127
J-160
J-164
81.4 PVC
46.82
150.0
0.02
0.00
0.000
0.000
P-128
J-141
J-109
148.4 PVC
47.27
150.0
2.05
0.12
0.113
0.005
P-129
J-24
J-96
81.4 PVC
47.34
150.0
0.28
0.05
0.053
0.003
P-130
J-34
J-165
83.4 PVC
48.65
150.0
0.08
0.01
0.003
0.000
P-131
J-146
J-112
81.4 PVC
49.20
150.0
0.16
0.03
0.021
0.001
Active Scenario:
VERIFICACION
HIDRAULICA
DE
REDES
POTABLE
SECTOR 03
P-132
J-29
J-166
99.4 PVC
50.76
150.0
0.08 DE AGUA
0.01
0.003
0.000
P-133
J-13
J-167
99.4 PVC
51.98
150.0
0.26
0.03
0.020
0.001
FlexTable:
Pipe Table52.04
(red de
agua 0.64
sector0.08
03.wtg)
P-134
J-76
J-163
99.4 PVC
150.0
0.094
0.005
P-135
J-145
J-168
57.0 PVC
53.73
150.0
0.08
0.03
0.030
0.002
Current
Time: 0.000
hours150.0
P-136
J-43
J-169
144.6 PVC
57.61
0.24
0.01
0.003
0.000
P-137
J-84 Start Node
J-7
99.4 PVC Material
56.25
150.0
0.73 Velocity
0.09 Headloss
0.119
0.007
Label
Stop Node
Diameter
Length
HazenFlow
Headloss
P-138
J-12
J-170
102.0
PVC
58.44
150.0
0.10
0.01
0.003
(mm)
(Scaled)
Williams
(L/s)
(m/s)
Gradient
(m)0.000
(m)
C
(m/km)
P-139
J-36
J-132
99.4 PVC
58.81
150.0
1.73
0.22
0.582
0.034
P-140
J-37
J-120
81.4 PVC
60.04
150.0
0.70
0.14
0.293
0.018
P-141
J-113
J-139
81.4 PVC
60.29
150.0
0.16
0.03
0.017
0.001
P-142
J-106
J-171
99.4 PVC
68.01
150.0
0.06
0.01
0.002
0.000
P-143
J-55
J-172
81.4 PVC
62.26
150.0
0.06
0.01
0.002
0.000
P-144
J-11
J-10
102.0 PVC
64.06
150.0
0.28
0.03
0.019
0.001
P-145
J-148
J-173
102.0 PVC
64.98
150.0
0.60
0.07
0.071
0.005
P-146
J-8
J-174
99.4 PVC
65.07
150.0
0.06
0.01
0.000
0.000
P-147
J-103
J-176
81.4 PVC
66.09
150.0
0.08
0.02
0.007
0.000
P-148
J-61
J-177
57.0 PVC
68.16
150.0
0.10
0.04
0.046
0.003
P-149
J-86
J-92
102.0 PVC
70.94
150.0
1.96
0.24
0.646
0.046
P-150
J-66
J-32
100.0 PVC
69.63
150.0
0.50
0.06
0.056
0.004
P-151
J-9
J-80
83.4 PVC
71.24
150.0
0.85
0.16
0.372
0.026
P-152
J-98
J-83
99.4 PVC
71.91
150.0
0.92
0.12
0.180
0.013
P-153
J-178
J-128
144.6 PVC
110.82
150.0
10.40
0.63
2.609
0.289
P-154
J-179
J-55
83.4 PVC
84.15
150.0
0.18
0.03
0.021
0.002
P-155
J-38
J-111
81.4 PVC
88.83
150.0
2.34
0.45
2.714
0.241
P-156
J-137
J-74
81.4 PVC
91.64
150.0
0.32
0.06
0.067
0.006
P-157
J-19
J-135
99.4 PVC
92.65
150.0
1.12
0.14
0.259
0.024
P-158
J-32
J-155
99.4 PVC
94.08
150.0
0.22
0.03
0.013
0.001
P-159
J-70
J-60
99.4 PVC
94.21
150.0
0.41
0.05
0.039
0.004
P-160
J-160
J-137
81.4 PVC
99.05
150.0
0.50
0.10
0.156
0.015
P-161
J-88
J-99
185.4 PVC
100.10
150.0
15.76
0.58
1.679
0.168
P-162
J-124
J-139
81.4 PVC
101.77
150.0
0.19
0.04
0.025
0.003
P-163
J-173
J-51
102.0 PVC
115.01
150.0
0.49
0.06
0.049
0.006
P-164
J-53
J-95
102.0 PVC
112.70
150.0
1.69
0.21
0.493
0.056
P-165
J-91
J-130
148.4 PVC
113.78
150.0
6.45
0.37
0.948
0.108
P-166
J-103
J-8
99.4 PVC
113.92
150.0
1.45
0.19
0.422
0.048
P-167
J-22
J-181
99.4 PVC
119.05
150.0
0.30
0.04
0.023
0.003
Bentley WaterCAD V8i
P-168
J-2303.wtg
J-182
148.4 PVC Bentley Systems, Inc.
120.18
150.0Solution 4.73
0.27
0.534
0.064
[08.11.00.30]
red
de agua sector
Haestad Methods
Center
SETARIP
Siemon Company Drive Suite
200 W Watertown,
Page 6 of 8
P-169 S.R.LJ-11
J-148
99.4 27
PVC
121.93
150.0 CT 06795
0.82 USA +1-0.11
0.148
0.018
203-755-1666
P-170
J-9
J-173
102.0 PVC
123.09
150.0
0.94
0.12
0.167
0.021
P-171
J-100
J-179
83.4 PVC
125.57
150.0
0.24
0.04
0.037
0.005
P-172
J-95
J-183
99.4 PVC
124.68
150.0
0.18
0.02
0.008
0.001
P-173
J-182
J-47
148.4 PVC
125.76
150.0
4.71
0.27
0.529
0.067
P-174
J-115
J-19
148.4 PVC
138.73
150.0
3.14
0.18
0.251
0.035
P-175
J-20
J-142
99.4 PVC
135.23
150.0
0.13
0.02
0.006
0.001
P-176
J-99
J-178
148.4 PVC
142.01
150.0
10.51
0.61
2.341
0.332

P-152
J-98
J-83
99.4 PVC
71.91
150.0
0.92
0.12
0.180
0.013
P-153
J-178
J-128
144.6 PVC
110.82
150.0
10.40
0.63
2.609
0.289
P-154
J-179
J-55
83.4 PVC
84.15
150.0
0.18
0.03
0.021
0.002
P-155
J-38
J-111
81.4 PVC
88.83
150.0
2.34
0.45
2.714
0.241
P-156
J-137
J-74
81.4 PVC
91.64
150.0
0.32
0.06
0.067
0.006
P-157
J-19
J-135
99.4 PVC
92.65
150.0
1.12
0.14
0.259
0.024
P-158
J-32
J-155
99.4 PVC
94.08
150.0
0.22
0.03
0.013
0.001
Active Scenario:
VERIFICACION
HIDRAULICA
DE
REDES
POTABLE
SECTOR 03
P-159
J-70
J-60
99.4 PVC
94.21
150.0
0.41 DE AGUA
0.05
0.039
0.004
P-160
J-160
J-137
81.4 PVC
99.05
150.0
0.50
0.10
0.156
0.015
FlexTable:
Pipe Table100.10
(red de
agua15.76
sector0.58
03.wtg)
P-161
J-88
J-99
185.4 PVC
150.0
1.679
0.168
P-162
J-124
J-139
81.4 PVC
101.77
150.0
0.19
0.04
0.025
0.003
Current
Time: 0.000
hours150.0
P-163
J-173
J-51
102.0 PVC
115.01
0.49
0.06
0.049
0.006
P-164
J-53 Start Node
J-95
102.0 PVC Material
112.70
150.0
1.69 Velocity
0.21 Headloss
0.493
0.056
Label
Stop Node
Diameter
Length
HazenFlow
Headloss
P-165
J-91
J-130
148.4
PVC
113.78
150.0
6.45
0.37
0.948
(mm)
(Scaled)
Williams
(L/s)
(m/s)
Gradient
(m)0.108
(m)
C
(m/km)
P-166
J-103
J-8
99.4 PVC
113.92
150.0
1.45
0.19
0.422
0.048
P-167
J-22
J-181
99.4 PVC
119.05
150.0
0.30
0.04
0.023
0.003
P-168
J-23
J-182
148.4 PVC
120.18
150.0
4.73
0.27
0.534
0.064
P-169
J-11
J-148
99.4 PVC
121.93
150.0
0.82
0.11
0.148
0.018
P-170
J-9
J-173
102.0 PVC
123.09
150.0
0.94
0.12
0.167
0.021
P-171
J-100
J-179
83.4 PVC
125.57
150.0
0.24
0.04
0.037
0.005
P-172
J-95
J-183
99.4 PVC
124.68
150.0
0.18
0.02
0.008
0.001
P-173
J-182
J-47
148.4 PVC
125.76
150.0
4.71
0.27
0.529
0.067
P-174
J-115
J-19
148.4 PVC
138.73
150.0
3.14
0.18
0.251
0.035
P-175
J-20
J-142
99.4 PVC
135.23
150.0
0.13
0.02
0.006
0.001
P-176
J-99
J-178
148.4 PVC
142.01
150.0
10.51
0.61
2.341
0.332
P-177
J-40
J-184
81.4 PVC
138.64
150.0
0.02
0.00
0.001
0.000
P-178
J-7
J-12
99.4 PVC
138.97
150.0
1.61
0.21
0.510
0.071
P-179
J-83
J-10
102.0 PVC
139.08
150.0
1.84
0.23
0.577
0.080
P-180
J-86
J-83
102.0 PVC
139.95
150.0
1.97
0.24
0.658
0.092
P-182
J-178
J-186
81.4 PVC
157.84
150.0
0.02
0.00
0.001
0.000
P-183
J-19
J-187
99.4 PVC
166.56
150.0
0.10
0.01
0.003
0.000
P-184
J-38
J-188
81.4 PVC
163.94
150.0
0.37
0.07
0.087
0.014
P-185
J-6
J-71
83.4 PVC
175.95
150.0
0.59
0.11
0.186
0.033
P-186
J-111
J-189
81.4 PVC
176.19
150.0
0.37
0.07
0.086
0.015
P-187
J-128
J-190
81.4 PVC
180.43
150.0
0.28
0.05
0.054
0.010
P-188
J-114
J-191
83.4 PVC
179.88
150.0
0.37
0.07
0.077
0.014
P-189
J-39
J-127
144.6 PVC
230.01
150.0
6.42
0.39
1.066
0.245
P-190
J-135
J-192
81.4 PVC
276.23
150.0
0.12
0.02
0.011
0.003
P-191
J-64
J-129
81.4 PVC
1.30
150.0
0.01
0.00
0.000
0.000
P-192
J-125
J-64
81.4 PVC
104.24
150.0
0.03
0.01
0.000
0.000
P-193
J-105
J-180
81.4 PVC
30.87
150.0
0.04
0.01
0.000
0.000
P-194
J-58
J-105
81.4 PVC
73.62
150.0
0.22
0.04
0.034
0.003
P-195
J-57
J-89
99.4 PVC
10.90
150.0
0.25
0.03
0.014
0.000
Bentley WaterCAD V8i
P-196
J-5 03.wtg
J-57
99.4 PVC Bentley Systems, Inc. 6.56
150.0Solution 0.27
0.04
0.023
0.000
[08.11.00.30]
red
de agua sector
Haestad Methods
Center
SETARIP
Siemon Company Drive Suite
200 W Watertown,
Page 7 of 8
P-197 S.R.LJ-162
J-5
99.4 27
PVC
32.63
150.0 CT 06795
0.33 USA +1-0.04
0.027
0.001
203-755-1666
P-198
J-66
J-3
99.4 PVC
123.67
150.0
0.07
0.01
0.001
0.000
P-199
J-3
J-102
99.4 PVC
137.36
150.0
0.29
0.04
0.022
0.003
P-200
J-3
J-193
102.0 PVC
24.21
150.0
0.10
0.01
0.000
0.000
P-201
J-173
J-3
102.0 PVC
84.57
150.0
0.73
0.09
0.104
0.009
P-202
J-156
J-136
83.4 PVC
27.49
150.0
0.04
0.01
0.000
0.000
P-203
J-156
J-149
83.4 PVC
32.15
150.0
0.06
0.01
0.000
0.000
P-204
J-19
J-6
83.4 PVC
3.12
150.0
1.18
0.22
0.667
0.002

P-179
P-180
P-182
P-183
P-184
P-185
P-186
P-187
P-188
P-189
P-190
P-191
P-192
Label
P-193
P-194
P-195
P-196
P-197
P-198
P-199
P-200
P-201
P-202
P-203
P-204
P-205
P-209
P-2583
P-2584

J-83
J-10
102.0 PVC
139.08
150.0
1.84
0.23
0.577
0.080
J-86
J-83
102.0 PVC
139.95
150.0
1.97
0.24
0.658
0.092
J-178
J-186
81.4 PVC
157.84
150.0
0.02
0.00
0.001
0.000
J-19
J-187
99.4 PVC
166.56
150.0
0.10
0.01
0.003
0.000
J-38
J-188
81.4 PVC
163.94
150.0
0.37
0.07
0.087
0.014
J-6
J-71
83.4 PVC
175.95
150.0
0.59
0.11
0.186
0.033
J-111
J-189
81.4 PVC
176.19
150.0
0.37
0.07
0.086
0.015
Active Scenario:
VERIFICACION
HIDRAULICA
DE
REDES
POTABLE
SECTOR
J-128
J-190
81.4 PVC
180.43
150.0
0.28 DE AGUA
0.05
0.054
0.010
J-114
J-191
83.4 PVC
179.88
150.0
0.37
0.07
0.077
0.014
FlexTable:
Pipe Table230.01
(red de
agua 6.42
sector0.39
03.wtg)
J-39
J-127
144.6 PVC
150.0
1.066
0.245
J-135
J-192
81.4 PVC
276.23
150.0
0.12
0.02
0.011
0.003
Current
Time: 0.0001.30
hours150.0
J-64
J-129
81.4 PVC
0.01
0.00
0.000
0.000
J-125Start Node
J-64
81.4 PVC Material
104.24
150.0
0.03 Velocity
0.01 Headloss
0.000
0.000
Stop Node
Diameter
Length
HazenFlow
Headloss
J-105
J-180
81.4
PVC
30.87
150.0
0.04
0.01
0.000
(mm)
(Scaled)
Williams
(L/s)
(m/s)
Gradient
(m)0.000
(m)
C
(m/km)
J-58
J-105
81.4 PVC
73.62
150.0
0.22
0.04
0.034
0.003
J-57
J-89
99.4 PVC
10.90
150.0
0.25
0.03
0.014
0.000
J-5
J-57
99.4 PVC
6.56
150.0
0.27
0.04
0.023
0.000
J-162
J-5
99.4 PVC
32.63
150.0
0.33
0.04
0.027
0.001
J-66
J-3
99.4 PVC
123.67
150.0
0.07
0.01
0.001
0.000
J-3
J-102
99.4 PVC
137.36
150.0
0.29
0.04
0.022
0.003
J-3
J-193
102.0 PVC
24.21
150.0
0.10
0.01
0.000
0.000
J-173
J-3
102.0 PVC
84.57
150.0
0.73
0.09
0.104
0.009
J-156
J-136
83.4 PVC
27.49
150.0
0.04
0.01
0.000
0.000
J-156
J-149
83.4 PVC
32.15
150.0
0.06
0.01
0.000
0.000
J-19
J-6
83.4 PVC
3.12
150.0
1.18
0.22
0.667
0.002
J-4
J-113
81.4 PVC
15.20
150.0
0.26
0.05
0.049
0.001
J-2
J-1
81.4 PVC
0.45
150.0
0.00
0.00
0.000
0.000
J-175
CRP-05
185.4 PVC
10.86
150.0
19.13
0.71
2.386
0.026
CRP-05
J-88
185.4 PVC
55.64
150.0
19.12
0.71
2.402
0.134

red de agua sector 03.wtg


SETARIP S.R.L

Bentley Systems, Inc. Haestad Methods Solution Center


27 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1203-755-1666

03

Bentley WaterCAD V8i


[08.11.00.30]
Page 8 of 8